Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Review of field-reversed configurations

This review addresses field-reversed configurations (FRCs), which are compact-toroidal magnetic systems with little or no toroidal field and very high {beta} (ratio of plasma pressure to magnetic pressure). Although enthusiasm for the FRC has primarily been driven by its potential for an attractive fusion reactor, this review focuses on the physics rather than on technological or engineering aspects. Major advances in both theory and experiment have taken place since the previous comprehensive FRC review in 1988. Even so many questions remain. In particular, even though FRC experiments have exhibited remarkable stability, how well this extrapolates to larger systems remains unresolved. The review considers FRCs under familiar topical categories: equilibrium, global stability, self-organization, transport, formation, and sustainment.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Emergent reduced dimensionality by vertex frustration in artificial spin ice

Reducing the dimensionality of a physical system can have a profound effect on its properties, as in the ordering of low-dimensional magnetic materials, phonon dispersion in mercury chain salts, sliding phases, and the electronic states of graphene. Here we explore the emergence of quasi-one-dimensional behaviour in two-dimensional artificial spin ice, a class of lithographically fabricated nanomagnet arrays used to study geometrical frustration. We extend the implementation of artificial spin ice by fabricating a new array geometry, the so-called tetris lattice. We demonstrate that the ground state of the tetris lattice consists of alternating ordered and disordered bands of nanomagnetic moments. The disordered bands can be mapped onto an emergent thermal one-dimensional Ising model. Furthermore, we show that the level of degeneracy associated with these bands dictates the susceptibility of island moments to thermally induced reversals, thus establishing that vertex frustration can reduce the relevant dimensionality of physical behaviour in a magnetic system.

36 MATERIALS SCIENCE↗

Skyrmion lattice formation and destruction mechanisms probed with TR-SANS

Magnetic skyrmions are topologically protected, nanoscale whirls of the spin configuration that tend to form hexagonally ordered arrays. As a topologically non-trivial structure, the nucleation and annihilation of the skyrmion, as well as the interaction between skyrmions, varies from conventional magnetic systems. Recent works have suggested that the ordering kinetics in these materials occur over millisecond or longer timescales, which is unusually slow for magnetic dynamics. The current work investigates the skyrmion ordering kinetics, particularly during lattice formation and destruction, using time-resolved small angle neutron scattering (TR-SANS). Evaluating the time-resolved structure and intensity of the neutron diffraction pattern reveals the evolving real-space structure of the skyrmion lattice and the timeframe of the formation. Measurements were performed on three prototypical skyrmion materials: MnSi, (Fe,Co)Si, and Cu 2 OSeO 3 . To probe lattice formation and destruction kinetics, the systems were prepared in the stable skyrmion state, and then a square-wave magnetic field modulation was applied. The measurements show that the skyrmions quickly form ordered domains, with a significant distribution in lattice parameters, which then converge to the final structure; the results confirm the slow kinetics, with formation times between 10 ms and 99 ms. Comparisons are made between the measured formation times and the fundamental material properties, suggesting the ordering temperature, saturation magnetization and magnetocrystalline anisotropy may be driving the timeframes. Micromagnetic simulations were also performed and support a scaling of the kinetics with sample volume, a behavior which is caused by the reconciling of misaligned domains.

Liyanage, W. L. N. C.↗

Magnetic suspension and balance system study

A compact design for a superconducting magnetic suspension and balance system is developed for a 8 ft. x 8 ft. transonic wind tunnel. The main features of the design are: a compact superconducting solenoid in the suspended airplane model; permanent magnet wings; one common liquid helium dewar for all superconducting coils; efficient new race track coils for roll torques; use of established 11 kA cryostable AC conductor; acceptable AC losses during 10 Hz control even with all steel structure; and a 560 liter/hour helium liquefier. Considerable design simplicity, reduced magnet weights, and reduced heat leak results from using one common dewar which eliminates most heavy steel structure between coils and the suspended model. Operational availability is thought to approach 100% for such magnet systems. The weight and cost of the magnet system is approximately one-third that of previous less compact designs.

Boom, R. W.↗

Influence of Photospheric Magnetic Conditions on the Catastrophic Behaviors of Flux Ropes in Solar Active Regions

Since only the magnetic conditions at the photosphere can be routinely observed in current observations, it is of great significance to determine the influences of photospheric magnetic conditions on solar eruptive activities. Previous studies about catastrophe indicated that the magnetic system consisting of a flux rope in a partially open bipolar field is subject to catastrophe, but not if the bipolar field is completely closed under the same specified photospheric conditions. In order to investigate the influence of the photospheric magnetic conditions on the catastrophic behavior of this system, we expand upon the 2.5-dimensional ideal magnetohydrodynamic model in Cartesian coordinates to simulate the evolution of the equilibrium states of the system under different photospheric flux distributions. Our simulation results reveal that a catastrophe occurs only when the photospheric flux is not concentrated too much toward the polarity inversion line and the source regions of the bipolar field are not too weak; otherwise no catastrophe occurs. As a result, under certain photospheric conditions, a catastrophe could take place in a completely closed configuration, whereas it ceases to exist in a partially open configuration. This indicates that whether the background field is completely closed or partially open is not the only necessary condition for the existence of catastrophe, and that the photospheric conditions also play a crucial role in the catastrophic behavior of the flux rope system.

