Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Investigation of physical image characteristics and phenomenon of edge enhancement by phase contrast using equipment typical for mammography

A technique called phase contrast mammography (PCM) has only recently been applied in clinical examination. In this application, PCM images are acquired at a 1.75x magnification using an x-ray tube for clinical use, and then reduced to the real size of the object by image processing. The images showed enhanced object edges; reportedly, this enhancement occurred because of the refraction of x rays through a cylindrical object. The authors measured the physical image characteristics of PCM to compare the image characteristics of PCM with those of conventional mammography. More specifically, they measured the object-edge-response characteristics and the noise characteristics in the spatial frequency domain. The results revealed that the edge-response characteristics of PCM outperformed those of conventional mammography. In addition, the characteristics changed with the object-placement conditions and the object shapes. The noise characteristics of PCM were better than those of conventional mammography. Subsequently, to verify why object edges were enhanced in PCM images, the authors simulated image profiles that would be obtained if the x rays were refracted and totally reflected by using not only a cylindrical substance but also a planar substance as the object. So, they confirmed that the object edges in PCM images were enhanced because x rays were refracted irrespective of the object shapes. Further, they found that the edge enhancements depended on the object shapes and positions. It was also proposed that the larger magnification than 1.75 in the commercialized system might be more suitable for PCM. Finally, the authors investigated phase-contrast effects to breast tissues by the simulation and demonstrated that PCM would be helpful in the diagnoses of mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Hybrid vision activities at NASA Johnson Space Center

NASA's Johnson Space Center in Houston, Texas, is active in several aspects of hybrid image processing. (The term hybrid image processing refers to a system that combines digital and photonic processing). The major thrusts are autonomous space operations such as planetary landing, servicing, and rendezvous and docking. By processing images in non-Cartesian geometries to achieve shift invariance to canonical distortions, researchers use certain aspects of the human visual system for machine vision. That technology flow is bidirectional; researchers are investigating the possible utility of video-rate coordinate transformations for human low-vision patients. Man-in-the-loop teleoperations are also supported by the use of video-rate image-coordinate transformations, as researchers plan to use bandwidth compression tailored to the varying spatial acuity of the human operator. Technological elements being developed in the program include upgraded spatial light modulators, real-time coordinate transformations in video imagery, synthetic filters that robustly allow estimation of object pose parameters, convolutionally blurred filters that have continuously selectable invariance to such image changes as magnification and rotation, and optimization of optical correlation done with spatial light modulators that have limited range and couple both phase and amplitude in their response.

Juday, Richard D.↗

US automated rendezvous and capture capabilities review. Remote umbilical system abstract

This document will describe the technology developed at Kennedy Space Center (KSC) to demonstrate automatic tracking, docking, and mating of umbilical systems. Specifically the use of a real time six degree of freedom (6DOF) target tracking vision system, (developed by Adaptive Automation, Inc. under contract to KSC), is discussed in detail. The paper describes the use of mechanical compliance in the docking, mating, and tracking-after-mating operations. The vision system computes six coordinates that define the position and orientation of a three dimensional target using data from a single CCD camera. The camera is mounted on a 6DOF robot arm. After target coordinates are computed, they are transmitted to a supervisory computer which controls the robot motion in real time. Details of the image processing algorithms, image processing hardware, and target configuration used in the vision system are discussed in the paper. The motion of the space vehicle relative to the service structure after mating led us to the development of a compliant system that allows enough displacement of the target relative to the camera so that tracking after mating may continue. This reduces internal stresses between flight and ground hardware.

Delcastillo, Eduardo Lopez↗

Land image data processing requirements for the EOS era

Requirements are proposed for a hybrid approach to image analysis that combines the functionality of a general-purpose image processing system with the knowledge representation and manipulation capabilities associated with expert systems to improve the productivity of scientists in extracting information from remotely sensed image data. The overall functional objectives of the proposed system are to: (1) reduce the level of human interaction required on a scene-by-scene basis to perform repetitive image processing tasks; (2) allow the user to experiment with ad hoc rules and procedures for the extraction, description, and identification of the features of interest; and (3) facilitate the derivation, application, and dissemination of expert knowledge for target recognition whose scope of application is not necessarily limited to the image(s) from which it was derived.

