Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Bayesian estimation of dose thresholds

An example is described of Bayesian estimation of radiation absorbed dose thresholds (subsequently simply referred to as dose thresholds) using a specific parametric model applied to a data set on mice exposed to 60Co gamma rays and fission neutrons. A Weibull based relative risk model with a dose threshold parameter was used to analyse, as an example, lung cancer mortality and determine the posterior density for the threshold dose after single exposures to 60Co gamma rays or fission neutrons from the JANUS reactor at Argonne National Laboratory. The data consisted of survival, censoring times and cause of death information for male B6CF1 unexposed and exposed mice. The 60Co gamma whole-body doses for the two exposed groups were 0.86 and 1.37 Gy. The neutron whole-body doses were 0.19 and 0.38 Gy. Marginal posterior densities for the dose thresholds for neutron and gamma radiation were calculated with numerical integration and found to have quite different shapes. The density of the threshold for 60Co is unimodal with a mode at about 0.50 Gy. The threshold density for fission neutrons declines monotonically from a maximum value at zero with increasing doses. The posterior densities for all other parameters were similar for the two radiation types.

NASA Discipline Radiation Health↗

Dosimetry in differentiated thyroid carcinoma (12-1402R)

Purpose: The aim of this study has been to perform a dosimetric study in the treatments of differentiated thyroid cancer (DTC) performed in our center in order to find a dose-effect correlation. Methods: Thirty patients treated for DTC with 3700 MBq of {sup 131}I have been included in this study. For reasons of radiological protection all of them spent two nights as inpatients. Dose rate at 1 m from all patients was measured approximately 20 and 44 h after the administration of the radioiodine and a whole body scan in the gamma camera was performed approximately 1 week later. With those measurements and by using a model of two compartments the activities in thyroid bed remnants and in the whole body were calculated as a function of time. The integration of both activities yields the corresponding cumulated activities. Absorbed doses to thyroid bed remnants and to the whole body can be calculated following the MIRDOSE method-that is, by multiplying the corresponding cumulated activities by the corresponding S factors. Results: The absorbed doses to thyroid bed remnants calculated in this study fall into a very wide range (13-1161 Gy) and showed the highest correlation factors with the following parameters: the absorbed dose rate to thyroid bed remnants, the cumulated activity in thyroid bed remnants, and the maximum radioiodine uptake in thyroid bed remnants. The absorbed doses to the whole body range from 0.12 to 0.23 Gy. The ablation was successful in all patients, and in spite of the wide range of absorbed doses to thyroid bed remnants obtained, no dose-effect correlation could be obtained. Conclusions: Facing DTC treatments from a dosimetric viewpoint in which a predosimetry to calculate the activity of {sup 131}I to be administered is performed is a subject difficult to handle. This statement is based on the fact that although a very wide range of absorbed doses to thyroid bed remnants was obtained (including several absorbed doses well below some dose thresholds previously published to achieve ablation of thyroid bed remnants), ablation of thyroid bed remnants was successful for all patients and therefore no dose-effect correlation could be determined.

60 APPLIED LIFE SCIENCES↗

Electron Spin Resonance Study of Fe3+ and Mn2+ Ions in 17-Year-Old Nuclear-Waste-Glass Simulants Containing PuO2 with Different Degrees of 238Pu Substitution

