Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Isotope dependence of transport in ST40 hot ion mode plasmas

The ST40 compact, high-field spherical tokamak, operating at 2.1 T and with 1.8 MW of neutral beam heating, achieved central carbon impurity ion temperatures in excess of 10 keV, surpassing their business milestone of 100 M °C (8.6 keV). The high temperature discharges were in the hot ion mode, with $T_i \gg T_e$, and they were achieved in both hydrogen and deuterium plasmas with deuterium neutral beam injection. In order to achieve the high temperature scenarios, careful wall conditioning and scenario optimization was carried out in $H^0 \rightarrow H^+$, $D^0 \rightarrow H^+$, and finally in $D^0 \rightarrow D^+$ plasmas. The TRANSP transport code was employed to study the dependence of confinement and transport on isotopic mass, and the conditions that led to the high measured central ion temperatures in the $D^0 \rightarrow H^+$ and $D^0 \rightarrow D^+$ plasmas. The kinetic profiles input into TRANSP were inferred from line-of-sight and limited radial measurements as well as consistency with a number of other experimental constraints. The TRANSP results first showed that the main species central ion temperature was only 0.5–1 keV lower than the measured carbon impurity temperature, and thus in the high performance plasmas also surpassed the 100 M °C level. TRANSP also showed that while the electron thermal conduction loss was dominant, reductions in central ion transport, and an effective decoupling of the ions from the electrons, led to an increase in central ion temperatures with increasing plasma mass. In fact, the associated confinement times exhibited a strong dependence on the isotopic mass of the thermal plasma. These preliminary results are foundations for dedicated experiments with full kinetic profile measurements on ST40 in the next run campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reducing turbulent transport in toroidal configurations via shaping

Recent progress in reducing turbulent transport in stellarators and tokamaks by 3D shaping using a stellarator optimization code in conjunction with a gyrokinetic code is presented. The original applications of the method focused on ion temperature gradient transport in a quasi-axisymmetric stellarator design. Here, an examination both of other turbulence channels and other starting configurations is initiated. It is found that the designs evolved for transport from ion temperature gradient turbulence also display reduced transport from other transport channels whose modes are also stabilized by improved curvature, such as electron temperature gradient and ballooning modes. The optimizer is also applied to evolving from a tokamak, finding appreciable turbulence reduction for these devices as well. From these studies, improved understanding is obtained of why the deformations found by the optimizer are beneficial, and these deformations are related to earlier theoretical work in both stellarators and tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hot ion plasma production in HIP-1 using water-cooled hollow cathodes

A steady-state ExB plasma was formed by applying a strong radially inward dc electric field near the mirror throats. Most of the results were for hydrogen, but deuterium and helium plasmas were also studied. Three water-cooled hollow cathodes were operated in the hot-ion plasma mode with the following results: (1) thermally emitting cathodes were not required to achieve the hot-ion mode; (2) steady-state operation (several minutes) was attained; (3) input powers greater than 40 kW were achieved; (4) cathode outside diameters were increased from 1.2 cm (uncooled) to 4.4 cm (water-cooled); (5) steady-state hydrogen plasma with ion temperatures from 185 to 770 eV and electron temperatures from 5 to 21 eV were produced. Scaling relations were empirically obtained for discharge current, ion temperature, electron temperature, and relative ion density as a function of hydrogen gas feed rate, magnetic field, and cathode voltage. Neutrons were produced from deuterium plasma, but it was not established whether thay came from the plasma volume or from the electrode surfaces.

Reinmann, J. J.↗

Hot ion plasma production in HIP-1 using water-cooled hollow cathodes

The paper reports on hot-ion plasma experiments conducted in a magnetic mirror facility. A steady-state E x B plasma was formed by applying a strong radially inward dc electric field near the mirror throats. Most of the results were for hydrogen, but deuterium and helium plasmas were also studied. Three water-cooled hollow cathodes were operated in the hot-ion plasma mode with the following results: (1) thermally emitting cathodes were not required to achieve the hot-ion mode; (2) steady-state operation (several minutes) was attained; (3) input powers greater than 40 kW were achieved; (4) cathode outside diameters were increased from 1.2 cm (uncooled) to 4.4 cm (water-cooled); (5) steady-state hydrogen plasmas with ion temperatures from 185 to 770 eV and electron temperatures from 5 to 21 eV were produced. Scaling relations were empirically obtained for discharge current, ion temperature, electron temperature, and relative ion density as a function of hydrogen gas feed rate, magnetic field, and cathode voltage.