79 ASTRONOMY AND ASTROPHYSICS↗

State switching kinetics for quasi-one-dimensional nanosystems: Effects of Finite length and irradiation

The state switching in an extended quasi-one-dimensional material is modeled by the stochastic formation of local new-state nuclei and their subsequent growth along the system axis. An analytical approach is developed to describe the influence of defects, dividing a sample into an ensemble of finite-length segments, on its state switching kinetics. As applied to magnetic systems, the method makes it possible to calculate magnetization curves for different defect concentrations and parameters of material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and Testing of Subsystems for Mo-99 Production Facility

So far, three beamline configurations have been proposed for the SHINE Medical Technologies facility for producing fission-product 99 Mousing a D/T-accelerator (Figure 1). One configuration, proposed by Los Alamos National Laboratory (LANL), includes a three-bend magnet system with a total 20 o bending angle. This configuration also includes a set of octuplet magnets to generate a non-Gaussian beam profile. Argonne has proposed two beamlines based on a (1)10° bending magnet (Appendix A and Ref. 1) and (2) alpha magnets (Appendix B) that use a pair of raster doublets to redistribute the beam over the face of the target. While those configurations are quite different, and each of the configurations has its advantages and disadvantages, they all have to incorporate the means to verify beam parameters before placing the beam on the target, monitor beam position and shape during a run, protect the target housing from the overheating due to beam displacement, and protect the beamlines from overheating due to beam misalignment.

07 ISOTOPE AND RADIATION SOURCES↗

Design of Helical Cooling Channel for Muon Collider

Fast muon beam six dimensional (6D) phase space cooling is essential for muon colliders. The Helical Cooling Channel (HCC) uses hydrogen-pressurized RF cavities imbedded in a magnet system with solenoid, helical dipole, and helical quadrupole components that provide the continuous dispersion needed for emittance exchange and effective 6D beam cooling. A series of HCC segments, each with sequentially smaller aperture, higher magnetic field, and higher RF frequency to match the beam size as it is cooled, has been optimized by numerical simulation to achieve a factor of 10{sup 5} emittance reduction in a 300 m long channel with only a 40% loss of beam. Conceptual designs of the hardware required for this HCC system and the status of the RF studies and HTS helical solenoid magnet prototypes are described.

43 PARTICLE ACCELERATORS↗

Design and fabrication of a superconducting magnet for an 18 GHz electron cyclotron resonance ion/photon source NFRI-ECRIPS

A superconducting magnet was designed and fabricated for an 18 GHz ECR ion/photon source, which will be installed at National Fusion Research Institute (NFRI) in South Korea. The magnetic system consists of a set of four superconducting coils for axial mirror field and 36 pieces of permanent magnets for hexapolar field. The superconducting coils with a cryocooler (1.5 W - 4.2 K) allow one to reach peak mirror fields of 2.2 T in the injection and those of 1.5 T in the extraction regions on the source axis, and the resultant hexapolar field gives 1.35 T on the plasma chamber wall. The unbalanced magnetic force between the coils and surrounding yoke has been minimized to 16 ton by a coil arrangement and their electrical connection, and then was successfully suspended by 12 strong thermal insulating supports made of large numbers of carbon fibers. In order to block radiative thermal losses, multilayer thermal insulations are covered on the coil windings as well as 40-K aluminum thermal shield. Also new schemes of quench detection and safety system (coil divisions, quench detection coils, and heaters) were employed. For impregnation of the windings a special epoxy has been selected and treated to have a higher breaking strength and a higher thermal conductivity, which enables the superconductors to be uniformly and rapidly cooled down or heated during a quench.

