Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOOPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Exploring Standing and Reflected Slow-mode Waves in Flaring Coronal Loops: A Parametric Study Using 2.5D MHD Modeling

Abstract Recent observations of reflected propagating and standing slow-mode waves in hot flaring coronal loops have spurred our investigation into their underlying excitation and damping mechanisms. To understand these processes, we conduct 2.5D magnetohydrodynamic (MHD) simulations using an arcade active region model that includes a hot and dense loop. Our simulations allow for in-depth parametric investigations complementing and expanding our previous 3D MHD modeling results. We excite these waves using a large-amplitude, flow pulse applied at one footpoint of the loop in two distinct models as motivated by observations from the Solar Dynamics Observatory/Atmospheric Imaging Assembly (SDO/AIA). The first model (Model 1) incorporates classical compressive viscosity coefficient, while the second model (Model 2) adopts a 10-times enhanced viscosity coefficient. We obtain the following major results: (1) Our 2.5D MHD simulations reinforce previous conclusions derived from 1D and 3D MHD models that significantly enhanced viscosity is crucial for the rapid excitation of standing slow waves with damping times consistent with observations by Wang et al. (2015). (2)We uncover that nonlinearity in Model 1 delays the conversion of a reflected propagating wave into a standing wave. In contrast, Model 2 exhibits a much weak influence of nonlinearity on the excitation time of standing waves, thanks to the suppression of these effects by enhanced viscosity. (3) Our results reveal that the transverse temperature structure holds more influence on wave behavior than the density structure. In Model 1, increased loop temperature contrast significantly enhances wave trapping within the structure, mitigating the impact of temperature-dependent viscous damping. Conversely, in Model 2, the impact of temperature structure on wave behavior weakens in comparison to the effect of viscosity. (4) Model 1 displays evident nonlinear coupling to the fast and kink magnetoacoustic waves and pronounced wave leakage into the corona. Model 2 exhibits significantly weaker effects in this regard. Analyzing three observed wave events by SDO/AIA aligns with Model 2 predictions, providing further support for the substantial viscosity increase. Our 2.5D study unravels the complex interplay of wave-flow phenomena and nonlinear processes in coronal loops, extending our previous 1D modeling results to incorporate more realistic loop geometry. This provides insights into scenarios where 3D effects may be neglected, thereby enhancing our understanding of the intricate dynamics of the solar corona.

Tongjiang Wang↗

Ground loop locator

Described is a ground loop locator. A readout on the ground loop locator indicates the presence of a ground loop when a ground loop exists in conductors linked by a current transformer of an exciter portion and a Rogowski coil of a detector portion. Also described are how to make and use the ground loop locator and methods of use for the ground loop locator.

42 ENGINEERING↗

On gauge amplitudes first appearing at two loops

We study scattering amplitudes in massless non-abelian gauge theory where all outgoing gluons have positive helicity. It has been argued recently by Costello that for a particular fermion representation (8 fundamentals plus one antisymmetric-tensor representation in SU(N)) the one-loop amplitudes vanish identically. We show that this vanishing leads to previously-observed identities among one-loop color-ordered partial amplitudes. We then turn to two loops, where Costello has computed the all-plus amplitudes for this theory, as rational functions of the kinematics for any number of gluons using the celestial chiral algebra (CCA) bootstrap. We show that in dimensional regularization, these two-loop amplitudes are not rational, and they are not even finite as ϵ → 0. However, the finite remainder for four gluons agrees with the formula by Costello. In addition, we provide a mass regulator for the infrared-divergent loop integrals; with this regulator, the CCA bootstrap formula is recovered exactly. Finally, we use the CCA bootstrap to compute the double-trace terms in the theory at two loops for an arbitrary number of gluons.

