Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTERCONNECTED POWER SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Multiple stack fuel cell system

A fuel cell system is disclosed comprising a plurality of fuel cell modules including a sealed planar fuel cell stack, the stack including internal manifold channels for transport of fuel and air to fuel cells within the stack and transport of tail gas and spent air away from fuel cells within the stack. Each of the fuel cell stacks is mounted on a stack footprint area of a top member of a base manifold. The base manifolds are configured to allow for interconnection of a number of fuel cell stack modules to provide a fuel cell system capable of producing power outputs that otherwise would have required large surface area cells or stack with a large number of cells.

Haltiner, Jr., Karl J.↗

DC-Connected Solar Plus Storage Modeling for Behind-the-Meter Systems in SAM

A detailed model for PV plus DC-connected batteries was developed. This model was compared to an existing AC connected battery model in the System Advisor Model (SAM) tool using a hypothetical Honolulu residence with a PV plus storage system. The stand-alone PV system was shown to provide the most value; however due to the increased difficulty of PV systems being approved for grid interconnection in Hawaii, it is valuable to install an AC or DC connected battery to enable full PV self-consumption under a less restrictive interconnection option. In that case both battery systems enabled full PV self consumption at the residence, requiring no power to be exported to the grid. The DC-connected battery system captured energy from the PV array which would have also been clipped due to inverter limitations. For a PV system with DC/AC ratio of 1.23, the battery configurations produced net-present values within 1% of each other, but when the DC/AC ratio increased to 1.85, the DC-connected system increased the net-present value by 13%.

14 SOLAR ENERGY↗

Architecture for Web-Based Visualization of Large-Scale Energy Domains: Preprint

With the growing penetration of inverter-based distributed energy resources and increased loads through electrification, power systems analyses are becoming more important and more complex. Moreover, these analyses increasingly involve the combination of interconnected energy domains with data that are spatially and temporally increasing in scale by orders of magnitude, surpassing the capabilities of many existing analysis and decision-support systems. We present the architectural design, development, and application of a high-resolution web-based visualization environment capable of cross-domain analysis of tens of millions of energy assets, focusing on scalability and performance. Our system supports the exploration, navigation, and analysis of large data from diverse domains such as electrical transmission and distribution systems, mobility and electric vehicle charging networks, communications networks, cyber assets, and other supporting infrastructure. We evaluate this system across multiple use cases, describing the capabilities and limitations of a web-based approach for high-resolution energy system visualizations.

grid modernization↗

Mississippi State University Cooling, Heating, and Power (Micro-CHP) and Bio-Fuel Center

Between 2008 and 2014, the U.S. Department of Energy funded the MSU Micro-CHP and Bio-Fuel Center located at Mississippi State University. The overall objective of this project was to enable micro-CHP (micro-combined heat and power) utilization, to facilitate and promote the use of CHP systems and to educate architects, engineers, and agricultural producers and scientists on the benefits of CHP systems. Therefore, the work of the Center focused on the three areas: CHP system modeling and optimization, outreach, and research. In general, the results obtained from this project demonstrated that CHP systems are attractive because they can provide energy, environmental, and economic benefits. Some of these benefits include the potential to reduce operational cost, carbon dioxide emissions, primary energy consumption, and power reliability during electric grid disruptions. The knowledge disseminated in numerous journal and conference papers from the outcomes of this project is beneficial to engineers, architects, agricultural producers, scientists and the public in general who are interested in CHP technology and applications. In addition, more than 48 graduate students and 23 undergraduate students, benefited from the training and research performed in the MSU Micro-CHP and Bio-Fuel Center. The project scope consisted of six separate, but related areas: 1. Micro-CHP modeling - Computational simulations and verification/validation studies of selected models for technical and economic viability. 2. Fuel flexibility in micro-CHP applications – Demonstrating and quantifying the operation of micro-CHP systems on alternative fuels. 3. Outreach activities – Providing provide educational materials for engineers and architects and conducting outreach seminars, workshops, and demonstrations for engineers and architects as well as for more general audiences. 4. Biofuel and opportunity fuel processing and utilization – Determining the processing requirements and feasibility to utilize biofuels and disaster debris for micro-CHP systems. 5. CHP Systems Optimization – Optimization of internal combustion and Stirling engines integrated with heat recovery systems for CHP operation. 6. Distributed Generation and Grid Interconnection – Developing requirements and control systems for interconnection of micro-CHP systems with the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Security Testing and Training Programs for Industrial Control Systems

