Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Impacts of COVID-19 related stay-at-home restrictions on residential electricity use and implications for future grid stability

“Stay-at-home” orders and other health precautions enacted during the COVID-19 pandemic have led to substantial changes in residential electricity usage. Here, we conduct a case study to analyze data from 390 apartments in New York City (NYC) to examine the impacts of two key drivers of residential electricity usage: COVID-19 case-loads and the outdoor temperature. We develop a series of regression models to predict two characteristics of residential electricity usage on weekdays: The average occupied apartment’s consumption (kWh) over a 9am-5pm window and the hourly peak demand (Watt) over a 12pm-5pm window. Via a Monte Carlo simulation, we forecast the two usage characteristics under a possible scenario in which stay-at-home orders in NYC, or a similar metropolitan region, coincide with warm summer weather. Under the scenario, the 9am-5pm residential electricity usage on weekdays is predicted to be 15% – 24% higher than under prior, pre-pandemic conditions. This could lead to substantially higher utility costs for residents. Additionally, we predict that the residential hourly peak demand between 12pm and 5pm on weekdays could be 35% – 53% higher than that under pre-pandemic conditions. We conclude that the projected increase in peak demand - which might arise if stay-at-home guidelines coincided with hot weather conditions - could pose grid management challenges, especially for residential feeders. We also note that, if there is a longer lasting shift towards work and study-from-home, utilities will have to rethink load profile considerations. The applications of our predictive models to managing future smart-grid technology are also highlighted.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demand Response in Bangalore: Implications for Electricity System Operations

Recent Greening the Grid studies for India highlight the benefits of flexible resources for integrating variable renewable energy onto India’s electricity system. India’s ambitious renewable energy targets, which are particularly focused on renewable resource states such as Karnataka, will face fewer challenges when combined with new planning and operational strategies and technologies. This report explores one such strategy - demand response - by which the system operator shifts load throughout a day to minimize system wide production costs. To explore this strategy, we added demand response resources to Karnataka’s electricity system in a production cost model of India, using load shifting potential analyzed by Lawrence Berkeley National Labs. We then investigated the impacts of increasing demand response capacity under several renewable resource scenarios. Our results show the addition of demand response enables fuel shifting from high-marginal-cost and emissions-intensive subcritical coal and diesel generation to zero-marginal-cost and emissions-free renewable generation. Accordingly, the value that demand response provides to the system increases as the renewable penetration increases. In addition to reducing production costs and emissions, demand response reduces the time that thermal generators spend at their minimum output levels, which typically represents a less efficient and costlier operational state. Agricultural load shifting provides greater value to the system than residential, commercial, or industrial loads. Agricultural demand response is more flexible than other sectors because it is not exposed to subdaily operational constraints and it can operate for more hours per day without impacting customer satisfaction. Further, the first increment of demand response that is added to a system provides the greatest value; further additions provide additional benefits but have a decreasing impact. The insights we discuss could be leveraged by system planners and operators in other jurisdictions, particularly those facing significant renewable energy penetrations, to develop their own demand response programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Guide for Improved Resource Adequacy Assessments in Evolving Power Systems: Institutional and Technical Dimensions

This paper identifies and evaluates issues in traditional resource adequacy (RA) assessment practices, and how adjusting these practices may affect and depend on existing institutional arrangements for planning and procurement. The paper proposes a technical-institutional roadmap that would allow regulators in vertically-integrated jurisdictions and system planners and operators in restructured jurisdictions to revise RA practices across a range of components. First, we compile a critical review of current RA assessment practices based on (1) interviews with RA practitioners and (2) a review of recent technical literature. We find that (i) RA may need to expand beyond capacity adequacy to ensure energy adequacy – relevant for energy-limited resources such as storage – and potentially some form of ancillary service adequacy (e.g. enough ramping-up and ramping-down capability in the system); (ii) chronological hourly simulations for all hours in the year are the current best practice; (iii) metrics and models used do not reflect economic criteria in system operation and loss of load; and (iv) there is a need to improve representation of weather dependencies and weather data. Second, we review planning and RA reports for several private and public entities that plan generation and/or transmission infrastructure in the continental U.S. to look for existing practices involving resilience assessments. We find no systematic treatment of the costs of extreme weather and other hazards, the benefits of resilience, and resilience metrics in planning analyses and no systematic treatment of resilience metrics, methods, and outcomes for resource adequacy purposes. Third, we create a technical framework for probabilistic RA assessment and use it to study how key choices about how to model power system operations affect the values that are obtained for RA metrics. We find that (i) non-economic dispatch schemes that ignore economic objectives can lead to accurate RA assessments when coordinated with detailed operational strategies; (ii) multi-year data is critical to capture a wide variety of system conditions; (iii) not incorporating transmission limits into RA assessment could lead to substantial underestimation of traditional “expected value” RA metrics; and (iv) new RA metrics that capture event-specific shortfall characteristics should be used as supplements to traditional metrics. Finally, we examine RA assessments and use this information to propose a guide of evolving industry standards for resource adequacy assessments in resource planning and transmission planning. We report minimum, best, and frontier practices for temporal resolution of assessments, metrics and targets, weather data, load forecasting, characterization of variable renewable resources, characterization of transmission and market transactions, RA modeling and integration with planning processes, and capacity accreditation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Testing of a variable-stroke Stirling engine

