Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Krypton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Destructive PIE and Safety Testing of Six AGR-5/6/7 Capsule 2 Compacts

This study evaluates fission product retention and particle failure mechanisms in AGR-5/6/7 Capsule 2 uranium carbide and uranium oxide (UCO) tristructural isotropic (TRISO) fuel under high-temperature gas reactor accident-relevant conditions using high-temperature safety tests and destructive post-irradiation examination. Three Capsule 2 compacts were held isothermally at 1600°C for approximately 300 hours and one compact at 1800°C for approximately 300 hours; two additional compacts were examined in the as-irradiated state. Post-test deconsolidation–leach–burn–leach (DLBL) quantified nuclide inventories in matrix and particles. Individual particles were surveyed for radioisotope inventories, and microanalytical approaches resolved microstructural evolution and fission product distributions within the coating layers. At 1600°C, no krypton was detected above the minimum detectable limit, and cesium releases were far below a single particle equivalent, indicating the absence of full TRISO failure or SiC failures. Silver releases were limited and primarily reflected depleted post-irradiation inventories, consistent with prior compact-level exams indicating substantial in-pile 110m Ag loss. At 1800°C, cumulative 134 Cs release of approximately 2.5 particle equivalents and delayed 85 Kr totaling approximately 0.53 particle equivalents were consistent with one full TRISO failure and two SiC failures. Europium and strontium releases were roughly one order of magnitude higher than at 1600°C and comparable to AGR-1/AGR-2 high-temperature tests, with sustained late-hold rates indicating diffusion through intact coatings coupled with matrix depletion. Overall, AGR-5/6/7 Capsule 2 UCO fuel demonstrated fission product retention during safety testing consistent with prior AGR campaigns, while distinctive in-pile 110m Ag depletion and measurable 1600°C europium loss motivate targeted follow-on studies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Functional Membranes for Noble Gas Management: Fabrication and Testing of Membranes on Porous Support

We selected several porous materials including PNW-24, CC3, SAPO-34, SAPO-56 and PNW-6, as the basis for fabricating membranes for Kr/Xe separation. Initially, we synthesized powder samples of the candidates and confirmed their crystallinity and morphology with X-ray diffraction and microscopy. In the case of PNW-24 and PNW-6, we further confirmed its Xe selectivity through Xe and Kr adsorption experiments, while we relied on literature reports for CC3, SAPO-34 and SAPO-56. We subsequently proceeded to fabricate membranes on porous alumina supports using techniques such as seeded-assisted secondary growth, in-situ growth and solution-processed method. PXRD on the membranes verified that the structures were well-grown on the surface of alumina support, while SEM provided visual confirmation of particle morphology. Importantly, defects were not visually observed in the fabricated membranes, which was further verified with pressure retention tests. We analyzed the separation performance of the synthesized membranes using a dilute gas mixture comprising of xenon, krypton and argon. We focused on PNW-6 to optimize the synthesis reaction time and study the effects of time on gas separation. While more research is necessary to reach a comprehensive conclusion, in alignment with our milestones, we have successfully achieved our goals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Review of Distribution Coefficients for Radionuclides in Carbonate Minerals

An understanding of the transport of radionuclides in carbonate minerals is necessary to be able to predict the fate of (and potentially remediate) radionuclides in the environment. In some environments, carbonate minerals such as calciate, aragonite, dolomite and limestone are present and an understanding of the sorption of radionuclides in these carbonate minerals is therefore advantageous. A list of the radionuclides of interest is given in Table 1. The distribution coefficient, K{sub d} is defined as the ratio of the contaminant concentration bound on the solid phase to the contaminant concentration remaining in the liquid phase at equilibrium. Some authors report distribution coefficients and other report partition coefficients, the data presented in this work assumes equality between these two terms, and data are presented and summarized in this work as logarithmic distribution coefficient (log K{sub D}). Published literature was searched using two methods. Firstly, the JNC Sorption Database, namely Shubutani et al (1999), and Suyama and Sasamoto (2004) was used to select elements of interest and a number of carbonate minerals. Secondly, on-line literature search tools were used to locate relevant published articles from 1900 to 2009. Over 300 data points covering 16 elements (hydrogen, carbon, calcium, nickel, strontium, technetium, palladium, iodine, cesium, samarium, europium, holmium, uranium, neptunium, plutonium and americium) were used to calculate an average and range of log K{sub d} values for each element. Unfortunately, no data could be found for chlorine, argon, krypton, zirconium, niobium, tin, thorium and curium. A description of the data is given below, together with the average, standard deviation, minimum, maximum and number of inputs for radionuclide K{sub d} values for calcite, aragonate, limestone, dolomite and unidentified carbonate rocks in Table 2. Finally, the data are condensed into one group (carbonate minerals) of data for each element of interest in Table 3.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synchrotron X-Ray Interrogation of Turbulent Gas–Liquid Mixing in Cryogenic Rocket Sprays

