Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INDEXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

SU-E-T-315: Dosimetric Effects of Couch Top Shift On VMAT Delivery in Absence of Indexing

Purpose: To investigate dosimetric effects of couch top shift for volumetric-modulated arc therapy (VMAT) in absence of indexing of immobilization devices. Methods: A total of twelve VMAT treatment plans were selected from three regions (lung, abdomen, and pelvis) to account for the variation of the patient position relative to the couch top. The treatment plans were generated using the Varian Eclipse system. A pinpoint ionization chamber (PTW TN31014) was placed at the center of 16-cm solid water phantom and the dose was delivered using the Varian TrueBeam STx with BrainLAB ExacTrac couch top. To simulate the day-to-day variation of the patient position relative to couch top, the couch top was laterally shifted up to 50 mm, with an increment of 5 mm from 0 to 20 mm; and of 10 mm afterwards, and the phantom was moved back to 0 cm shift for measurement. The dose was also delivered using a Varian tennis racket grid insert at 0 cm shift to simulate the absence of couch top. The treatment plans were delivered with 6, 10, and 15 MV photons using the same leaf sequencing to investigate the energy dependence of couch top shift. The dose difference was normalized to 0 cm shift for the regular couch top for comparison. Results: The percent difference of dose was found to increase with lateral shift for all energies; however, the average differences were close to 0% and the maximum difference was within 1% along the lateral shifts. The differences with the absence of couch top were 2.2±0.5% (6MV), 1.7±0.3% (10MV), and 1.6±0.2% (15MV), respectively. Conclusion: The inclusion of couch top is recommended in treatment planning to minimize the dosimetric uncertainty between calculated and delivered dose even in absence of indexing of immobilization devices in VMAT delivery.

60 APPLIED LIFE SCIENCES↗

Sensitivity of the diagnostic radiological index of protection to procedural factors in fluoroscopy

Purpose: To evaluate the sensitivity of the diagnostic radiological index of protection (DRIP), used to quantify the protective value of radioprotective garments, to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams to be used in measuring the DRIP. Methods: Monte Carlo simulations were performed to determine the shape of the scattered x-ray spectra incident on the operator in different clinical fluoroscopy scenarios, including interventional radiology and interventional cardiology (IC). Two clinical simulations studied the sensitivity of the scattered spectrum to gantry angle and patient size, while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial simulations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size, and beam quality for constant technical factors. Average energy (E{sub avg}) was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affect the scattered spectrum indirectly through their effect on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in IC, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusions: The scattered spectrum striking the operator in fluoroscopy is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle.

60 APPLIED LIFE SCIENCES↗

SU-D-209-05: Sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to Procedural Factors in Fluoroscopy

Purpose: To evaluate the sensitivity of the Diagnostic Radiological Index of Protection (DRIP) to procedural factors in fluoroscopy in an effort to determine an appropriate set of scatter-mimicking primary beams (SMPB) to be used in measuring the DRIP. Methods: A series of clinical and factorial Monte Carlo simulations were conducted to determine the shape of the scattered X-ray spectra incident on the operator in different clinical fluoroscopy scenarios. Two clinical evaluations studied the sensitivity of the scattered spectrum to gantry angle and patient size while technical factors were varied according to measured automatic dose rate control (ADRC) data. Factorial evaluations studied the sensitivity of the scattered spectrum to gantry angle, field of view, patient size and beam quality for constant technical factors. Average energy was the figure of merit used to condense fluence in each energy bin to a single numerical index. Results: Beam quality had the strongest influence on the scattered spectrum in fluoroscopy. Many procedural factors affected the scattered spectrum indirectly through their effects on primary beam quality through ADRC, e.g., gantry angle and patient size. Lateral C-arm rotation, common in interventional cardiology, increased the energy of the scattered spectrum, regardless of the direction of rotation. The effect of patient size on scattered radiation depended on ADRC characteristics, patient size, and procedure type. Conclusion: The scattered spectrum striking the operator in fluoroscopy, and therefore the DRIP, is most strongly influenced by primary beam quality, particularly kV. Use cases for protective garments should be classified by typical procedural primary beam qualities, which are governed by the ADRC according to the impacts of patient size, anatomical location, and gantry angle. These results will help determine an appropriate set of SMPB to be used for measuring the DRIP.