Dixon, Lance J↗

Techno-Economic Performance of Eavor Loop 2.0

This project evaluated techno-economic performance for a sample Eavor-Loop 2.0 design for electricity production and direct-use heating. The Eavor-Loop 2.0 design investigated is a 7.5-km deep closed-loop geothermal system consisting of 12 laterals for a total of more than 90 km of downhole well and lateral length. Both a high geothermal gradient scenario of 60 degrees C/km and a low geothermal gradient scenario of 30 degrees C/km were considered. With pure water injected at 60 degrees C and 80 kg/s, reservoir simulations with the Slender-Body Theory simulator indicate average production temperatures over a 30-year lifetime of ~125 degrees C and ~210 degrees C for the low and high geothermal gradient scenario, respectively. These correspond to heat production of ~22 M Wth and ~51 M Wth, respectively. Using IPSEpro simulations, we find average power production of ~2.2 M We and ~8.6 M We, respectively, for a subcritical organic Rankine cycle power plant with air-cooled condensers. Cost estimates indicate the overall capital and levelized costs are dominated by the lateral drilling cost. Obtaining a levelized cost of electricity below $70/M Wh requires a geothermal gradient of 60 degrees C/km, a discount rate below 9%, and lateral drilling cost below $400/m. A well cost model indicates that ~$400/m for the Eavor-Loop 2.0 design investigated can be obtained for a drilling rate of penetration about 40 ft/hr (with bit life of 50 hours), and omitting casing and cement. Traditional (geothermal) well drilling has achieved these drilling rate conditions, including the Utah FORGE project where the rate of penetration has exceeded 50 ft/hr in granite. However, it is unclear if these conditions are still valid for drilling the Eavor-Loop 2.0 laterals (i.e., ~82 km of laterals at 4 to 7.5-km vertical depth with rock temperatures up to 460 degrees C), as such downhole completion has never been developed before. Competitive levelized cost of heat values ($1.2-$8.2/GJ) are calculated, even for the low geothermal gradient scenario (30 degrees C/km) and lateral drilling cost of $600/m.

advanced geothermal system↗

The Innovation of I-Loop

The closing and decommissioning of Halden Boiling Water Reactor in Norway resulted in the loss of many nuclear irradiation testing facilities, notably those providing boiling water reactor (BWR) environments. To lighten the loss of such an important asset, the Advanced Test Reactor (ATR) is being called upon. The recent overhaul of the ATR’s core and the installation of the new Top Head Closure Plate now makes it possible to utilize the ATR’s I-loop locations for I-Loop Tube test facilities. Similar to the current in-pile tube facilities, these new I-Loop facilities will capitalize on the available space and neutron flux the ATR generates in this region of the core for fuels and materials testing. Current efforts are underway to add new PWR and BWR I-Loop Tube facilities to the I-Loop positions for these purposes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Bootstrapping the Three-Loop Hexagon

We consider the hexagonal Wilson loop dual to the six-point MHV amplitude in planar N = 4 super Yang-Mills theory. We apply constraints from the operator product expansion in the near-collinear limit to the symbol of the remainder function at three loops. Using these constraints, and assuming a natural ansatz for the symbol's entries, we determine the symbol up to just two undetermined constants. In the multi-Regge limit, both constants drop out from the symbol, enabling us to make a non-trivial confirmation of the BFKL prediction for the leading-log approximation. This result provides a strong consistency check of both our ansatz for the symbol and the duality between Wilson loops and MHV amplitudes. Furthermore, we predict the form of the full three-loop remainder function in the multi-Regge limit, beyond the leading-log approximation, up to a few constants representing terms not detected by the symbol. Our results confirm an all-loop prediction for the real part of the remainder function in multi-Regge 3 {yields} 3 scattering. In the multi-Regge limit, our result for the remainder function can be expressed entirely in terms of classical polylogarithms. For generic six-point kinematics other functions are required.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of irradiation induced dislocation loops on thermal conductivity in ceramics

Experimental work aimed at understanding the role of dislocation loops in limiting phonon mediated thermal transport in ceramics is presented. Faulted dislocation loops, having diameters of a few nanometers, were introduced by irradiating a polycrystalline cerium dioxide sample with 1.6 MeV protons at 700°C. XRD analysis indicated that irradiated samples retained their crystalline structure and exhibit very little lattice expansion suggesting a low concentration of point defects. Additionally, further microstructure characterization using transmission electron microscopy revealed that interstitial type faulted dislocation loops were primarily created as expected for these irradiation conditions. Thermal conductivity of the damaged layer was measured using a modulated thermoreflectance approach. Analysis of the experimental data using the classical Klemens-Callaway approach reveals that the conductivity reduction is primarily due to dislocation loops, while point defects and voids play only a minor role. These results provide experimental confirmation that faulted loops offer a unique arrangement for displaced atoms that leads to an unusually large reduction of thermal conductivity.