Wharton, Stephen W.↗

Platform for Post-Processing Waveform-Based NDE

Signal- and image-processing methods are commonly needed to extract information from the waves, improve resolution of, and highlight defects in an image. Since some similarity exists for all waveform-based nondestructive evaluation (NDE) methods, it would seem that a common software platform containing multiple signal- and image-processing techniques to process the waveforms and images makes sense where multiple techniques, scientists, engineers, and organizations are involved. NDE Wave & Image Processor Version 2.0 software provides a single, integrated signal- and image-processing and analysis environment for total NDE data processing and analysis. It brings some of the most useful algorithms developed for NDE over the past 20 years into a commercial-grade product. The software can import signal/spectroscopic data, image data, and image series data. This software offers the user hundreds of basic and advanced signal- and image-processing capabilities including esoteric 1D and 2D wavelet-based de-noising, de-trending, and filtering. Batch processing is included for signal- and image-processing capability so that an optimized sequence of processing operations can be applied to entire folders of signals, spectra, and images. Additionally, an extensive interactive model-based curve-fitting facility has been included to allow fitting of spectroscopy data such as from Raman spectroscopy. An extensive joint-time frequency module is included for analysis of non-stationary or transient data such as that from acoustic emission, vibration, or earthquake data.

Roth, Don J.↗

Image Data Processing System (IDAPS) user manual, S-056 experiment. Volume 1: System description. Volume 2: Batch IDAPS. Volume 3: Interactive IDAPS

Image data processing system (IDAPS) developed to satisfy the image processing requirements of the Skylab S-056 experiment is described. The S-056 experiment was designed to obtain high-resolution photographs of the sun in the far ultraviolet, or soft X-ray, portion of the electromagnetic spectrum. Thirty-five thousand photographs were obtained by the three flights of the program; and, faced with such a massive volume of imagery, the designers of the experiment decided to develop a computer-based system which would reduce the image processing workload. The purpose of the IDAPS User Manual is to give the IDAPS user the necessary information and instructions to effectively utilize the system.

Source record↗

A review of breast tomosynthesis. Part I. The image acquisition process

Mammography is a very well-established imaging modality for the early detection and diagnosis of breast cancer. However, since the introduction of digital imaging to the realm of radiology, more advanced, and especially tomographic imaging methods have been made possible. One of these methods, breast tomosynthesis, has finally been introduced to the clinic for routine everyday use, with potential to in the future replace mammography for screening for breast cancer. In this two part paper, the extensive research performed during the development of breast tomosynthesis is reviewed, with a focus on the research addressing the medical physics aspects of this imaging modality. This first paper will review the research performed on the issues relevant to the image acquisition process, including system design, optimization of geometry and technique, x-ray scatter, and radiation dose. The companion to this paper will review all other aspects of breast tomosynthesis imaging, including the reconstruction process.

60 APPLIED LIFE SCIENCES↗

Image2000: A Free, Innovative, Java Based Imaging Package

The National Aeronautics and Space Administration (NASA) Goddard Space Flight Center's (GSFC) Scientific and Educational Endeavors (SEE) and the Center for Image Processing in Education (CIPE) use satellite image processing as part of their science lessons developed for students and educators. The image processing products that they use, as part of these lessons, no longer fulfill the needs of SEE and CIPE because these products are either dependent on a particular computing platform, hard to customize and extend, or do not have enough functionality. SEE and CIPE began looking for what they considered the "perfect" image processing tool that was platform independent, rich in functionality and could easily be extended and customized for their purposes. At the request of SEE, NASA's GSFC, code 588 the Advanced Architectures and Automation Branch developed a powerful new Java based image processing endeavors.

Pell, Nicholas↗

Processing infrared images of aircraft lapjoints

Techniques for processing IR images of aging aircraft lapjoint data are discussed. Attention is given to a technique for detecting disbonds in aircraft lapjoints which clearly delineates the disbonded region from the bonded regions. The technique is weak on unpainted aircraft skin surfaces, but can be overridden by using a self-adhering contact sheet. Neural network analysis on raw temperature data has been shown to be an effective tool for visualization of images. Numerical simulation results show the above processing technique to be an effective tool in delineating the disbonds.

Syed, Hazari↗

TU-F-CAMPUS-J-04: Evaluation of Metal Artifact Reduction Technique for the Radiation Therapy Planning

Purpose: To evaluate the feasibility of using a metal artifact reduction technique in depleting metal artifact and its application in improving dose calculation in External Radiation Therapy Planning. Methods: CIRS electron density phantom was scanned with and without steel drill bits placed in some plug holes. Meta artifact reduction software with Metal Deletion Technique (MDT) was used to remove metal artifacts for scanned image with metal. Hounsfield units of electron density plugs from artifact free reference image and MDT processed images were compared. To test the dose calculation improvement after the MDT processed images, clinically approved head and neck plan with manual dental artifact correction was tested. Patient images were exported and processed with MDT and plan was recalculated with new MDT image without manual correction. Dose profiles near the metal artifacts were compared. Results: The MDT used in this study effectively reduced the metal artifact caused by beam hardening and scatter. The windmill around the metal drill was greatly improved with smooth rounded view. Difference of the mean HU in each density plug between reference and MDT images were less than 10 HU in most of the plugs. Dose difference between original plan and MDT images were minimal. Conclusion: Most metal artifact reduction methods were developed for diagnostic improvement purpose. Hence Hounsfield unit accuracy was not rigorously tested before. In our test, MDT effectively eliminated metal artifacts with good HU reproduciblity. However, it can introduce new mild artifacts so the MDT images should be checked with original images.

