Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Limitation of Liquid Crystal on Silicon Spatial Light Modular for Holographic Three-dimensional Displays

In a 3-D display system based on an opto-electronic reconstruction of a digitally recorded hologram, the field of view of such a system is limited by the spatial resolution of the liquid crystal on silicon (LCOS) spatial light modular (SLM) used to perform the opto-electronic reconstruction. In this article, the special resolution limitation of LCOS SLM associated with the fringe field effect and interpixel coupling is determined by the liquid crystal detector simulation and the Finite Difference Time Domain (FDTD) simulation. The diffraction efficiency loss associated with the imperfection in the phase profile is studied with an example of opto-electronic reconstruction of an amplitude object. A high spatial resolution LCOS SLM with a wide reconstruction angle is proposed.

Wang, Xinghua↗

Development and characterization of a laser-gated, high resolution x-ray radiography platform for high energy density experiments using toroidally bent crystals

Bent crystal x-ray imagers are a well-established diagnostic tool to study high energy density (HED) objects by acquiring two-dimensional x-ray radiographs. Often, studying these HED objects requires very high spatial resolution, which is limited by astigmatism when using spherically bent crystals. By using toroidal-shaped crystals instead, astigmatism can be reduced and the overall spatial resolution of the instrument improved. Here, the development and characterization of a laser-gated x-ray radiography platform at the National Ignition Facility using a toroidal crystal is presented. This includes measurements of the spatial and temporal profile, which is determined by the x-ray source. In conclusion, to properly validate the reduced astigmatism, a new multi-plane grid approach was implemented, which, for the first time, allows a depth of field measurement, alignment verification and x-ray source size estimate in a single shot, demonstrating the current platform’s capability to provide sub-10 μm resolution over a 0.9 mm depth of field with a temporal resolution of 110 ps.

Crystal optics↗

Shock-induced kinetics and cellular structures of liquid nitromethane detonation

Using a combination of high-speed diagnostics, optical pyrometry, velocimetry and video photography, we examine the spatiotemporal reaction kinetics of a prototypical high-energy explosive, liquid nitromethane (NM), as we drive this high explosive into detonation. The detonations were initiated by powerful shock waves whose durations (4 ns) were shorter than the characteristic time associated with the reaction (7 ns). Simple optical spectroscopy alone cannot characterize the kinetics with high time resolution because the reactants and products are flowing at a high velocity of ~6 km/s (6 µm/ns). Additionally, every detection volume behind the shock front contains material initiated over a range of times. High spatial resolution can be obtained by probing interfaces where the shock enters or breaks out of the NM. In addition, we obtain cellular patterns imprinted on the luminous shock front by the two-stage explosion in NM. These spatiotemporal patterns arise naturally as a result of the asymmetry produced by the moving shock front. In this way the shock front serves as a thin moving intrinsic optical gauge that reports and characterizes the two-stage NM explosion behind the front.

42 ENGINEERING↗

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy for rapid, label-free biological imaging

Broadband coherent anti-Stokes Raman scattering (BCARS) microscopy is a label-free imaging approach that provides detailed chemical information at high spatial resolution in a sample through nonlinear, coherent excitation of molecular vibrations and detection of Raman spectra. While its utility for biological imaging has been demonstrated, many aspects of this technique must mature before it can be widely adopted. One of the areas of required improvement is imaging speed—most BCARS implementations involve sample rastering, which limits imaging speed. Beam scanning can provide faster BCARS imaging but presents some unique challenges. Here, we describe a beam-scanning BCARS microscopy system that improves spatial resolution twofold and imaging speed by fivefold over a previous beam-scanning implementation. These enhancements were enabled by an improvement in supercontinuum power and the use of a sCMOS camera for its high data transfer rate and low read noise. Implementation of the sCMOS camera required correction for the significant pixel-to-pixel background and photon response nonuniformity. Here, we report on the method that we implemented for calibrating and correcting the pixel-to-pixel differences in sCMOS camera noise.

