Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPACT LOAD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Dust-planetary boundary layer interactions amplified by entrainment and advections

Mineral dust contributes to more than half of the global aerosol loading. However, the radiative impacts of dust aerosols on planetary boundary layer (PBL) structure have not been explored sufficiently. During a typical dust storm event over Tarim Basin, dust aerosols exhibit a well-mixed distribution during the daytime in spite of a shallow layer of dust particles accumulated at higher altitudes. By contrast, nocturnal dust plumes are located near the surface due to stable stratification. We demonstrate that these differentiated vertical distributions determine the spatial heterogeneity of dust loading, radiative fluxes and PBL height variations. Dust aerosols cause daytime PBL suppression and nighttime PBL promotion through modulating surface and atmospheric radiative budgets. Specifically, dust-induced cooling effect within PBL directly inhibits the daytime PBL development. PBL suppression effect is then amplified by entrainment processes resulting in excessively low PBL height, especially for dust particles below but near the PBL top. Dust plumes weaken updrafts from PBL and downdrafts of the free atmosphere, which further reduce the entrainment mixing through attenuating horizontal and vertical advection, and eventually amplify PBL suppression. At night, near-surface dust aerosols stimulate a warm and unstable lower atmosphere, generate warm advection heating and promote the PBL development. Our study highlights the importance of specifying entrainment parameters and nighttime advection activities in quantifying the dust-PBL interactions.

54 ENVIRONMENTAL SCIENCES↗

Predicting impacts of chemicals from organisms to ecosystem service delivery: A case study of endocrine disruptor effects on trout

We demonstrate how mechanistic modeling can be used to predict whether and how biological responses to chemicals at (sub)organismal levels in model species (i.e., what we typically measure) translate into impacts on ecosystem service delivery (i.e., what we care about). We consider a hypothetical case study of two species of trout, brown trout (Salmo trutta; BT) and greenback cutthroat trout (Oncorhynchus clarkii stomias; GCT). These hypothetical populations live in a high-altitude river system and are exposed to human-derived estrogen (17α-ethinyl estradiol, EE2), which is the bioactive estrogen in many contraceptives. We use the individual-based model inSTREAM to explore how seasonally varying concentrations of EE2 could influence male spawning and sperm quality. Resulting impacts on trout recruitment and the consequences of such for anglers and for the continued viability of populations of GCT (the state fish of Colorado) are explored. inSTREAM incorporates seasonally varying river flow and temperature, fishing pressure, the influence of EE2 on species-specific demography, and inter-specific competition. The model facilitates quantitative exploration of the relative importance of endocrine disruption and inter-species competition on trout population dynamics. Simulations predicted constant EE2 loading to have more impacts on GCT than BT. However, increasing removal of BT by anglers can enhance the persistence of GCT and offset some of the negative effects of EE2. We demonstrate how models that quantitatively link impacts of chemicals and other stressors on individual survival, growth, and reproduction to consequences for populations and ecosystem service delivery, can be coupled with ecosystem service valuation. The approach facilitates interpretation of toxicity data in an ecological context and gives beneficiaries of ecosystem services a more explicit role in management decisions. Although challenges remain, this type of approach may be particularly helpful for site-specific risk assessments and those in which tradeoffs and synergies among ecosystem services need to be considered.

54 ENVIRONMENTAL SCIENCES↗

Evaluation of Differential Peptide Loading on Tandem Mass Tag-Based Proteomic and Phosphoproteomic Data Quality

