Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implementation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Implementing next generation assessment: A case example of a global challenge

IA regime design has evolved significantly over the past 50 years. Current thinking includes a package of next generation approaches such as the incorporation of requirements for regional and strategic IA, the consideration of cumulative effects and alternatives, and the inclusion of sustainability criteria and trade-off rules for decision makers. These suggested changes to IA design largely come from the recognition, through experience, of the weaknesses with current IA laws and regulations and needs to accommodate new understandings, for example about sustainability and complexity. Here, we reiterate the key generic components of next generation assessment that are broadly suitable for application in all jurisdictions with at least moderate assessment capacities, focusing on the necessary process requirements that could be captured in IA law, regulation and policy. Through an illustrative case example of Manitoba, Canada, we show how the components of next generation assessment might be implemented as a package in the context of an existing IA regime. Our application of these principles reveals the value of careful consideration of the current legislative frame as well as needs to cooperate with other jurisdictions. It shows, for example, the importance of experience with using streams of assessment and ensuring meaningful public participation. We conclude that many jurisdictions are likely to find moving consistently to this more comprehensive form of assessment to be a natural progression and that the greatest challenges will probably be in building interjurisdictional cooperation, ensuring good faith application of the sustainability criteria in decision making, and implementing regional and strategic assessments.

54 ENVIRONMENTAL SCIENCES↗

Implementation and test of an automated control hunting fault correction algorithm in a fault detection and diagnostics tool

Control hunting due to improper proportional–integral–derivative (PID) parameters in the building automation system (BAS) is one of the most common faults identified in commercial buildings. It can cause suboptimal performance and early failure of heating, ventilation, and air conditioning (HVAC) equipment. Commercial fault detection and diagnostics (FDD) software represents one of the fastest growing market segments in smart building technologies in the United States. Implementation of PID retuning procedures as an auto-correction algorithm and integration into FDD software has the potential to mitigate control hunting across a heterogeneous portfolio of buildings with different BAS in a scalable way. This paper presents the development, implementation, and field testing of an automated control hunting fault correction algorithm based on lambda tuning open-loop rules. The algorithm was developed in a commercial FDD software and successfully tested among nine variable air volume boxes in an office building in the United States. The paper shows the feasibility of using FDD tools to automatically correct control hunting faults, discusses scalability considerations, and proposes a path forward for the HVAC industry and academia to further improve this technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toward more mechanistic representations of biogeochemical processes in river networks: Implementation and demonstration of a multiscale model

A recently introduced multiscale model for representing the effects of small-scale hyporheic-zone biogeochemical processes is extended from the reach scale to river network scales. The model uses advection-dispersion-reaction equations for the channel network and one-dimensional advection-reaction subgrid models for the hyporheic zone. We summarize implementation in the integrated surface/subsurface hydrology modeling system Amanzi-ATS. The extension uses topologically defined meshes to represent stream/river networks and associates a hyporheic subgrid model with each channel grid cell. Biogeochemical reaction modeling capability residing in community software is accessed through an application programming interface. The implementation is verified against independent numerical solutions on a single reach. Mesh convergence studies show that commonly used semi-distributed representations can introduce significant spatial discretization error. Denitrification of farm runoff in a subbasin of the Portage River Basin in Ohio, USA is used to demonstrate the general-purpose reactive transport capability.

54 ENVIRONMENTAL SCIENCES↗

QoS-aware edge AI placement and scheduling with multiple implementations in FaaS-based edge computing

Resource constraints on the computing continuum require that we make smart decisions for serving AI-based services at the network edge. AI-based services typically have multiple implementations (e.g., image classification implementations include SqueezeNet, DenseNet, and others) with varying trade-offs (e.g., latency and accuracy). The question then is how should AI-based services be placed across Function-as-a-Service (FaaS) based edge computing systems in order to maximize total Quality-of-Service (QoS). To address this question, we propose a problem that jointly aims to solve (i) edge AI service placement and (ii) request scheduling. These are done across two time-scales (one for placement and one for scheduling). Here we first cast the problem as an integer linear program. We then decompose the problem into separate placement and scheduling subproblems and prove that both are NP-hard. We then propose a novel placement algorithm that places services while considering device-to-device communication across edge clouds to offload requests to one another. Our results show that the proposed placement algorithm is able to outperform a state-of-the-art placement algorithm for AI-based services, and other baseline heuristics, with regard to maximizing total QoS. Additionally, we present a federated learning-based framework, FLIES, to predict the future incoming service requests and their QoS requirements. Our results also show that our FLIES algorithm is able to outperform a standard decentralized learning baseline for predicting incoming requests and show comparable predictive performance when compared to centralized training.