Dixon, Jessica Z. [Georgia Institute of Technology↗

Impact of thematic mapper sensor characteristics on classification accuracy

A three factor (spectral, spatial, and radiometric resolution), two level (TM and MSS) analysis of variance (ANOVA) approach allowed evaluation of the effects of each factor individually and in all possible combinations. Digital classification accuracy was used as the figure of merit. Nine study sites in Washington, DC, each of approximately 256 x 256 TM pixels, were randomly selected from the full scene for analysis. These results strongly suggest that the quantization level improvements and the addition of new spectral bands in the visible and middle IR regions (both afforded by the TM sensor design) can result in improved capabilities to accurately delineate land cover categories using a per point Gaussian maximum likelihood classifier. On the other hand, results indicate that the increase in spatial resolution to 30 m does not significantly enhance classification accuracy. The spatial result points to an inherent limitation of a per point classifier and to the need to improve data analysis techniques to handle high spatial resolution data.

Williams, D. L.↗

Millimeter Wave Holographical Inspection of Honeycomb Composites

Multi-layered composite structures manufactured with honeycomb, foam or balsa wood cores are finding increasing utility in a variety of aerospace, transportation, and infrastructure applications. Due to the low conductivity and inhomogeneity associated with these composites standard nondestructive testing (NDT) methods are not always capable of inspecting their interior for various defects caused during the manufacturing process or as a result of in-service loading. On the contrary, microwave and millimeter wave NDT methods are well-suited for inspecting these structures since signals at these frequencies readily penetrate through these structures and reflect from different interior boundaries revealing the presence of a wide range of defects such as disbond, delamination, moisture and oil intrusion, impact damage, etc. Millimeter wave frequency spectrum spans 30 GHz - 300 GHz with corresponding wavelengths of 10 - 1 mm. Due to the inherent short wavelengths at these frequencies, one can produce high spatial resolution images of these composites either using real-antenna focused or synthetic-aperture focused methods. In addition, incorporation of swept-frequency in the latter method (i.e., holography) results in high-resolution three-dimensional images. This paper presents the basic steps behind producing such images at millimeter wave frequencies and the results of two honeycomb composite panels are demonstrated at Q-band (33-50 GHz). In addition, these results are compared to previous results using X-ray computed tomography.

Case, J. T.↗

The iron oxidation state of Ryugu samples

The Hayabusa2 mission sampled Ryugu, an asteroid that did not suffer extensive thermal metamorphism, and returned rocks to the Earth with no significant air exposure. It therefore offers a unique opportunity to study the redox state of carbonaceous Cb-type asteroids and evaluate the overall redox state of the most primitive rocks of the solar system. An analytical framework was developed to investigate the iron mineralogy and valence state in extraterrestrial material at the micron scale by combining x-ray diffraction, conventional Mössbauer (MS), and nuclear forward scattering (NFS) spectroscopies. An array of standard minerals was analyzed and cross-calibrated between MS and NFS. Then, MS and NFS spectra on three Ryugu grains were collected at the bulk and the micron scales. In Ryugu samples, iron is essentially accommodated in magnetite, clay minerals (serpentine–smectite), and sulfides. Only a single set of Mössbauer parameters was necessary to account for the entire variability observed in MS and NFS spectra, at all spatial scales investigated. These parameters therefore make up a fully consistent iron mineralogical model for the Ryugu samples. As far as MS and NFS spectroscopies are concerned, Ryugu grains are overall similar to each other and share most of their mineralogical features with CI-type chondrites. In detail however, no ferrihydrite is found in Ryugu particles even at the very sensitive scale of Mössbauer spectroscopy. The typical Fe 3+ /Fe tot of clay minerals is much lower than typical redox ratios measured in CI chondrites (Fe 3+ /Fe tot = 85%–90%). Furthermore, magnetite from Ryugu is stoichiometric with no significant maghemite component, whereas up to 12% of maghemite was previously identified in the Orgueil's so-called magnetite. These differences suggest that most CI meteorites suffered terrestrial alteration and that the preterrestrial composition of these carbon-rich samples was less oxidized than previously measured. However, it is not clear yet whether or not the parent bodies of CI chondrites were as reduced as Ryugu. Finally, the high spatial resolution of NFS allows to disentangle the redox state and the crystal chemistry of iron accommodated in serpentine and smectite. The most likely polytype of serpentine is lizardite, containing <35% of Fe 3+ , a fraction of which being tetrahedrally coordinated. Smectite is more oxidized (Fe 3+ /Fe tot > 65%) and mainly contains octahedral ferric iron. In conclusion, this finding implies that these clays formed from highly alkaline fluids and the spatial variability highlighted here may suggest a temporal evolution or a spatial variability of the nature of this fluid.