Service providers rely on industrial control systems (ICS) to manage the flow of water at dams, open breakers on power grids, control ventilation and cooling in nuclear power plants, and more. In today's interconnected environment, this can present a serious cyber security challenge. To combat this growing challenge, government, private industry, and academia are working together to reduce cyber risks. The Idaho National Laboratory (INL) is a key contributor to the Department of Energy National SCADA Test Bed (NSTB) and the Department of Homeland Security (DHS) Control Systems Security Program (CSSP), both of which focus on improving the overall security posture of ICS in the national critical infrastructure. In support of the NSTB, INL hosts a dedicated SCADA testing facility which consists of multiple control systems supplied by leading national and international manufacturers. Within the test bed, INL researchers systematically examine control system components and work to identify vulnerabilities. In support of the CSSP, INL develops and conducts training courses which are designed to increase awareness and defensive capabilities for IT/Control System professionals. These trainings vary from web-based cyber security trainings for control systems engineers to more advanced hands-on training that culminates with a Red Team/ Blue Team exercise that is conducted within an actual control systems environment. INL also provides staffing and operational support to the DHS Industrial Control Systems Cyber Emergency Response Team (ICS-CERT) Security Operations Center which responds to and analyzes control systems cyber incidents across the 18 US critical infrastructure sectors.

13 HYDRO ENERGY↗

Power grid frequency prediction using spatiotemporal modeling

Understanding power system dynamics is essential for interarea oscillation analysis and the detection of grid instabilities. The FNET/GridEye is a GPS-synchronized wide-area frequency measurement network that provides an accurate picture of the normal real-time operational condition of the power system-dynamics, giving rise to new and intricate spatiotemporal patterns of power loads. We propose to model FNET/GridEye grid frequency data from the U.S. Eastern Interconnection with a spatiotemporal statistical model. We predict the frequency data at locations without observations, a critical need during disruption events where measurement data are inaccessible. Spatial information is accounted for either as neighboring measurements in the form of covariates or with a spatiotemporal correlation model captured by a latent Gaussian field. Finally, the proposed method is useful in estimating power system dynamic response from limited phasor measurements and holds promise for predicting instability that may lead to undesirable effects such as cascading outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Power Flow Solution Methods for Combined Transmission and Distribution Systems

High distributed PV penetration makes the distribution systems more active and increases their impact on the upstream transmission grid. To facilitate the studies on this area, this paper proposes a power flow (PF) model and formulation of combined transmission and distribution (T&D) power systems. The formulation is based on the physical coupling of transmission and distribution grids. The unbalanced nature of distribution feeders and voltage regulators are modeled so that the resulting PF balance equations in distribution systems are similar to those in the interconnected transmission system. The formulated nonlinear PF equations are solved using the proposed unified and sequential methods. Both methods are verified and compared with each other using several combined T&D power systems. A multi-period PF simulation is also included to demonstrate the capability of the proposed formulation and solution methods in capturing the influences of high distributed PV penetration on transmission level.