97 MATHEMATICS AND COMPUTING↗

{sup 32}P Brachytherapy Conformal Source Model RIC-100 for High-Dose-Rate Treatment of Superficial Disease: Monte Carlo Calculations, Diode Measurements, and Clinical Implementation

Purpose: A novel {sup 32}P brachytherapy source has been in use at our institution intraoperatively for temporary radiation therapy of the spinal dura and other localized tumors. We describe the dosimetry and clinical implementation of the source. Methods and Materials: Dosimetric evaluation for the source was done with a complete set of MCNP5 Monte Carlo calculations preceding clinical implementation. In addition, the depth dose curve and dose rate were measured by use of an electron field diode to verify the Monte Carlo calculations. Calibration procedures using the diode in a custom-designed phantom to provide an absolute dose calibration and to check dose uniformity across the source area for each source before treatment were established. Results: Good agreement was established between the Monte Carlo calculations and diode measurements. Quality assurance measurements results are provided for about 100 sources used to date. Clinical source calibrations were usually within 10% of manufacturer specifications. Procedures for safe handling of the source are described. Discussion: Clinical considerations for using the source are discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Simple and Efficient Methodology To Improve Geometric Accuracy in Gamma Knife Radiation Surgery: Implementation in Multiple Brain Metastases

Purpose: To propose, verify, and implement a simple and efficient methodology for the improvement of total geometric accuracy in multiple brain metastases gamma knife (GK) radiation surgery. Methods and Materials: The proposed methodology exploits the directional dependence of magnetic resonance imaging (MRI)-related spatial distortions stemming from background field inhomogeneities, also known as sequence-dependent distortions, with respect to the read-gradient polarity during MRI acquisition. First, an extra MRI pulse sequence is acquired with the same imaging parameters as those used for routine patient imaging, aside from a reversal in the read-gradient polarity. Then, “average” image data are compounded from data acquired from the 2 MRI sequences and are used for treatment planning purposes. The method was applied and verified in a polymer gel phantom irradiated with multiple shots in an extended region of the GK stereotactic space. Its clinical impact in dose delivery accuracy was assessed in 15 patients with a total of 96 relatively small (<2 cm) metastases treated with GK radiation surgery. Results: Phantom study results showed that use of average MR images eliminates the effect of sequence-dependent distortions, leading to a total spatial uncertainty of less than 0.3 mm, attributed mainly to gradient nonlinearities. In brain metastases patients, non-eliminated sequence-dependent distortions lead to target localization uncertainties of up to 1.3 mm (mean: 0.51 ± 0.37 mm) with respect to the corresponding target locations in the “average” MRI series. Due to these uncertainties, a considerable underdosage (5%-32% of the prescription dose) was found in 33% of the studied targets. Conclusions: The proposed methodology is simple and straightforward in its implementation. Regarding multiple brain metastases applications, the suggested approach may substantially improve total GK dose delivery accuracy in smaller, outlying targets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Implementation of a Model-Based In Vivo Dose Verification System for Stereotactic Body Radiation Therapy–Volumetric Modulated Arc Therapy Treatments Using the Electronic Portal Imaging Device