36 MATERIALS SCIENCE↗

EXPERIMENTAL AND MODELLING ANALYSIS OF A LARGE-SCALE TWO-PHASE LOOP THERMOSYPHON

Liquid pumping requires large quantities of electrical energy, including about 7% of the energy of building heating, ventilation, and air conditioning (HVAC) systems. To replace pumped condenser-cooling tower water loops with a passive alternative system, we implemented a commercial-scale two-phase loop thermosyphon (TPLT). The unit consists of a 13 m riser integrated with a commercially available cooling tower and circulation water heater that simulates heat loads up to 25 kW. In addition to providing passive cooling capabilities, the cooling tower unit is also maintenance free, reliable, and can operate in both dry and wet modes. This study characterizes the performance (temperature difference between the evaporator and condenser) and the two-phase flow behavior of the loop under various refrigerant charges. Sight glasses installed throughout the loop are used to identify the operating flow regimes in the riser and downcomer. Over the range of operating conditions, we identified that there is an optimal refrigerant charge range for a specific heat load at which near-isothermal operation can be achieved. We further developed a model to predict the operating flow rate and gravitational height in the downcomer and compared it with the experimental data. The results show that the model agrees with the experimental data, in particular the threshold gravitational head height at which there will be subcooled liquid at the condenser exit, indicating that it can be used as a predictive tool for identifying the optimal loop charge for a given heat load.

Loop thermosyphon, passive two phase↗

Strategic need for a multi-purpose thermal hydraulic loop for support of advanced reactor technologies

This report presents a conceptual design for a new high-temperature multi fluid, multi loop test facility for the INL to support thermal hydraulic, materials, and thermal energy storage research for nuclear and nuclear-hybrid applications. In its initial configuration, the facility will include a high-temperature helium loop, a liquid salt loop, and a hot water/steam loop. The three loops will be thermally coupled through an intermediate heat exchanger (IHX) and a secondary heat exchanger (SHX). Research topics to be addressed with this facility include the characterization and performance evaluation of candidate compact heat exchangers such as printed circuit heat exchangers (PCHEs) at prototypical operating conditions, flow and heat transfer issues related to core thermal hydraulics in advanced helium-cooled and salt-cooled reactors, and evaluation of corrosion behavior of new cladding materials and accident-tolerant fuels for LWRs at prototypical conditions. Based on its relevance to advanced reactor systems, the new facility has been named the Advanced Reactor Technology Integral System Test (ARTIST) facility. Research performed in this facility will advance the state of the art and technology readiness level of high temperature intermediate heat exchangers (IHXs) for nuclear applications while establishing the INL as a center of excellence for the development and certification of this technology. The thermal energy storage capability will support research and demonstration activities related to process heat delivery for a variety of hybrid energy systems and grid stabilization strategies. Experimental results obtained from this research will assist in development of reliable predictive models for thermal hydraulic design and safety codes over the range of expected advanced reactor operating conditions. Proposed/existing IHX heat transfer and friction correlations and criteria will be assessed with information on materials compatibility and instrumentation needs. The experimental database will guide development of appropriate predictive methods and be available for code verification and validation (V&V) related to these systems.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Integrated Energy Systems Prototype Human-System Interface for a Steam Extraction Loop System to Support Joint Electricity-Hydrogen Flexible Operations

Due to increasing economic competition from renewables and combined-cycle natural gas plants, nuclear power plants are looking toward flexible operations to enhance their cost competitiveness. The Integrated Energy Systems project under the Light Water Reactor Sustainability program of the U.S. Department of Energy focuses on joint electricity-hydrogen flexible operations. Joint electricity-hydrogen flexible operations entail the nuclear power plant diverting thermal energy via main steam to a hydrogen production plant located nearby. The steam serves to enhance the efficiency of the hydrogen production. Furthermore, high temperature electrolysis requires a large amount of electricity, which the plant can also provide. The plant provides steam and electricity to the hydrogen plant throughout the day, but during peak demand hours the nuclear power plant returns to solely providing electricity to meet the high demand. Through this flexible concept of operations, the plant can optimize the thermal energy it produces without having to maneuver the power of the plant. This report documents the human factors process to design and develop a prototype human-system interface for the steam extraction loop that serves as the conduit between the nuclear power plant and the adjacent hydrogen plant. The design process followed the human factors guidelines set by NUREG-0711, Human Factors Engineering Program Review Model (O’Hara, Higgins, & Fleger, 2012), and expanded upon by the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE; Boring, Ulrich, Joe, & Lew, 2015; Boring, Lew, & Ulrich, 2016). The design process entailed operator interviews to determine the concept of operations for the steam extraction loop, a review and adaptation of digital interface design concepts developed by the team in prior projects, an iterative design process, and reviews conducted by both operators and human factors experts. Several versions of the prototype human-system interface were developed. Operators were interviewed to determine what design features they found useful and would like to see in the interface. The design underwent a review by human factors experts against NUREG-0700, Human Interface Design Review Guidelines (U.S. Nuclear Regulatory Commission, 2019), to ensure compliance with the latest human factors standards for digital interfaces in nuclear applications. The design was then prototyped as a functional windows-based application integrated with the Generic Pressurized Water Reactor simulator modified to include the steam extraction loop. The simulation is supported by the Human Systems Simulation Laboratory at Idaho National Laboratory, which supports operator-in-the-loop testing. This is an ongoing project and the next phase of the project entails performing an operator-in-the-loop usability study to evaluate the interface and examine the proposed concept of operations to extraction steam from the nuclear power plant for delivery to the coupled hydrogen production plant.