Nguyen, Quan H.↗

Use of Hardware-in-the-Loop to De-Risk Field Deployment of Hydrogen Assets

Grid-forming assets are required in microgrids to act as voltage-frequency masters. These grid-forming assets can operate in two modes of operation: grid-following mode and grid-forming mode. In grid-following mode of operation, these assets will follow real power and reactive power setpoints and in grid-forming mode of operation these assets will follow voltage and frequency setpoints. Traditionally, diesel generators or natural gas-based generators are widely used to act as a voltage-frequency master. However, many utilities are aiming to replace generators with grid forming-inverters supplied by solar photovoltaics (PV), batteries or fuel cells. Since grid-forming assets need a long-term reliable energy source, fuel cells are a reasonable and viable choice to supply the grid-forming inverters, but some of the challenges facing the wide deployment of grid-forming fuel cell inverters need to be addressed. Specifically, in our proposed work, we aim to focus on the interconnection and interoperability requirements of grid-forming fuel cell inverters. Currently, state-of-the-art fuel cell inverters follow the general interconnection requirements of distributed energy resources (DERs) and general interoperability requirements of DERs, but these requirements were built with PV and battery systems in mind. Fuel cells have different operational requirements, and therefore these requirements need to be appropriately modified for the grid operators to use. These additional steps add to the investment and operational cost to the grid operators. Through the ARIES platform, this proposed project aims to bridge this gap and use power hardware-in-the-loop (PHIL) and controller hardware-in-the-loop (CHIL) experiments to inform the creation of open-source interconnection and interoperability information that can aid in faster and cheaper installation and operation of grid-forming fuel cell inverters.

08 HYDROGEN↗

Impacts of hybridization and forecast errors on the probabilistic capacity credit of batteries

Battery storage is increasingly identified as being among the least-cost mix of technologies in the evolving U.S. electricity mix. This study explores the marginal capacity credit of batteries using a probabilistic, reliability-based, effective firm capacity method, which we apply for multiple battery power ratings, durations, coupling types, deployment locations, and dispatch profiles within a test system that is based on the Texas Interconnection in the year 2024. We find that the capacity credits for all battery durations depend on their ability to predict the timing of reliability events. Even 1-2 h forecast errors - resulting in early or delayed battery discharging relative to the onset of a reliability event - lead pronounced capacity credit reductions, especially for 4-h duration batteries. Coupling batteries with solar mitigates the uncertainty associated with a shorter-duration battery's availability during reliability events, primarily due to the relatively high solar capacity credit in our test system. Coupled (or hybrid) system designs with oversized solar arrays, the ability to charge the coupled battery with grid energy, and larger batteries lead to the greatest capacity credit benefits of hybridization. We do not see evidence that the hybrid capacity credit exceeds the sum of the separate battery and solar capacity credits.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Communications and control for electric power systems

The first section of the report describes the AbNET system, a hardware and software communications system designed for distribution automation (it can also find application in substation monitoring and control). The topology of the power system fixes the topology of the communications network, which can therefore be expected to include a larger number of branch points, tap points, and interconnections. These features make this communications network unlike any other. The network operating software has to solve the problem of communicating to all the nodes of a very complex network in as reliable a way as possible even if the network is damaged, and it has to do so with minimum transmission delays and at minimum cost. The design of the operating protocols is described within the framework of the seven-layer Open System Interconnection hierarchy of the International Standards Organization. Section 2 of the report describes the development and testing of a high voltage sensor based on an electro-optic polymer. The theory of operation is reviewed. Bulk fabrication of the polymer is discussed, as well as results of testing of the electro-optic coefficient of the material. Fabrication of a complete prototype sensor suitable for use in the range 1-20 kV is described. The electro-optic polymer is shown to be an important material for fiber optic sensing applications. Appendix A is theoretical support for this work. The third section of the report presents the application of an artificial neural network, Kohonen's self-organizing feature map, for the classification of power system states. This classifier maps vectors of an N-dimensional space to a 2-dimensional neural net in a nonlinear way preserving the topological order of the input vectors. These mappings are studied using a nonlinear power system model.

