Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

A simple approach for characterizing the spatially varying sensitivity of microchannel plate detectors

Herein we present a simple approach to characterize the spatial variation of the gain in microchannel plate (MCP) coupled to phosphor detectors using single electron or photon hits. The technique is easy to implement and general enough to be extended to other kinds of detectors. We demonstrate the efficacy of the approach on both laboratory and Monte Carlo generated datasets. Furthermore, we use the approach to measure the variation in gain over time as the MCP is exposed to an increasing number of electrons.

47 OTHER INSTRUMENTATION↗

Electronographic photometry of extended objects. I - Reduction procedures

Attention is given to the reduction of electronographic camera images obtained with the aid of the Kron camera. A description is given of the equipment used to digitize the plate material. The response of the camera-emulsion-microdensitometer system is discussed along with present system performance figures. An outline is presented of existing and future computer reduction techniques.

Benedict, G.↗

Monocular electro-optical stereo scanner

MEOSS is a single optics and single spectral band camera. Three CCD's working in pushbroom mode are mounted perpendicular to the flight direction on a common focal plate. Their oblique views of + and - 23 degrees forward and backward, as well as nadir oriented, lead to threefold stereoscopic images. This principle allows a nearly simultaneous generation of all three images of a stereo triplet. The time gap between the forward and aft looking images guarantees constant illumination conditions. The ground resolution of MEOSS will be 52 by 80 m ground pixel size, height resolution of 55 m and swath width of 255 km. The drifting ground coverage pattern of MEOSS is unique compared to polar orbiting satellites and will allow images of an area to be taken at different times of the day. A scene will consist of 3144 scan lines, with each having 3236 pixels. The data will be received by the Deep Space Network of JPL Goldstone and mailed to Goddard.

Vermillion, C.↗

ORFEUS-SPAS - The Berkeley EUV spectrometer

The Berkeley EUV spectrometer of ORFEUS-SPAS, a joint project of NASA and the BMFT, incorporates a set of four novel spherically figured, varied line-space gratings used in a geometry that is similar to that of the classic Rowland mount to span an interval of 390 and 1200 A. Two spectral detector units containing curved microchannel plates and delay-line anodes encode the arriving photons in digital format for telemetry. An additional optic directs the image of the source in the entrance aperture onto a sealed FUV detector which is used to track the source as it drifts during an observation, enabling a postflight reconstruction of the spacecraft pointing vector. This in turn makes it possible to define with precision the wavelength of each recorded photon.

Bowyer, Stuart↗

Reflective Focused Schlieren System Improved for Use in 10- by 10-Foot Supersonic Wind Tunnel

The reflective focused schlieren system that was developed for use in the 10- by 10-Foot Supersonic Wind Tunnel (10x10 SWT) at the NASA Glenn Research Center at Lewis Field as part of the Unstart Test Program was improved this past year. In April 1999, the development and use of the system was presented at the Supersonic Tunnel Association International in Bedford, England. A focused schlieren system is similar to a standard schlieren system in that shock waves coming from an object in supersonic flow can be seen using a standard video camera. Unlike the standard schlieren system, which produces a two-dimensional schlieren image, a focused schlieren system can produce a threedimensional image. The preceding drawing shows the components of the reflective focused schlieren system being developed for use in the 10x10 SWT. Although the system worked well for the Unstart Test Program, it was not sensitive enough to be classified as a facility capability. Therefore, a program was implemented to improve the sensitivity of the reflective focused schlieren system so that it could be a facility capability for Glenn's 10x10 SWT. Several techniques were implemented to increase the sensitivity and to improve the overall operation of the system. These included refinement of the source grid, improvement in the cutoff grid production, improvement of the source grid and cutoff grid alignment, installation of an improved light source, and incorporation of an image-enhancing system. These changes are being implemented with the system set up in the laboratory. A checkout test of the system is planned in the 10x10 SWT in March 2000. Of these techniques, the most developed is the refinement of the source grid. The original system had a pattern of -in. by -in. squares on -in. centers (distance between the center points of adjacent squares). This gave a ratio of light to dark (reflective to nonreflective area) of 3:1. The recommended ratio is 1:1. In order to accomplish this, a pattern of -in.-diameter dots on 3/8-in. centers was developed. Preliminary tests with this pattern showed an increase in system sensitivity and image clarity. Further testing and refinement are scheduled. The former and improved dot patterns are shown. The use of glass plates to produce the cutoff grid improved the cutoff grid's quality and helped to align it with the source grid. The cutoff grid, which is the negative of the source grid, is made by exposing photography film (or glass plates) to the proper light while it is installed in the focused schlieren system. The exposed film or plate is removed from the system and then developed as a photograph negative. Because the glass plates are rigid, they eliminate the risk of distortion when the negative is reinstalled in the system and realigned with the source grid.

