Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Linear Energy Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

BioSentinel: Forging the path for Deep Space CubeSat Missions

The BioSentinel mission was launched in 2022 aboard the SLS launch vehicle as part of the Artemis-I campaign and continues mission operations into 2024. The 6U CubeSat has been characterizing deep space radiation at large distances from Earth. This presentation gives a status of the mission performance to date, as well as some of the lessons learned from project. BioSentinel has achieved unprecedented performance as an SLS secondary payload due to preparation, planning, and a robust design. Pre-launch antenna and interface testing with both DSN and ESA confirmed command and data pathways and allowed for operational flexibility in the critical early hours post-deployment. Mission Operations simulations prior to launch identified potential risks and trained operators to respond in flight, preparing the team to react quickly and successfully to detumble the spacecraft and enter a power-positive state. The spacecraft would not have survived without the inclusion of the trailblazing 3D-printed composite cold gas propulsion system. The non-standard tank geometry enabled efficient use of the limited space available in the CubeSat form factor as well as the capability to detumble the spacecraft and manage momentum for extended mission durations, while providing sufficient margin to execute potential delta-V maneuvers. Following the conclusion of the primary science mission, the Linear Energy Transfer (LET) Spectrometer has continued to collect solar and galactic radiation data from its unique location in heliocentric orbit. The free space dataset offered by the BioSentinel LET is a valuable source of data for both model validation and future mission planning. As the spacecraft travels farther from Earth it is poised to provide longitudinally distributed measurements of solar particle events during solar maximum. NASA Ames led development of the BioSentinel spacecraft to operate for long durations in deep space. The novel subsystems and COTS components that comprise the BioSentinel bus can serve as a template for future deep space missions, while the lessons the team has learned from well over a year of continuous operations will enable improved performance in the generation of deep space CubeSat missions.

BioSentinel↗

Biosentinel: Update on Extended Mission Operations

BioSentinel has achieved unprecedented performance of an SLS secondary payload due to preparation, planning, and a robust design. Following the conclusion of the primary science mission in April 2023, the Linear Energy Transfer (LET) Spectrometer has continued to collect solar and galactic radiation data from its unique location in heliocentric orbit. The free space dataset offered by the BioSentinel LET is a valuable source of data for both model validation and future mission planning. As the spacecraft travels farther from Earth it is poised to provide longitudinally distributed measurements of solar particle events during solar maximum. Flight heritage has now been gained on many of the novel spacecraft components. The spacecraft bus continues to operate within the design envelope. The 3D-printed cold gas propulsion system provides momentum unloading from the reaction wheels. The power system has maintained power positive levels during flight. The IRIS radio communicates on a weekly basis with the Deep Space Network. The extended mission operations are allowing the team to characterize the performance of the spacecraft components over longer durations of operations. NASA Ames led development of the BioSentinel spacecraft and mission operations. The novel subsystems and COTS components that comprise the BioSentinel bus can serve as a template for future deep space missions. With over a year of continuous operations, the data will inform the next generation of interplanetary smallsat missions.

BioSentinel↗

Comparison of Geant4-DNA and RITRACKS/RITCARD: Microdosimetry, Nanodosimetry and DNA Damage Predictions for Low to High LET Ions