43 PARTICLE ACCELERATORS↗

Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy

Purpose: In gynecologic cancers, magnetic resonance (MR) imaging is the modality of choice for visualizing tumors and their surroundings because of superior soft-tissue contrast. Real-time MR guidance of catheter placement in interstitial brachytherapy facilitates target coverage, and would be further improved by providing intraprocedural estimates of dosimetric coverage. A major obstacle to intraprocedural dosimetry is the time needed for catheter trajectory reconstruction. Herein the authors evaluate an active MR tracking (MRTR) system which provides rapid catheter tip localization and trajectory reconstruction. The authors assess the reliability and spatial accuracy of the MRTR system in comparison to standard catheter digitization using magnetic resonance imaging (MRI) and CT. Methods: The MRTR system includes a stylet with microcoils mounted on its shaft, which can be inserted into brachytherapy catheters and tracked by a dedicated MRTR sequence. Catheter tip localization errors of the MRTR system and their dependence on catheter locations and orientation inside the MR scanner were quantified with a water phantom. The distances between the tracked tip positions of the MRTR stylet and the predefined ground-truth tip positions were calculated for measurements performed at seven locations and with nine orientations. To evaluate catheter trajectory reconstruction, fifteen brachytherapy catheters were placed into a gel phantom with an embedded catheter fixation framework, with parallel or crossed paths. The MRTR stylet was then inserted sequentially into each catheter. During the removal of the MRTR stylet from within each catheter, a MRTR measurement was performed at 40 Hz to acquire the instantaneous stylet tip position, resulting in a series of three-dimensional (3D) positions along the catheter’s trajectory. A 3D polynomial curve was fit to the tracked positions for each catheter, and equally spaced dwell points were then generated along the curve. High-resolution 3D MRI of the phantom was performed followed by catheter digitization based on the catheter’s imaging artifacts. The catheter trajectory error was characterized in terms of the mean distance between corresponding dwell points in MRTR-generated catheter trajectory and MRI-based catheter digitization. The MRTR-based catheter trajectory reconstruction process was also performed on three gynecologic cancer patients, and then compared with catheter digitization based on MRI and CT. Results: The catheter tip localization error increased as the MRTR stylet moved further off-center and as the stylet’s orientation deviated from the main magnetic field direction. Fifteen catheters’ trajectories were reconstructed by MRTR. Compared with MRI-based digitization, the mean 3D error of MRTR-generated trajectories was 1.5 ± 0.5 mm with an in-plane error of 0.7 ± 0.2 mm and a tip error of 1.7 ± 0.5 mm. MRTR resolved ambiguity in catheter assignment due to crossed catheter paths, which is a common problem in image-based catheter digitization. In the patient studies, the MRTR-generated catheter trajectory was consistent with digitization based on both MRI and CT. Conclusions: The MRTR system provides accurate catheter tip localization and trajectory reconstruction in the MR environment. Relative to the image-based methods, it improves the speed, safety, and reliability of the catheter trajectory reconstruction in interstitial brachytherapy. MRTR may enable in-procedural dosimetric evaluation of implant target coverage.

60 APPLIED LIFE SCIENCES↗

A table-top, repetitive pulsed magnet for nonlinear and ultrafast spectroscopy in high magnetic fields up to 30 T

We have developed a mini-coil pulsed magnet system with direct optical access, ideally suited for nonlinear and ultrafast spectroscopy studies of materials in high magnetic fields up to 30 T. The apparatus consists of a small coil in a liquid nitrogen cryostat coupled with a helium flow cryostat to provide sample temperatures down to below 10 K. Direct optical access to the sample is achieved with the use of easily interchangeable windows separated by a short distance of ∼135 mm on either side of the coupled cryostats with numerical apertures of 0.20 and 0.03 for measurements employing the Faraday geometry. As a demonstration, we performed time-resolved and time-integrated photoluminescence measurements as well as transmission measurements on InGaAs quantum wells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Criticality and Magnetic Phases of Ising Shastry–Sutherland Candidate Holmium Tetraboride

Frustrated magnetic systems arising in geometrically constrained lattices represent rich platforms for exploring unconventional phases of matter, including fractional magnetization plateaus, incommensurate orders and complex domain dynamics. However, determining the microscopic spin configurations that stabilize such phases is a key challenge, especially when in-plane and out-of-plane spin components coexist and compete. Here, we combine neutron scattering and magnetic susceptibility experiments with simulations to investigate the emergence of field-induced fractional plateaus and the related criticality in a frustrated magnet holmium tetraboride (HoB 4 ) that represents the family of rare earth tetraborides that crystalize in a Shastry–Sutherland lattice in the ab plane. We focus on the interplay between classical and quantum criticality near phase boundaries, as well as the role of material defects in the stabilization of the ordered phases. We find that simulations using classical annealing can explain certain observed features in the experimental Laue diffraction and the origin of multiple magnetization plateaus. Our results show that defects and out-of-plane interactions play an important role and can guide the route towards resolving microscopic spin textures in highly frustrated magnets.