Purpose: To report findings from an in vivo dosimetry program implemented for all stereotactic body radiation therapy patients over a 31-month period and discuss the value and challenges of utilizing in vivo electronic portal imaging device (EPID) dosimetry clinically. Methods and Materials: From December 2013 to July 2016, 117 stereotactic body radiation therapy–volumetric modulated arc therapy patients (100 lung, 15 spine, and 2 liver) underwent 602 EPID-based in vivo dose verification events. A developed model-based dose reconstruction algorithm calculates the 3-dimensional dose distribution to the patient by back-projecting the primary fluence measured by the EPID during treatment. The EPID frame-averaging was optimized in June 2015. For each treatment, a 3%/3-mm γ comparison between our EPID-derived dose and the Eclipse AcurosXB–predicted dose to the planning target volume (PTV) and the ≥20% isodose volume were performed. Alert levels were defined as γ pass rates <85% (lung and liver) and <80% (spine). Investigations were carried out for all fractions exceeding the alert level and were classified as follows: EPID-related, algorithmic, patient setup, anatomic change, or unknown/unidentified errors. Results: The percentages of fractions exceeding the alert levels were 22.6% for lung before frame-average optimization and 8.0% for lung, 20.0% for spine, and 10.0% for liver after frame-average optimization. Overall, mean (± standard deviation) planning target volume γ pass rates were 90.7% ± 9.2%, 87.0% ± 9.3%, and 91.2% ± 3.4% for the lung, spine, and liver patients, respectively. Conclusions: Results from the clinical implementation of our model-based in vivo dose verification method using on-treatment EPID images is reported. The method is demonstrated to be valuable for routine clinical use for verifying delivered dose as well as for detecting errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Towards oscillation-free implementation of the immersed boundary method with spectral-like methods

Highlights: {yields} A radial basis function based smoothing technique is introduced. {yields} It is more general and easier to implement compared to other techniques. {yields} With this technique, a combined immersed boundary and spectral method is developed. {yields} It is shown that the proposed method works better in terms of reducing the non-physical Gibbs oscillation. - Abstract: It is known that, when the immersed boundary method (IBM) is implemented within spectral-like methods, the Gibbs oscillation seriously deteriorates the calculation of derivatives near the body surface. In this paper, a radial basis function (RBF) based smoothing technique is proposed with the intention of eliminating or efficiently reducing the Gibbs oscillation without affecting the flow field outside the body. Based on this technique, a combined IBM/spectral scheme is developed to solve the incompressible Navier-Stokes equations. Numerical simulations of flow through a periodic lattice of cylinders of various cross sections are performed. The results demonstrate that the proposed methodology is able to give accurate and nearly oscillation-free numerical solutions of incompressible viscous flows.

97 MATHEMATICS AND COMPUTING↗

Code-verification techniques for the method-of-moments implementation of the magnetic-field integral equation

For computational physics simulations, code verification plays a major role in establishing the credibility of the results by assessing the correctness of the implementation of the underlying numerical methods. In computational electromagnetics, surface integral equations, such as the method-of-moments implementation of the magnetic-field integral equation, are frequently used to solve Maxwell's equations on the surfaces of electromagnetic scatterers. These electromagnetic surface integral equations yield many code-verification challenges due to the various sources of numerical error and their possible interactions. In this paper, we provide approaches to separately measure the numerical errors arising from these different error sources. We demonstrate the effectiveness of these approaches for cases with and without coding errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Code-verification techniques for the method-of-moments implementation of the combined-field integral equation

Code verification plays an important role in establishing the credibility of computational simulations by assessing the correctness of the implementation of the underlying numerical methods. In computational electromagnetics, the numerical solution to integral equations incurs multiple interacting sources of numerical error, as well as other challenges, which render traditional code-verification approaches ineffective. In this paper, we provide approaches to separately measure the numerical errors arising from these different error sources for the method-of-moments implementation of the combined-field integral equation. Here, we demonstrate the effectiveness of these approaches for cases with and without coding errors.

97 MATHEMATICS AND COMPUTING↗

Implementation of a Mesh refinement algorithm into the quasi-static PIC code QuickPIC

Plasma-based acceleration (PBA) has emerged as a promising candidate for the accelerator technology used to build a future linear collider and/or an advanced light source. In PBA, a trailing or witness particle beam is accelerated in the plasma wave wakefield (WF) created by a laser or particle beam driver. The WF is often nonlinear and involves the crossing of plasma particle trajectories in real space and thus particle-in-cell methods are used. The distance over which the drive beam evolves is several orders of magnitude larger than the wake wavelength. This large disparity in length scales is amenable to the quasi-static approach. Three-dimensional (3D), quasi-static (QS), particle-in-cell (PIC) codes, e.g., QuickPIC, have been shown to provide high fidelity simulation capability with 2-4 orders of magnitude speedup over 3D fully explicit PIC codes. In PBA, the witness beam needs to be matched to the focusing forces of the WF to reduce the emittance growth. In some linear collider designs, the matched spot size of the witness beam can be 2 to 3 orders of magnitude smaller than the spot size (and wavelength) of the wakefield. Such an additional disparity in length scales is ideal for mesh refinement where the WF within the witness beam is described on a finer mesh than the rest of the WF. A mesh refinement scheme is described that has been implemented into the 3D QS PIC code, QuickPIC. Very fine (high) resolution is used in a small spatial region that includes the witness beam and progressively coarser resolutions in the rest of the simulation domain. A fast multigrid Poisson solver has been implemented for the field solve on the refined meshes and a Fast Fourier Transform (FFT) based Poisson solver is used for the coarse mesh. The code has been parallelized with both MPI and OpenMP, and the parallel scalability has also been improved by using pipelining. A preliminary adaptive mesh refinement technique is described to optimize the computational time for simulations with an evolving witness beam size. Several test problems are used to verify that the mesh refinement algorithm provides accurate results. Additionally, the results are benchmarked against highly resolved simulations exhibiting near-azimuthal symmetry, performed using QPAD—a novel hybrid QS PIC code that uses a PIC description in the coordinates (r, ct – z) and a gridless description in the azimuthal angle, Φ.