Low linear energy transfer (LET) ionizing radiations induce homogeneously distributed DNA damage at the cellular scale, while high LET ionizing radiations are well known to create complex biological damage including clustered double strand breaks (DSB). Clustered DSB are critical events that are difficult to repair, leading to increased biological outcomes compared to low LET radiation exposure. Recent studies have shown that DNA compaction, which can be actively modified by the cell to allow DNA repair, influences the yield of DSB [1]. The goal of this work is to determine the impact of DNA compaction on chromosome aberration formation, a biomarker of radiation-induced cancer risk. The RITRACKS track structure code [2], together with the RITCARD code [3], allow one to simulate the transport of high LET ions, calculate DNA damage and repair, and chromosome aberration formation, but does not include detailed geometrical models of DNA. The Geant4-DNA toolkit provides such detailed models with different levels of DNA compaction [1,4], but does not model chromosome aberration formation. In this work, these highly detailed DNA geometries are used to compute DNA breaks with Geant4-DNA and combine the results with the RITCARD tool to compute chromosome aberrations. As a first step, we compared the transport models used in RITRACKS and Geant4-DNA and newly released heavy ion model transport (G4DNARuddIonisationExtendedModel Geant4 v11.2) to ensure consistency between the physical stage of the two radiation transport codes. We compared energy deposition at the micrometric and nanometric scales for different ions (H 250 MeV, H 150 Me, He 250 MeV/n, C 290 MeV/n, O 350 MeV/n, O 55 MeV/n, Si 170MeV/n, Ti 300 MeV/n, Ti 300 MeV/n, Fe 600 MeV/n, Fe 450 MeV/n and Fe 300 MeV/n) with LET ranging from ~0.4 keV/μm up to 235 keV/μm. Excellent agreement is found for both microdosimetric and nanodosimetric spectra for all ion types and energies. The calculation of DNA breaks and their complexity with the Geant4-DNA is an ongoing work, and comparison with RITCARD will be presented based on result availability at the time of the conference. [1] Tang et al. (2019). Med. Phys., 46(3), 1501-1511. [2] Plante et al. (2008). NJP, 10(12), 125020. [3] Plante et al. (2019). Rad. Res., 192(3), 282-298. [4] Incerti et al. (2018). Med. Phys., 45(8), e722-e739.

Floriane Poignant↗

Final Report on Radiation Measurements Performed Inside of the BEAM Module

Measurements of the radiation environment inside of the Bigelow Expandable Activity Module (BEAM) have been made on a pseudo-continuous basis since June 6, 2016 using both passive and active instrumentation. Passive detectors yield a single cumulative dose value (or average daily dose) over the measurement period from deploy to return to ground. Active Radiation Environment Monitor (REM) sensors yield dose rate, Linear Energy Transfer (LET) spectra, and particle-specific dose, all on a 1-minute cadence. From the initial install in 2016 until early 2018, BEAM was an empty module. In 2018, further testing was approved and stowage began to be moved into BEAM. As a result, it was decided to stop measurements with RAM detectors to avoid potential difficulties with access after stowage was added. The REM sensors remained however in the original deploy locations.

radiation exposure↗

Evaluation of the Recent Improvements of the Nowcast of Aerospace Ionizing Radiation System (NAIRAS)

The Nowcast of Aerospace Ionizing Radiation System (NAIRAS) model is a real-time, global, physics-based model used to assess radiation exposure now running in real-time and in run on request (RoR) mode at NASA Goddard’s Community Coordinated Modeling Center. NAIRAS was recently updated to extend the galactic cosmic ray (GCR) model to include ultra-heavy nuclei (Z=29-92, A=64-238) for single event effects assessment from high linear energy transfer processes, to expand the geomagnetic cutoff rigidity model to use the either the TS05 (Tsyganenko and Sitnov, 2005), T89 (Tsyganenko, 1989), or the International Geomagnetic Reference Field model (IGRF) magnetic field models, and to improve the solar energetic particle (SEP) proton spectral fitting to better represent relativist protons during ground level enhancements. Here, we evaluate the recent NAIRAS improvements for a range of conditions. First, we demonstrate the effect of choice in magnetic field model to the NAIRAS computed dosimetric quantities for a United States domestic flight and a transatlantic flight during the May 11, 2024 SEP event. Second, the effect of ultra-heavy ions on SEP dose rate is examined for two different flight trajectories during the top SEP events. Lastly, the effect of ultra-heavy ions on NAIRAS computed GCR dose rates at solar minimum and maximum is demonstrated.