Three samples of a model nuclear waste glass, DRG-P1, P2, and P3, were prepared at PNNL in 1982 with identical chemical compositions but were respectively batched with 0.0, 0.1, and 0.9 wt% of 238PuO2 (half life 87.8 years) partially replacing the 1.0 wt% 239PuO2 present in DRG-P1. In 1999, samples of these glasses were sent to the Naval Research Laboratory for electron spin resonance (ESR) measurements. No radiation-induced point defects were observed. Profound alpha decay-induced changes in the ESR spectra of the batched iron-group ions were found. The spectra recorded for DRG-P1 were shown by absolute spin counts to have ESR intensities equivalent to ~85% of the sum of the batched 8.28 mole% Fe3+ and 2.79 mole% Mn2+, assuming all of those ions to behave as paramagnetic S=5/2 states at room temperature. Separate experiments and calculations ruled out the possibility of precipitated magnetite-like precipitates comprising even so much as 0.01% of the total iron. A relatively weak ESR spectral feature observed at g=4.3 is the known signature of dilute Fe3+ in glasses. However, the strongest ESR signal was found to be characterized by a first-derivative zero crossing at g=2.06 and a peak-to-peak derivative linewidth of ~150 mT, which is virtually invariant in shape with both measurement temperature and alpha-decay dose. It was discovered that these broad line shapes could be accurately simulated as weighted sums of Lorentzian shape functions of differing widths but having the same g value. The absence of any measurable anisotropy in the broad line, coupled with the temperature invariance of its width, imply the existence of extremely strong exchange interactions within clusters of Fe3+, Fe2+, Mn2+, and Ni2+ ions characterized by extremely short-range magnetic order. The result is a speromagnetic system rather than exhibiting a distinct Néel temperature. The most evident ESR effect of 17 years of 238Pu decay is the (irreversible) lowering of the intensity of the "broad line" in rough proportion to the amount of 238Pu in the sample, with concomitant increases in the amplitude of the g=4.3 feature. It was additionally observed that cooling these glasses to successively lower temperatures gives rise to reversible lowering of the broad-line intensity and increasing of the strength of the g=4.3 feature when compared with theoretical expectation for non-interacting paramagnets. The truly remarkable observation that the broad lines could be simulated as weighted sums of pure Lorentzian functions of differing widths fortuitously opened the way for high precision measurements of the ESR intensities of experimental spectra that are far broader than the magnetic field range of the available laboratory electromagnets. The areas under the simulated absorption curves fitted to the experimental spectra in the manner described provided an empirical measure of the degrees to which the present model nuclear waste glasses had been affected by alpha-decay self irradiation. Specifically, the broad-line ESR integrated-intensity data as a function of 238Pu alphadecay dose (proportional to the 238Pu doping level in these fixed-time experiments) proved to be accurately fitted by a simple saturating exponential function asymptotic to zero for infinite-time self irradiation. This result promises a precise means of extrapolating thousands of years into the future the process of "super-vitrification" that results from the creation and rapid quenching of thermal spikes due to alpha decay in glasses immobilizing 239Pu and other actinide elements. In addition, because the ESR spectra of several very different candidate high-level nuclear waste (HLW) glass compositions containing even higher amounts of Fe2O3 are also shown here to be decomposable into sums of pure Lorentzians, the analytical method we describe should be applicable to these and many other HLW glasses containing both iron-group oxides and radionuclides.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-41: Analysis of GI Dose Variability Due to Intrafraction Setup Variance

Purpose: Proton SBRT (stereotactic body radiation therapy) can be an effective modality for treatment of gastrointestinal tumors, but limited in practice due to sensitivity with respect to variation in the RPL (radiological path length). Small, intrafractional shifts in patient anatomy can lead to significant changes in the dose distribution. This study describes a tool designed to visualize uncertainties in radiological depth in patient CT's and aid in treatment plan design. Methods: This project utilizes the Shadie toolkit, a GPU-based framework that allows for real-time interactive calculations for volume visualization. Current SBRT simulation practice consists of a serial CT acquisition for the assessment of inter- and intra-fractional motion utilizing patient specific immobilization systems. Shadie was used to visualize potential uncertainties, including RPL variance and changes in gastric content. Input for this procedure consisted of two patient CT sets, contours of the desired organ, and a pre-calculated dose. In this study, we performed rigid registrations between sets of 4DCT's obtained from a patient with varying setup conditions. Custom visualizations are written by the user in Shadie, permitting one to create color-coded displays derived from a calculation along each ray. Results: Serial CT data acquired on subsequent days was analyzed for variation in RPB and gastric content. Specific shaders were created to visualize clinically relevant features, including RPL (radiological path length) integrated up to organs of interest. Using pre-calculated dose distributions and utilizing segmentation masks as additional input allowed us to further refine the display output from Shadie and create tools suitable for clinical usage. Conclusion: We have demonstrated a method to visualize potential uncertainty for intrafractional proton radiotherapy. We believe this software could prove a useful tool to guide those looking to design treatment plans least insensitive to motion for patients undergoing proton SBRT in the GI tract.

