Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Transfer Fluid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Glenn-HT: The NASA Glenn Research Center General Multi-Block Navier-Stokes Heat Transfer Code

For the last several years, Glenn-HT, a three-dimensional (3D) Computational Fluid Dynamics (CFD) computer code for the analysis of gas turbine flow and convective heat transfer has been evolving at the NASA Glenn Research Center. The code is unique in the ability to give a highly detailed representation of the flow field very close to solid surfaces in order to get accurate representation of fluid heat transfer and viscous shear stresses. The code has been validated and used extensively for both internal cooling passage flow and for hot gas path flows, including detailed film cooling calculations and complex tip clearance gap flow and heat transfer. In its current form, this code has a multiblock grid capability and has been validated for a number of turbine configurations. The code has been developed and used primarily as a research tool, but it can be useful for detailed design analysis. In this paper, the code is described and examples of its validation and use for complex flow calculations are presented, emphasizing the applicability to turbomachinery for space launch vehicle propulsion systems.

Gaugler, Raymond E.↗

Glenn-HT: The NASA Glenn Research Center General Multi-Block Navier-Stokes Heat Transfer Code

For the last several years, Glenn-HT, a three-dimensional (3D) Computational Fluid Dynamics (CFD) computer code for the analysis of gas turbine flow and convective heat transfer has been evolving at the NASA Glenn Research Center. The code is unique in the ability to give a highly detailed representation of the flow field very close to solid surfaces in order to get accurate representation of fluid heat transfer and viscous shear stresses. The code has been validated and used extensively for both internal cooling passage flow and for hot gas path flows, including detailed film cooling calculations and complex tip clearance gap flow and heat transfer. In its current form, this code has a multiblock grid capability and has been validated for a number of turbine configurations. The code has been developed and used primarily as a research tool, but it can be useful for detailed design analysis. In this presentation, the code is described and examples of its validation and use for complex flow calculations are presented, emphasizing the applicability to turbomachinery.

Gaugfer, Raymond E.↗

Surface heat transfer and flow properties of vortex arrays induced artificially and from centrifugal instabilities

The paper presents and compares fluid-flow and heat transfer properties from artificially induced vortices in a flat-plate turbulent boundary layer and naturally occurring vortices due to centrifugal instabilities in a curved-channel laminar flow. Pairs and arrays of vortices are artificially induced by placing half-delta wings on the plate surface. With both arrays and pairs of vortices, streamwise velocities and total pressures are high, and surface heat transfer is locally augmented in vortex downwash regions. In contrast to vortices in the arrays vortices in the pairs tend to move in the streamwise direction with significant divergence (when the common flow between pair is toward the wall) or convergence (when the common flow between pair is away from the wall). The vortices in the arrays cause maximum peak-to-peak heat transfer variations of up to 12 percent of local spanwise-averaged values for initial vortex spacings between 1 to 2.5 generator heights.

Subramanian, C. S.↗

Parametric Study of Panel PCM–Air Heat Exchanger Designs

Heat exchangers, devices for the transfer of heat between two or more working fluids, are extensively used in cooling applications and heating applications. Heat exchangers in buildings are typically components of space-conditioning systems, as well as of water-heating applications. Heat exchangers are also sometimes used in applications that require storage and release of energy at specific times. Phase change materials (PCMs) enhance these heat-exchange processes, given their ability to melt and solidify at a fixed range of temperatures, absorbing or releasing significant amounts of latent heat. Five different configurations of PCM–air heat exchangers for thermal control in buildings are analyzed in this work. The heat exchangers were fitted with PCM encapsulated in plastic and composite pouches of various shapes, and packaged in stackable panel layers. Three-dimensional computational fluid dynamics (CFD) modeling of coupled incompressible fluid and conjugate heat transfer were performed on the designs. The phase change process was numerically modelled using the apparent heat capacity method. Steady-state CFD simulations provided quantification of pressure drop as a function of air flow velocity. Transient simulation results describe the thermal evolution of PCM in the pouches, helping to determine the best performing configuration with respect to total thermal charging time.