Daniel B Phoenix↗

EdgeCortix SAKURA-I Machine-Learning, PCIe Accelerator SEE Heavy Ion Test Report

To enable autonomy in space, machine-learning and computer vision applications become invaluable for sensor processing. However, these algorithms are computationally complex and unfeasible for many embedded central processing units (CPUs) and usually require external coprocessors, such as graphics processing units (GPUs) or accelerators specific to the application, including application specific integrated circuits (ASICs). In power-constrained systems, GPUs tend to consume more power than is acceptable (>40W), so lower-power accelerators have shown promise to provide the performance needed under spacecraft constraints. For radiation engineers, developing methodologies that can properly test CPUs, GPUs, and accelerators, and enable comparisons between them remains a necessary complication to solve as the devices become more complex. The methodology in this test aims to be a start in developing a baseline single-event effect (SEE) test for client-device machine learning accelerators. This category of devices do not host their own operating system. This testing campaign is a continuation of a previous 200 MeV proton test performed in January 2024. This report covers two heavy ion tests of the SAKURA-I card: one in April 2024, and one in June 2024. Additional data was needed after the April test due to ion-range issues experienced at higher linear-energy transfers (LETs). These range issues are described in more detail in Section 8. This experiment characterizes SEEs and data error susceptibility of the EdgeCortix SAKURA-I machine-learning accelerator under heavy ions. The device was monitored for single event upsets (SEUs) and single event functional interrupts (SEFIs) at the Lawrence Berkeley National Laboratory’s 88-inch cyclotron. The SAKURA-I board accelerates machine-learning inference applications on a host computer through a PCIex16 connection. For the purposes of devising an end to end automated analysis workflow for this experiment, the YOLO-V5 and SSD300 objection-detection models, and the ResNet-50, EfficientNet, and MobileNetV2 image classification models were used as a representative suite of analytical machine-learning models.

Seth S Roffe↗

Simulation of Radiation-Induced DNA Damage With the Code RITRACKS

INTRODUCTION DNA damage is one of the most physiologically important effects of ionizing radiation. Clustered DNA damage events, like double-strand breaks (DSBs), have the most notable biological consequences. DNA damage types depend on both the track structure of the radiation and the spatial organization of the DNA. High linear energy transfer (LET) charged nuclei, found in galactic cosmic rays (GCR), are known to produce large numbers of complex DNA damage events. The human genome is packaged into chromatin, which can take on locus-dependent and cell type-dependent spatial conformations that correspond to epigenetic states, such as more open, extended structures in transcriptionally active chromatin. These epigenetic differences can affect DNA break patterns in response to ionizing radiation, potentially creating distinct DNA repair and signaling outcomes across the genome in different cells. MATERIAL AND METHODS The code RITRACKS (Relativistic Ion Tracks), which simulates stochastic radiation track structures and radiation chemistry, was used to model damage on isolated and histone-bound DNA by various types of ions and photons. The changes made to the code to perform radiation-induced DNA damage, and simulation results on single nucleosomes are given in our recent paper. In this work, the DNA building capabilities of RITRACKS have been extended to simulate more complex DNA structures build on the coarse-grain simulation framework meso-WLCsim. This code can sample generic chromatin fiber conformation ensembles based on the geometry of nucleosomes and mechanical properties of DNA. Using RITRACKS, we simulated the fragment length distributions (FLD) of irradiated DNA structures built using the chromatin conformations of WLCsim and obtained results representative of those obtained with Radiation-Induced Correlated Cleavage with sequencing (RICC-Seq) experiments [6]. We have also performed Fe ion and photon irradiations of K562, IMR90, BJ and RPE-1 cells at NSRL to experimentally validate results. Sample processing and data analysis are in progress and any available preliminary results will be discussed. DISCUSSION The recent updates in the code RITRACKS allow the calculation of several quantities such as the DNA damage yield and the FLD. This approach can be used to model epigenetic state-specific chromatin structure parameters to leverage the epigenetic state data available for many human cell types to infer relative DNA damage sensitivity among genomic loci.

