Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERFEROMETER SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Development of non-intrusive instrumentation for NASA-Ames Ballistic Range and Shock Tunnel

The use of nonintrusive instrumentation in high-enthalpy facilities offers the opportunity to collect data that has previously been difficult or impossible to obtain. Three such instruments, now under development, are described: an OH absorption system which can measure OH species concentration and temperature, a holographic interferometer for flow visualization and density measurement at low density, and a telemetry system which allows the measurement of surface quantities on model in free-flight at hypervelocity. The challenges and opportunities encountered when employing these advanced diagnostics to high-enthalpy facilities are discussed.

Strawa, A. W.↗

Swept Frequency Laser Metrology System

A swept frequency laser ranging system having sub-micron accuracy that employs multiple common-path heterodyne interferometers, one coupled to a calibrated delay-line for use as an absolute reference for the ranging system. An exemplary embodiment uses two laser heterodyne interferometers to create two laser beams at two different frequencies to measure distance and motions of target(s). Heterodyne fringes generated from reflections off a reference fiducial X(sub R) and measurement (or target) fiducial X(sub M) are reflected back and are then detected by photodiodes. The measured phase changes Delta phi(sub R) and Delta phi (sub m) resulting from the laser frequency swept gives target position. The reference delay-line is the only absolute reference needed in the metrology system and this provides an ultra-stable reference and simple/economical system.

Zhao, Feng↗

A sensitive high repetition rate arrival time monitor for X-ray free electron lasers

X-ray free-electron laser sources enable time-resolved X-ray studies with unmatched temporal resolution. To fully exploit ultrashort X-ray pulses, timing tools are essential. However, new high repetition rate X-ray facilities present challenges for currently used timing tool schemes. Here we address this issue by demonstrating a sensitive timing tool scheme to enhance experimental time resolution in pump-probe experiments at very high pulse repetition rates. Our method employs a self-referenced detection scheme using a time-sheared chirped optical pulse traversing an X-ray stimulated diamond plate. By formulating an effective medium theory, we confirm subtle refractive index changes, induced by sub-milli-Joule intense X-ray pulses, that are measured in our experiment. The system utilizes a Common-Path-Interferometer to detect X-ray-induced phase shifts of the optical probe pulse transmitted through the diamond sample. Owing to the thermal stability of diamond, our approach is well-suited for MHz pulse repetition rates in superconducting linear accelerator-based free-electron lasers.

47 OTHER INSTRUMENTATION↗

Internal measurements of electromagnetic geodesic acoustic mode (GAM) in EAST plasmas

Velocity, density, and magnetic fluctuations of the geodesic acoustic mode (GAM) have been measured using the Doppler backscattering system, Faraday-effect polarimeter-interferometer, and external pick-up coils in the Experimental Advanced Superconducting Tokamak. Simultaneous measurements of density and velocity fluctuations at the midplane and top of plasmas demonstrate that m = 1 density fluctuations are quantitatively balanced by the compression of perpendicular flow fluctuations. Furthermore, internal magnetic fluctuations associated with GAM have now been directly measured by laser-based Faraday-effect polarimetry for the first time. Line-averaged magnetic fluctuations (up to 16 Gauss, B̃¯R,GAMBT∼0.066%) are significantly larger than those extrapolated from edge coils (a few Gauss) and that magnetic fluctuations increase with β. The observed discrepancy between finite β theory and experimental data indicates the need for further theoretical investigations.