60 APPLIED LIFE SCIENCES↗

Adsorption of oxygen on low-index surfaces of the TiAl{sub 3} alloy

Method of the projector augmented waves in the plane-wave basis within the generalized-gradient approximation for the exchange-correlation functional has been used to study oxygen adsorption on (001), (100), and (110) low-index surfaces of the TiAl{sub 3} alloy. It has been established that the sites that are most energetically preferred for the adsorption of oxygen are hollow (H) positions on the (001) surface and bridge (B) positions on the (110) and (100) surfaces. Structural and electronic factors that define their energy preference have been discussed. Changes in the atomic and electronic structure of subsurface layers that occur as the oxygen concentration increases to three monolayers have been analyzed. It has been shown that the formation of chemical bonds of oxygen with both components of the alloy leads to the appearance of states that are split-off from the bottoms of their valence bands, which is accompanied by the formation of a forbidden gap at the Fermi level and by a weakening of the Ti–Al metallic bonds in the alloy. On the Al-terminated (001) and (110) surfaces, the oxidation of aluminum dominates over that of titanium. On the whole, the binding energy of oxygen on the low-index surfaces with a mixed termination is higher than that at the aluminum-terminated surface. The calculation of the diffusion of oxygen in the TiAl{sub 3} alloy has shown that the lowest barriers correspond to the diffusion between tetrahedral positions in the (001) plane; the diffusion of oxygen in the [001] direction occurs through octahedral and tetrahedral positions. An increase in the concentration of aluminum in the alloy favors a reduction in the height of the energy barriers as compared to the corresponding barriers in the γ-TiAl alloy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Streaming Data Reorganization at Scale with DeltaFS Indexed Massive Directories

We report complex storage stacks providing data compression, indexing, and analytics help leverage the massive amounts of data generated today to derive insights. It is challenging to perform this computation, however, while fully utilizing the underlying storage media. This is because, while storage servers with large core counts are widely available, single-core performance and memory bandwidth per core grow slower than the core count per die. Computational storage offers a promising solution to this problem by utilizing dedicated compute resources along the storage processing path. We present DeltaFS Indexed Massive Directories (IMDs), a new approach to computational storage. DeltaFS IMDs harvest available (i.e., not dedicated) compute, memory, and network resources on the compute nodes of an application to perform computation on data. We demonstrate the efficiency of DeltaFS IMDs by using them to dynamically reorganize the output of a real-world simulation application across 131,072 CPU cores. DeltaFS IMDs speed up reads by 1,740x while only slightly slowing down the writing of data during simulation I/O for in situ data processing.

97 MATHEMATICS AND COMPUTING↗

Application of the Chloride Susceptibility Index to Study the Effects of Ni, Cr, Mn and Mo on the Repassivation of Stainless Steels

The effects of Ni, Cr, Mn and Mo on the very earliest stages of repassivation of stainless steels are quantified using the Chloride Susceptibility Index (CSI), which is an ab initio-based index for the evaluation of repassivation tendency. The quinary system of Fe-Ni-Cr-Mn-Mo is studied with density functional theory analysis and an electrochemisorption model developed previously by the authors, which are required to determine the CSI. The adsorption energies of O and Cl to different surface configurations are calculated, and then surface coverage maps of different species on the surface are obtained from the adsorption energies based on the Langmuir isotherm. Finally, CSI is calculated for different compositions of stainless steels. It is found that the effect of alloying elements on promoting repassivation of Fe alloys is in the order of Mn > ≈Ni > Cr > Mo when solute composition is less than 28 wt.%. A strong synergy is found between Cr and Mo such that a combination of these two elements at a certain ratio can give an optimal (low) CSI. Here, the usage of CSI for evaluating repassivation tendency of CRAs is validated by experimental measured repassivation potential, which shows a strong monotonic negative relation with CSI.