I Plante↗

A NASA Flight Surgeon Survey for Space Radiation Risk Communication

NASA has recently completed an uncrewed mission to lunar orbit with the Artemis I mission and continues to plan future crewed missions to the lunar surface and beyond. Astronauts are exposed to various spaceflight hazards including space radiation, which comprises a complex mixture of high linear-energy-transfer (LET) particles that differ appreciably from typical terrestrial exposures. As NASA embarks on missions beyond low-earth-orbit, crew members are expected to accumulate greater exposures than have been measured previously. Consequently, tools that effectively communicate space radiation health risks are important for mission planning. In addition to other spaceflight hazards, NASA flight surgeons are tasked with communicating space radiation risks to crew members for flight certification and informed consent of spaceflight hazards. In keeping with recommendations of the National Academies of Sciences, Engineering, and Medicine1 (NASEM), NASA is engaged in improving its risk communication tools. In an effort to improve these tools, this presentation provides NASA flight surgeon responses to a survey that solicits information about the primary concerns of space radiation health risks and best approaches for risk communication.

Rania W Ghatas↗

A model of the effects of heavy ion radiation on human tissue

In heavy ion radiotherapy and space travel humans are exposed to energetic heavy ions (C, Si, Fe and others). This type of irradiation often produces more severe biological effects per unit dose than more common X-rays. A new Monte Carlo model generates a physical space with the complex geometry of human tissue or a cell culture based model of tissue, which is affected by the passage of ionizing radiation. For irradiation, the model relies on a physical code for the ion track structure; for tissues, cellular maps are derived from two- or three-dimensional confocal microscopy images using image segmentation algorithm, which defines cells as pixilated volumes. The model is used to study tissue-specific statistics of direct ion hits and the remote ion action on cells. As an application of the technique, we considered the spatial pattern of apoptotic cells after heavy ion irradiation. The pattern of apoptosis is modeled as a stochastic process, which is defined by the action cross section taken from available experimental data. To characterize the degree of apoptosis, an autocorrelation function that describes the spatial correlation of apoptotic cells is introduced. The values of the autocorrelation function demonstrate the effect of the directionality of the radiation track on the spatial arrangements of inactivated cells in tissue. This effect is intrinsic only to high linear-energy-transfer radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Beta Androstenediol Mitigates the Damage of 1 GeV/n Fe Ion Particle Radiation to the Hematopoietic System

Space exploration is associated with exposure to 1-3 Gy solar particle radiation and galactic cosmic radiation that could increase cancer rates. Effective nontoxic countermeasures to high linear energy transfer (LET) radiation exposure are highly desirable but currently not available. The aim was to determine whether a single subcutaneous injection of androstenediol ({Delta}(5) androsten-3{beta}, 17{beta}-diol [AED]) could mitigate and restore the mouse hematopoetic system from the radiation-mediated injury of 3 Gy whole-body high LET (56)Fe(26+) exposure. The findings show that postradiation AED treatment has an overall positive and significant beneficial effect to restore the levels of hematopoeitic elements (p < 0.001). Androstenediol treatment significantly increased monocyte levels at days 4, 7, and 14 and, similarly, increased red blood cell, hemoglobin, and platelet counts. Flow cytometry analysis 14 days after radiation and AED treatment demonstrated an increase (p < 0.05) in bone marrow cells counts. Ex vivo osteoclastogenesis studies show that AED treatment is necessary and advantageous for the development and restoration of osteoclastogenesis after radiation exposure. These findings clearly show that androstenediol functions as a countermeasure to remedy hematopoeitic injury mediated by high LET iron ion radiation. Presently, no other agent has been shown to have such properties.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