Global and phosphoproteome profiling has demonstrated great utility for the analysis of clinical specimens. One major barrier to the broad clinical application of proteomic profiling is the large amount of biological material required, particularly for phosphoproteomics—currently on the order of 25 mg wet tissue weight, depending on tissue type. For hematopoietic cancers such as acute myeloid leukemia (AML), the sample requirement is in excess of 10 million (1E7) peripheral blood mononuclear cells (PBMCs). Throughout the course of a prospective study, this requirement will certainly exceed what is obtainable from many of the individual patients/timepoints. For this reason, we were interested in examining the impact of differential peptide loading across multiplex channels on proteomic data quality. Methods: To achieve this, we tested a range of channel loading amounts (20, 40, 100, 200, and 400 µg of tryptic peptides, or approximately the material obtainable from 5E5, 1E6, 2.5E6, 5E6, and 1E7 AML patient cells) to assess proteome coverage, quantification reproducibility and accuracy in experiments utilizing isobaric tandem mass tag (TMT) labeling. As expected, we found that fewer missing values are observed in TMT channels with higher peptide loading amounts compared to those with lower loading. Moreover, channels with lower loading amounts have greater quantitative variability than channels with higher loading amounts. Statistical analysis of the differences in means among the five loading groups showed that the 20 µg loading group was significantly different from the 400 µg loading group. However, no significant differences were detected among the 40, 100, 200 and 400 µg loading groups. Conclusions: These assessment data demonstrate the practical limits of loading differential quantities of peptides across channels in TMT multiplexes, and provide a basis for designing the optimal clinical proteomics study when specimen quantities are limited.

59 BASIC BIOLOGICAL SCIENCES↗

Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4

The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4, LaFayette, Georgia (CZ4), and Savannah, Georgia (CZ2)

The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Heat Pump Water Heater Ducting Strategies with Encapsulated Attics in Climate Zones 2 and 4, LaFayette, Georgia (CZ4), and Savannah, Georgia (CZ2)

The focus of this study is on the performance of HPWHs with several different duct configurations and their effects on whole building heating, cooling, and moisture loads. A.O. Smith 60 gallon Voltex (PHPT-60) heat pump water heaters (HPWHs) were included at two project sites and ducted to or located within spray foamed encapsulated attics. The effect of ducting a HPWH's air stream does not diminish its efficiency if the ducting does not reduce intake air temperature, which expands HPWH application to confined areas. Exhaust ducts should be insulated to avoid condensation on the exterior, however this imposes a risk of condensation occurring in the duct's interior near the HPWH due to large variation of temperatures between the compressor and the duct and the presence of bulk moisture around the condenser. The HPWH's air conditioning impact on HVAC equipment loads is minimal when the intake and exhaust air streams are connected to a sealed attic and not the living space. A HPWH is not suitable as a replacement dehumidifier in sealed attics as peak moisture loads were observed to only be reduced if the heat pump operated during the morning. It appears that the intake air temperature and humidity was the most dominant variable affecting HPWH performance. Different ducting strategies such as exhaust duct only, intake duct only, and exhaust and intake ducting did not have any effect on HPWH performance.

Building America↗

Bridging the gap between peak and average loads on science networks

Backbone networks are typically overprovisioned in order to support peak loads. Research and education networks (RENs), for example, are often designed to operate at 20–30% of capacity. Thus, Internet2 upgrades its backbone interconnects when the weekly 95th-percentile load is reliably above 30% of link capacity, and analysis of ESnet traffic between major laboratories shows a substantial gap between peak and average utilization. As science data volumes increase exponentially, it is unclear whether this overprovisioning trend can continue into the future. Even if overprovisioning is possible, it may not be the most cost-effective (and desirable) approach going forward. Under the current mode of free access to RENs, traffic at peak load may include both flows that need to be transferred in near-real time–for example, for computation and instrument monitoring and steering–and flows that are less time-critical, for example, archival and storage replication operations. Thus, peak load does not necessarily indicate the capacity that is absolutely required at that moment. We thus examine how data transfers are impacted when the average network load is increased while the network capacity is kept at the current levels. We also classify data transfers into on-demand (time-critical) and best-effort (less time-critical) and study the impact on both classes for different proportions of both the number of on-demand transfers and amount of bandwidth allocated for on-demand transfers. For our study, we use real transfer logs from production GridFTP servers to do simulation-based experiments as well as real experiments on a testbed. We find that when the transfer load is doubled and the network capacity is fixed at the current level, the gap between peak and average throughput decreases by an average of 18% in the simulation experiments and 16% in the testbed experiments, and the average slowdown experienced by the data transfers is under 1.5×. Moreover, when transfers are classified as on-demand or best-effort, on-demand transfers experience almost no slowdown and the mean slowdown experienced by best-effort transfers is under 2× in the simulation experiments and under 1.2× in the testbed experiments.