Williamson, Gary Scott↗

Phase and Pupil Amplitude Recovery for JWST Space-Optics Control

This slide presentation reviews the phase and pupil amplitude recovery for the James Webb Space Telescope (JWST) Near Infrared Camera (NIRCam). It includes views of the Integrated Science Instrument Module (ISIM), the NIRCam, examples of Phase Retrieval Data, Ghost Irradiance, Pupil Amplitude Estimation, Amplitude Retrieval, Initial Plate Scale Estimation using the Modulation Transfer Function (MTF), Pupil Amplitude Estimation vs lambda, Pupil Amplitude Estimation vs. number of Images, Pupil Amplitude Estimation vs Rotation (clocking), and Typical Phase Retrieval Results Also included is information about the phase retrieval approach, Non-Linear Optimization (NLO) Optimized Diversity Functions, and Least Square Error vs. Starting Pupil Amplitude.

Dean, B. H.↗

KWIC: A Widefield Mid-Infrared Array Camera/Spectrometer for the KAO

The Kuiper Widefield Infrared Camera (KWIC) is an imaging spectrometer designed for use on the Kuiper Airborne Observator between 18 and 40 microns. The spectral resolution achieving devices are two fully tunable and scanning cryogenic Fabry-Perot interferometers that employ free standing metal mesh as the reflective surfaces. The detective device is a 128 x 128 pixel Si:Sb BIB array manufactured by Rockwell/Boeing for the SIRTF project. The plate scale for KWIC (one pixel subtends 2.73" x 2.73") was chosen so as to more than fully sample the KAO beam (approximately 9" at 31.5 microns), to enable effective image restoration techniques to be applied. Even so, KWIC has a rather large (5.8' x 5.8') field of view. KWIC has both high and low spectral resolution modes that are interchangeable in a few minutes time in flight on the KAO. The high resolution (R = lambda/(delta)lambda = 1000 to 6000) mode is suitable for detecting weak lines in the presence of strong continuum for Galactic sources, and for resolving broad extragalactic lines. The low resolution (R approximately 30 to 100) mode is suitable for imaging in the thermal dust continuum.

Stacey, Gordon J.↗

Evaluation of Spray and Combustion Models for Simulating Dilute Combustion in a Direct-Injection Spark-Ignition Engine

Dilute combustion in spark-ignition engines has the potential to improve thermal efficiency by mitigating knock and by reducing throttling and wall heat losses. However, ignition and combustion processes can become unstable for dilute operation due to a lowered laminar flame speed, resulting in excessive cycle-to-cycle variability (CCV) of the combustion process. To compensate for the slower combustion in less reactive mixtures, a modified intake port geometry can be employed to generate a strong tumble flow in the cylinder and elevate turbulence levels around the spark plug, thereby promoting a faster transition to turbulent deflagration. Consequently, optimizing combustion chamber geometry and operating strategy is crucial to maximizing the benefits of using dilute combustion with enhanced in-cylinder turbulence across a wide range of operating conditions. Computational fluid dynamics (CFD) simulations can be utilized for virtual engine optimization tasks, but this would require the models to be truly predictive regarding the impact of changes to the engine design and operational parameters.In this study, multicycle large-eddy simulations (LES) are performed for a direct-injection spark-ignition engine to investigate the model performance in predicting engine combustion characteristics with respect to changes in the intake configuration. A tumble plate that blocks the lower part of the intake port inlet is used to vary the tumble. A set of CFD models that have been recently developed are employed, which takes into account the drag of nonspherical droplets, flash-boiling behavior of liquid sprays, spray-wall interaction, surrogate formulation of a research-grade E10 gasoline, and fast chemical kinetic solvers. Simulation results are compared to experimental engine data in terms of cylinder pressure, apparent heat release rate, mass fraction burned timing, and flame images. It is found that LES employing the state-of-the-art CFD models are capable of properly predicting the spray processes and reproducing the measured mean cylinder pressure for the case with the tumble plate. On the other hand, the LES over-predicts the combustion rate during the early combustion stage and under-estimates the CCV, and these discrepancies become larger when the tumble plate is removed.