Testing of a variable-stroke Stirling engine at NASA Lewis has been completed. In support of the DOE Stirling Engine Highway Vehicle Systems Program, the engine was tested for about 70 hours total with both He and H2 as working fluids over a range of pressures and strokes. A direct comparison was made of part-load efficiencies obtained with variable-stroke (VS) and variable-pressure operation. Two failures with the variable-angle swash-plate drive system limited testing to low power levels. These failures are not thought to be caused by problems inherent with the VS concept but do emphasize the need for careful design in the area of the crossheads.

Thieme, Lanny G.↗

Effect of 3-Day Bed Rest on the Basal Sympathetic Activity and Responsiveness of this System to Physiological Stimuli In Athletes and Sedentary Subjects

The aims of this study were: (1) to examine the effect of three days of bed rest (BR) on basal plasma epinephrine [E] and norepinephrine [NE] and the catecholamine responses to various physiological stimuli, and (2) to find out whether previous physical activity modifies effects of BR. In the first series, 29 young men (11 sedentary students, 8 endurance and 10 strength trained athletes) were submitted to oral glucose tolerance test in supine position and to active orthostatic test before and after 3 days of BR. Plasma [E] and [NE] were measured after overnight fast (basal condition), at 60, 120 and 180 min after glucose ingestion (70 a), and at the 8th min of unsupported standing. In the second series, other 22 subjects (12 sedentary students, 10 endurance and 10 strength trained athletes) were submitted to 2 min cold pressor test (CPT) and exercise. Plasma E and NE were determined in the supine position after overnight fast and at 60th and 120th s of hand cooling. Then, after breakfast followed by 2-3 hour sitting, the subjects performed cycle ergometer exercise with workload increasing until volitional exhaustion. Plasma [E] and [NE] were determined at the end of each load. Plasma catecholamines were determined made radioenzymatically. After BR, basal plasma [NE] was decreased in endurance and strength athletes (p<0.01) but not in sedentary subjects. In neither group BR affected the basal [E]. Responses of both catecholamines to glucose load were diminished after BR in all three groups (p<0.05) but the effect was most pronounced in the endurance athletes. All subjects tolerated well 8-min standing although their heart rate response was increased after BR. Plasma catecholamine responses standing were not significantly affected by BR in either group but the plasma [NE] and [E] during standing were lowered after BR in endurance athletes (p<0.01). BR did not affect blood pressure and catecholamine responses to CPT. The pre- and post-exercise plasma catecholamines were similar before and after BR although the subjects achieved lower maximal loads after BR. In endurance athletes the threshold for plasma NA rise occurred at lower work intensity after than before BR (p<0.05).