97 MATHEMATICS AND COMPUTING↗

Concentration-dependent protein loading of extracellular vesicles released by Histoplasma capsulatum after antibody treatment and its modulatory action upon macrophages

Here, diverse pathogenic fungi secrete extracellular vesicles (EV) that contain macromolecules, including virulence factors that can modulate the host immune response. We recently demonstrated that the binding of monoclonal antibodies (mAb) modulates how Histoplasma capsulatum load and releases its extracellular vesicles (EV). In the present paper, we addressed a concentration-dependent impact on the fungus’ EV loading and release with different mAb, as well as the pathophysiological role of these EV during the host-pathogen interaction. We found that the mAbs differentially regulate EV content in concentration-dependent and independent manners. Enzymatic assays demonstrated that laccase activity in EV from H. capsulatum opsonized with 6B7 was reduced, but urease activity was not altered. The uptake of H. capsulatum by macrophages pre-treated with EV, presented an antibody concentration-dependent phenotype. The intracellular killing of yeast cells was potently inhibited in macrophages pre-treated with EV from 7B6 (non-protective) mAb-opsonized H. capsulatum and this inhibition was associated with a decrease in the reactive-oxygen species generated by these macrophages. In summary, our findings show that opsonization quantitatively and qualitatively modifies H. capsulatum EV load and secretion leading to distinct effects on the host’s immune effector mechanisms, supporting the hypothesis that EV sorting and secretion are dynamic mechanisms for a fine-tuned response by fungal cells.

59 BASIC BIOLOGICAL SCIENCES↗

A new woven composite constitutive model validated by shock wave experiments

In this paper, we present results of plate impact simulations of shock compressed woven glass fiber-reinforced plastic (GRP) performed using the Arbitrary Lagrangian–Eulerian three-dimensional finite element code. A hyperelastic large-strain-based empirical Continuum Damage Mechanics (CDM) formulation is employed to describe damage initiation and growth in the shock-compressed GRP. The model parameters calibration scheme utilizes the Velocity Interferometer System for Any Reflector normal particle velocity measurements at the free surface of the GRP target plates. The impact velocity in the experiments ranged from 8.5 to 418 m/s. The finite element model considered planar 0°/90° bidirectional plies with an individual ply thickness of 0.68 mm, stacked to reach a total laminate thickness of 6.8 mm. The anisotropic elastic strains were estimated from the experimentally determined tetragonal symmetry stiffness matrix for the GRP. The strain-based damage model captures several salient features observed in the measured free surface particle wave profiles, including the shock rise time, onset of Elastic—Elastic Cracking, and the shape of the nonlinear portion of the experimental particle velocity profiles. Furthermore, the CDM model predicts the dominant damage mode to be matrix microcracking due to shear and the associated bulk expansion (bulking) under the global compressive loading in the plate impact configuration.