Kirkham, H.↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop (Poster)

This poster describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1TM. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Contingency Analysis Tool 2.0 User Manual with Test System Examples

This document introduces Version 2 of the Dynamic Contingency Analysis Tool (DCAT) software package developed by Pacific Northwest National Laboratory and serves as a guide for using this package to conduct cascading failure simulations for the electric power system. The DCAT is an open-platform and publicly available software; it is intended to help develop applications that aim to improve the capabilities of power system planning engineers to assess the impact and likelihood of extreme contingencies and potential cascading events across their systems and interconnections. Outputs from the DCAT will support finding mitigating actions to reduce the risk of cascading outages in technically sound and effective ways. This manual provides detailed instructions on how to use this tool on multicore Windows workstations or servers. In the public version of DCAT, several improvements have been made over the previous version: (1) it was modularized; (2) a graphical user interface (GUI) was developed; (3) a new version of the MPjobs parallel processing module was incorporated; and (4) a batch-processing function was added. The features of the DCAT GUI are described, including some examples of how to use the GUI to perform simulations. A full explanation of the DCAT methodology is available in the Phase 1 report.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Analysis of System Balance and Architectural Trends Based on Top500 Supercomputers

Supercomputer design is a complex, multi-dimensional optimization process, wherein several subsystems need to be reconciled to meet a desired figure of merit performance for a portfolio of applications and a budget constraint. However, overall, the HPC community has been gravitating towards ever more FLOPS, at the expense of many other subsystems. To draw attention to overall system balance, in this paper, we analyze balance ratios and architectural trends in the world's most powerful supercomputers. Specifically, we have collected performance characteristics of systems between1993 and 2018 based on the Top500 lists, and then analyzed their architectures from diverse system design perspectives. Notably, our analysis studies the performance balance of the machines, across a variety of subsystems such as compute, memory, I/O, interconnect, intra-node connectivity and power. Our analysis reveals that balance ratios of the various subsystems need to be considered carefully alongside the application workload portfolio to provision the subsystem capacity and bandwidth specifications, which can help achieve optimal performance.

97 MATHEMATICS AND COMPUTING↗

Integrating Renewable Energy into the Transmission and Distribution System of the U. S. Virgin Islands

This report focuses on the economic and technical feasibility of integrating renewable energy technologies into the U.S. Virgin Islands transmission and distribution systems. The report includes three main areas of analysis: 1) the economics of deploying utility-scale renewable energy technologies on St. Thomas/St. John and St. Croix; 2) potential sites for installing roof- and ground-mount PVsystems and wind turbines and the impact renewable generation will have on the electrical subtransmission and distribution infrastructure, and 3) the feasibility of a 100- to 200-megawatt power interconnection of the Puerto Rico Electric Power Authority (PREPA), Virgin Islands Water and Power Authority (WAPA), and British Virgin Islands (BVI) grids via a submarine cable system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