99 GENERAL AND MISCELLANEOUS↗

Thermal performance of a multi-evaporator loop heat pipe with thermal masses and thermal electrical coolers

This paper describes thermal performance of a loop heat pipe (LHP) with two evaporators and two condensers in ambient testing. Each evaporator has an outer diameter of 15mm and a length of 76mm, and has an integral compensation chamber (CC). An aluminum mass of 500 grams is attached to each evaporator to simulate the instrument mass. A thermal electric cooler (TEC) is installed on each CC to provide heating as well as cooling for CC temperature control. A flow regulator is installed in the condenser section to prevent vapor from going back to the evaporators in the event that one of condenser is fully utilized. Ammonia was used ad the working fluid. Tests conducted included start-up, power cycle, heat load sharing, sink temperature cycle, operating temperature control with TECs, and capillary limit tests. Experimental data showed that the loop could start with a heat load of less than 1OW even with added thermal masses. The loop operated stably with even and uneven evaporator heat loads, and even and uneven condenser sink temperatures. The operating temperature could be controlled within +/-0.5K of the set point temperature using either or both TECs, and the required TEC control heater power was less than 2W under most test conditions. Heat load sharing between the two evaporators was also successfully demonstrated. The loop had a heat transport capability of 120W to 140W, and could recover from a dry-out when the heat load was reduced. The 500-gram aluminum mass on each evaporator had a negligible effect on the loop operation. Existing LHPs servicing the orbiting spacecraft have a single evaporator with an outer diameter of about 25mm. Important performance characteristics demonstrated by this LHP included: 1) Operation of an LHP with 15mm diameter evaporators; 2) Robustness and reliability of an LHP with multiple evaporators and multiple condensers under various test conditions; 3) Heat load sharing among LHP evaporators; 4) Effectiveness of TECs in controlling the LHP operating temperature; and 5) Effectiveness of the flow regulator in preventing vapor from going back the evaporators.

loop heat pipes↗

Loop Heat Pipe Startup Behaviors

A loop heat pipe must start successfully before it can commence its service. The start-up transient represents one of the most complex phenomena in the loop heat pipe operation. This paper discusses various aspects of loop heat pipe start-up behaviors. Topics include the four start-up scenarios, the initial fluid distribution between the evaporator and reservoir that determines the start-up scenario, factors that affect the fluid distribution between the evaporator and reservoir, difficulties encountered during the low power start-up, and methods to enhance the start-up success. Also addressed are the thermodynamic constraint between the evaporator and reservoir in the loop heat pipe operation, the superheat requirement for nucleate boiling, pressure spike and pressure surge during the start-up transient, and repeated cycles of loop start-up andshutdown under certain conditions.

Loop Heat Pipes↗

Simulated Time Lags of Hinode/XRT and SDO/AIA Lightcurves as an Indication of Loop Heating Scenario

The precise nature of the heating mechanism in coronal loops is still a matter of enormous research. We present the results from a 1D hydrodynamic loop simulation of a coronal loop which was run using different parameters such as loops length (50, 200 and 500 Mm), maximum temperature reached (3MK and 10 MK0, and abundances. For each scenario the model outputs were used to calculate the corresponding lightcurves as seen by XRT/Be-thin and various EUV AIA channels. The lag time between the peak of these lightcurves was computed and tested using cross-correlation and plotted as a function of loop length.