42 ENGINEERING↗

Melter Testing for Technetium Removal Using Goethite Precipitation

During vitrification of low activity waste (LAW) at the Hanford Tank Waste Treatment and Immobilization Plant (WTP), liquid effluents are produced in the primary off-gas treatment system that processes the exhaust gases from the LAW melters. That effluent stream, which contains captured hazardous and radioactive species from the melter exhaust, is then recycled and eventually becomes part of subsequent melter feed batches. Other constituents, such as sulfur and halides, are also recycled in this process and this can impact the LAW glass loadings that are achievable. Thus, breaking the melter recycle loop could have advantages with respect to reducing LAW glass volumes. However, this recycle stream cannot currently be diverted to liquid secondary waste treatment because of the levels of several constituents in the scrub solutions, particularly technetium. Researchers at Pacific Northwest National Laboratory (PNNL) have been investigating a process whereby the technetium could be precipitated from the off-gas recycle stream in the mineral goethite ((Tc, Fe)OOH). It could then be diverted to the high level waste (HLW) stream through the WTP pretreatment facility and the decontaminated liquid stream could be sent to secondary waste treatment. As part of the test program to develop the goethite precipitation process, it is necessary to assess the impacts of including this material in the HLW melter feed and the extent to which the captured technetium is volatilized during HLW vitrification. To support such testing, sufficiently large batches of material were prepared at PNNL using rhenium as a surrogate for technetium. These materials were shipped to the Vitreous State Laboratory (VSL) of the Catholic University of America (CUA) for testing on a DuraMelter 10 (DM10) small-scale joule-heated ceramic melter system. This report describes the testing that was performed with those materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cu-, Co-, and Zn-Based Metal–Organic Framework-Derived Nanoporous Ion Emitters for Picogram Level Analysis of Actinides

Thermal ionization mass spectrometry (TIMS) is often regarded as the preferred technique for trace-level isotopic analysis of actinides owing to its high sensitivity and absence of carry-over effects. However, actinide sample utilization efficiency (SUE) is typically low (<0.05%) without the use of activators or specialized loading approaches which can yield SUEs of >5%. To this effect, we investigate a series of metal–organic framework (MOF)-based nanoporous ion emitters (nano-PIEs) that show enhanced ionization of actinides when used in TIMS loading. We study the impact of physical and chemical properties of MOFs on TIMS SUEs using two families of MOFs that can be synthesized under similar reaction conditions. The structural and chemical properties of these MOFs can be systematically modified one at a time while keeping other features the same. This allows us to strategically investigate their impact on SUEs. The first family of MOFs considered in this study is Zeolitic Imidazole Frameworks (ZIFs) which are made using 2 methyl-imidazole as an organic linker with zinc (ZIF-8) and cobalt (ZIF-67) as metal centers. Additionally, the effect of morphology was also studied using Zn-based ZIF-L with a 2-dimensional structure. The second family of MOFs was synthesized using benzene-1,3,5-tricarboxylate (BTC) with copper (Cu-BTC) and zinc (Zn-BTC) as the metal center. Among the MOFs tested, Cu-BTC showed the highest SUE with an average SUE of 0.27 ± 0.15%, followed closely by Zn-BTC (0.24 ± 0.10%), ZIF-8 (0.17 ± 0.10%), and trailed by the other MOFs. When the MOFs were pyrolyzed in N 2 before loading, an apparent increase in the SUE was observed with ZIF-8 and Cu-BTC showing average SUEs of 0.25 ± 0.08% and 0.34 ± 0.13%, respectively, with the highest measured SUE of 0.53% for pyrolyzed Cu-BTC. In conclusion, this observed increase in SUE by up to an order of magnitude compared to bare filaments demonstrates the efficacy and potential of MOF-derived nano-PIEs for TIMS application.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Socially-aware evaluation framework for transportation

Technological advancements are rapidly changing traffic management in cities. Navigation applications, in particular, have impacted cities in many ways by rerouting traffic. As different routing strategies distribute traffic differently, understanding these disparities across multiple city-relevant dimensions is extremely important for decision-makers. We develop a multi-themed framework called Socially- Aware Evaluation Framework for Transportation (SAEF), which assists in understanding how traffic routing and the resultant dynamics affect cities. The framework is presented for four Bay Area cities, for which we compare three routing strategies - user equilibrium travel time, system optimal travel time, and system optimal fuel. The results demonstrate that many neighborhood impacts, such as traffic load on residential streets and around minority schools, degraded with the system-optimal travel time and fuel routing in comparison to the user-equilibrium travel time routing. The findings also show that all routing strategies subject the city's disadvantaged neighborhoods to disproportionate traffic exposure. Our intent with this work is to provide an evaluation framework that enables reflection on the consequences of traffic routing and management strategies, allowing city planners to recognize the trade-offs and potential unintended consequences.