CERF: IM3 Projected Western US Power Plant Locations

Overview The Capacity Expansion Regional Feasibility (CERF) model is an open-source geospatial python package that provides new power plant locations at a 1km resolution. The model ingests U.S. state or regional-scale electricity system capacity expansion plans, such as those produced by the Global Change Analysis Model (GCAM-USA), and identifies feasible, site-specific locations for individual new power plants (renewable and non-renewable). CERF combines high-resolution geospatial suitability analyses with an economic algorithm that selects individual plant siting locations based on grid interconnection costs and the locational marginal value of new generation. The model incorporates a wide range of dynamic constraints and opportunities, such as protected lands, population density, existing infrastructure, and water availability. This dataset provides CERF power plant siting results for IM3 Phase 2 simulations across eight different scenarios for the Western US through 2055. The scenarios include combinations of two Shared Socioeconomic Pathways (SSP3 and SSP5) with four high-resolution climate projections specific to the United States (see, https://tgw-data.msdlive.org/). These climate projections include "hotter" and "cooler" variants for two Representative Concentration Pathways (RCP4.5 and RCP8.5). The resulting eight simulations are: rcp45cooler_ssp3 rcp45cooler_ssp5 rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85cooler_ssp3 rcp85cooler_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 CERF siting results in this dataset correspond to capacity expansion plans in the GCAM-USA IM3 Phase 2 simulation data and are available for each of the above scenarios. Data Details Temporal Range: 2015-2055 in 5-year timesteps. Note that 2015 is the experiment base year and 2020 and beyond represent model simulation years. Spatial Range: Plant locations are provided for the eleven states in the Western US including Arizona, California, Colorado, Idaho, Montana, New Mexico, Nevada, Oregon, Utah, Washington, and Wyoming. Spatial Resolution: 1 km-squared, provided in x and y coordinates Geospatial Projection: Albers Equal Area Conic (ESRI:102003) File Type: csv The dataset contains subdirectories for each of the eight scenarios described in the overview. Each scenario folder contains two subfolders with the following information: 1. Power Plant Data This directory contains a single .csv file of power plant locations for both pre-existing (non-CERF sited plants in operation in 2015) and new (CERF-sited) power plants across the temporal range along with additional CERF model output parameters for CERF-sited plants. Plant with a siting year earlier than 2020 correspond to facilities that are operational leading into the first timestep CERF simulation. For a more detailed description of CERF model output parameters, see the CERF model documentation. Note that the cerf_plant_id parameter is unique within each scenario file but not across scenario files. Parameter Descriptions scenario - Name of scenario cerf_plant_id - Unique siting identifier cerf_sited - If True, indicates that plant was sited by CERF model. If False, indicates pre-existing facility region_name - Name of region (state) tech_id - Technology ID tech_name - Full generation technology name inclusive of cooling type (if applicable) and additional characteristics tech_simple - Simplified generation technology type unit_size_mw - Power plant unit size (MW) xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) index - Index position in the flattend 2D array buffer_in_km - Exclusion buffer around site (km) sited_year - Year of siting retirement_year - Year of retirement lmp_zone - Locational marginal price (LMP) zone ID locational_marginal_price_usd_per_mwh - Locational marginal price ($/MWh) generation_mwh_per_year - Generation output (MWh/yr) operating_cost_usd_per_year - Cost of plant operations ($/yr) net_operational_value - Net operational value based on LMP and and operating costs ($/yr) interconnection_cost - Cost of interconnection for transmission & gas pipeline (if applicable) net_locational_cost -- Difference of interconnection cost and operating value ($/yr) capacity_factor_fraction - Capacity factor (fraction) carbon_capture_rate_fraction - Carbon capture rate (fraction) fuel_co2_content_tons_per_btu - Fuel CO2 content (tons/Btu) fuel_price_usd_per_mmbtu - Fuel price ($/MMBtu) fuel_price_esc_rate_fraction - Fuel price escalation rate (fraction) heat_rate_btu_per_kWh - Heat rate (Btu/kWh) lifetime_yrs - Technology lifetime for annuity (years) operational_life_yrs - Operational lifetime for retirement (years) variable_om_usd_per_mwh - Variable operation and maintenance costs of yearly capacity use ($/MWh) variable_om_esc_rate_fraction - Variable operation and maintenance costs escalation rate (fraction) carbon_tax_usd_per_ton - Carbon tax ($/ton) carbon_tax_esc_rate_fraction - Carbon tax escalation rate (fraction) 2. Storage Data This directory contains information on new and pre-existing energy storage facilities operational in each timestep along with various storage operational parameters. The 2015 timestep provides pre-existing energy storage data and corresponds with facilities that are operational leading into the first model simulation timestep. Note that coordinates in the storage files correspond to the interconnection point on the grid (substation location), not individual energy storage locations. Energy storage is added in a cumulative process at each given interconnection point. That is, each individual file provides the total operational storage capacity interconnected to the specified substation for the given timestep, inclusive of previously installed storage at that location and new storage installed in that timestep at that location. Parameters scenario - Name of scenario timestep - Simulation timestep name - Unique storage identifier s_typ - Type of energy storage technology (battery or pumped storage hydro) s_node - Node ID of interconnecting substation xcoord - X coordinate in the default CRS (meters) ycoord - Y coordinate in the default CRS (meters) charge_rate - Maximum charge rate (power capacity) of storage system (MW) discharge_rate - Maximum discharge rate (power capacity) of storage system (MW) duration - Duration of storage system (hours) max_SoC - Allowed maximum state of charge (energy capacity) of storage system (MWh) min_SoC -Allowed minimum state of charge (energy capacity) of storage system (MWh) charge_eff - Efficiency of charge (fraction between 0 and 1) discharge_eff - Efficiency of discharge (fraction between 0 and 1) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