60 APPLIED LIFE SCIENCES↗

A FLINN Station at Pinon Flat Observatory

The main objectives are: (1) To develop Pinon Flat Observatory (PFO) as a prototype 'integrated' FLINN station: one from which many types of data are collected, combined, and made available to the DOSE program to enhance studies of local and regional strains; (2) To develop the theoretical framework and methods to integrate the various types of auxiliary data which are to be collected by NASA at space-geodetic sites of the FLINN network, with the aim of learning as much as possible about the nature of earth deformation; (3) To develop procedures for the efficient and useful storage and retrieval of such auxiliary data so that they may be efficiently utilized by DOSE investigators; (4) To investigate the stability of ground monumentation now used in space-geodetic measurements, including the field testing of existing and new monument designs.

Agnew, Duncan Carr↗

Validation of GPUMCD for low-energy brachytherapy seed dosimetry

Purpose: To validate GPUMCD, a new package for fast Monte Carlo dose calculations based on the GPU (graphics processing unit), as a tool for low-energy single seed brachytherapy dosimetry for specific seed models. As the currently accepted method of dose calculation in low-energy brachytherapy computations relies on severe approximations, a Monte Carlo based approach would result in more accurate dose calculations, taking in to consideration the patient anatomy as well as interseed attenuation. The first step is to evaluate the capability of GPUMCD to reproduce low-energy, single source, brachytherapy calculations which could ultimately result in fast and accurate, Monte Carlo based, brachytherapy dose calculations for routine planning. Methods: A mixed geometry engine was integrated to GPUMCD capable of handling parametric as well as voxelized geometries. In order to evaluate GPUMCD for brachytherapy calculations, several dosimetry parameters were computed and compared to values found in the literature. These parameters, defined by the AAPM Task-Group No. 43, are the radial dose function, the 2D anisotropy function, and the dose rate constant. These three parameters were computed for two different brachytherapy sources: the Amersham OncoSeed 6711 and the Imagyn IsoStar IS-12501. Results: GPUMCD was shown to yield dosimetric parameters similar to those found in the literature. It reproduces radial dose functions to within 1.25% for both sources in the 0.5< r <10 cm range. The 2D anisotropy function was found to be within 3% at r = 5 cm and within 4% at r = 1 cm. The dose rate constants obtained were within the range of other values reported in the literature.Conclusion: GPUMCD was shown to be able to reproduce various TG-43 parameters for two different low-energy brachytherapy sources found in the literature. The next step is to test GPUMCD as a fast clinical Monte Carlo brachytherapy dose calculations with multiple seeds and patient geometry, potentially providing more accurate results than the TG-43 formalism while being much faster than calculations using general purpose Monte Carlo codes.

61 RADIATION PROTECTION AND DOSIMETRY↗

Clinical Outcomes With Dose-Escalated Adaptive Radiation Therapy for Urinary Bladder Cancer: A Prospective Study

Purpose: The purpose of this study was to assess feasibility, clinical outcomes, and toxicity in patients with bladder cancer treated with adaptive, image guided radiation therapy (IGRT) for bladder preservation as a part of trimodality treatment. The role of dose escalation was also studied. Methods and Materials: Forty-four patients with localized bladder cancer were enrolled in a prospective study. They underwent maximal safe resection of bladder tumor and concurrent platinum-based chemotherapy. Patients with large tumors were offered induction chemotherapy. Radiation therapy planning was done using either 3 (n=34) or 6 (n=10) concentrically grown planning target volumes (PTV). Patients received 64 Gy in 32 fractions to the whole bladder and 55 Gy to the pelvic nodes and, if appropriate, a simultaneous integrated boost to the tumor bed to 68 Gy (equivalent dose for 2-Gy fractions assuming α/β of 10 [EQD2]{sub 10} = 68.7 Gy). Daily megavoltage (MV) imaging helped to choose the most appropriate PTV encompassing bladder for the particular day (using plan-of-the-day approach). Results: Most patients (88%) had T2 disease. Sixteen patients (36%) received neoadjuvant chemotherapy. A majority of the patients (73%) received prophylactic nodal irradiation, whereas 55% of the patients received escalated dose to the tumor bed. With a median follow-up of 30 months, the 3-year locoregional control (LRC), disease-free survival, and overall survival (OS) were 78%, 66%, and 67%, respectively. The bladder preservation rate was 83%. LRC (87% vs 68%, respectively, P=.748) and OS (74% vs 60%, respectively, P=.36) rates were better in patients receiving dose escalation. Instances of acute and late Radiation Therapy Oncology Group (RTOG) grade 3 genitourinary toxicity was seen in 5 (11%) and 2 (4%) patients, respectively. There was no acute or late RTOG grade 3 or higher gastrointestinal toxicity. Conclusions: Adaptive IGRT using plan-of-the-day approach for bladder preservation is clinically feasible, with good oncological outcomes and low rates of acute and late toxicities. Dose escalation is safe and possibly improves outcomes in bladder preservation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-I-73: Clinical Evaluation of CT Image Reconstructed Using Interior Tomography