The atomization and vaporization of liquid jets within turbulent gaseous flows are characterized by the mixing phenomena occurring over a wide range of spatiotemporal scales. This creates a complex, turbid medium that is not easily interrogated using conventional optical-measurement techniques. In the current study, the optically dense, multiphase flow created by a cryogenic liquid jet injected into a turbulent gaseous coflow is probed using high-speed (MHz) X-ray radiography from a focused, narrowband synchrotron source to resolve the internal cascade of scales and the evolution to isotropic, homogeneous turbulence. Changes in the spectral characteristics for different flow conditions are furthermore correlated with changes in the spatial distributions of the liquid and gas phases within the spray using simultaneous X-ray radiography and tracer (krypton) fluorescence. It is found that an increase in entrainment and mixing infers an evolution in spectral characteristics toward the well-known -5/3 law of energy dissipation in the context of the classical Kolmogorov theory. Finally, these data demonstrate the utility of the synchrotron-based X-ray radiography and fluorescence for uncovering the internal, turbulent mixing processes in multiphase and optically dense flows.

42 ENGINEERING↗

Attosecond Time Delay Trends across the Isoelectronic Noble Gas Sequence

The analysis and measurement of Wigner time delays can provide detailed information about the electronic environment within and around atomic and molecular systems, with one the key differences being the lack of a long-range potential after a halogen ion undergoes photoionization. In this work, we use relativistic random-phase approximation to calculate the average Wigner delay from the highest occupied subshells of the atomic pairings (2p, 2s in Fluorine, Neon), (3p, 3s in Chlorine, Argon), (4p, 4s, 3d, in Bromine, Krypton), and (5p, 5s, 4d in Iodine, Xenon). The qualitative behaviors of the Wigner delays between the isoelectronic pairings were found to be similar in nature, with the only large differences occurring at photoelectron energies less than 20 eV and around Cooper minima. Interestingly, the relative shift in Wigner time delays between negatively charged halogens and noble gases decreases as atomic mass increases. All atomic pairings show large differences at low energies, with noble gas atoms showing large positive Wigner delays, while negatively charged halogen ions show negative delays. The implications for photoionization studies in halide-containing molecules is also discussed.

Grafstrom, Brock↗

Hunting for Planetary Nebulae toward the Galactic Center

We present near-infrared (IR) spectra of two planetary nebula (PN) candidates in close lines of sight toward the Galactic center (GC) using the Gemini Near-Infrared Spectrograph at Gemini North. High-resolution images from radio continuum and narrowband IR observations reveal ringlike or barrel-shaped morphologies of these objects, and their mid-IR spectra from the Spitzer Space Telescope exhibit rich emission lines from highly-excited species such as [S iv], [Ne iii], [Ne v], and [O iv]. We also derive elemental abundances using the Cloudy synthetic models, and find an excess amount of the s-process element krypton in both targets, which supports their nature as PNe. We estimate foreground extinction toward each object using near-IR hydrogen recombination lines, and find significant visual extinctions (A {sub V} > 20). The distances inferred from the size versus surface brightness relation of other PNe are 9.0 ± 1.6 kpc and 7.6 ± 1.6 kpc for SSTGC 580183 and SSTGC 588220, respectively. These observed properties along with the abundance patterns and close proximity to Sgr A* (projected distances ≲20 pc) make it highly probable that these objects are the first confirmed PN objects in the nuclear stellar disk. The apparent scarcity of such objects resembles the extremely low rate of PN formation in old stellar systems, but is in line with the current rate of sustained star formation activity in the Central Molecular Zone.