10 SYNTHETIC FUELS↗

Thermal Analysis of Magnetically-Coupled Pump for Cryogenic Applications

Magnetically-coupled pump is under evaluation at Kennedy Space Center for possible cryogenic applications. A major concern is the impact of low temperature fluid flows on the pump performance. As a first step toward addressing this and related issues, a computational fluid dynamics and heat transfer tool has been adopted in a pump geometry. The computational tool includes (i) a commercial grid generator to handle multiple grid blocks and complicated geometric definitions, and (ii) an in-house computational fluid dynamics and heat transfer software developed in the Principal Investigator's group at the University of Florida. Both pure-conduction and combined convection-conduction computations have been conducted. A pure-conduction analysis gives insufficient information about the overall thermal distribution. Combined convection-conduction analysis indicates the significant influence of the coolant over the entire flow path. Since 2-D simulation is of limited help, future work on full 3-D modeling of the pump using multi-materials is needed. A comprehensive and accurate model can be developed to take into account the effect of multi-phase flow in the cooling flow loop, and the magnetic interactions.

Senocak, Inanc↗

Monocoque shell and tube heat exchanger

A heat exchanger with a monocoque structure transfers heat between a first fluid and a second fluid. The heat exchanger in has a plurality of tubes through which the first fluid may flow in a direction, each of the plurality of tubes has a first mouth end, an N opposing second mouth end and a waist region between the first mouth end and the second mouth end. The heat exchanger also has one or more interconnected fluid channels through which the second fluid may flow, the one or more fluid channels lay generally in a plane, the plurality of tubes and the one or more fluid channels interleave such that heat may be transferred between the plurality of tubes and the one or more fluid channels, and the direction of flow of the first fluid is generally perpendicular to the plane of the one or more fluid channels.

Keolian, Robert M.↗

Simulation of the Heat Transfer Characteristics of LOX

Forced convection heat transfer data for fluid nitrogen flowing through a vertical tube were acquired and assumed to simulate the heat transfer characteristics of LOX. Comparisons between LN2 and LOX data over the pressure range for T sub r 1 using a modified form of Petukhov's correlation factor was shown, qualitatively, to substantiate the simulation. Other parameters (buoyancy, Stanton number, and relative velocity), were found to group those data; assessment of these parametric interrelations must be made before the simulation can be termed quantitative.

Hendricks, R. C.↗

Experimental and Numerical Investigation of Flow Boiling in Additive Manufactured Foam Structures With Vapor Pathways

Abstract The unique properties of metal foams make them potential candidates for a range of applications, including microsystem thermal management. Using additive manufacturing to create foam-type structures can improve upon prior thermal solutions by eliminating thermal interface materials and allowing for customization/local control of parameters. In the present investigation, flow boiling in additive-manufactured metal foams is investigated both experimentally and numerically. Two test samples, one with uniform structure and the other with pathways for vapor removal, are compared both experimentally and numerically. A conjugate computational fluid dynamics and heat transfer (CFD-HT) model utilizing a three-dimensional volume of fluid (VOF) model with accompanying evaporation/condensation model provided in-depth visualization of the boiling flow phenomena. The experiments generated the thermohydraulic performance over a range of heat fluxes, demonstrating that the sample incorporating dedicated vapor pathways performed better in both pressure and heat transfer performance metrics compared to the uniform foam. Additionally, negative system-level effects (i.e., hydraulic oscillations) were shown to be abated using the vapor removal structures. The numerical model yielded further insight into the factors contributing to the improved performance. Results indicated the pathways functioned as vapor removal channels, allowing the generated vapor to vent from the foam structure into the lanes. Further computational investigations demonstrated changes in flow regimes, where the addition of vapor channels caused the flow to change from churn to annular. Bubble behavior unique to the vapor pathway structure was studied, showing stagnant regions that eject vapor into the channel.

Engineering↗

Ninth Thermal and Fluids Analysis Workshop Proceedings

The Ninth Thermal and Fluids Analysis Workshop (TFAWS 98) was held at the Ohio Aerospace Institute in Cleveland, Ohio from August 31 to September 4, 1998. The theme for the hands-on training workshop and conference was "Integrating Computational Fluid Dynamics and Heat Transfer into the Design Process." Highlights of the workshop (in addition to the papers published herein) included an address by the NASA Chief Engineer, Dr. Daniel Mulville; a CFD short course by Dr. John D. Anderson of the University of Maryland; and a short course by Dr. Robert Cochran of Sandia National Laboratories. In addition, lectures and hands-on training were offered in the use of several cutting-edge engineering design and analysis-oriented CFD and Heat Transfer tools. The workshop resulted in international participation of over 125 persons representing aerospace and automotive industries, academia, software providers, government agencies, and private corporations. The papers published herein address issues and solutions related to the integration of computational fluid dynamics and heat transfer into the engineering design process. Although the primary focus is aerospace, the topics and ideas presented are applicable to many other areas where these and other disciplines are interdependent.