Purpose: Radiation dose reduction has been a long standing challenge in CT imaging of obese patients. Recent advances in interior tomography (reconstruction of an interior region of interest (ROI) from line integrals associated with only paths through the ROI) promise to achieve significant radiation dose reduction without compromising image quality. This study is to investigate the application of this technique in CT imaging through evaluating imaging quality reconstructed from patient data. Methods: Projection data were directly obtained from patients who had CT examinations in a Dual Source CT scanner (DSCT). Two detectors in a DSCT acquired projection data simultaneously. One detector provided projection data for full field of view (FOV, 50 cm) while another detectors provided truncated projection data for a FOV of 26 cm. Full FOV CT images were reconstructed using both filtered back projection and iterative algorithm; while interior tomography algorithm was implemented to reconstruct ROI images. For comparison reason, FBP was also used to reconstruct ROI images. Reconstructed CT images were evaluated by radiologists and compared with images from CT scanner. Results: The results show that the reconstructed ROI image was in excellent agreement with the truth inside the ROI, obtained from images from CT scanner, and the detailed features in the ROI were quantitatively accurate. Radiologists evaluation shows that CT images reconstructed with interior tomography met diagnosis requirements. Radiation dose may be reduced up to 50% using interior tomography, depending on patient size. Conclusion: This study shows that interior tomography can be readily employed in CT imaging for radiation dose reduction. It may be especially useful in imaging obese patients, whose subcutaneous tissue is less clinically relevant but may significantly increase radiation dose.

60 APPLIED LIFE SCIENCES↗

SU-D-202-04: Validation of Deformable Image Registration Algorithms for Head and Neck Adaptive Radiotherapy in Routine Clinical Setting

Purpose: To evaluate the ROI contours and accumulated dose difference using different deformable image registration (DIR) algorithms for head and neck (H&N) adaptive radiotherapy. Methods: Eight H&N cancer patients were randomly selected from the affiliated hospital. During the treatment, patients were rescanned every week with ROIs well delineated by radiation oncologist on each weekly CT. New weekly treatment plans were also re-designed with consistent dose prescription on the rescanned CT and executed for one week on Siemens CT-on-rails accelerator. At the end, we got six weekly CT scans from CT1 to CT6 including six weekly treatment plans for each patient. The primary CT1 was set as the reference CT for DIR proceeding with the left five weekly CTs using ANACONDA and MORFEUS algorithms separately in RayStation and the external skin ROI was set to be the controlling ROI both. The entire calculated weekly dose were deformed and accumulated on corresponding reference CT1 according to the deformation vector field (DVFs) generated by the two different DIR algorithms respectively. Thus we got both the ANACONDA-based and MORFEUS-based accumulated total dose on CT1 for each patient. At the same time, we mapped the ROIs on CT1 to generate the corresponding ROIs on CT6 using ANACONDA and MORFEUS DIR algorithms. DICE coefficients between the DIR deformed and radiation oncologist delineated ROIs on CT6 were calculated. Results: For DIR accumulated dose, PTV D95 and Left-Eyeball Dmax show significant differences with 67.13 cGy and 109.29 cGy respectively (Table1). For DIR mapped ROIs, PTV, Spinal cord and Left-Optic nerve show difference with −0.025, −0.127 and −0.124 (Table2). Conclusion: Even two excellent DIR algorithms can give divergent results for ROI deformation and dose accumulation. As more and more TPS get DIR module integrated, there is an urgent need to realize the potential risk using DIR in clinical.