60 APPLIED LIFE SCIENCES↗

Analyses of requirements for computer control and data processing experiment subsystems. Volume 1: ATM experiment S-056 image data processing system techniques development

The solar imaging X-ray telescope experiment (designated the S-056 experiment) is described. It will photograph the sun in the far ultraviolet or soft X-ray region. Because of the imaging characteristics of this telescope and the necessity of using special techniques for capturing images on film at these wave lengths, methods were developed for computer processing of the photographs. The problems of image restoration were addressed to develop and test digital computer techniques for applying a deconvolution process to restore overall S-056 image quality. Additional techniques for reducing or eliminating the effects of noise and nonlinearity in S-056 photographs were developed.

Source record↗

Software for Acquiring Image Data for PIV

PIV Acquisition (PIVACQ) is a computer program for acquisition of data for particle-image velocimetry (PIV). In the PIV system for which PIVACQ was developed, small particles entrained in a flow are illuminated with a sheet of light from a pulsed laser. The illuminated region is monitored by a charge-coupled-device camera that operates in conjunction with a data-acquisition system that includes a frame grabber and a counter-timer board, both installed in a single computer. The camera operates in "frame-straddle" mode where a pair of images can be obtained closely spaced in time (on the order of microseconds). The frame grabber acquires image data from the camera and stores the data in the computer memory. The counter/timer board triggers the camera and synchronizes the pulsing of the laser with acquisition of data from the camera. PIVPROC coordinates all of these functions and provides a graphical user interface, through which the user can control the PIV data-acquisition system. PIVACQ enables the user to acquire a sequence of single-exposure images, display the images, process the images, and then save the images to the computer hard drive. PIVACQ works in conjunction with the PIVPROC program which processes the images of particles into the velocity field in the illuminated plane.

Wernet, Mark P.↗

Platform for Postprocessing Waveform-Based NDE

Taking advantage of the similarities that exist among all waveform-based non-destructive evaluation (NDE) methods, a common software platform has been developed containing multiple- signal and image-processing techniques for waveforms and images. The NASA NDE Signal and Image Processing software has been developed using the latest versions of LabVIEW, and its associated Advanced Signal Processing and Vision Toolkits. The software is useable on a PC with Windows XP and Windows Vista. The software has been designed with a commercial grade interface in which two main windows, Waveform Window and Image Window, are displayed if the user chooses a waveform file to display. Within these two main windows, most actions are chosen through logically conceived run-time menus. The Waveform Window has plots for both the raw time-domain waves and their frequency- domain transformations (fast Fourier transform and power spectral density). The Image Window shows the C-scan image formed from information of the time-domain waveform (such as peak amplitude) or its frequency-domain transformation at each scan location. The user also has the ability to open an image, or series of images, or a simple set of X-Y paired data set in text format. Each of the Waveform and Image Windows contains menus from which to perform many user actions. An option exists to use raw waves obtained directly from scan, or waves after deconvolution if system wave response is provided. Two types of deconvolution, time-based subtraction or inverse-filter, can be performed to arrive at a deconvolved wave set. Additionally, the menu on the Waveform Window allows preprocessing of waveforms prior to image formation, scaling and display of waveforms, formation of different types of images (including non-standard types such as velocity), gating of portions of waves prior to image formation, and several other miscellaneous and specialized operations. The menu available on the Image Window allows many further image processing and analysis operations, some of which are found in commercially-available image-processing software programs (such as Adobe Photoshop), and some that are not (removing outliers, Bscan information, region-of-interest analysis, line profiles, and precision feature measurements).

Roth, Don↗

Autonomous real-time detection of plumes and jets from moons and comets

Dynamic activity on the surface of distant moons, asteroids, and comets can manifest as jets or plumes. These phenomena provide information about the interior of the bodies and the forces (gravitation, radiation, thermal) they experience. Fast detection and follow-up study is imperative since the phenomena may be time-varying and because the observing window may be limited (e.g., during a flyby). We have developed an advanced method for real-time detection of plumes and jets using onboard analysis of the data as it is collected. In contrast to prior work, our technique is not restricted to plume detection from spherical bodies, making it relevant for irregularly shaped bodies such as comets. Further, our study analyzes raw data, the form in which it is available on board the spacecraft, rather than fully processed image products. In summary, we contribute a vital assessment of a technique that can be used on board tomorrow's deep space missions to detect, and respond quickly to, new occurrences of plumes and jets.