Sakowski, Barbara↗

Transient heat transfer and thermophysical properties measurements in low gravity

Theoretical computer models and correlations which describe phenomena important in the design of transient heat transfer systems are verified and extended. Attention is given to heat transfer to a fluid near the thermodynamic critical point, i.e., a highly compressible fluid. The validity of the computer model is tested by conducting heat-transfer experiments in a low gravity environment where gravity-driven motion is essentially eliminated. It is noted that the NASA KC135 aircraft provides a useful low-g platform for experimental work and provides valuable experience and background for experiments ultimately designed to fly on the Space Shuttle.

Giarratano, P. J.↗

Improved natural convection heat transfer correlations for reactor cavity cooling systems of high-temperature gas-cooled reactors: From computational fluid dynamics to Pronghorn

The Reactor Cavity Cooling System (RCCS) is a common reactor safety system in High Temperature Gas Cooled Reactors (HTGR) that removes heat from the Reactor Pressure Vessel (RPV) by radiation ($\sim 80\%$) and natural convection ($\sim 20\%$). For simulation of accident scenarios of HTGRs, intermediate fidelity and system codes models must be employed for limiting the models' execution time. While accurate quantification of the radiative heat transfer is available in these models, quantification of natural convection must rely on correlations of questionable accuracy for the Nusselt number. Commonly used correlations are based in experiments performed at low Rayleigh numbers and/or using isothermal walls in simplified geometries. Here, this work improves on the accuracy of natural convection heat transfer correlations in support for HTGR designs. These correlations include both local and average Nusselt numbers as a function of the global Rayleigh number, the local Rayleigh number, and the temperature profile at the hot wall of the RCCS. In the absence of dedicated experiments and the difficulty of performing high-fidelity simulations at realistic Rayleigh numbers, the data to fit the correlations are generated with Computational Fluid Dynamics (CFD) using Reynolds Averaged Navier-Stokes (RANS) models. First, a careful selection of the RANS turbulence model is performed by comparing the results obtained with different RANS turbulence models against high fidelity simulations of natural convection at $Ra \ 1 \times 10^{11}$ in a rectangular cavity. Next, the selected model is used to perform simulations of an HTGR cavity at different high Rayleigh numbers $\in [6.1 \times 10^{11},2.9 \times 10^{13}]$ to encompass several HTGR designs, assuming an isothermal RPV wall. The results obtained are used to fit a correlation for the average and space-varying Nusselt number as a function of the global and local Rayleigh numbers via a sparsity-promoting least-squares method. The selected RANS model is then used to perform simulations of a PBMR 400 HTGR cavity with the temperature profiles at the RPV wall obtained during a PLOFC transient. We use the results obtained to fit a temperature-dependent correction to the space-varying Nusselt number with the sparsity-promoting least-squares method. The results obtained in this work, enable system-level codes, such as Pronghorn, to perform higher-fidelity simulations of the heat exchange process in the RCCS while still maintaining a low computational cost.

42 ENGINEERING↗

Analysis of a heat transfer device for measuring film coefficients

A heat transfer device consisting of a heated rotating cylinder in a bath was analyzed for its effectiveness to determine heat transfer coefficient of fluids. A time dependent analysis shows that the performance is insensitive to the value of heat transfer coefficient with the given rig configuration.

Medrow, R. A.↗

Experimental and Computational Heat Transfer Study of sCO2 Single Jet Impingement

The present study experimentally investigates the heat transfer capability of supercritical carbon dioxide (sCO2) single-jet impingement. The evaluated jet Reynolds number range is between 80,000 and 1,000,000, with a non-dimensional jet-to-target surface spacing of 2.8. CO2- impinging jet stagnation conditions were maintained at approximately 20 MPa and a temperature of 673 K for most experiments. The goal is to understand how changes in the aforementioned parameters influence heat transfer between the working fluid and the heated surface. Additionally, due to the elevated Reynolds numbers and difference in thermodynamic properties between air and CO2, air-derived impingement correlations may not be appropriate for CO2 impingement; these correlations will be evaluated against experimental sCO2 impingement data. At the time of this study, no sCO2 impingement data was available relevant to sCO2 power cycles. The target surface is a 1.5-inch diameter copper block centered on the 3mm jet orifice. A mica heating element bolted to the bottom of the copper block provides a uniform heat flux. Thermocouples embedded in the copper block are used to determine the surface temperature. Nusselt numbers obtained from experimental sCO2 data are compared to area-averaged Nusselt numbers from air-derived correlations. The comparisons showed that air correlations drastically underpredict the heat transfer when sCO2 is used as the working fluid. A modified sCO2 correlation using experimental data at discussed conditions is derived based on an existing air correlation.