Reinmann, J. J.↗

Progress in understanding the enhanced pedestal H-mode in NSTX

The paper describes the enhanced pedestal (EP) H-mode observed in the National Spherical Torus Experiment (NSTX). The defining characteristics of EP H-mode are given, namely i)transition after the L- to H-mode transition, ii) region of very steep ion temperature gradient, and iii) associated region of strong rotational shear. A newly observed long-pulse EP H-mode example shows quiescent behavior for as long as the heating and current drive sources are maintained. Cases are shown where the region of steep ion temperature gradient is located at the very edge, and cases where it is shifted up to 10 cm inward from the plasma edge; these cases are united by a common dependence of the ion temperature gradient on the toroidal rotation frequency shear. EP H-mode examples have been observed across a wide range of q95 and pedestal collisionality. No strong changes in the fluctuation amplitudes have been observed following the eP H-mode transition, and transport analysis indicates that the ion t hermal transport is comparable to or less than anticipated from a simple neoclassical transport model. Cases are shown where EP H-modes were reliably generated, through these low-q95 examples were difficult to sustain. A case where an externally triggered ELM precipitates the transition to EP H-mode is also shown, though an initial experiment designed to trigger EP-H-modes in this fashion was successful.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress In Understanding The Enhanced Petestal H-mode In NSTX

This paper describes the enhanced pedestal (EP) H-mode observed in the National Spherical Torus Experiment (NSTX). The defining characteristics of EP H-mode are given, namely i) transition after the L- to H-mode transition, ii) region of very steep ion temperature gradient, and iii) associated region of strong rotational shear. A newly observed long-pulse EP H-mode example shows quiescent behavior for as long as the heating and current drive sources are maintained. Cases are shown where the region of steep ion temperature gradient is located at the very edge, and cases where it is shifted up to 10 cm inward from the plasma edge; these cases are united by a common dependence of the ion temperature gradient on the toroidal rotation frequency shear. EP H-mode examples have been observed across a wide range of q 95 and pedestal collisionality. No strong changes in the fluctuation amplitudes have been observed following the eP H-mode transition, and transport analysis indicates that the ion thermal transport is comparable to or less than anticipated from a simple neoclassical transport model. Cases are shown where EP H-modes were reliably generated, through these low-q 95 examples were difficult to sustain. A case where an externally triggered ELM precipitates the transition to EP H-mode is also shown, though an initial experiment designed to trigger EP-H-modes in this fashion was successful.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Vortex motion of dust particles due to non-conservative ion drag force in a plasma

Vortex motion of the dust in a dusty plasma is shown to result because non-parallelism of the ion density gradient and the gradient of the magnitude of the ion ambipolar velocity cause the ion drag force on dust grains to be non-conservative. Furthermore, dust grain poloidal vortices consistent with the model predictions are experimentally observed, and the vortices change character with imposed changes in the ion temperature profile as predicted. For a certain ion temperature profile, two adjacent co-rotating poloidal vortices have a well-defined X-point analogous to the X-point in magnetic reconnection.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effect of discharge chamber wall temperature on ion thruster performance

Experiments conducted on a ring cusp ion thruster that could be maintained at temperatures in the range 80 K to 500 K during operation by cooling it with liquid nitrogen are described. The measured changes in performance induced by discharge chamber wall temperature changes are compared to those predicted by a simple discharge chamber model. Good agreement between the temperature induced effects predicted by the model and measured results are demonstrated. Decreases in wall temperature to about 90 K are shown to effect substantial improvements in performance.

Wilbur, P. J.↗

Microscopic filamentation due to electrothermal instability and plasma heating in time-dependent solar transition layer

Nonlinear equilibrium states of a microscopic current filamentation (electrothermal instability) in the solar atmosphere are explored. This phenomenon occurs for transition zone ion temperature plasmas provided that the electron to ion temperature ratio exceeds 1. It is shown that when the onset condition for the electrothermal instability is satisfied, the instability drives a current filamentation to a nonlinear equilibrium state that has a spatially periodic electron temperature variation with wavelength.

Hinata, Satoshi↗

A two-dimensional model of the ionosphere of Venus - Thermal structure

A spectral model is defined for the electron and ion temperature profiles of the Venus ionosphere. The model is developed using data collected with the retarding potential analyzer on the Pioneer Venus Orbiter, and account is taken of horizontal bulk heat transport and a heat flux saturation effect. Coupled ion and energy equations and thermal flux equations are defined. A finite difference algorithm is applied to solve the equations, assuming an ionopause at 740 km altitude. Horizontal plasma flow velocities of 2.5-5.6 km/sec are found necessary in order to account for a dip in the ion temperature around the terminator and a sharp rise at about 140 deg, i.e., far past the solar zenith angle. An external heat source of 0.0001-0.0002 ergs/sq cm per sec, uniformly distributed around Venus, is required to maintain observed dayside and nightside ion temperatures. The heat source may be the solar wind, which would be sufficient without shocks.