99 GENERAL AND MISCELLANEOUS↗

Charting a Path for Research and Development of Reliability and Resilience in South Asia's Power Sector

The power sector in South Asia faces several trends with the potential to impact its reliability and resilience. Rapidly increasing demand, coupled with an increasing reliance on variable renewable resources and the circular linkages with climate change points to an increasing need to understand the extent of climate impacts on both the electricity load and the electricity generation. These larger shifts are also coupled with opportunities near the grid edge that could have a large impact on system planning and operations, such as electrification of the transport sector, increased reliance on buildings to serve a broader set of loads and be flexible resources for utilities, more efficient use of industrial and agricultural loads, and growth in distributed energy resources such as rooftop solar and batteries. It is critical that as this transformation takes place that expectations for reliability and resilience of the grid continue to increase in the region. The South Asia Group for Energy (SAGE), composed of USAID, the US Department of Energy, and three national laboratories, has been tasked with providing an overview of the research and development resources necessary to understand the upcoming challenges for the power system as it pertains to reliability and resilience. This discussion paper identifies some of the key trends and connections that are important for power sector reliability and resilience and provides a starting point for eliciting feedback from power sector stakeholders about their experiences and needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Well-to-wheels analysis of energy use and greenhouse gas emissions of plug-in hybrid electric vehicles.

Plug-in hybrid electric vehicles (PHEVs) are being developed for mass production by the automotive industry. PHEVs have been touted for their potential to reduce the US transportation sector's dependence on petroleum and cut greenhouse gas (GHG) emissions by (1) using off-peak excess electric generation capacity and (2) increasing vehicles energy efficiency. A well-to-wheels (WTW) analysis - which examines energy use and emissions from primary energy source through vehicle operation - can help researchers better understand the impact of the upstream mix of electricity generation technologies for PHEV recharging, as well as the powertrain technology and fuel sources for PHEVs. For the WTW analysis, Argonne National Laboratory researchers used the Greenhouse gases, Regulated Emissions, and Energy use in Transportation (GREET) model developed by Argonne to compare the WTW energy use and GHG emissions associated with various transportation technologies to those associated with PHEVs. Argonne researchers estimated the fuel economy and electricity use of PHEVs and alternative fuel/vehicle systems by using the Powertrain System Analysis Toolkit (PSAT) model. They examined two PHEV designs: the power-split configuration and the series configuration. The first is a parallel hybrid configuration in which the engine and the electric motor are connected to a single mechanical transmission that incorporates a power-split device that allows for parallel power paths - mechanical and electrical - from the engine to the wheels, allowing the engine and the electric motor to share the power during acceleration. In the second configuration, the engine powers a generator, which charges a battery that is used by the electric motor to propel the vehicle; thus, the engine never directly powers the vehicle's transmission. The power-split configuration was adopted for PHEVs with a 10- and 20-mile electric range because they require frequent use of the engine for acceleration and to provide energy when the battery is depleted, while the series configuration was adopted for PHEVs with a 30- and 40-mile electric range because they rely mostly on electrical power for propulsion. Argonne researchers calculated the equivalent on-road (real-world) fuel economy on the basis of U.S. Environmental Protection Agency miles per gallon (mpg)-based formulas. The reduction in fuel economy attributable to the on-road adjustment formula was capped at 30% for advanced vehicle systems (e.g., PHEVs, fuel cell vehicles [FCVs], hybrid electric vehicles [HEVs], and battery-powered electric vehicles [BEVs]). Simulations for calendar year 2020 with model year 2015 mid-size vehicles were chosen for this analysis to address the implications of PHEVs within a reasonable timeframe after their likely introduction over the next few years. For the WTW analysis, Argonne assumed a PHEV market penetration of 10% by 2020 in order to examine the impact of significant PHEV loading on the utility power sector. Technological improvement with medium uncertainty for each vehicle was also assumed for the analysis. Argonne employed detailed dispatch models to simulate the electric power systems in four major regions of the US: the New England Independent System Operator, the New York Independent System Operator, the State of Illinois, and the Western Electric Coordinating Council. Argonne also evaluated the US average generation mix and renewable generation of electricity for PHEV and BEV recharging scenarios to show the effects of these generation mixes on PHEV WTW results. Argonne's GREET model was designed to examine the WTW energy use and GHG emissions for PHEVs and BEVs, as well as FCVs, regular HEVs, and conventional gasoline internal combustion engine vehicles (ICEVs). WTW results are reported for charge-depleting (CD) operation of PHEVs under different recharging scenarios. The combined WTW results of CD and charge-sustaining (CS) PHEV operations (using the utility factor method) were also examined and reported. According to the utility factor method, the share of vehicle miles traveled during CD operation is 25% for PHEV10 and 51% for PHEV40. Argonne's WTW analysis of PHEVs revealed that the following factors significantly impact the energy use and GHG emissions results for PHEVs and BEVs compared with baseline gasoline vehicle technologies: (1) the regional electricity generation mix for battery recharging and (2) the adjustment of fuel economy and electricity consumption to reflect real-world driving conditions. Although the analysis predicted the marginal electricity generation mixes for major regions in the United States, these mixes should be evaluated as possible scenarios for recharging PHEVs because significant uncertainties are associated with the assumed market penetration for these vehicles. Thus, the reported WTW results for PHEVs should be directly correlated with the underlying generation mix, rather than with the region linked to that mix.