Richardson, John↗

Modeling and Experimental Validation of a Direct-Contact Counter-Flow Fluidized Bed Heat Exchanger for Thermal Energy Storage (TES) Applications

Particle-based thermal energy storage (TES) systems are an emerging energy storage technology. The technological advances have reduced costs, making TES more competitive and reliable in the marketplace but an efficient and reliable operation is heavily dependent on coherent heat transfer between air to particles or vice versa. The particle-based TES technologies provide an intermediate system that can store energy for short (0-10 h), long (10-200 h) and seasonal (> 200 h) timescales. The TES systems store energy by converting electricity to thermal energy; electricity can be directly sourced intermittent generation technologies and/or the grid, helping manage peak loads and other mismatches in supply and demand. The overall efficiency of the TES system depends on the performance of system components (particle storage silos and particle transfer mechanism etc.). The particle heat exchanger is one of the key system components that affects the system efficiency. The pressurized fluidized bed heat exchanger (PFB HX) performance is challenging to predict due to the chaotic behavior of particle and fluid interaction. This research presents a computational study of a novel direct-contact, counter-flow and air-to-particles PFB HX, that contributes in advancing the particle-based long-duration TES technologies. For the current analysis an unsteady Eulerian-Eulerian CFD model was developed and validated against experiments performed at the National Laboratory of the Rockies for two particle sizes (600 ..mu..m and 825 ..mu..m ). Following validation, parametric simulations were conducted to evaluate the effects of interphase drag models (Syamlal-O'Brien and Gidaspow), particle size, bed height and the influence of a frictional-viscosity term on hydrodynamics and heat transfer between the air & particles. The key findings from the analysis are: (1) for the studied operating window Syamlal-O'Brien provides superior agreement with measured gas temperatures (errors generally < 10%) while Gidaspow shows large deviations for the coarse particle case; (2) model predictions are most sensitive in the lower 0.2 m above the air distributor where bubble initiation and local mixing dominate interphase heat transfer; (3) representation of the distributor (number of inlet ports) materially affects predicted local mixing and temperature stratification; and (4) the Eulerian-Eulerian framework reproduces bulk thermal trends but shows regime dependent limitations for coarse particles, motivating mesoscale informed closures for scale-up analysis for future studies. These results provide validated guidance for drag selection and distributor design in particle-based thermal energy storage applications. Collectively, the validated model and parametric results quantify key drivers of PHB-HX performance and provide practical guidance for design and optimization. The results provide confidence in the model predictability and provide a step forward to improve on heat exchange performance. The demonstrated performance and modeling approach support the deployment and further development of this novel PHB-HX concept for robust, particle-based long-duration thermal energy storage systems.

25 ENERGY STORAGE↗

Numerical Simulation of No Vent Chill and Fill of a Large Liquid Hydrogen Tank

On orbit transfer of cryogenic liquids is necessary for many future space missions. The techniques required to transfer cryogens in micro gravity are quite different from ground system applications. In normal gravity, cryogenic tanks are usually filled from the bottom at nearly atmospheric pressure. The vapor generated due to heat transfer from warm tank walls, is allowed to vent from the top of the tank while the tank is being filled. If the normal gravity technique is used on orbit, the uncertainty of liquid and vapor distributions in unsettled condition may result in dumping of large amounts of liquid propellant overboard. The Vented Chill and No Vent Fill (VCNVF) process is a methodology [1] used to reduce propellant loss by holding the vent valve open during initial wall chilldown, preventing over-pressurization of the tank and stalling of the incoming flow, but closing the tank vent valve after chilling the tank wall sufficiently. An accurate simulation of no vent tank chill and fill is necessary to estimate the amount of propellant necessary to chill the tank, determine the maximum sustainable flowrate to fill the tank without stalling, and establish a timeline for the filling process. Numerical modeling of filling a cryogenic tank is complex because the flow is two-phase and the process involves both boiling and condensation with heat transfer between solid and fluid. In recent years, progress has been made to develop a numerical modeling technique [2,3,4] that has been verified by comparing with the test data from a small flight tank using liquid nitrogen [5]. The purpose of the present paper is to apply this technique in a larger tank with liquid hydrogen and compare with the test data of Chato [1]. The K-site Test Facility [1], shown in Figure 1, consists of a Test Tank, spray system, instrumentation, and the vacuum chamber. The test tank selected was ellipsoidal with an 87 inch major diameter and a 1.2 to 1 major to minor axis ratio. The two ends are joined by a short 1.5 inch cylindrical section. The tank is made of 2219 aluminum chemically milled to a nominal thickness of 0.087 inches. The tank weighs 329.25 pounds, and the tank volume is 175 ft 3 . The GFSSP model of the Test Tank is shown in Figure 2. Node 13 is a boundary node that represents the supply tank which is supplying liquid hydrogen at a given pressure and temperature. The total measured flowrate is evenly distributed through Branches 131 through 139. Nodes 1 through 9 represent the test tank and they are connected with metal solid nodes 14 through 22 through fluid-to-solid conductors that allow convective heat transfer between the solid and fluid nodes. The predicted tank pressure, filling rate, wall temperature and fluid temperature will be compared with test data.