Linear collider↗

Implementation and evaluation of modified dynamic conformal arc (MDCA) technique for lung SBRT patients following RTOG protocols

To implement modified dynamic conformal arc (MDCA) technique and Radiation Therapy Oncology Group (RTOG) protocols in our clinic for stereotactic body radiation therapy (SBRT) treatment of patients with Stage I/II non–small cell lung cancer. Five patients with non–small cell lung cancer have been treated with SBRT. All the patients were immobilized using CIVCO Body Pro-Lok system and scanned using GE 4-slice computed tomography. The MDCA technique that was previously published was adopted as our planning technique, and RTOG protocols for the lung SBRT were followed. The patients were treated on Novalis Tx system with cone-beam computed tomography imaging guidance. All the patient plans passed the RTOG criteria. The conformal index ranges from 0.99 to 1.12 for the planning target volume, and the biological equivalent dose for the planning target volume is overall 100 Gy. Critical structures (lung, spinal cord, brachial plexus, skin, and chest wall) also meet RTOG protocols or published data. A 6-month follow-up of one of the patients shows good local disease control. We have successfully implemented the MDCA technique into our clinic for the lung SBRT program. It shows that the MDCA is useful and efficient for the lung SBRT planning, with the plan quality meeting the RTOG protocols.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical implementation of radiosurgery using the Helical TomoTherapy unit

The American Society of Radiation Oncology has recently recommended the use of radiosurgery to manage brain metastases. For such a recommendation to be implemented in a widespread manner, radiosurgery must be accessible at community radiation therapy facilities. The work presented here describes our clinical experience in the implementation of radiosurgery using a Helical TomoTherapy unit. Helical TomoTherapy is a unique dose-delivery system designed to perform intensity-modulated radiation therapy (IMRT). The system built on the ring-based gantry has the tight machine tolerances required for radiosurgery. A frameless system consisting of a thermoplastic mask and a noninvasive ''stereotactic radiosurgery (SRS)-stereotactic radiotherapy (SRT)'' fixation device is used for patient immobilization. Treatment planning is performed using the TomoHD treatment planning system designed for IMRT. The image-guidance system on the Helical TomoTherapy is used for patient localization. Our clinical experience demonstrated that the radiosurgery procedure can be streamlined as we do for IMRT patients. The treatment time of about 10 minutes is comparable with that for IMRT patients. The same patient-specific quality assurance for IMRT is used for radiosurgery. As demonstrated, SRS using Helical TomoTherapy is not a whole-day event, unlike SRS using other dose-delivery systems or SRS performed in the past.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Beam position monitor gate functionality implementation and applications

We introduce a novel technique to implement gate functionality for the beam position monitors (BPM) at the National Synchrotron Light Source II (NSLS-II). The functionality, now implemented in FPGA, allows us to acquire two separated bunch-trains’ synchronized turn-by-turn (TBT) data simultaneously with the NSLS-II in-house developed BPM system. The gated position resolution is improved about 3 times by narrowing the sampling width. Experimentally we demonstrated that the machine lattice could be transparently characterized with the gated TBT data of a short diagnostic bunch-train Cheng et al., 2017; Li et al., 2017. Other applications, for example, precisely characterizing storage ring impedance/wake-field through recording the beam positions of two separated bunch trains has been experimentally demonstrated.