Physics↗

Laser adaptive holographic hydrophone

A new type of a laser hydrophone based on dynamic holograms, formed in a photorefractive crystal, is proposed and studied. It is shown that the use of dynamic holograms makes it unnecessary to use complex optical schemes and systems for electronic stabilisation of the interferometer operating point. This essentially simplifies the scheme of the laser hydrophone preserving its high sensitivity, which offers the possibility to use it under a strong variation of the environment parameters. The laser adaptive holographic hydrophone implemented at present possesses the sensitivity at a level of 3.3 mV Pa{sup -1} in the frequency range from 1 to 30 kHz. (laser hydrophones)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Aircraft altitude determination using multipath information in an angle-measuring navigation satellite system

In an angle-measuring navigation satellite system using a pair of crossed interferometers located on a satellite in synchronous orbit, three parameters are needed to determine a user's position unambiguously. These are the phase differences between received signals which were transmitted by the two antennas on each of the two interferometers, and the user's altitude. The two phase difference measurements yield a line of possible user locations, and the addition of the altitude measurement reduces this line to a single point. A method is proposed which makes use of the navigation signals received after reflection off the earth's surface. The iterative procedure employs the arrival time difference between direct and reflected signals. Based on previous calculations of errors in measuring the electrical parameters it is concluded that, for North Atlantic coverage and specular reflection, altitude measurements can be made with a 1-sigma error of 65 meters.

Kurjan, D.↗

Laser measuring system for incremental assemblies

Wire-wrapped frame assemblies used in spark chambers and the like can be measured using a system which utilizes a laser, an interferometer, and a retroreflector to precisely measure distance. A light source and a photodetector are located adjacent the incremental assembly and mounted on a movable carriage. The interferometer is also mounted on the movable carriage, while the laser and retroreflector are positioned at either end of the carriage track. The carriage is moved along one edge of the incremental assembly between the retroreflector and the laser, and as the carriage is moved, the light from the light source to the photodetector is interrupted. This produces a trigger command to a control unit which in turn causes a distance measurement to be made. A printout is provided for each sampling trigger command to list such items as ideal position, actual position and amount of error.

Etzel, J. G.↗

Facility for interferometric testing of 1.25-m mirrors at liquid helium temperatures

A concept is presented for a national cryogenic optics test facility capable of optical characterization of 1.25 m diameter optics having focal lengths up to 6.2 m at temperatures from 300 K to near 4 K. The facility will be comprised of a large Dewar with a phase shift interferometer, a two-stage vacuum system employing a turbomolecular pump, and an integral vibration isolation system. The entire facility will be housed in a concrete site with a massive floor to assist in reducing vibration during optical tests. By providing interchangeable sections, the overall height of the Dewar can be adjusted to provide for testing of shorter focal length optics. The background for the facility is discussed along with the facility location, and the requirements and the performance considerations which drive the Dewar design with respect to the vibration isolation system, vacuum system, and optical interferometry.

Salerno, Louis J.↗

Wide Angle, Single Screen, Gridded Square-Loop Frequency Selective Surface for Diplexing Two Closely Separated Frequency Bands

The design and performance of a wide angle, single screen, frequency selective surface (FSS) with gridded square-loop path elements are described for diplexing closely separated signal bands, for example, X- and Ku-band signals in an Orbiting Very Long Baseline Interferometer (OVLBI) earth station reflector antenna system, as well as other applications such as military and commercial communications via satellites. Excellent agreement is obtained between the predicted and measured results of this FSS design using the gridded square-loop patch elements sandwiched between 0.0889 cm thick tetrafluoroethylene fluorocarbon polymer (PTFE) slabs. Resonant frequency drift is reduced by 1 GHz with an incidence angle from 0 deg normal to 40 deg from normal.

Wu, Te-Kao↗

Scientific Applications of Optical Instruments to Materials Research

Microgravity is a unique environment for materials and biotechnology processing. Microgravity minimizes or eliminates some of the effects that occur in one g. This can lead to the production of new materials or crystal structures. It is important to understand the processes that create these new materials. Thus, experiments are designed so that optical data collection can take place during the formation of the material. This presentation will discuss scientific application of optical instruments at MSFC. These instruments include a near-field scanning optical microscope, a miniaturized holographic system, and a phase-shifting interferometer.