60 APPLIED LIFE SCIENCES↗

Impact of corrosion layer composition and thermal pretreatment on the radiolytic generation of molecular hydrogen from aluminum alloys

To fully evaluate the feasibility of extending the dry storage of aluminum-clad spent nuclear fuel (ASNF) in helium-backfilled cannisters, the amount of radiation-induced molecular hydrogen (H 2 ) generated and the impact of absorbed radiation dose on the ASNF corrosion layer composition must be accurately assessed. Here, in this study, we report a slowing in the rate of radiolytic H 2 generation for pre-corroded AA1100 and AA6061 aluminum alloy coupons irradiated to up to 53 MGy of absorbed cobalt-60 gamma dose. By exploring a variety of thermal pretreatment conditions for AA6061 coupons, we find that the “steady-state” yield of H 2 depends more on the aluminum alloy used than on the treatments applied prior to dry storage. Scanning electron microscopy and positron annihilation lifetime spectroscopy techniques also provided evidence for gamma radiation-induced defects in the corrosion layers of the investigated aluminum alloy coupons for high absorbed doses (~50 MGy), the consequences of which on cladding integrity and H 2 generation should be explored in future works.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Evaluation of an aSi-EPID with flattening filter free beams: Applicability to the GLAaS algorithm for portal dosimetry and first experience for pretreatment QA of RapidArc

Purpose: To demonstrate the feasibility of portal dosimetry with an amorphous silicon mega voltage imager for flattening filter free (FFF) photon beams by means of the GLAaS methodology and to validate it for pretreatment quality assurance of volumetric modulated arc therapy (RapidArc).Methods: The GLAaS algorithm, developed for flattened beams, was applied to FFF beams of nominal energy of 6 and 10 MV generated by a Varian TrueBeam (TB). The amorphous silicon electronic portal imager [named mega voltage imager (MVI) on TB] was used to generate integrated images that were converted into matrices of absorbed dose to water. To enable GLAaS use under the increased dose-per-pulse and dose-rate conditions of the FFF beams, new operational source-detector-distance (SDD) was identified to solve detector saturation issues. Empirical corrections were defined to account for the shape of the profiles of the FFF beams to expand the original methodology of beam profile and arm backscattering correction. GLAaS for FFF beams was validated on pretreatment verification of RapidArc plans for three different TB linacs. In addition, the first pretreatment results from clinical experience on 74 arcs were reported in terms of γ analysis.Results: MVI saturates at 100 cm SDD for FFF beams but this can be avoided if images are acquired at 150 cm for all nominal dose rates of FFF beams. Rotational stability of the gantry-imager system was tested and resulted in a minimal apparent imager displacement during rotation of 0.2 ± 0.2 mm at SDD = 150 cm. The accuracy of this approach was tested with three different Varian TrueBeam linacs from different institutes. Data were stratified per energy and machine and showed no dependence with beam quality and MLC model. The results from clinical pretreatment quality assurance, provided a gamma agreement index (GAI) in the field area for six and ten FFF beams of (99.8 ± 0.3)% and (99.5 ± 0.6)% with distance to agreement and dose difference criteria set to 3 mm/3% with 2 mm/2% thresholds, GAI resulted (95.7.0 ± 2.3)% and (97.2 ± 2.1)%.Conclusions: The GLAaS methodology, introduced in clinical practice for conventional flattened photon beams for machine, IMRT, and RapidArc quality assurance, was successfully adapted for FFF beams of Varian TrueBeam Linac. The detector saturation effects could be eliminated if the portal images acquired at 150 cm for all nominal dose rates of FFF beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Next Generation Nuclear Plant Phenomena Identification and Ranking Tables (PIRTs) Volume 2: Accident and Thermal Fluids Analysis PIRTs