79 ASTRONOMY AND ASTROPHYSICS↗

TEMPORAL EVOLUTION AND SPATIAL DISTRIBUTION OF WHITE-LIGHT FLARE KERNELS IN A SOLAR FLARE

On 2011 September 6, we observed an X2.1-class flare in continuum and H α with a frame rate of about 30 Hz. After processing images of the event by using a speckle-masking image reconstruction, we identified white-light (WL) flare ribbons on opposite sides of the magnetic neutral line. We derive the light curve decay times of the WL flare kernels at each resolution element by assuming that the kernels consist of one or two components that decay exponentially, starting from the peak time. As a result, 42% of the pixels have two decay-time components with average decay times of 15.6 and 587 s, whereas the average decay time is 254 s for WL kernels with only one decay-time component. The peak intensities of the shorter decay-time component exhibit good spatial correlation with the WL intensity, whereas the peak intensities of the long decay-time components tend to be larger in the early phase of the flare at the inner part of the flare ribbons, close to the magnetic neutral line. The average intensity of the longer decay-time components is 1.78 times higher than that of the shorter decay-time components. If the shorter decay time is determined by either the chromospheric cooling time or the nonthermal ionization timescale and the longer decay time is attributed to the coronal cooling time, this result suggests that WL sources from both regions appear in 42% of the WL kernels and that WL emission of the coronal origin is sometimes stronger than that of chromospheric origin.

79 ASTRONOMY AND ASTROPHYSICS↗

New Martian satellite search

The approach pictures taken by the Viking 1 and Viking 2 spacecrafts two days before their Mars orbital insertion maneuvers were analyzed in order to search for new satellites within the orbit of Phobos. To accomplish this task, search procedure and analysis strategy were formulated, developed and executed using the substantial image processing capabilities of the Image Processing Laboratory at the Jet Propulsion Laboratory. The development of these new search capabilities should prove to be valuable to NASA in processing of image data obtained from other spacecraft missions. The result of applying the search procedures to the Viking approach pictures was as follows: no new satellites of comparable size (approx. 20 km) and brightness to Phobos or Demios were detected within the orbit of Phobos.

Source record↗

Thematic Mapper geometric correction processing

The Thematic Mapper Image Processing System is described from the point of view of geometric correction. The system performance requirements are discussed, and the Landsat-D flight segment is described. The ground processing and overall geometric system performance is addressed. Those aspects of the Thematic Mapper Image Processing System that differ significantly from those of the MSS System are emphasized.

Beyer, E. P.↗

Development of a Semi-autonomous Miniature Rover for Inspection of Double Shell Tank Floors - 19575

Leaks in the primary liner of double-shell tank (DST) 241-AY-102 at Hanford have prompted the need for the development of inspection tools that are able to access confined spaces around and underneath the tanks. Last year, Florida International University (FIU) has continued to improve inspection tools that were developed in the previous years, to ensure that the resultant tools are able to overcome the challenges posed by the DSTs. Experimental testing conducted last year at the full-scale sectional mock-up of the DST's refractory slots revealed some shortcomings of the miniature rover, particularly in traversing over weld seams of different heights. The weld seams are the results of welded steel plate-joints for the DST. It was advised by the site engineers that the weld seams height could range from 6.35 mm - 9.525 mm (1/4 to 3/8 inches), and with 12.7 mm (1/2 inches) width. As the rover traverses over a weld seam, the gap between the rover's magnets and tank surface increases, causing the adhesive force to drop. The rover loses its surface contact if this adhesive force drops below its weight, jeopardizing the inspection tasks. In this paper, we present the numerical studies to calculate the minimum magnetic force required for the miniature rover to traverse over weld seams with different heights and the corresponding modifications to the rover design. Initial bench scale tests were conducted using a steel bar with 5 welds of varying heights. The testing validated the results from the simulation studies and established the rover's capability in traversing weld seams. Another challenge for the miniature rover is the use of a joystick or keypad for manual control. Utilizing these controls will likely be difficult for the operators due to the tight channels underneath the tank. Having a semi-autonomous navigational capability would alleviate the complexity of the inspection tasks and allow the operator to focus on the channel inspection. The goal is to implement lane-keeping capability, akin to that of a driverless car, for the inspection tool, so that it will maintain its relative position with respect to the wall of the channels. Am image processing pipeline has been developed using both the Robot Operating System (ROS) and OpenCV to process the image stream coming from the onboard camera, for the purpose of lane identification. Additionally, a PID controller has been implemented to navigate the miniature rover along the central location of the detected lane, while allowing the operator to control the tool's forward and backward motion. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