Witherow, William K.↗

Lessons Learned During Cryogenic Optical Testing of the Advanced Mirror System Demonstrators (AMSDs)

Optical testing in a cryogenic environment presents a host of challenges above and beyond those encountered during room temperature testing. The Advanced Mirror System Demonstrators (AMSDs) are 1.4 m diameter, ultra light-weight (<20 kg/mA2), off-axis parabolic segments. They are required to have 250 nm PV & 50 nm RMS surface figure error or less at 35 K. An optical testing system, consisting of an Instantaneous Phase Interferometer (PI), a diffractive null corrector (DNC), and an Absolute Distance Meter (ADM), was used to measure the surface figure & radius-of-curvature of these mirrors at the operational temperature within the X-Ray Calibration Facility (XRCF) at Marshall Space Flight Center (MSFC). The Ah4SD program was designed to improve the technology related to the design, fabrication, & testing of such mirrors in support of NASA s James Webb Space Telescope (JWST). This paper will describe the lessons learned during preparation & cryogenic testing of the AMSDs.

Hadaway, James↗

On the Antenna Pattern of Orbitting Interferometer

We consider the response of an interferometer moving with respect to a fixed reference frame, and derive a simple expression for the beam-pattern factors and the polarization-averaged antenna power pattern...Then, we consider a class of motions where the detector's plane is constrained to move on the surface of a cone of constant aperture; at the same time, the two arms are rotating around a vertical axis...In addition, we consider the case of an Earth-based interferometer...Finally, we discuss LISA's response to circularly polarized sinusoidal waves, coming from a few known binary systems in our Galaxy.

interferometer interferometry antenna motions LISA↗

Solar Confocal Interferometers for Sub-Picometer-Resolution Spectral Filters

The confocal Fabry-Perot interferometer allows sub-picometer spectral resolution of Fraunhofer line profiles. Such high spectral resolution is needed to keep pace with the higher spatial resolution of the new set of large-aperture solar telescopes. The line-of-sight spatial resolution derived for line profile inversions would then track the improvements of the transverse spatial scale provided by the larger apertures. The confocal interferometer's unique properties allow a simultaneous increase in both etendue and spectral power. Methods: We have constructed and tested two confocal interferometers. Conclusions: In this paper we compare the confocal interferometer with other spectral imaging filters, provide initial design parameters, show construction details for two designs, and report on the laboratory test results for these interferometers, and propose a multiple etalon system for future testing of these units and to obtain sub-picometer spectral resolution information on the photosphere in both the visible and near-infrared.

Gary, G. Allen↗

Black Holes, Gravitational Waves, and LISA

Binary black hole mergers are central to many key science objectives of the Laser Interferometer Space Antenna (LISA). For many systems the strongest part of the signal is only understood by numerical simulations. Gravitational wave emissions are understood by simulations of vacuum General Relativity (GR). I discuss numerical simulation results from the perspective of LISA's needs, with indications of work that remains to be done. Some exciting scientific opportunities associated with LISA observations would be greatly enhanced if prompt electromagnetic signature could be associated. I discuss simulations to explore this possibility. Numerical simulations are important now for clarifying LISA's science potential and planning the mission. We also consider how numerical simulations might be applied at the time of LISA's operation.

Baker, John↗

Laser Mode Behavior of the Cassini CIRS Fourier Transform Spectrometer at Saturn

The CIRS Fourier transform spectrometer aboard the NASA/ESA/ASI Cassini orbiter has been acquiring spectra of the Saturnian system since 2004. The CIRS reference interferometer employs a laser diode to trigger the interferogram sampling. Although the control of laser diode drive current and operating temperature are stringent enough to restrict laser wavelength variation to a small fraction of CIRS finest resolution element, the CIRS instrument does need to be restarted every year or two, at which time it may start in a new laser mode. By monitoring the Mylar absorption features in uncalibrated spectra due to the beam splitter Mylar substrate, it can be shown that these jumps are to adjacent modes and that most of the eight-year operation so far is restricted to three adjacent modes. For a given mode, the wavelength stability appears consistent with the stability of the laser diode drive curren.t and operating temperature.

Brasunas, John C.↗