Smorawinski, Jerzy↗

Engine Development Design Margins Briefing Charts

New engines experience durability problems after entering service. The most prevalent and costly is the hot section, particularly the high-pressure turbine. The origin of durability problems can be traced back to: 1) the basic aero-mechanical design systems, assumptions, and design margins used by the engine designers, 2) the available materials systems, and 3) to a large extent, aggressive marketing in a highly competitive environment that pushes engine components beyond the demonstrated capability of the basic technology available for the hardware designs. Unfortunately the user must operate the engine in the service environment in order to learn the actual thrust loading and the time at max effort take-off conditions used in service are needed to determine the hot section life. Several hundred thousand hours of operational service will be required before the demonstrated reliability of a fleet of engines or the design deficiencies of the engine hot section parts can be determined. Also, it may take three to four engine shop visits for heavy maintenance on the gas path hardware to establish cost effective build standards. Spare parts drive the oerator's engine maintenance costs but spare parts also makes lots of money for the engine manufacturer during the service life of an engine. Unless competition prevails for follow-on engine buys, there is really no motivation for an OEM to spend internal money to improve parts durability and reduce earnings derived from a lucrative spare parts business. If the hot section life is below design goals or promised values, the OEM migh argue that the engine is being operated beyond its basic design intent. On the other hand, the airframer and the operator will continue to remind the OEM that his engine was selected based on a lot of promises to deliver spec thrust with little impact on engine service life if higher thrust is used intermittently. In the end, a standoff prevails and nothing gets fixed. This briefing will propose ways to hold competing engine manufacturers more accountable for engine hot section design margins during the entire Engine Development process as well as provide tools to assess the design temperature margins in the hot section parts of Service Engines.

Bentz, Chuck↗

Are Soft Short Tests Good Indicators of Internal Li-ion Cell Defects?

The self discharge test at full state of charge, may not be a good one to detect subtle defects since the li-ion chemistry has the highest self discharge at full state of charge. One should characterize self discharge versus storage time for each cell manufacturer/design to differentiate between normal self discharge and that due to a subtle manufacturing defect. The various soft short test methods indicate that if this test is carried out at full discharge (0% SOC) with all capacity removed (by lowering the current load in a stepwise manner to the same end of discharge voltage), then the cells need to be placed in storage for more than 72 hours to get a good analysis on the presence of subtle defects since it takes more than 72 hours to achieve voltage stabilization. If the cells are to be charged up even to a small percentage (ex. 1%), 72 hours are sufficient to determine issues. However, the pass/fail criteria should be based on a valid OCV decline. Less than 10 mV voltage decline is not a good method to detect subtle defects. As mentioned in the first bullet, self discharge is a competing reaction when a charge is introduced and hence a characterization of the self discharge versus storage time is required to fully correlate voltage decline to a failure due to a subtle defect. Soft short test method cannot be relied on for defect detection because cells with and without voltage decline seemed to have similar defects and characteristics. Screening methods such as internal resistance and capacity as well as a 3-sigma range for OCV, mass and dimensions should be used to screen out outliers. A very critical aspect in the understanding of subtle defects is to carry out destructive analysis of cells from every lot to confirm the quality of production and screen all cells and batteries in a stringent manner to have a high quality set of flight cells. Self Discharge Test: Fully charged cells shall be placed in Open circuit stand for 72 hours (OCV measurement twice a day); continue for total of 14 days with 1 reading per day 2. Soft Short Test 1: Fully charge; cells discharged to manufacturer's end of disch. Voltage (EODV) cutoff at C/5 rate; stand for 30 minutes; discharge with C/500 to the same EODV. stand for another 30 minutes; discharge the cells again using C/1000 current to the same EODV. OCV measurements twice a day for 72 hours and then for total of 14 days (data collection same as in 1.) 3. Soft Short Test 2: Fully charge; cells discharged to the manuf. EODV with a C/13 constant current; provide a 10 hour rest, discharge again to the same EODV with a current of C/250, provide a 10 hour rest, discharge again using a C/250 rate, provide a 24 hour rest, charge using C/250 to 3.15 V (for ~12 hours). OCV measurements twice a day for at 72 hours. (data collection same as in 1.) 4. Soft Short Test 3: Fully charge; cells shall be discharged using C/10 current to manuf. EODV. Allow the cell to remain at Open circuit for 10 seconds. Discharge the cell at C/20 rate to the same EODV, hold open circuit for 24 hours. Discharge the cells at C/200 rate to the same end of voltage cutoff and hold open circuit for 24 hours. Discharge the cells one more time at C/200 rate to the same EODV and hold open circuit for 36 hours. Charge at C/200 rate to 3.15 V and hold for 3 days. Record OCV during the open circuit stand periods every 12 hours and at the beginning and end of the 3 day hold (include the 12 hour OCV recording during this time also). Capacity Cycling: Cells with declining voltages - one cell from each manufacturer chosen for cycling Destructive Physical Analysis (DPA): Cells with and without decline chosen from each lot for DPA.