36 MATERIALS SCIENCE↗

OpenStudio® Energy Rating Index (ERI) Workflow (SWR-18-72)

The OpenStudio®-ERI project allows calculating an Energy Rating Index (ERI) using the Department of Energy's open-source OpenStudio®/EnergyPlus® simulation platform. The building description is provided in an HPXML file format. The project supports: - ANSI/RESNET/ICC 301© Standard for the Calculation and Labeling of the Energy Performance of Dwelling and Sleeping Units using an Energy Rating Index - ENERGY STAR Certification System for Homes and Apartments Using an ERI Compliance Path - IECC ERI Compliance Alternative (Section R406) - DOE ZERH Certification Using an ERI Compliance Path For more information on running simulations, generating HPXML files, etc., please visit the documentation at https://openstudio-eri.readthedocs.io/en/latest/

Horowitz, Scott↗

OpenStudio®-ERI (Energy Rating Index (ERI) Workflow) [SWR-18-72] 1.7.0 Released 12/14/2023

The OpenStudio®-ERI project allows calculating an Energy Rating Index (ERI) using the Department of Energy's open-source OpenStudio®/EnergyPlus® simulation platform. The building description is provided in an HPXML file format. The project supports: - ANSI/RESNET/ICC 301© Standard for the Calculation and Labeling of the Energy Performance of Dwelling and Sleeping Units using an Energy Rating Index - ENERGY STAR Certification System for Homes and Apartments Using an ERI Compliance Path - IECC ERI Compliance Alternative (Section R406) - DOE ZERH Certification Using an ERI Compliance Path For more information on running simulations, generating HPXML files, etc., please visit the documentation at https://openstudio-eri.readthedocs.io/en/latest/

Horowitz, Scott↗

Psychological Distress and Alzheimer’s Disease Mortality in the United States: Results from the 1997–2014 National Health Interview Survey-National Death Index Record Linkage Study

Objective: This study examines the association between psychological distress and Alzheimer’s disease mortality among US adults aged ≥45. Methods: We analyzed the Kessler 6-item psychological distress scale as a risk factor for Alzheimer’s mortality using the pooled 1997–2014 National Health Interview Survey (NHIS)- National Death Index (NDI) database ( N = 265,089). Cox regression was used to model mortality as a function of psychological distress and sociodemographic and behavioral covariates. Results: The Alzheimer’s mortality risk was 97% higher (HR = 1.97; 95% confidence interval [CI] = 1.37, 2.84) in adults with serious psychological distress compared with those without psychological distress, controlling for sociodemographic covariates. The relative mortality risk remained statistically significant (HR = 1.49; 95% CI = 1.04, 2.13) after additional adjustment for smoking, alcohol consumption, health status, activity limitation, and body mass index. Discussion: US adults had significantly higher risks of Alzheimer’s disease mortality at higher psychological distress levels. These findings underscore the significance of addressing psychological well-being as a strategy for reducing Alzheimer’s disease mortality.

Singh, Gopal K.↗

Development of the Contamination Distribution Centered Toxics Mobility Vulnerability Index in the Beaumont–Port Arthur Region of Texas

This study advances the Toxics Mobility Inventory (TMI) and the Toxics Mobility Vulnerability Index (TMVI) to develop a new tool to assess the movement of hazardous substances and their implications for vulnerable communities. It emphasizes the need to include contamination distribution variables in such indices to address disproportionate impacts and more accurately reflect vulnerability. The study uses the TMI framework and TMVI methodology in the Beaumont–Port Arthur region of Texas, also integrating contamination distribution considerations into the analysis to develop a new framework and process. The new Contamination Distribution Centered Toxics Mobility Vulnerability Index (CDC-TMVI) consolidates climate change and topography variables into a broader built environment vulnerability category while introducing a contamination sources category. Using ArcGIS Pro and ToxPi tools, the study evaluates 27 geospatial variables across four categories: built environment vulnerability, social vulnerability, health outcomes, and contamination sources. The results indicate significant contributions from contamination and social vulnerability variables, highlighting areas with higher risks of flooding and air pollution. This article advocates for future research and policy efforts to enhance the integration of contamination sources and their spatial distributions into toxics mobility assessments to better protect vulnerable populations. Furthermore, the unique methodology and findings serve as a basis for developing targeted measures and strategic planning to improve environmental health.

contamination↗

Application of artificial intelligence methods in the international roughness index prediction of rigid and composite pavements: a systematic review