An accident, thermal fluids, and reactor physics phenomena identification and ranking process was conducted by a panel of experts on the next generation nuclear plant (NGNP) design (consideration given to both pebble-bed and prismatic gas-cooled reactor configurations). Safety-relevant phenomena, importance, and knowledge base were assessed for the following event classes: (1) normal operation (including some reactor physics aspects), (2) general loss of forced circulation (G-LOFC), (3) pressurized loss-of-forced circulation (P-LOFC), (4) depressurized loss-of-forced circulation (D-LOFC), (5) air ingress (following D-LOFC), (6) reactivity transients - including anticipated transients without scram (ATWS), (7) processes coupled via intermediate heat exchanger (IHX) (IHX failure with molten salt), and (8) steam/water ingress. The panel's judgment of the importance ranking of a given phenomenon (or process) was based on the effect it had on one or more figures of merit or evaluation criteria. These included public and worker dose, fuel failure, and primary (and other safety) system integrity. The major phenomena of concern that were identified and categorized as high importance combined with medium to low knowledge follow: (1) core coolant bypass flows (normal operation), (2) power/flux profiles (normal operation), (3) outlet plenum flows (normal operation), (4) reactivity-temperature feedback coefficients for high-plutonium-content cores (normal operation and accidents), (5) fission product release related to the transport of silver (normal operation), (6)emissivity aspects for the vessel and reactor cavity cooling system (G-LOFC), (7) reactor vessel cavity air circulation and heat transfer (G-LOFC), and (8)convection/radiation heating of upper vessel area (P-LOFC).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Utilizing HYSPLIT for Emergency Response Modeling at SRS

At SRS, emergency responders use a variety of tools to detect, track, and mitigate hazardous material releases into the atmosphere. Two models currently used at SRS are Puff-Plume and the Lagrangian Particle Dispersion Model (LPDM), a Gaussian and Lagrangian model, respectively. A decision has been made to replace LPDM with the more widely-supported Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model for evaluating inhalation and ingestion doses following a release. HYSPLIT is designed to compute complex dispersion and deposition simulation To achieve the implementation of HYSPLIT, we have developed a preliminary UI framework that will allow HYSPLIT to be run on ATG computers without the need for active network connections, thus avoiding the loss of capabilities in the event of a network outage during an emergency.

Earley, Ian↗

Code CUGEL: A code to unfold Ge(Li) spectrometer polyenergetic gamma photon experimental distributions

A FORTRAN code was developed for the Univac 1108 digital computer to unfold lithium-drifted germanium semiconductor spectrometers, polyenergetic gamma photon experimental distributions. It was designed to analyze the combination continuous and monoenergetic gamma radiation field of radioisotope volumetric sources. The code generates the detector system response matrix function and applies it to monoenergetic spectral components discretely and to the continuum iteratively. It corrects for system drift, source decay, background, and detection efficiency. Results are presented in digital form for differential and integrated photon number and energy distributions, and for exposure dose.

Steyn, J. J.↗

Numerical Modelling of Radionuclide Migration in the Context of a Near-Surface LILW Disposal Facility - 18618

The reference solution for the management of low and intermediate level short-lived waste (LILW) in France consists in their emplacement in concrete vaults built at the near-surface. The corresponding disposal facility under operation by the French waste management organization (Andra), is located in North-eastern France and planned to be closed in 2060. The safety case developed by Andra has to show the evidence that, amongst other aspects, the radionuclide transfer through the confinement barriers will occur in such a way that the human and environmental exposure will be as low as reasonably achievable (ALARA) and in accordance with the dose constraints. For this purpose, modelling is used to integrate uncertainties about the characteristics of concrete components, waste and water table and their evolution in time and space. At last, modelling is finally used to investigate the radiological impact of specific scenarios in which the failure of safety barriers occurs. In the frame of its technical review of the safety assessment, the French Institute for Radiological Protection and Nuclear Safety (IRSN) also performs such kind of numerical modelling of radionuclide fate from the waste to the hydrogeological outlets, in order to check whether the assessment performed by Andra takes into account sufficiently conservative assumptions. The present work aims to evaluate the role of components of the vaults on radionuclide transport during the post-closure period over a few thousand years. For this purpose, IRSN carries out numerical calculations with MELODIE software, which simulates water flow and transport of species, in order to simulate radionuclide migration from waste packages emplaced in a concrete vault to the surrounding groundwater. The developed transport model focuses on 3-H radionuclide and integrates Andra's main assumptions (release model from the waste packages, chemical and hydraulic properties of the vault components, shrinkage and cracks in concrete components). An adaptive mesh method, based on an a posteriori error estimator, was used to model the cracks and the consideration of a strong heterogeneity in the hydraulic and transport parameters values in the different components of the model. This method shows an improvement of results of about 40 times, whereas the mesh size was increased by only 2%. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integration of Models for the Hanford Integrated Disposal Facility Performance Assessment - 18541