computational fluid dynamics simulation↗

Dynamic Strength and Equation of State of Epon 828 and Diethanolamine (DEA) Polymer Epoxy Under Shock Loading

Polymers are increasingly utilized in engineering applications that can experience high loading rates, necessitating increased understanding of their response under such conditions. The tamped Richtmyer-Meshkov Instability (RMI) method was used to characterize the equation of state and dynamic strength of the polymer Epon 828 cured with Diethanolamine (DEA). Plate impact experiments that drove a uniaxial shock compression wave across a sinusoidally corrugated metal-polymer interface were performed to generate shock stresses from 4-12 GPa and strain rates of approximately 1/s in the polymer. X-ray phase contrast imaging recorded the shock motion in the polymer and subsequent interface evolution. Analysis of this data yielded the polymer equation of state and, in conjunction with numerical modeling, the dynamic strength. The equation of state was validated against one-dimensional plate impact experiments from existing literature. The dynamic strength was compared to prior data for Epon 828 and related polymers at lower strain rates and found to exhibit significant strain rate and pressure-hardening effects. The strength of the Epon 828 polymer at 10 6 1/s was found to be approximately 1.5 GPa, suggesting that it is comparable to the strength of high strength metals at these dynamic conditions.

Equation of state↗

Pulsed Thermal Tomography Nondestructive Examination of Additively Manufactured Reactor Materials (Second Annual Progress Report)

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of nuclear reactor parts. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which can introduce internal material flaws, such as pores and anisotropy. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures due to exposure to high temperature, radiation and corrosive environment in a nuclear reactor. Thermal tomography (TT) provides a capability for non-destructive evaluation of sub-surface defects in arbitrary size structures. Thermal tomography is a computational method for heat diffusion-based imaging of solids, which provides 3D visualization of data from flash thermography measurements. We investigate thermal tomography imaging and nondestructive evaluation of stainless steel and nickel super alloy metallic structures produced with laser powder bed fusion (LPBF) additive manufacturing (AM) process. Metallic structures produced with LPBF contain defects, and there are limited capabilities to evaluate these structures non-destructively. Thermal tomography reconstruction of 3D apparent spatial effusivity provides information about AM structure geometry and internal material flaws. We study performance of thermal tomography in imaging of metallic structures through COMSOL computer simulations of transient heat transfer, and through reconstruction of data obtained from experimental measurements. Reconstruction of internal defects is investigated using a stainless steel 316L specimen with flat bottom hole (FBH) indentations, and Inconel 718 plate produced with laser powder bed fusion (LPBF) method, which contains imprinted hemispherical shape low density regions containing non-sintered metallic powder. The FBH’s have the same sizes as the imprinted defects in the LPBF specimens, but offer better imaging contrast. Thermal tomography reconstructions provide visualizations of internal defects, and allow for estimation of their sizes and locations. Detection sensitivity of TT is limited by noises. We investigate separation of signal from noise in thermography images using several machine learning (ML) methods, including new spatio-temporal blind source separation (STBSS) and spatio-temporal sparse dictionary learning (STSDL) methods. Performance of the ML methods is benchmarked using thermography data obtained from imaging stainless steel 316L and Inconel 718 specimens produced LPBF method with imprinted calibrated porosity defects. The ML methods are ranked by F-score and execution runtime. Finally, we investigate TT of AM stainless steel 316L specimen with imprinted internal porosity defects using relatively low-cost, small form factor infrared (IR) camera based on uncooled micro bolometer detector. Sparse coding related K-means singular value decomposition (SVD) machine learning, image processing algorithms are developed to improve quality of TT images through removal of Additive white Gaussian noise without blurring the images. Following initial qualification of an AM component for deployment in a nuclear reactor, a compact TT can also be used for in-service nondestructive evaluation (NDE). With capability to perform in-service NDE of the AM component lifecycle, TT data can be used for development of a component digital twin.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Introduction to the special topic on inertial confinement fusion diagnostics