58 GEOSCIENCES↗

Ultra-Long Distance BOTDA Sensor System Employing Hybrid Amplification and Advanced Noise Reduction Techniques

Brillouin Optical Time Domain Analysis (BOTDA) sensor systems play a pivotal role in distributed sensing, which enables precise measurements of strain and temperature across extensive fiber lengths. This research offers a comprehensive strategy to extend the sensing range of BOTDA systems beyond tens of kilometers while maintaining high spatial resolutions. Such enhanced sensing is realized through the integration of distributed Raman amplification, inline amplification using erbium-doped fiber amplifiers (EDFA), and advanced noise reduction techniques. Optimizing Raman pump and probe wave profiles ensures the robustness of Brillouin scattering signals, effectively countering attenuation-induced losses. Additionally, enhancing weak Brillouin signals by strategically placing EDFAs at optimal fiber locations keeps sensor sensitivity high. Leveraging inherent redundancy in measured data as a function of frequency and fiber distance, the non-local means (NLM) filter removes noise while preserving essential physical information. In summary, this research has shown a holistic exploration of extending BOTDA’s distance sensing capabilities up to 150 km with spatial resolutions of 8 meters.

Bhatta, Hari↗

Thermal infrared analysis of volcanic surfaces: Mars and Hawaii

High spatial resolution data from the Viking infrared thermal mapper (IRTM) are used to examine the Tharsis volcanoes which are situated within a vast area of low thermal inertia material very fine particle size or very high porosity, with the volcanoes having the lowest thermal inertias. Thermal infrared images of the 1823 flow on Kilauea's southwest rift zone show lower thermal inertias near the vent area where shelly pahoehoe is common while individual channelized aa flows with abundant broken pahoehoe slabs are higher thermal inertia. The increase in aa flows to the southeast leads to a general trend of increasing thermal inertias from near vent to distal areas. Martian shield volcanoes have thermal inertias equal to or higher than their surrounding plans when atmospheric effects are removed from the data. The general increase in thermal inertias away from the summit calderas is consistent with the trend of the Hawaiian 1823 flow and may be related to changing lava properties away from the summit.

Zimbelman, J. R.↗

A Rover Deployed Ground Penetrating Radar on Mars

Radar is a fundamental tool capable of addressing a variety of geological problems on Mars via collection of data suitable for interpreting variations in surface morphology and reflectivity. Surface-deployed ground penetrating radar (GPR) can help further constrain the geology and structure of the near surface of Mars by directly measuring the range and character of in situ radar properties. In recognition of this potential, a miniaturized, easily modified GPR is being developed for possible deployment on a future Mars rover and will enable definition of radar stratigraphy at high spatial resolution to depths of 10-20 meters. Ongoing development of a Mars impulse GPR with industry partners at Geophysical Survey Systems, Inc., focuses on design and testing of a prototype transducer array (with both high frequency bistatic and low frequency monostatic components) in parallel with fabrication of a low power, mass, and volume control unit. The operational depth of 10-20 meters is geared towards definition of stratigraphy, subsurface blocks, and structure at the decimeter to meter scale that is critical for establishing the geologic setting of the rover. GPR data can also be used to infer the degree of any post-depositional pedogenic alteration or weathering that has subsequently taken place, thereby enabling assessment of pristine versus secondary morphology at the landing site. As is the case for most remote sensing instruments, a GPR may not detect water unambiguously. Nevertheless, any local, near-surface occurrence of liquid water will lead to large, easily detected dielectric contrasts. Moreover, definition of stratigraphy and setting will help in evaluating the history of aqueous activity and where any water might occur and be accessible. Most importantly perhaps, GPR can provide critical context for other rover and orbital instruments/data sets. Hence, GPR deployment along well positioned transects in the vicinity of a lander should enable 3-D mapping of stratigraphy and could serve to guide direct subsurface sampling. Additional information is contained in the original extended abstract.