Frustration↗

Design Study of a Coupled Inner-Stator Magnetically Geared Motor for Electric Aircraft Applications

Electric aircraft require high performance and high reliability electric motor drivetrains. A geared electric motor drivetrain will outperform a direct drive motor drivetrain in most applications. Traditional mechanical gearing, however, has mechanical contact-based wear and failure modes that result in added maintenance costs and require an oil lubrication system. Magnetically geared motor drives are a potential technology for electric aircraft applications capable of enabling the benefits of a geared drive without the maintenance, reliability, and lubrication system cost of mechanical gears. In this paper, a topology of magnetically geared motor, an inner stator magnetically geared motor, is explored to estimate its achievable performance for electric aircraft applications. Optimization results on the topology show that it can achieve greater than 15 Nm/kg and 96% efficiency at 100 kW of power.

Thomas Tallerico↗

Design Study of a Coupled Inner-Stator Magnetically Geared Motor for Electric Aircraft Applications

Abstract- Electric aircraft require high performance and high reliability electric motor drivetrains. A geared electric motor drivetrain will outperform a direct drive motor drivetrain in most applications. Traditional mechanical gearing, however, has mechanical contact-based wear and failure modes that result in added maintenance costs and require an oil lubrication system. Magnetically geared motor drives are a potential technology for electric aircraft applications capable of enabling the benefits of a geared drive without the maintenance, reliability, and lubrication system cost of mechanical gears. In this paper, a topology of magnetically geared motor, an inner-stator magnetically geared motor, is explored to estimate its achievable performance for electric aircraft applications. Optimization results on the topology show that it can achieve greater than 15 Nm/kg specific torque and 96% efficiency at 100 kW of power.

Thomas Tallerico↗

The Hard Ferromagnetism in FePS 3 Induced by Non‐Magnetic Molecular Intercalation

Abstract Manipulating the magnetic ground states of 2D magnets is a focal point of recent research efforts. Various methods have demonstrated efficacy in modulating the magnetic properties inherent to van der Waals (vdW) magnetic systems. Herein, the emergence of robust anisotropic ferromagnetism within antiferromagnetic FePS 3 is unveiled via intercalation with non‐magnetic pyridinium ions. A one‐step ion exchange reaction facilitates the formation of energetically favorable B‐phase and metastable P‐phase. Notably, both B‐ and P‐phases manifest hard ferromagnetic behavior, featuring substantial unsaturated coercive fields (>7 T) and high Curie temperatures (72–87 K). First‐principles calculations elucidate the pivotal role of electron transfer from pyridinium ions to FePS 3 in engineering magnetic exchange interactions. Calculated effective spin Hamiltonian corroborates the observed hard ferromagnetism in intercalated FePS 3 . This study offers crucial insights into hard magnetism in intercalated vdW materials, thereby presenting promising avenues for 2D vdW magnet‐based magnetic devices.

Ou, Yunbo↗

Tuning interfacial Dzyaloshinskii-Moriya interactions in thin amorphous ferrimagnetic alloys

Skyrmions can be stabilized in magnetic systems with broken inversion symmetry and chiral interactions, such as Dzyaloshinskii-Moriya interactions (DMI). Further, compensation of magnetic moments in ferrimagnetic materials can significantly reduce magnetic dipolar interactions, which tend to favor large skyrmions. Tuning DMI is essential to control skyrmion properties, with symmetry breaking at interfaces offering the greatest flexibility. However, in contrast to the ferromagnet case, few studies have investigated interfacial DMI in ferrimagnets. Here we present a systematic study of DMI in ferrimagnetic CoGd films by Brillouin light scattering. We demonstrate the ability to control DMI by the CoGd cap layer composition, the stack symmetry and the ferrimagnetic layer thickness. The DMI thickness dependence confirms its interfacial nature. In addition, magnetic force microscopy reveals the ability to tune DMI in a range that stabilizes sub-100 nm skyrmions at room temperature in zero field. Our work opens new paths for controlling interfacial DMI in ferrimagnets to nucleate and manipulate skyrmions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nonorthogonally magnetised permanent-magnet Faraday isolators

This paper describes a novel configuration of permanent-magnet magnetic systems for high-power Faraday isolators that are used in high-power lasers. An increase in magnetic field is ensured by magnets with a magnetisation vector inclined to the isolator axis. Numerical simulation results agree well with experimentally determined magnetic field distributions. (quantum electronic devices)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

All-optical switching of magnetoresistive devices using telecom-band femtosecond laser

Ultrafast all-optical switching of the magnetization of various magnetic systems is an intriguing phenomenon that can have tremendous impact on information storage and processing. Here, we demonstrate all-optical switching of GdFeCo alloy films using a telecom-band femtosecond fiber laser. We further fabricate Hall cross devices and electrically readout all-optical switching by measuring anomalous Hall voltage changes. The use of a telecom laser and the demonstrated all-optical switching of magnetoresistive devices represent the first step toward integration of opto-magnetic devices with mainstream photonic devices to enable novel optical and spintronic functionalities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