The Department of Energy Office of River Protection and its contractors have performed a performance assessment for the near-surface disposal of low-level and mixed low-level waste at the Hanford Integrated Disposal Facility. The long-term performance of the Hanford Integrated Disposal Facility to be protective of human health and the environment was evaluated under the requirements of United States Department of Energy Order 435.1, Radioactive Waste Management. Computer simulations were performed to evaluate whether or not the disposal facility would comply with the performance objectives specified in the order. The evaluation was performed using numerical models to simulate source term releases from vitrified and cement-based waste forms. Source term releases were subsequently transported through the facility into the natural system beneath the facility (comprised of an 85-meter thick vadose zone and thinner but highly conductive saturated zone overlying basalt) to a point of compliance 100-meters downstream from the disposed waste. Due to the differing scales in the finite difference models developed for the source terms and those developed for the natural system, numerical models for source term release and natural system flow and transport were not directly coupled. Instead, the output from the source term simulations were used as input to the natural system flow and transport simulations. The decoupling of the modeled systems makes it difficult to explore synergies and investigate the impact of parameter uncertainties. In order to explore system synergies and evaluate parameter uncertainty, an integrated system model was developed that includes source term release models, natural system transport models, and dose calculations. This paper will describe how the numerical models were used to develop abstractions that could be incorporated into the integrated system level model that was then used to explore system synergies and parameter uncertainties. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Second Target Station Target Removal Dose Rates

The Second Target Station (STS) project at Oak Ridge National Laboratory’s spallation neutron source is a crucial initiative for maintaining U.S. leadership in neutron sciences. The STS aims to create the world’s brightest pulsed cold neutron source, enabling cutting-edge research across various scientific disciplines. To ensure safe and efficient maintenance operations, understanding the effects of shutdown dose rates from activated components within the STS target systems is essential. This study establishes a computational framework for calculating decay gamma sources and subsequent shutdown dose rates utilizing advanced methods to account for all activation channels, including high-energy interactions down to thermal neutron capture. This study describes a novel integration of multiple tools and provides an effective means of analyzing activation and shutdown dose rates at spallation neutron facilities. A custom-developed script automates the decay gamma source generation process, ensuring proper sampling during the variance reduction phase, which is critical for accurate predictions of shutdown dose rates.

Transmutation↗

Performance and Stability of HyBRID Process - 19115

The HyBRID (Hydrazine Base Reductive metal Ion Decontamination) process shows good decontamination performance on radioactively contaminated specimens gathered from Hanul nuclear power plant and from the HANARO research reactor. The effect of γ-ray irradiation on the decomposition of decontamination solution is investigated. In an oxidation step, KMnO{sub 4} decomposes entirely when the absorbed dose exceeds 20 KGy. The addition of Cu{sup 2+} ion to SP retards slightly the decomposition of KMnO{sub 4}. Less than 20 % of hydrazine in the HyBRID solution, however, decomposes at 20 KGy. To treat the secondary waste generated from the HyBRID process by filtration, it is necessary to demonstrate the integrity of polypropylene filters by γ-ray irradiation. The absorbed dose is in the range of 0 KGy to 80 KGy. The variation of tensile strength and the variation of surface morphology of the irradiated PP filters are investigated. The mechanical test results show that the filters can be used safely in the test range. Hydrazine is decomposed into nitrogen and water by hydrogen peroxide. Tests on the decomposition of hydrazine by a hydrogen peroxide solution are carried out by varying the solution pH in the temperature range between 50 deg. C and 70 deg. C. The decomposition of hydrazine becomes effective as the increase of pH and the repetitive injections of hydrogen peroxide, and hydrazine is satisfactorily decomposed. The effect of copper ion on the decomposition of hydrazine is negligible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