Grant, J. A.↗

Dual-Photoelastic-Modulator-Based Polarimetric Imaging Concept for Aerosol Remote Sensing

A dual-photoelastic-modulator- (PEM-) based spectropolarimetric camera concept is presented as an approach for global aerosol monitoring from space. The most challenging performance objective is to measure degree of linear polarization (DOLP) with an uncertainty of less than 0.5% in multiple spectral bands, at moderately high spatial resolution, over a wide field of view, and for the duration of a multiyear mission. To achieve this, the tandem PEMs are operated as an electro-optic circular retardance modulator within a high-performance reflective imaging system. Operating the PEMs at slightly different resonant frequencies generates a beat signal that modulates the polarized component of the incident light at a much lower heterodyne frequency. The Stokes parameter ratio q = Q/I is obtained from measurements acquired from each pixel during a single frame, providing insensitivity to pixel responsivity drift and minimizing polarization artifacts that conventionally arise when this quantity is derived from differences in the signals from separate detectors. Similarly, u = U/I is obtained from a different pixel; q and u are then combined to form the DOLP. A detailed accuracy and tolerance analysis for this polarimeter is presented.

spectropolarimetric imaging↗

In-Situ Spatial Mapping of Hydrogen in Yttrium Hydrides at LANSCE (FY23 Version, Rev. 1)

This report summarizes the development of neutron imaging capabilities and experimental activities performed at the Los Alamos Neutron Science Center (LANSCE) with the main goal of measuring temperature-driven hydrogen diffusion within bulk-yttrium hydride (YH x ) materials. Yttrium hydride is the leading candidate to serve as a solid neutron moderator in microreactor cores, owing to its high density of hydrogen atoms as well as its superior thermal stability compared to all other metal hydrides. The experimental results and technique developments reported herein support the U.S. Department of Energy Office of Nuclear Energy’s (DOE-NE) Microreactor Program under Technology Maturation. In particular, it addresses the critical need to experimentally validate and verify hydrogen-diffusion models of metal hydrides used in high-temperature microreactor designs by means of high-spatial-resolution neutron imaging. These capabilities were designed to apply large temperature gradients across centimeter-sized YH x pellets to simulate conditions faced in the microreactor environment. In principle, neutron imaging, combined with in-situ sample heating, enables near real-time tracking of hydrogen diffusion in YH x on the sub-millimeter scale. In this report, an overview of neutron imaging methodology and technologies are given in the context of recent spatial measures of hydrogen concentrations in similar metal hydrides. Additionally, the commissioning and operation of a custom-built compact dual-zone furnace is given along with details on three in-situ heating measurements of YH x performed over the 2020 to 2022 LANSCE operation cycles. The aims of these experiments ranged from furnace commissioning, determining sample quality, i.e., hydrogen uniformity via neutron computed tomography, and studying the effects of applied temperature-gradients on YH x pellets. Analyses and results from these neutron imaging measurements are given along with outlooks and guidelines for optimal future hydrogen diffusion measurements. Our conclusions are as follows. Image analyses indicate that centimeter-sized yttrium hydride cylindrical pellets exhibit uniform, whole-body hydrogen desorption and absorption without clear temperature dependence as reflected in the image attenuation at the opposing ends of each sample. This suggests that despite the large magnitude in temperature gradients applied by the furnace heating elements, the sample equilibrates to an unknown intermediate temperature. The origin of this result is likely the combination of short sample length (∼1cm) and use of a TZM can for containment where the latter created a thermal short across the sample. Nevertheless, the results from the most recent measurements indicate that neither significant concentration gradients of hydrogen were formed in centimeter-sized samples through the entire temperature range (25 °C to 950 °C) nor any formed due to temperature gradients on the order of 50 °C/cm up to 700 °C/cm. Furthermore, images from the FY2021 and FY2022 measurements indicate that samples of YH x , fabricated from either the direct hydride or powder metallurgy methods, are highly uniform in their hydrogen concentration to within the measurements’ spatial resolutions. The following questions arise from these latest results: 1) What is the intermediate temperature of the pellets in the TZM cans? 2) How quickly does the temperature equilibrate within the sample? and, 3) Do the observed changes in image attenuation follow known pressure-composition-temperature relations of yttrium hydride?

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced magnetic X-ray spectro-microscopies to characterize mesoscopic magnetic materials

Here, this article provides a brief overview of advanced magnetic X-ray spectro-microscopies that are widely used in characterizing mesoscopic magnetic materials. Common to those techniques are various X-ray magnetic dichroism effects that are used as magnetic contrast mechanism. A particular interest is to use those techniques to image the underlying microscopic spin structures in magnetic materials with high spatial resolution and to ultimately resolve their full 3D mesoscale characteristics with elemental sensitivity, as well as their ultrafast dynamics upon excitations with field and current pulses. Recent research examples using various magnetic X-ray spectro-microscopies are presented to showcase their specific features with a focus on imaging novel topological spin textures, such as vortices, skyrmions and Hopfions, which are considered as potential building blocks towards low power, high-speed and high-density magnetic devices that could transform information technologies and potentially be used in biomedical applications. Future developments with magnetic X-ray spectro-microscopies harness the full coherence of next generation X-ray sources and could open the path towards single shot imaging with spatial and temporal resolutions down to fundamental magnetic length and time scales.