Jeevarajan, J.↗

Analysis of Space Station Centrifuge Rotor Bearing Systems: A Case Study

A team of NASA bearing and lubrication experts was assembled to assess the risk for the rolling-element bearings used in the International Space Station (ISS) centrifuge rotor (CR) to seize or otherwise fail to survive for the required 10-year life. The CR was designed by the Japan Aerospace Exploration Agency and their subcontractor, NEC Toshiba Space Systems, Ltd. (NTSpace). The NASA team performed a design audit for the most critical rolling-element bearing systems and reviewed the lubricant selected. There is uncertainty regarding the ability of the Braycote 601 grease (Castrol Limited) to reliably provide the 10-year continuous life required without relubrication of the system. The fatigue life of the Rotor Shaft Assembly (RSA) spring loaded face-to-face mount at a 99-percent probability of survival (L1 life) for the ball bearing set was estimated at 700 million hours and the single ball bearing (Row 3) at 58 million hours. These lives satisfy the mission requirements for fatigue. Rolling-element seizure tests on the RSA and fluid slip joint bearings were found unlikely to stop the centrifuge, which can cause damage to the ISS structure. The spin motor encoder duplex angular-contact ball bearings have a hard preload and a large number of small balls have the highest risk of failure. These bearings were not tested for seizure even though they are less tolerant to debris or internal clearance reductions.

Poplawski, Joseph V.↗

The Profile Envision and Splice Tool (PRESTO): Developing an Atmospheric Wind Analysis Tool for Space Launch Vehicles Using Python

Tropospheric winds are an important driver of the design and operation of space launch vehicles. Multiple types of weather balloons and Doppler Radar Wind Profiler (DRWP) systems exist at NASA's Kennedy Space Center (KSC), co-located on the United States Air Force's (USAF) Eastern Range (ER) at the Cape Canaveral Air Force Station (CCAFS), that are capable of measuring atmospheric winds. Meteorological data gathered by these instruments are being used in the design of NASA's Space Launch System (SLS) and other space launch vehicles, and will be used during the day-of-launch (DOL) of SLS to aid in loads and trajectory analyses. For the purpose of SLS day-of-launch needs, the balloons have the altitude coverage needed, but take over an hour to reach the maximum altitude and can drift far from the vehicle's path. The DRWPs have the spatial and temporal resolutions needed, but do not provide complete altitude coverage. Therefore, the Natural Environments Branch (EV44) at Marshall Space Flight Center (MSFC) developed the Profile Envision and Splice Tool (PRESTO) to combine balloon profiles and profiles from multiple DRWPs, filter the spliced profile to a common wavelength, and allow the operator to generate output files as well as to visualize the inputs and the spliced profile for SLS DOL operations. PRESTO was developed in Python taking advantage of NumPy and SciPy for the splicing procedure, matplotlib for the visualization, and Tkinter for the execution of the graphical user interface (GUI). This paper describes in detail the Python coding implementation for the splicing, filtering, and visualization methodology used in PRESTO.

Orcutt, John M.↗

Fatigue and fail-safe design features of the DC-10 airplane

The philosophy and methods used in the design of the DC-10 aircraft to assure structural reliability against cracks under repeated service loads are described in detail. The approach consists of three complementary parts: (1) the structure is designed to be fatigue resistant for a crack-free life of 60,000 flight hours; (2) inasmuch as small undetected cracks could develop from other sources, such as material flaws and manufacturing preloads, the structure also is designed to arrest and control cracks within a reasonable service-inspection interval; and (3) a meaningful service-inspection program has been defined on the basis of analysis and test experience from the design development program. This service-inspection program closes the loop to assure the structural integrity of the DC-10 airframe. Selected materials, fasteners, and structural arrangements are used to achieve these design features with minimum structural weight and with economy in manufacturing and maintenance. Extensive analyses and testing were performed to develop and verify the design. The basic design considerations for fatigue-resistant structure are illustrated in terms of material selection, design loads spectra, methods for accurate stress and fatigue damage analysis, and proven concepts for efficient detail design.