43 PARTICLE ACCELERATORS↗

Implementing nonlinear optics from Off-Energy closed orbit at NSLS-II

To characterize the second-order (chromatic sextupole) magnet lattice with high precision, we implemented nonlinear optics from off-energy closed orbit (NOECO) tool based on the linear optics from closed orbit modulation (LOCOM) method, named LOCOM-NOECO. The preliminary numerical study indicates that 1–2% precision can be achieved for the calibration of chromatic sextupoles. Further, this accuracy could potentially help in resolving some long-standing challenges of NSLS-II (e.g., the discrepancy between the designed and measured dynamic apertures) if such high precision can be fulfilled. As an independent crosscheck, we also implemented NOECO based on the independent component analysis (ICA) method using turn-by-turn (TBT) BPM data, named ICA-NOECO. Both ICA-NOECO and LOCOM-NOECO have been successfully applied to identify the pre-dialed random errors of a chromatic sextupole family including five power supplies, and achieved the root mean square (RMS) residual error of 1% and peak error less than 2%. Moreover, to mitigate the chromatic sextupole error effect, we applied the correction and achieved significant improvements in the injection efficiency as well as the dynamic apertures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A computationally efficient moment-preserving Monte Carlo electron transport method with implementation in Geant4

This paper presents the theoretical development and numerical demonstration of a moment-preserving Monte Carlo electron transport method. Foremost, a full implementation of the moment-preserving (MP) method within the Geant4 particle simulation toolkit is demonstrated. Beyond implementation details, it is shown that the MP method is a viable alternative to the condensed history (CH) method for inclusion in current and future generation transport codes through demonstration of the key features of the method including: systematically controllable accuracy, computational efficiency, mathematical robustness, and versatility. A wide variety of results common to electron transport are presented illustrating the key features of the MP method. In particular, it is possible to achieve accuracy that is statistically indistinguishable from analog Monte Carlo, while remaining up to three orders of magnitude more efficient than analog Monte Carlo simulations. Lastly, it is shown that the MP method can be generalized to any applicable analog scattering DCS model by extending previous work on the MP method beyond analytical DCSs to the partial-wave (PW) elastic tabulated DCS data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Second-order wave excitation forces in WEC-Sim/MOST: Implementation, experimental validation, and code-to-code comparison

Accurate prediction of second-order hydrodynamic loads is essential for floating bodies, including floating offshore wind turbines, wave energy converters, and hybrid wind–wave platforms. These nonlinear effects, arising from both sum- and difference-frequency forcing, are critical for capturing key response characteristics but remain challenging to model efficiently. In this work, we extend the open-source Wave Energy Converter Simulator / MATLAB for Offshore Simulation Tool by implementing second-order wave excitation forces, supporting both the full Quadratic Transfer Function formulation and the Newman approximation. The full Quadratic Transfer Function method is used for all code-to-code comparisons and experimental validation, while the Newman approximation is provided as a computationally lighter alternative. To benchmark the new capability, we perform a code-to-code comparison with OpenFAST and OrcaFlex. We then validate the enhanced model using wave-tank measurements of a 1:96 scale DeepCwind semi-submersible, showing that second-order effects are required to reproduce platform motions. The implementation employs a computationally efficient pre-computation strategy for second-order wave excitation forces, reducing simulation cost while maintaining engineering accuracy. Overall, this work advances the tool as an open-source and versatile tool for modelling floating offshore renewable-energy systems requiring second-order hydrodynamic fidelity.

17 WIND ENERGY↗

The OpenACC data model: Preliminary study on its major challenges and implementations

This paper describes how the OpenACC data model is implemented in current OpenACC compilers, ranging from research compilers (OpenUH and OpenARC) to a commercial compiler (the PGI OpenACC compiler). First, we summarize various memory architectures in today’s accelerator systems. We then describe details and issues in implementing the OpenACC data model in three different OpenACC compilers. This includes managing page tables, asynchronous data transfers, asynchronous memory allocate and free, host data construct, aliasing on a data directive, reusing device memory, partially present data, and adjacent data. We also discusses ongoing work to manage large, complex dynamic data structures. We measured the present table lookups, device memory allocation, pinned memory allocation, and managed memory in the three OpenACC compilers using eight OpenACC applications (seven from the SPEC ACCEL benchmark suite and a shock-hydrodynamics mini-application called LULESH).

97 MATHEMATICS AND COMPUTING↗