Alok Majumdar↗

Three-Dimensional Aeroelastic and Aerothermoelastic Behavior in Hypersonic Flow

The aeroelastic and aerothermoelastic behavior of three-dimensional configurations in hypersonic flow regime are studied. The aeroelastic behavior of a low aspect ratio wing, representative of a fin or control surface on a generic hypersonic vehicle, is examined using third order piston theory, Euler and Navier-Stokes aerodynamics. The sensitivity of the aeroelastic behavior generated using Euler and Navier-Stokes aerodynamics to parameters governing temporal accuracy is also examined. Also, a refined aerothermoelastic model, which incorporates the heat transfer between the fluid and structure using CFD generated aerodynamic heating, is used to examine the aerothermoelastic behavior of the low aspect ratio wing in the hypersonic regime. Finally, the hypersonic aeroelastic behavior of a generic hypersonic vehicle with a lifting-body type fuselage and canted fins is studied using piston theory and Euler aerodynamics for the range of 2.5 less than or equal to M less than or equal to 28, at altitudes ranging from 10,000 feet to 80,000 feet. This analysis includes a study on optimal mesh selection for use with Euler aerodynamics. In addition to the aeroelastic and aerothermoelastic results presented, three time domain flutter identification techniques are compared, namely the moving block approach, the least squares curve fitting method, and a system identification technique using an Auto-Regressive model of the aeroelastic system. In general, the three methods agree well. The system identification technique, however, provided quick damping and frequency estimations with minimal response record length, and therefore o ers significant reductions in computational cost. In the present case, the computational cost was reduced by 75%. The aeroelastic and aerothermoelastic results presented illustrate the applicability of the CFL3D code for the hypersonic flight regime.

McNamara, Jack J.↗

Optimal gas cooling with minimal aero-opticaldistortion for next generation high-average-power lasers (Progress report, Year 2)

Next-generation lasers that combine high-peak-power ultrashort pulses with high repetition rates have the potential to efficiently deliver the high-average-power outputs required for inertial fusion energy generation, laser-based particle acceleration, and to generate compact secondary x- and 𝛾-ray radiation sources, among others. The combination of long gain length with high surface-to-volume ratio to remove residual heat makes gas-cooled multi-slab amplifier heads an inherently aperture- and average power scalable technology that enables this new class of solid-state lasers, and their thermal management becomes the most pressing technical challenge. As the index-of refraction depends on the gas density, heat removal from the slab surfaces unavoidably entails scattering of propagated light from regions of high temperature fluctuations. The requirement to maximize convective heat extraction from the gain medium under the constraint of minimum optical aberration of the beam renders amplifier slab cooling a technological challenge at the intersection of aero-optics, fluid-mechanics and heat transfer. The goal of this research is to leverage computational fluid dynamics and aero optics simulations of different levels of fidelity to devise a numerical modeling and optimization framework for gas-cooled multi-slab amplifiers. The project will be conducted in close collaboration with the Advanced Photon Technologies Group at Lawrence Livermore National Laboratory, where a gas-cooled test stand for laser materials and thermal management structures will be developed and installed. The final goal of the collaborative effort is to manufacture and benchmark a physical prototype of an numerically optimized amplifier head design. Measurement data on solid-state and thermo-optical distortions will be used for the validation of the numerical models. The key technical challenge in this multi-objective design problem is that of balancing optimal heat removal with minimal optical distortion. To facilitate computationally efficient design optimization and, at the same time, deepen our basic understanding of the interaction of light with turbulence, a complementary study that combines high and low-fidelity flow simulations and aero-optical models is proposed. Along the lines of these two objectives and solution strategies, the project is organized into two thrusts.

42 ENGINEERING↗