36 MATERIALS SCIENCE↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

MEGASIM: Distribution and Detection of Earth Trojan Asteroids

Abstract Using N -body simulation results from the MEGASIM data set, we present spatial distributions of Earth Trojan Asteroids and assess the detectability of the population in current and next-generation ground-based astronomical surveys. Our high-fidelity Earth Trojan Asteroid (ETA) distribution maps show never-before-seen high-resolution spatial features that evolve over timescales up to 1 Gyr. The simulation was synchronized to start times and timelines of two observational astronomy surveys: (1) the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) and (2) the Zwicky Transient Facility (ZTF). We calculate upper limits for the number of ETAs potentially observable with both the ZTF and LSST surveys. Due to the Yarkovsky Effect, we find no stable ETAs on billion-year timescales likely to be detected by any ETA survey, as no C-type or S-type ETAs (with H < 22 and H < 24, respectively) are likely to be stable on billion-year timescales, and ETAs large enough to remain stable on billion-year timescales are very rare relative to the rest of the ETA population. We find that a twilight ETA survey will not drastically increase the likelihood of individual ETA detection, but it would provide orders of magnitude more observations of select ETA populations. The null detection to date from ZTF restricts the potential ETA population to hundreds of objects larger than 100 m (at H ≈ 22), while a null detection by LSST will further restrict the ETA population to tens of objects larger than 100 m.

79 ASTRONOMY AND ASTROPHYSICS↗

Infrared studies of star formation in Orion

The results of IR studies of the cluster of compact IR sources in the Orion Molecular Cloud are discussed in view of broad band and low spectral resolution measurements, and with attention to new measurements of the 8-12.5-micron color temperature, the 3.8-micron polarization of the IR emission from the vicinity of the cluster, and new 34-micron maps of the region which possess high spatial resolution. These measurements are found to be useful in the identification of the principal luminosity sources within the cluster. The propects for future star formation studies which have their basis in the use of space telescopes optimized for IR observation are also discussed.

Werner, M. W.↗

A modified objective mapping technique for scatterometer wind data

A method for generating high-resolution wind maps from scatterometer data was developed and tested on synthetic data for the northeast Pacific Ocean. It is shown that, unlike the wind fields generated by current GCMs, the wind maps constructed by this method retain the high spatial resolution of the scatterometer wherever adequate measurements exist. For the NASA scatterometer, this method would produce every 12 hours a wind map with spatial resolution that preserves the small-scale features of the original data over about half the mapped region. Over the rest of the region, maps with somewhat lower resolution and accuracy will be obtained.

Kelly, Kathryn A.↗

Bayesian Geostatistical Modelling of PM10 and PM2.5 Surface Level Concentrations in Europe Using High-Resolution Satellite-Derived Products

Air quality monitoring across Europe is mainly based on in situ ground stations which are too sparse to accurately assess the exposure effects of air pollution for the entire continent. The demand for precise predictive modelsthat estimate gridded geophysical parameters of ambient air at high spatial resolution has rapidly grown. Here, we investigate the potential of satellite derived products to improve particulate matter (PM) estimates. Bayesiangeostatistical models addressing confounding between the spatial distribution of pollutants and remotely sensed predictors were developed to estimate yearly averages of both, fine (PM2.5) and coarse (PM10) surface PM concentrations at 1 sq.km spatial resolution over 46 European countries and were compared to geostatistical, geographically weighted and land-use regression formulations. Rigorous model selection identified the Earth observation data which contribute most to pollutants' estimation. Geostatistical models outperformed the predictive ability of the frequently employed land-use regression. The resulting estimates of PM10 and PM2.5, which represent the main air quality indicators for the urban Sustainable Development Goal, indicate that in 2016, 66.2% of the European population was breathing air above the WHO Air Quality Guidelines thresholds. Our estimates are readily available to policy makers and scientists assessing the effects of long-term exposure to pollution on human and ecosystem health.

Beloconi, Anton↗