02 PETROLEUM↗

Theoretical investigations of electrical transport properties in CoSb3 skutterudites under hydrostatic loadings

We report that CoSb 3 -based skutterudites have been a benchmark mid-temperature thermoelectric material under intensive experimental and theoretical studies for decades. Doping and filling, to the first order, alter the crystal lattice constant of CoSb 3 in the context of “chemical pressure.” In this work, we employed ab initio density functional theory in conjunction with semiclassical Boltzmann transport theory to investigate the mechanical properties and especially how hydrostatic loadings, i.e., “physical pressure,” impact the electronic band structure, Seebeck coefficient, and power factor of pristine CoSb 3 . It is found that hydrostatic pressure enlarges the band gap, suppresses the density of states (DOS) near the valence band edge, and fosters the band convergence between the valley bands and the conduction band minimum (CBM). By contrast, hydrostatic tensile reduces the band gap, increases the DOS near the valence band edge, and diminishes the valley bands near the CBM. Therefore, applying hydrostatic pressure provides an alternative avenue for achieving band convergence to improve thermoelectric properties of N-type CoSb 3 , which is further supported by our carrier concentration studies. Lastly, these results provide valuable insight into the further improvement of thermoelectric performance of CoSb 3 -based skutterudites via a synergy of physical and chemical pressures.

36 MATERIALS SCIENCE↗

Analysis of thermal and mechanical properties with inventory level of the molten salt storage tank in central receiver concentrating solar power plants

Molten salt thermal energy storage (TES) tanks ensure steady power output of concentrating solar power (CSP) plants; however, recent tank failures have highlighted the need for further analysis. Current studies primarily focus on analyzing the molten salt flow, heat transfer, and thermal efficiency. Additionally, research on the latest tank structures is limited and lacks newest experimental validation. This study measures temperature and molten salt inventory levels in the high-temperature tank at a 50 MW central receiver CSP plant, connected to the power grid in 2019. A multi-physics model was developed to evaluate thermal and mechanical properties of TES tanks by combining computational fluid dynamics and finite element modeling using real plant data. Heat loss, temperature, displacement, and stress distribution of the tank at different inventory levels were investigated. Results show that ambient air velocity near the tank roof reaches 2.14 m/s, much higher than 0.2 m/s near the wall. The temperatures of inventory fluid and tank are close, varying slightly at different levels due to thermal conduction and radiation. Because the heat loss strongly depends on temperature, the total tank loss remains nearly constant across inventory levels. Larger temperature gradients and thermal stresses are primarily localized along the tank floor edge and the air-salt interface. Notably, the maximum thermal stress at the tank edge is three times higher than that at the interface. The magnitude of total stress changes by less than 5 MPa with and without thermal load, indicating that high temperatures exert only a minor impact on tank stress. In contrast, thermal load significantly affects tank deformation, particularly at the roof edge, where values exceed 150 mm. Despite the large variation in molten salt levels, tank wall temperatures and displacements present a minor change, suggesting a weak correlation with inventory levels. In conclusion, the findings obtained in this study provide important insights on the TES tank that could be used to optimize tank design and operation strategies.