47 OTHER INSTRUMENTATION↗

NCSU Flux Tower Data

NCSU Flux Tower Data Level b1: QC checks applied to measurements Data Format: CSV Description: See "instrument descripotion Site: Houston, TX; Tracking Aerosol Convection interactions ExpeRiment (HOU) Location: Houston, TX; AMF1 (main site for TRACER) Facility Code: M1 Category: Aerosol Properties Data Type: PI Data Source Instrument/Data: Sonic Anemometer, 3 Condensation Particle Counters, 1 SP2, 1 POPS Start Date: 2022-06-01 End Date: 2022-9-26 Contact PI: Markus Petters (mdpetter@ncsu.edu) Funding Source: DOE ASR award US Department of Energy, Office of Science, Biological and Environment Research (grant no. DE-SC 0021074) Instrument description The NCSU flux tower was located next to the AMF sampling pad. The flux tower consisted of a 10 m telescoping tower. Mounted at the top of the tower was a sonic anemometer (RM Young 8000) and a Krypton Hygrometer. A sample line (¼” conductive tubing) and communication line was laid to a trailer located underneath and slightly adjacent to the tower. The sample line brought aerosol inside the trailer at 4.5 L min-1, where it was distributed between 3 CPCs (TSI 3776c, Dc ~ 2.5 nm, TSI 3771, Dc ~10nm, and TSI 3772, Dc ~40 nm) with different size cuts. Also sampling was a printed particle optical spectrometer (POPS) and a single particle soot photometer (SP2). Please contact mdpetter@ncsu.edu for further information.

54 ENVIRONMENTAL SCIENCES↗

Electrodeless discharge lamp is easily started, has high stability

Electrodeless discharge borosilicate glass lamp is used in various high-resolution optical systems. It is partially charged with krypton, contains small amounts of rubidium, and is enclosed in a hermetically sealed envelope that maintains the lamp at an optimum temperature during discharge. The lamp is quickly started by its excitation coil.

Bell, W. E.↗

Thermal laboratory report

Uniformity filtering, spectral filtering, and spectral matching using krypton and xenon lamps in solar simulation techniques development

SPECTRAL ANALYSIS↗

Microwave Driven Magnetic Plasma Accelerator Studies (CYCLOPS)

A microwave-driven cyclotron resonance plasma acceleration device was investigated using argon, krypton, xenon, and mercury as propellants. Limited ranges of propellant flow rate, input power, and magnetic field strength were used. Over-all efficiencies (including the 65% efficiency of the input polarizer) less than 10% were obtained for specific impulse values between 500 and 1500 sec. Power transfer efficiencies, however, approached 100% of the input power available in the right-hand component of the incident circularly polarized radiation. Beam diagnostics using Langmuir probes, cold gas mapping, r-f mapping and ion energy analyses were performed in conjunction with an engine operating in a pulsed mode. Measurements of transverse electron energies at the position of cyclotron resonant absorption yielded energy values more than an order of magnitude lower than anticipated. The measured electron energies were, however, consistent with the low values of average ion energy measured by retarding potential techniques. The low values of average ion energy were also consistent with the measured thrust values. It is hypothesized that ionization and radiation limit the electron kinetic energy to low-values thus limiting the energy which is finally transferred to the ion. Thermalization by electron-electron collision was also identified as an additional loss mechanism. The use of light alkali metals, which have relatively few low lying energy levels to excite, with the input power to mass ratio selected so as to limit the electron energies to less than the second ionization potential, is suggested. It is concluded, however, that the over-all efficiency for such propellants would be less than 40 per cent.

CYCLOPS PLASMA ACCELERATOR↗