The International Roughness Index (IRI) is a widely adopted metric for quantifying pavement roughness, directly influencing vehicle safety, ride comfort, and overall roadway performance. In recent years, the use of Machine Learning (ML) models for IRI prediction has gained momentum, with the goal of improving the allocation of maintenance and rehabilitation resources by enabling accurate assessments of pavement conditions. Most prior reviews, however, have concentrated on flexible pavements, leaving a notable gap regarding rigid and composite pavements. To address this gap, the present study conducts a systematic review of Artificial Intelligence (AI) methods applied to IRI prediction for rigid and composite pavements. Literature published between 2004 and 2025 is synthesized to highlight prevailing trends, methodological contributions, and directions for future research. Particular attention is given to the types of models employed, the datasets used for training and validation, and the role of input variables and data-processing strategies. Across the included studies, ensemble learning methods (especially gradient boosting variants such as XGBoost), artificial neural networks, and hybrid architectures frequently achieved high predictive skill, with several models reporting test-set coefficients of determination approaching 0.9–0.96, indicating strong potential for capturing the influence of traffic, pavement structure, and climatic factors. Since these results are obtained from heterogeneous datasets and evaluation protocols, they are interpreted qualitatively rather than as strict cross-study rankings. Analysis of input variables revealed that pavement age and initial IRI were included in 91% (21 of 23) and 78% (18 of 23) of studies, respectively. Climatic variables such as the freezing index appeared in 57% (13 of 23), while traffic-related factors were considered in 65% (15 of 23). The findings underscore the importance of standardized, high-quality datasets, such as those from the Long-Term Pavement Performance (LTPP) program, along with data consistency, model interpretability, computational efficiency, and replicability in enhancing IRI prediction. Future research should focus on incorporating input variable selection techniques to identify the most influential predictors, thereby improving accuracy and robustness. Integrating these approaches with advanced non-linear data-driven models, coupled with robust hyperparameter optimization, holds considerable promise for strengthening the reliability of IRI prediction and supporting resilient pavement management strategies.

42 ENGINEERING↗

Single-pulse interference caused by temporal reflection at moving refractive-index boundaries

Here, we show numerically and analytically that temporal reflections from a moving refractive-index boundary act as an analog of Lloyd’s mirror, allowing a single pulse to produce interference fringes in time as it propagates inside a dispersive medium. This interference can be viewed as the pulse interfering with a virtual pulse that is identical to the first, except for a π-phase shift. Furthermore, if a second moving refractive-index boundary is added to create the analog of an optical waveguide, a single pulse can be self-imaged or made to produce two or more pulses by adjusting the propagation length in a process similar to the Talbot effect.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-shot measurement of the nonlinear refractive index of air at 92 µm with a picosecond terawatt CO 2 laser

We developed a simple, accurate single-shot method to determine the nonlinear refractive index of air by measuring the evolution of the spatial shape of a laser beam propagating through the atmosphere. A distinctive feature of this new method, which relies on a modified Fresnel propagation model for data analysis, is the use of a hard aperture for producing a welldefined, high-quality beam from a comparatively nonuniform quasi-flat-top beam which is typical for highpeak-power lasers. The nonlinear refractive index of air for a very short (2 ps) long-wave infrared (LWIR) laser pulse was measured for the first time, yielding n 2 = 3.0 × 10 -23 m 2 /W at 9.2 µm. This result is 40% lower than a corresponding measurement with longer (200 ps) LWIR pulses at a similar wavelength.

43 PARTICLE ACCELERATORS↗

Dual-mode fiber-optic refractive-index gas thermometry with primary anchoring and continuous temperature tracking

Extending fiber-optic refractive-index gas thermometry beyond primary-only operation, we report a dual-mode argon-filled Fabry-Perot thermometer in which the same cavity first establishes a primary temperature anchor and then performs continuous secondary-mode tracking. The primary anchor is obtained from two-pressure fringe shifts using a virial-coefficient refractivity model. During secondary operation, pressure cycling is stopped, and temperature is recovered from the monitored fringe wavelength and gas pressure using a model that includes argon refractivity, pressure-induced cavity strain, and fused-silica thermal expansion. From 310 to 1013 K, secondary-mode temperatures agreed with a reference thermocouple with 0.21 K RMSE and 0.47 K maximum error; 45-min natural furnace cooldowns were also tracked from nearby anchors with close agreement. The dual-mode method retains the empirical-calibration-free primary measurement as an in-situ reference while enabling simpler continuous tracking between anchors, addressing a practical limitation of primary-only fiberoptic refractive-index gas thermometry for hightemperature applications.