14 SOLAR ENERGY↗

Pre-Compressed Targets for Gas Gun Studies

This work developed the capability for pre-compressing targets for Hugoniot measurements utilizing gas gun driven flyer plates. Initial condition control, such as pre-compression, allows access to states off the principal Hugoniot and in the case of highly compressible materials, the locus of shock states may be well off (significantly denser than) the principal Hugoniot even for relatively modest (~100's MPa) initial pressures. The design and operation of the pre-compression target hardware will be discussed in relation to functionality and design considerations for dynamic testing. Capability for loading of super critical gases and gas mixtures has been successfully demonstrated and dynamic hypervelocity impacts of helium were tested. Example loading of supercritical alcohol (ethanol) will is presented in the context of previous impact studies of initially ambient quiescent liquid. Advantages and limitations of the system are discussed in the context accessing highly compressed states.

42 ENGINEERING↗

California Price Response Potential Study

California's energy landscape is undergoing a significant transformation, driven by the increasing integration of renewable energy sources, the increased adoption of distributed energy resources, the electrification of end-use loads, and the growing need for grid efficiency. To address these challenges, recent revisions to the State’s Load Management Standards (LMS) require all of California’s large utilities and community choice aggregators (CCAs) to offer dynamic electricity pricing options to customers by 2027. Dynamic pricing, which involves varying electricity rates based on real-time supply and demand conditions, offers a promising solution for optimizing grid operations, reducing costs, and incentivizing efficient use of grid capacity. Effective implementation of dynamic pricing requires understanding the potential impacts on customer bills, system load, and the cost-effectiveness of automation technologies. This study aims to evaluate the load response of various end-use devices to hourly dynamic prices. The end-uses studied here are space cooling, space heating, water heating, crop irrigation, pool and spa pumps, and electric vehicle (EV) charging, all for both residential and commercial applications, except for crop irrigation. In 2030, these end uses are forecasted to account for 18% of annual electricity demand in the state, but 40% of demand in the peak net load hour. By modeling possible price-responsive load dispatch algorithms and assessing the resulting impacts on both individual bills and the overall grid, we seek to inform policymakers and utilities about the potential benefits and challenges associated with dynamic pricing, and considerations for the design of dynamic pricing tariffs. Additionally, we will explore the cost effectiveness of adopting automation technologies to enable devices to respond more effectively to real-time price signals. This study considers a range of price profiles, accounting for differences across utilities and customer classes, and presents scenarios for dynamic price design via variation in the percentage of total customer electric costs that are allocated dynamically (versus constituting a fixed portion of the hourly volumetric price). We present results focused primarily on 2030, forecasting electricity prices under both low and high-cost scenarios, to inform longer-term tariff design considerations. We design tariffs by starting with 2019 prices that were calculated according to CalFUSE guidance (CPUC, 2022) and that have been used in recent studies; these prices are all-in volumetric rates that vary by utility and are revenue-neutral to each customer class. They are developed by considering six electricity cost components that are allocated hourly based on system load indicators (gross and net load, and wholesale prices). These prices are forecasted to 2030 for low and high cost scenarios, considering recent trends in total electricity costs with and without years of substantial wildfire mitigation investments. These tariffs, which allocate all costs on an hourly basis, are considered our “Full” dynamic tariff design scenario, while two additional scenarios explore allocating a portion of costs as a flat volumetric charge: the “Medium” scenario allocates 50% of revenue dynamically (and keeps 50% flat), while the “Mild” scenario allocates 20% of revenue dynamically. The 20% dynamic allocation on the Mild scenario aims to represent a case where only the marginal operating costs of the grid are included in the dynamic price.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