Loop heating↗

Automated Scenario Generation for Human-in-the-Loop Simulations

Automated Multi-Aircraft Control System scenario generation for Human-in-the-Loop evaluations of air traffic management concepts is described. Methods for analyzing and comparing the seed-scenario generated using the automated process and the Human-in-the-Loop-scenario designed to meet the experiment objectives are discussed. The main findings are: (1) many of the characteristics of the seed-scenario used for constructing the Human-in-the-Loop-scenario are preserved in the Human-in-the-Loop Scenario, (2) landing characteristics of the traffic generated by the Multi-Aircraft Control System using the input scenario compare reasonably well with that intended in the input scenario, and (3) many of desired characteristics of the Human-in-the-Loop-scenario can be achieved by further automation.

SMART-NAS Testbed↗

SULI Internship Deliverables (Flow Orifice Design: Measuring Degas Flow of Experiment Loops at the Advanced Test Reactor)

These deliverables present a design for a new orifice flow meter to be installed in three experiment loops at the Advanced Test Reactor. The current configuration of the experiment loop system has an orifice that is not properly sized to the low flow rates of the degas line of the pressurizer system, causing inaccurate flow measurements. Under consideration of flow conditions and system constraints, an iterative procedure was utilized to determine the optimal sizing for a new orifice. This orifice is designed to accurately and precisely measure the flow rate of the degas line, which will consequently improve control of the pressure and chemistry of the loop pressurizer system. The scope of this project includes recommendations for orifice sizing, material, flange type, face type, and installation location on the loop piping spools. The design is suitable for experiment loops 1D-N, 2B-SE, and 2D-SW and meets all necessary standards.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo: Preprint

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. Using GHEDesigner, a lookup table was created to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on agent energy bills. This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of different costing and pricing future scenarios. While the code is still under development and nationwide simulations are ongoing, initial results for two states are provided. Future work includes expanding the module to consider mixed residential and commercial districts and considering multiple costing scenarios.

ambient temperature loop↗

National Modeling of Geothermal District Energy Systems with Ambient-Temperature Loops Using dGeo

Geothermal district energy systems (DES) with ambient-temperature loops, also known as thermal energy networks, are one option for decarbonizing space heating and cooling loads. Geothermal fifth-generation DES include an "ambient" temperature thermal loop that connects heat pumps at each building with thermal balancing sources such as geothermal borehole fields. Heating and cooling are provided via a water-source heat pump at each end-user. This project seeks to analyze the nationwide potential for ambient-temperature loop districts by creating a new module within the Distributed Geothermal Market Demand Model (dGeo). dGeo is an agent-based modeling tool for distributed geothermal resources; it can investigate potential on a nationwide or statewide scale using geospatial data for all 50 states and thermal demands for existing buildings. This process allows for high-level estimates of technical and economic potential for ambient-temperature loop districts across the United States. A lookup table was created using GHEDesigner to size borehole fields for different thermal loads and ground conditions experienced across the country. A cost and financing structure, along with incentives, were applied. Cost estimates include costs for the distribution network, borehole field installation and operation, and circulation pump operation, while savings are calculated based on energy bills for building owners (agents). This newly developed module can be used for assessing which areas of the country have the highest potential for agent benefits from ambient-temperature loop installation and assess the impact of future cost and price scenarios. Initial results for statewide analysis (for Vermont) and nationwide (for United States) are provided. Future work includes expanding the module to consider mixed residential and commercial districts as well as evaluating multiple cost scenarios.

ambient-temperature loop↗

The complete two-loop integrated jet thrust distribution in soft-collinear effective theory

In this work, we complete the calculation of the soft part of the two-loop integrated jet thrust distribution in e+e- annihilation. This jet mass observable is based on the thrust cone jet algorithm, which involves a veto scale for out-of-jet radiation. The previously uncomputed part of our result depends in a complicated way on the jet cone size, r, and at intermediate stages of the calculation we actually encounter a new class of multiple polylogarithms. We employ an extension of the coproduct calculus to systematically exploit functional relations and represent our results concisely. In contrast to the individual contributions, the sum of all global terms can be expressed in terms of classical polylogarithms. Our explicit two-loop calculation enables us to clarify the small r picture discussed in earlier work. In particular, we show that the resummation of the logarithms of r that appear in the previously uncomputed part of the two-loop integrated jet thrust distribution is inextricably linked to the resummation of the non-global logarithms. Furthermore, we find that the logarithms of r which cannot be absorbed into the non-global logarithms in the way advocated in earlier work have coefficients fixed by the two-loop cusp anomalous dimension. We also show that in many cases one can straightforwardly predict potentially large logarithmic contributions to the integrated jet thrust distribution at L loops by making use of analogous contributions to the simpler integrated hemisphere soft function.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