ATM-Dependent Hyper-Radiosensitivity in Mammalian Cells Irradiated by Heavy Ions

Purpose: Low-dose hyper-radiosensitivity (HRS) and the later appearing radioresistance (termed induced radioresistance [IRR]) was mainly studied in low linear energy transfer (LET) radiation with survival observation. The aim of this study was to find out whether equivalent hypersensitivity occurred in high LET radiation, and the roles of ataxia telangiectasia mutated (ATM) kinase. Methods and Materials: Survival and mutation were measured by clonogenic assay and HPRT mutation assay. ATM Ser1981 activation was detected by Western blotting and immunofluorescent staining. Pretreatment of specific ATM inhibitor (10 {mu}M KU55933) and activator (20 {mu}g/mL chloroquine) before carbon radiation were adopted to explore the involvement of ATM. The roles of ATM were also investigated in its G2/M checkpoint function with histone H3 phosphorylation analysis and flow cytometric assay, and DNA double strand break (DSB) repair function measured using {gamma}-H2AX foci assay. Results: HRS/IRR was observed with survival and mutation in normal human skin fibroblast cells by carbon ions, while impaired in cells with intrinsic ATM deficiency or normal cells modified with specific ATM activator or inhibitor before irradiation. The dose-response pattern of ATM kinase activation was concordant with the transition from HRS to IRR. The ATM-dependent 'early' G2 checkpoint arrest and DNA DSB repair efficiency could explain the difference between HRS and IRR. Conclusions: These data demonstrate that the HRS/IRR by carbon ion radiation is an ATM-dependent phenomenon in the cellular response to DNA damage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of neutron measurement in high gamma field using new nuclear emulsion

To precisely measure the neutron emissions from a spent fuel assembly of a fast breeder reactor, we formed nuclear emulsions based on a non-sensitized Oscillation Project with Emulsion tracking Apparatus (OPERA) film with AgBr grain sizes of 60, 90, and 160 nm. The efficiency for {sup 252}Cf neutron detection of the new emulsion was calculated to be 0.7 x 10{sup -4}, which corresponded to an energy range from 0.3 to 2 MeV and was consistent with a preliminary estimate based on experimental results. The sensitivity of the new emulsion was also experimentally estimated by irradiating with 565 keV and 14 MeV neutrons. The emulsion with an AgBr grain size of 60 nm had the lowest sensitivity among the above three emulsions but was still sensitive enough to detect protons. Furthermore, the experimental data suggested that there was a threshold linear energy transfer of 15 keV/{mu}m for the new emulsion, below which no silver clusters developed. Further development of nuclear emulsion with an AgBr grain size of a few tens of nanometers will be the next stage of the present study. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alternative methods for degradation studies by alpha radiolysis: tributyl phosphate and CMPO

Solvent extraction separation processes used in the recycling of used nuclear fuel are susceptible to radiolytic damage from radioactive isotopes present in used fuel. Studying the respective effects on matter of both low linear energy transfer (LET) radiation such as gamma radiation and high LET such as alpha radiation will allow for accurate prediction and modeling of process performance losses with respect to dose. The effects of gamma radiation on solvent extraction ligands have been more extensively studied than the effects of alpha radiation due to the inherent difficulty in producing a sufficient and confluent dose of alpha particles within a sample without leaving the sample contaminated with long lived radioactive isotopes. We have developed a method for studying the effects of high LET radiation in situ via {sup 10}B activation and the high LET particles that result from the {sup 10}B(n,a){sup 7}Li reaction which follows. In this study we applied this method to organic solutions of tributyl phosphate (TBP) and CMPO (compound octylphenyl-N, N-diisobutyl-carbamoyl methyl phosphine oxide) representing the PUREX and TRUEX processes respectively. Rates of degradation of TBP and CMPO and their respective degradation products in the presence of both high and low LET radiation are presented and compared to values reported in the literature. Preliminary data appears to show decreased degradation of CMPO in the presence of an aqueous acidic phase, which agrees with other studies performed on TBP solutions. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ultra Low Level Environmental Neutron Measurements Using Superheated Droplet Detectors