Stone, M. E.↗

Amphibian fertilization and development in microgravity

During the year before launch, female frogs will be tested every 3 months for the quantity and quality of eggs produced. Two weeks or more prior to launch, male and female frogs will be transported to the John F. Kennedy Space Center (KSC). During the few weeks before launch, groups will be periodically tested for egg quality to assure that the frogs have adapted to the KSC laboratory environment. About 27 hours before launch, four females will be placed in a damp foam-lined box, called the Adult Frog Box (AFB), through which 100 cc/min of air wil be circulated. The AFB will be lowered into the Spacelab and loaded into the Frog Environmental Unit (FEU) during the final pre-launch preparations. A sperm suspension, for use in flight to fertilize the eggs, will also be prepared and loaded during the pre-launch period. The sperm suspension, together with a kit of syringes containing Human Chorionic Gonadotropin (HCG), will be stored in a refrigerator aboard the shuttle until needed in flight. On the first day of flight, the AFB will be transferred from the FEU to the General Purpose Work Station (GPWS), which is a type of glove box specially designed to allow the crew to use chemicals and biological materials during the flight without contaminating the shuttle/Spacelab environment. Inside the GPWS the four adult frogs will be injected with the HCG hormone and returned to the FEU. Approximately 16 hours after injection, ovulation should have taken place and 15 to 20 eggs from each frog will be placed on each of two egg baskets and covered with sperm for 10 minutes. The egg baskets are inserted into acrylic egg chambers and 50 ml of 'pond water' (20 percent strength Modified Ringers solution (is added. One of the chambers from each frog will be placed on a centrifuge within the FEU and rotated to simulate normal terrestrial gravity (1 g). The remaining chambers are incubated under microgravity conditions within the FEU. Forty minutes after fertilization, the four chambers exposed to 1 g will be removed and observed within the GPWS using a dissecting microscope and camera system. On the basis of egg rotation and egg appearance, the 'best' and 'second best' frogs will be selected to contribute additional eggs. Using the two best frogs, 22 egg chambers will be loaded with eggs and fertilized. Eleven chambers wil be incubated at microgravity and eleven will be incubated on the centrifuge. At various times during the flight, chambers will be removed from the FEU and transferred to the GPWS where a formaldehyde-based fixative will be injected in order to preserve important developmental stages for in depth study following the flight. Five of the 22 chambers plus the eight fertilization test chambers will be returned to Earth with live tadpoles. The swimming behavior of these free swimming tadpoles will be examined within several hours of landing and some will be fixed for a detailed analysis of their inner ear, the otolity, the animals 'balance system.' Lychakov and Vinikov reported an increase in otolith size in tadpoles that developed (but were not fertilized) in space. Live tadpoles from the SL-J flight will be raised through metamorphsis for studies of maturation including an analysis of the effects of space flight on their ability to produce normal progency. Following the flight, the fixed embryos will be serially sectioned and stained using procedures that were developed for this experiment. The embroys fixed at the 2-4 cell stage will be examined for the distribution of cytoplasmic contents, including the various classes of yolk platelets, and the location and shape of the cleavage furrows. The gastrulae will be assessed for the normality of the complex cellular rearrangements that constitute blastopore formation and involution, i.e., the differentiation of the embryo into its specialized body parts. Using a new procedure, the gastrulae will be bleached which will enable the initial sperm entry point (SEP) to be located. The correlation between the SEP and the dorsal lip of the blastopore will be determined. Under normal terrestrial conditions it was shown that the SEP typically is located on the side of the egg opposite the future dorsal side of the embryo. The neurulae will be examined for the normality and completeness of the neural plate and archenteron expansion. The tadpole stages will be used to study the allometry and morphology of the various organ systems.

Souza, Kenneth A.↗

Development of Advanced Fuel Cell System (Phase 4)

A multiple-task research and development program was performed to improve the weight, life, and performance characteristics of hydrogen-oxygen alkaline fuel cells for advanced power systems. During Phase 4, the lowest stabilized degradation rate observed in all the testing completed during four phases of the program, 1 microvolt/hour, was demonstrated. This test continues after 5,000 hours of operation. The cell incorporates a PPf anode, a 90Au/10Pt cathode, a hybrid frame, and a Fybex matrix. These elements were developed under this program to extend cell life. The result demonstrated that the 80Au/20Pt cathode is as stable as a 90Au/10Pt cathode of twice the precious metal loading, was confirmed in full-scale cells. A hybrid frame two-cell plaque with dedicated flow fields and manifolds for all fluids was demonstrated to prevent the cell-to cell electrolyte transfer that limited the endurance of multicell plaques. At the conclusion of Phase 4, more than 90,900 hours of testing had been completed and twelve different cell designs had been evaluated. A technology base has been established which is ready for evaluation at the powerplant level.