Singhal, R. P.↗

Metallic glass as a temperature sensor during ion plating

The temperature of the interface and/or a superficial layer of a substrate during ion plating was investigated using a metallic glass of the composition Fe67Co18B14Si1 as the substrate and as the temperature sensor. Transmission electron microscopy and diffraction studies determined the microstructure of the ion-plated gold film and the substrate. Results indicate that crystallization occurs not only in the film, but also in the substrate. The grain size of crystals formed during ion plating was 6 to 60 nm in the gold film and 8 to 100 nm in the substrate at a depth of 10 to 15 micrometers from the ion-plated interface. The temperature rise of the substrate during ion plating was approximately 500 C. Discontinuous changes in metallurgical microstructure, and physical, chemical, and mechanical properties during the amorphous to crystalline transition in metallic glasses make metallic glasses extremely useful materials for temperature sensor applications in coating processes.

Miyoshi, K.↗

Metallic glass as a temperature sensor during ion plating

The temperature of the interface and/or a superficial layer of a substrate during ion plating was investigated using a metallic glass of the composition Fe67Co18B14Si1 as the substrate and as the temperature sensor. Transmission electron microscopy and diffraction studies determined the microstructure of the ion-plated gold film and the substrate. Results indicate that crystallization occurs not only in the film, but also in the substrate. The grain size of crystals formed during ion plating was 6 to 60 nm in the gold film and 8 to 100 nm in the substrate at a depth of 10 to 15 micrometers from the ion-plated interface. The temperature rise of the substrate during ion plating was approximately 500 C. Discontinuous changes in metallurgical microstructure, and physical, chemical, and mechanical properties during the amorphous to crystalline transition in metallic glasses make metallic glasses extremely useful materials for temperature sensor applications in coating processes.

Miyoshi, K.↗

Neutron yield enhancement and suppression by magnetization in laser-driven cylindrical implosions

In inertial confinement fusion, an externally applied magnetic field can reduce heat losses in the compressing fuel thereby increasing neutron-averaged ion temperatures and neutron yields. Yet, magnetization is only beneficial if the magnetic pressure remains negligible compared to the fuel pressure. Experiments and three-dimensional magneto-hydrodynamic simulations of cylindrical implosions on the OMEGA laser show ion temperature and neutron yield enhancements of up to 44% and 67%, respectively. As the applied, axial magnetic field is increased to nearly 30T, both experiments and simulations show yield degradation. For magnetized, cylindrical implosions, there exists an optimal magnetic field that maximizes the increase in yield. Limiting the fuel convergence ratio by preheating the fuel can further increase the benefit of magnetization. The findings demonstrate that it is possible to create a plasma with a density of order 1 g/cm 3 and an ion temperature greater than 1 keV with a magnetic pressure comparable to the thermal pressure, a new regime for laser-produced plasmas on OMEGA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small amplitude dust ion-acoustic solitary waves and double layers in a dusty plasma with flat-topped electron distribution

The properties of small but finite amplitude dust ion-acoustic (DIA) solitary waves (SWs) as well double layers (DLs) in a dusty plasma containing warm adiabatic ions, electrons following flat-topped velocity distribution, and arbitrarily (positively or negatively) charged immobile dust are studied. The effects of ion-temperature, resonant electrons, and dust number density are found to significantly modify the criteria for the existence of the DIA SWs and DLs, as well as significantly modify their basic features. It is also shown that the ion-temperature reduces the possibility for the formation of these localized structures, and that their amplitude decreases (increases) with the increase in the negative (positive) dust number density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction and verification of x-ray imaging crystal spectrometer analysis on Wendelstein 7-X through x-ray ray tracing

X-ray ray tracing is used to develop ion-temperature corrections for the analysis of the X-ray Imaging Crystal Spectrometer (XICS) used at Wendelstein 7-X (W7-X) and perform verification on the analysis methods. The XICS is a powerful diagnostic able to measure ion-temperature, electron-temperature, plasma flow, and impurity charge state densities. While these systems are relatively simple in design, accurate characterization of the instrumental response and validation of analysis techniques are difficult to perform experimentally due to the requirement of extended x-ray sources. For this reason, a ray tracing model has been developed that allows characterization of the spectrometer and verification of the analysis methods while fully considering the real geometry of the XICS system and W7-X plasma. Through the use of ray tracing, several important corrections have been found that must be accounted for in order to accurately reconstruct the ion-temperature profiles. The sources of these corrections are described along with their effect on the analyzed profiles. The implemented corrections stem from three effects: (1) effect of sub-pixel intensity distribution during de-curving and spatial binning, (2) effect of sub-pixel intensity distribution during forward model evaluation and generation of residuals, and (3) effect of defocus and spherical aberrations on the instrumental response. Possible improvements to the forward model and analysis procedures are explored, along with a discussion of trade-offs in terms of computational complexity. Finally, the accuracy of the tomographic inversion technique in stellarator geometry is investigated, providing for the first time a verification exercise for inversion accuracy in stellarator geometry and a complete XICS analysis tool-chain.

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