Through the application of superheated droplet detectors (SDDs), the SIMPLE project for the direct search for dark matter (DM) reached the most restrictive limits on the spin-dependent sector to date. The experiment is based on the detection of recoils following WIMP-nuclei interaction, mimicking those from neutron scattering. The thermodynamic operation conditions yield the SDDs intrinsically insensitive to radiations with linear energy transfer below ∼150 keVμm{sup -1} such as photons, electrons, muons and neutrons with energies below ∼40 keV. Underground facilities are increasingly employed for measurements in a low-level radiation background (DM search, gamma-spectroscopy, intrinsic soft-error rate measurements, etc.), where the rock overburden shields against cosmic radiation. In this environment the SDDs are sensitive only to α-particles and neutrons naturally emitted from the surrounding materials. Recently developed signal analysis techniques allow discrimination between neutron and α-induced signals. SDDs are therefore a promising instrument for low-level neutron and α measurements, namely environmental neutron measurements and α-contamination assays. In this work neutron measurements performed in the challenging conditions of the latest SIMPLE experiment (1500 mwe depth with 50-75 cm water shield) are reported. The results are compared with those obtained by detailed Monte Carlo simulations of the neutron background induced by {sup 238}U and {sup 232}Th traces in the facility, shielding and detector materials. Calculations of the neutron energy distribution yield the following neutron fluence rates (in 10{sup -8} cm{sup -2}s{sup -1}): thermal (<0.5 eV): 2.5; epithermal (0.5 eV-100 keV): 2.2; fast (>1 MeV): 3.9. Signal rates were derived using standard cross sections and codes routinely employed in reactor dosimetry. The measured and calculated neutron count rates per unit of active mass were 0.15 ct/kgd and 0.33 ct/kg-d respectively. As the major signal contribution (98%) originates from radio-impurities in the detector container, alternative materials will be employed in future devices. Latest results regarding the improvement of the detector characterization accuracy towards its application in environmental neutron detection are in progress and will be described. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute Dosimetry Model of the University of Washington Clinical Neutron Therapy System (CNTS)

The University of Washington (UW) Clinical Neutron Therapy System (CNTS) generates a fast neutron beam using 50.5 MeV protons incident on a beryllium target. The CNTS is mainly used for fast neutron therapy in the treatment of cancer but is also used for radiation effects testing and the production of rare isotopes, or isotopes with a short half-life, for medical imaging and therapy. The accelerator and treatment head is modeled using the MCNP6 Monte Carlo code to enable beam characterization (neutron and photon fluence, linear energy transfer, secondary particle production), study the behavior of neutron dosimeters and ionization chamber (IC) responses, and to conduct first principle studies of the relative biological effectiveness (RBE) of fast neutrons compared to {sup 60}Co γ-rays. Measurements of neutron dose in selected CNTS fields were made using a model-17 ion chamber (IC-17) flowing methane-based, tissue-equivalent (TE) gas. As a first approximation, we compared IC-17 measurements to the MCNP calculated dose in a thin layer of water at selected locations along the central axis of the beam. To examine the impact of the composition of the chamber fill-gas and the chamber design characteristics, we also developed a high-resolution (∼ 50 μm) MCNP model of the IC-17 from a computerized tomography (CT) scan. Initial results indicate that the dose response of the IC-17 ion chamber is up to 30% larger (smaller?) compared to the dose to water for neutrons with energies >20 MeV. Differences in chamber and water response as large as 800% occur for neutrons with kinetic energies below 1 keV. The simulations of IC-17 response (and dose to water) for CNTS fast neutron spectra match measured doses within 4.6% for all field sizes and irradiation geometries considered. This reported studies provide additional evidence establishing use of the IC-17 ion chamber model or a thin layer of water as a reasonable surrogate for CNTS fast neutron dose calculations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cross-linking of polytetrafluoroethylene during room-temperature irradiation