Meyer, A. P.↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

The effect of price-based demand response on carbon emissions in European electricity markets: The importance of adequate carbon prices

Price-based demand response (PBDR) has recently been attributed great economic but also environmental potential. However, the determination of its short-term effects on carbon emissions requires the knowledge of marginal emission factors (MEFs), which compared to grid mix emission factors (XEFs), are cumbersome to calculate due to the complex characteristics of national electricity markets. This study, therefore, proposes two merit order-based methods to approximate hourly MEFs and applies them to readily available datasets from 20 European countries for the years 2017–2019. Based on the calculated electricity prices, standardized daily load shifts were simulated which indicated that carbon emissions increased for 8 of the 20 countries and by 2.1% on average. Thus, under specific circumstances, PBDR leads to carbon emissions increases, mainly due to the economic advantage fuel sources such as lignite and coal have in the merit order. MEF-based load shifts reduced the mean resulting carbon emissions by 35%, albeit with 56% lower monetary cost savings compared to price-based load shifts. Finally, by repeating the load shift simulations for different carbon price levels, the impact of the carbon price on the resulting carbon emissions was analyzed. The Spearman correlation coefficient between carbon intensity and marginal cost along the German merit order substantially increased with increasing carbon price. The coefficients were -0.13 for the 2019 carbon price of 24.9 €/t, 0 for 42.6 €/t, and 0.4 for 100.0 €/t. Therefore, with adequate carbon prices, PBDR can be an effective tool for both economical and environmental improvement.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation, construction and endurance testing of compression sealed pyrolytic boron nitride slot insulation

A high-temperature statorette, consisting of an iron-27 percent cobalt magnetic lamination stack and nickel-clad silver conductors, was tested with pyrolytic boron nitride slot insulation. Temperatures were measured in each test to determine characteristics of slot linear heat conductance from statorette conductors. Testing was carried out to temperatures of approximately 1500 F in a vacuum environment of 10-8 torr. Three assemblies were built and tested, each having a different room temperature slot clearance. The final statorette assembly was subjected to a 100-hour vacuum aging test at 1400 F followed by 25 thermal cycles. Temperature data from the three assemblies showed that decreasing slot clearance and increasing compression loading did enhance heat transfer. The temperature difference between slot and lamination at 1400 F increased 4 F during the thermal aging and an additional 10 F during the 25 thermal cycles.

Grant, W. L.↗

ADDJUST-A View of the First 25 Years

Various technologies and innovative launch operations were developed during the 50 years of the Centaur upper stage—the first launch vehicle to use high performing liquid hydrogen fuel. One innovation was “ADDJUST”, which enabled the successful negotiation of upper level winds measured only hours before launch. Initial causes for its creation, development, and operation during countdown are detailed. Problem definition, wind measuring/monitoring process, pitch and yaw steering coefficient generation, loads analysis, angle of attack, major risks/concerns, and anecdotal recollections are provided. Launch availability improved from as low as 55 to 95 percent due to ADDJUST, which is still in use.

Upper level winds↗

Artemis I Countdown 101

Before the Artemis I mission launches on its way around the Moon, the launch team at Kennedy Space Center and supporting teams across the country will begin the launch countdown about two days before liftoff. The launch countdown contains "L Minus” and "T Minus" times. "L minus" indicates how far away we are from liftoff in hours and minutes and does not include built-in holds. “T minus” time is a sequence of events that are built into the launch countdown where counting and holds are inserted. The 730,000 gallons of propellants that will be loaded into the rocket are liquid oxygen (LO2) and liquid hydrogen (LH2). Pauses in the countdown, or "holds," are built into the countdown to allow the launch team to target a precise launch window, and to provide a cushion of time for certain tasks and procedures without impacting the overall schedule. For the Artemis I countdown, planned built-in holds vary in length and occur at the following times: L-8 hours, 40 minutes, and L-40 minutes.

Madison Elizabeth Tuttle↗

Experimental Evidence on Latency in a Fleet of Controllable Water Heaters

Demand response is an important emerging part of smart grids with wide coverage in theoretical and modeling research. However, experimental evidence on the real-life behavior of controllable loads is still limited. We present observations regarding latency and communication aspects of the operation on a fleet of residential water heaters in a smart neighborhood in Atlanta, GA. Our analysis shows that latency in water heaters is not constant and does not follow a Gaussian distribution. We also find that there is a systematic relationship between latency and hour of the day. Latency was found to increase during morning and evening hours compared to the afternoon. These findings could help better plan deployment of control for demand response programs. Understanding delays associated with controlling smart devices is crucial for proper design and algorithm development for optimization, frequency of dispatch, and override detection.

communication delay↗