CERF↗

Alternative Approaches for Incentivizing the Frequency Responsive Reserve Ancillary Service

Frequency responsive reserve is the autonomous response of generators and demand response to deviations of system frequency, usually as a result of the instantaneous outage of a large supplier. Frequency responsive reserve arrests the frequency decline resulting in the stabilization of system frequency, and avoids the triggering of under-frequency load-shedding or the reaching of unstablefrequencies that could ultimately lead to system blackouts. It is a crucial service required to maintain a reliable and secure power system. Regions with restructured electricity markets have historically had a lack of incentives for frequency responsive reserve because generators inherently provided the response and on large interconnected systems, more than sufficient response has beenavailable. This may not be the case in future systems due to new technologies and declining response. This paper discusses the issues that can occur without proper incentives and even disincentives, and proposes alternatives to introduce incentives for resources to provide frequency responsive reserve to ensure an efficient and reliable power system.

17 WIND ENERGY↗

An Analysis of System Balance and Architectural Trends Based on Top500 Supercomputers

Supercomputer design is a complex, multi-dimensional optimization process, wherein several subsystems need to be reconciled to meet a desired figure of merit performance for a portfolio of applications and a budget constraint. However, overall, the HPC community has been gravitating towards ever more Flops, at the expense of many other subsystems. To draw attention to overall system balance, in this paper, we analyze balance ratios and architectural trends in the world’s most powerful supercomputers. Specifically, we have collected the performance characteristics of systems between 1993 and 2019 based on the Top500 lists and then analyzed their architectures from diverse system design perspectives. Notably, our analysis studies the performance balance of the machines, across a variety of subsystems such as compute, memory, I/O, interconnect, intra-node connectivity and power. Our analysis reveals that balance ratios of the various subsystems need to be considered carefully alongside the application workload portfolio to provision the subsystem capacity and bandwidth specifications, which can help achieve optimal performance.

Khan, Awais↗

Improving the Performance of Integrated Power-Hardware-in-the-Loop and Quasi-Static Time-Series Simulations

This paper introduces a novel multirate cosimulation architecture that overcomes previous challenges integrating faster real-time, microseconds-scale, power-hardware-in-the-loop (PHIL) with larger scale but slower, real-time, seconds-scale, quasi-static time-series (QSTS) simulation. Specifically, an intermediate reduced-equivalent electromagnetic transient (EMT) model duplicates the key power system topology to capture high-speed dynamics and converge hardware-power system interactions between QSTS updates. Exchanging multidimensional parameter vectors (loads, control status, etc.) between the QSTS and EMT models enables capturing the interactions of the rich, high-node-count (thousands of electrical nodes) QSTS model with the hardware. This architecture offers full spatial resolution from QSTS, including individual load dynamics, actual distribution management system controls, and nodal voltages. Simultaneously, the intermediate EMT model provides more detailed high-speed transients of key distributed energy resource hardware interactions. In addition, we use careful PHIL interface design and the exchange of complex power data, rather than current, to further improve performance. This cosimulation architecture is demonstrated by testing a simulated distribution system with an interconnected 500-kVA advanced photovoltaic (PV) inverter in PHIL. In conclusion, the architecture successfully captured PV local volt-volt ampere reactive (volt-VAR) control interactions with the larger network under time-varying electrical and weather conditions.

42 ENGINEERING↗