Exposure of polytetrafluoroethylene (PTFE) to {alpha}-radiation was investigated to detennine the physical and chemical effects, as well as to compare and contrast the damage mechanisms with other radiation types ({beta}, {gamma}, or thermal neutron). A number of techniques were used to investigate the chemical and physical changes in PTFE after exposure to {alpha}-radiation. These techniques include: Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), and fluorescence spectroscopy. Similar to other radiation types at low doses, the primary damage mechanism for the exposure of PTFE to {alpha}-radiation appears to be chain scission. Increased doses result in a change-over of the damage mechanism to cross-linking. This result is not observed for any radiation type other than {alpha} when irradiation is performed at room temperature. Finally, at high doses, PTFE undergoes mass-loss (via smallfluorocarbon species evolution) and defluorination. The amount and type of damage versus sample depth was also investigated. Other types of radiation yield damage at depths on the order of mm to cm into PTFE due to low linear energy transfer (LET) and the correspondingly large penetration depths. By contrast, the {alpha}-radiation employed in this study was shown to only induce damage to a depth of approximately 26 {mu}m, except at very high doses.

36 MATERIALS SCIENCE↗

Identification of a network of nonlinear interactions as a mechanism triggering the onset of edge localized modes

Edge localized modes (ELMs) remain a critical issue for the lifetime of in-vessel components of fusion reactors such as ITER. We study ELMs triggered when the pedestal parameters are below the peeling-ballooning limit. These ELMs occur while the pedestal recovers after an ELM crash. We identify a mechanism by which a non-linear perturbation involving many active triads—a network of non-linear interactions – leads to the triggering of these ELMs. Each active triad leads to the non-linear transfer of energy between three waves, such that the network of non-linear interactions lead to a transfer of energy between many waves. The triggering of this non-linear perturbation systematically coincides with a pedestal perturbation induced by the neutral beam injection beams and localized near the magnetic surface of safety factor q = 5. Among the non-linear interactions detected during the ELM by a bi-coherence analysis, the most active triad involves a slow frequency that is qualitatively consistent with a geodesic acoustic mode located at the same location, i.e., near the q = 5 surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MO-F-CAMPUS-T-03: Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector

Purpose: Liquid scintillators have been shown to provide fast and high-resolution measurements of radiation beams. However, their linear energy transfer-dependent response (quenching) limits their use in proton beams. The purpose of this study was to develop a simple and fast method to verify the range, spread-out Bragg peak (SOBP) width, and output of a passive-scattering proton beam with a liquid scintillator detector, without the need for quenching correction. Methods: The light signal from a 20×20×20 cm3 liquid scintillator tank was collected with a CCD camera. Reproducible landmarks on the SOBP depth-light curve were identified which possessed a linear relationship with the beam range and SOBP width. The depth-light profiles for three beam energies (140, 160 and 180 MeV) with six SOBP widths at each energy were measured with the detector. Beam range and SOBP width calibration factors were obtained by comparing the depth-light curve landmarks with the nominal range and SOBP width for each beam setting. The daily output stability of the liquid scintillator detector was also studied by making eight repeated output measurements in a cobalt-60 beam over the course of two weeks. Results: The mean difference between the measured and nominal beam ranges was 0.6 mm (σ=0.2 mm), with a maximum difference of 0.9 mm. The mean difference between the measured and nominal SOBP widths was 0.1 mm (σ=1.8 mm), with a maximum difference of 4.0 mm. Finally an output variation of 0.14% was observed for 8 measurements performed over 2 weeks. Conclusion: A method has been developed to determine the range and SOBP width of a passive-scattering proton beam in a liquid scintillator without the need for quenching correction. In addition to providing rapid and accurate beam range and SOBP measurements, the detector is capable of measuring the output consistency with a high degree of precision. This project was supported in part by award number CA182450 from the National Cancer Institute.

07 ISOTOPE AND RADIATION SOURCES↗