In the first decade of the 21st century, the United States began operating three leading Inertial Confinement Fusion (ICF) and High-Energy Density Physics (HEDP) facilities. The National Ignition Facility (NIF) began its quest to first surpass the Lawson Criterion and then reach thermonuclear ignition and thermonuclear gain. The Omega EP (Extended Performance) laser provides unprecedented energy, reliability, and consistency for petawatt (PW)-class laser experiments. The Omega laser continues to support over 1000 ICF and HEDP experiments each year. The Z pulsed power machine is a Z-pinch plasma confinement device that was refurbished to increase current drive and improve reliability. The extreme states of matter created in these new facilities required advancement of many technologies. The most important among these was the significant improvement in instrumentation capabilities needed to diagnose plasma conditions and resulting nuclear products. The instruments needed a better temporal, spatial, and energy resolution. They also needed to be hardened against EMP and radiation. Typical events in an ICF implosion include compressing the deuterium–tritium (DT) fuel to greater than 60 g/cm 3 and heating the DT to a temperature greater than 10 keV (110 000 000 K). The DT atoms react to produce 14 MeV neutrons from a volume with a radius of ~30 μm. When the fuel ignites, the DT burn prop agates into cold fuel and the neutron-emitting region can reach sizes of over 200 μm. Furthermore, the burn typically lasts less than 150 ps, but the burn duration will decrease as the DT yield increases. Burn durations as short as 90 ps have been recorded and are predicted to decrease still further to 20 ps. X-ray imaging diagnostics are needed to measure the acceleration and velocity of the capsule enclosing the DT, where the implosion velocities can reach over 400 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Microtomography Measurements of Coevolving Particle Size and Shape

This study measures simultaneous changes in particle size and shape during grain crushing and proposes quantitative metrics to track their coevolving statistical distribution. Idealized granular materials with widely different initial particle shapes (i.e., spheres, quasi-ellipsoids, plates, and rods) are compressed oedometrically at vertical stress levels sufficient to induce particle breakage. X-ray microtomography and digital image analysis are then used to track changes in particle-scale characteristics. The observations indicate that more irregular particles tend to exhibit a higher degree of breakage compared to more spherical grains subjected to an equivalent stress level. Despite these differences, the measurements also indicate that all the tested particle sets approach a common attractor (expressed in terms of aspect ratio, flatness, and elongation), regardless of their initial morphology. A new shape evolution index is proposed to quantify such trends. With this new metric, it is shown that in all the tested materials, the particle shape evolves faster than size, especially for the more regular morphologies, thus implying that the shape tends to reach its attractor point before the grading reaches its ultimate particle size distribution. Furthermore, this finding underpins an ultimate stage of crushing-driven compression that occurs with particle size reduction but minimal shape changes (i.e., self-replicating shapes due to fractures).

Oedometric compression↗

Image plane detector for the dynamics explorer Fabry-Perot interferometer

A compact twelve-channel photon-counting device based on existing Generation II imaging technology has been developed for use as the image-plane detector of the Dynamics Explorer Fabry-Perot interferometer. The device has an S-20 photocathode, three-microchannel plate electron multiplication stages, and an equal-area concentric-ring segmented anode whose geometry mimics that of the interference ring pattern produced by a plane etalon. The twelve channels sample equal and contiguous intervals in the spectrum. The purpose of the delopment has been to utilize the signal multiplex advantage of a multichannel detector in the measurement of Doppler shifts and line-broadening effects for naturally occurring atmospheric emission features of low intensity. The design, testing, calibration, and flight performance of the novel detector system are presented. In addition, measured emission line profiles at high resolution from the satellite instrument are presented to illustrate the operation of the device.