Syed, Musaddeque [Michigan State University, East ↗

Optically anisotropic porous silicon microlenses with tunable refractive indexes and birefringence profiles

The effect of spatially varying birefringence on the focusing behavior of porous silicon (PSi) and porous silicon dioxide (PSiO 2 ) gradient refractive index (GRIN) lenses is investigated. Both materials attain broad, tunable refractive indexes and birefringence profiles, with PSi having a maximum birefringence of ~0.26 and PSiO 2 a reduced maximum birefringence of ~0.03 at 633 nm. These GRIN lenses exhibit polarization-dependent split focusing behavior, wherein the divergence angle between the twin foci increases with the birefringence gradient. PSi’s large birefringence allows the divergence angle to be tuned such that light focuses away from the center of the lens. These GRIN elements demonstrate how tunable birefringent materials can be used to engineer polarization-selective optical responses.

36 MATERIALS SCIENCE↗

Real-time structural motif searching in proteins using an inverted index strategy

Biochemical and biological functions of proteins are the product of both the overall fold of the polypeptide chain, and, typically, structural motifs made up of smaller numbers of amino acids constituting a catalytic center or a binding site that may be remote from one another in amino acid sequence. Detection of such structural motifs can provide valuable insights into the function(s) of previously uncharacterized proteins. Technically, this remains an extremely challenging problem because of the size of the Protein Data Bank (PDB) archive. Existing methods depend on a clustering by sequence similarity and can be computationally slow. We have developed a new approach that uses an inverted index strategy capable of analyzing >170,000 PDB structures with unmatched speed. The efficiency of the inverted index method depends critically on identifying the small number of structures containing the query motif and ignoring most of the structures that are irrelevant. Our approach (implemented at motif.rcsb.org ) enables real-time retrieval and superposition of structural motifs, either extracted from a reference structure or uploaded by the user. Herein, we describe the method and present five case studies that exemplify its efficacy and speed for analyzing 3D structures of both proteins and nucleic acids.

59 BASIC BIOLOGICAL SCIENCES↗

Fabrication-conscious neural network based inverse design of single-material variable-index multilayer films

Multilayer films with continuously varying indices for each layer have attracted great deal of attention due to their superior optical, mechanical, and thermal properties. However, difficulties in fabrication have limited their application and study in scientific literature compared to multilayer films with fixed index layers. In this work we propose a neural network based inverse design technique enabled by a differentiable analytical solver for realistic design and fabrication of single material variable-index multilayer films. This approach generates multilayer films with excellent performance under ideal conditions. We furthermore address the issue of how to translate these ideal designs into practical useful devices which will naturally suffer from growth imperfections. By integrating simulated systematic and random errors just as a deposition tool would into the optimization process, we demonstrated that the same neural network that produced the ideal device can be retrained to produce designs compensating for systematic deposition errors. Furthermore, the proposed approach corrects for systematic errors even in the presence of random fabrication imperfections. The results outlined in this paper provide a practical and experimentally viable approach for the design of single material multilayer film stacks for an extremely wide variety of practical applications with high performance.

36 MATERIALS SCIENCE↗

Index tests for geosynthetic clay liners containing bentonite–polymer composites

The hydraulic conductivity of geosynthetic clay liners (GCLs) containing bentonite–polymer composites (BPCs) is controlled by a pore clogging mechanism related to the swelling of sodium bentonite (NaB) granules and formation of polymer gel in the pore space. Three index testing procedures that are influenced by bentonite swelling and rheology of the polymer gel were evaluated in this study for screening BPC GCLs for hydraulic conductivity: viscosity, liquid limit by fall-cone penetration and active water content. Experiments were conducted using polyacrylamide (PAM) polymer, dry-blended mixtures of PAM and NaB and a BPC from a commercially available GCL. These materials were contacted with inorganic solutions representing leachates from a range of waste containment scenarios. For the BPC that was evaluated, hydraulic conductivities less than 10 -10 m/s were obtained when the viscosity exceeded 220 mPa s and the active water content exceeded 300%. Hydraulic conductivities less than 10 -11 m/s were achieved for viscosity exceeding 350 mPa s, fall-cone liquid limit exceeding 190 and active water content exceeding 300%. Additional testing is needed to assess the generality of these index tests and the identified thresholds when applied to other BPC GCLs and other permeant liquids.

Engineering↗