Killeen, T. L.↗

Coma morphology and dust-emission pattern of periodic comet Halley. III - Additional high-resolution images taken in 1910

High-resolution photographic images of comet Halley obtained at Lick, Helwan, Lowell, and Vienna observatories during May-June 1910 are analyzed using the image-processing algorithm of Larson and Sekanina (1984). The results are presented in tables and compared with analyses of Mt. Wilson plates for the same period (Sekanina and Larson, 1984), and good general agreement is noted. Consideration is given to the position of the rotation pole, features indicative of the nucleus spin rate, the spokelike structure observed on May 21-22, and the expanding gas halo.

Larson, S. M.↗

Quantitative analysis of hard X-ray 'footpoint' flares observed by the solar maximum mission

Amplifier gain and collimator hole size variations across the field of view, amplifier/filter efficiency, variations in effective collimator hole size and angular response with photon energy, dead-time, and hard X-ray plate transmission, are among the factors for which instrumental corrections have to be incorporated to effect reliable correction and deconvolution of images from the SMM satellite's Hard X-ray Imaging Spectrometer (HXIS). Attention is given to the substantial Poisson noise in these energy bands. The maximum entropy deconvolution/correction routine developed for establishing the spatial structure reliably inferrable from HXIS data is presented, together with the results of the application of this routine to the three impulsive flares reported by Duijemian et al. (1982) from April 10, May 21, and November 5, 1980.

Mackinnon, A. L.↗

Damage assessment and residual compression strength of thick composite plates with through-the-thickness reinforcements

Damage in composite materials was studied with through-the-thickness reinforcements. As a first step it was necessary to develop new ultrasonic imaging technology to better assess internal damage of the composite. A useful ultrasonic imaging technique was successfully developed to assess the internal damage of composite panels. The ultrasonic technique accurately determines the size of the internal damage. It was found that the ultrasonic imaging technique was better able to assess the damage in a composite panel with through-the-thickness reinforcements than by destructively sectioning the specimen and visual inspection under a microscope. Five composite compression-after-impact panels were tested. The compression-after-impact strength of the panels with the through-the-thickness reinforcements was almost twice that of the comparable panel without through-the-thickness reinforcement.

Smith, Barry T.↗

Damage assessment and residual compression strength of thick composite plates with through-the-thickness reinforcements

Damage in composite materials was studied with through-the-thickness reinforcements. As a first step it was necessary to develop new ultrasonic imaging technology to better assess internal damage of the composite. A useful ultrasonic imaging technique was successfully developed to assess the internal damage of composite panels. The ultrasonic technique accurately determines the size of the internal damage. It was found that the ultrasonic imaging technique was better able to assess the damage in composite panel with through-the-thickness reinforcements than by destructively sectioning the specimen and visual inspection under a microscope. Five composite compression-after-impact panels were tested. The compression-after-impact strength of the panels with the through-the-thickness reinforcements was almost twice that of the comparable panel without through-the-thickness reinforcement.

Smith, Barry T.↗

Hybrid pulse-burst / cross-correlation DGV for high-speed flow measurements at 100 kHz

Hybrid pulse-burst Doppler global velocimetry (PB-DGV)/pulse-burst, cross-correlation DGV (PB-CC-DGV) was demonstrated for the first time in the NASA Langley 4-foot Supersonic Unitary Plan Wind Tunnel, allowing simultaneous acquisition of mean and instantaneous high-repetition-rate velocity fields. The technique was used to make planar velocity measurements across an oblique shockwave generated by a large splitter plate set at a -2° angle of attack in a Mach 2.4 flow. Sequences of more than 100 consecutive instantaneous velocity images were obtained at a rate of 100 kHz. Velocity fields from both aspects of the hybrid measurement indicated errors less than 1-percent of anticipated velocities. Likewise, all assessments of measurement precision were approximately 1.6-percent of the local velocities. Additional demonstrations in different flowfields including a subsonic axi-symmetric jet and a supersonic Mars reentry vehicle model further illustrate the utility of the new hybrid method.

laser↗