Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HANDBOOK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Author Contribution to the Pu Handbook II: Chapter 37 LLNL Integrated Sample Preparation Glovebox (TEM) Section

The development of our Integrated Actinide Sample Preparation Laboratory (IASPL) commenced in 1998 driven by the need to perform transmission electron microscopy studies on naturally aged plutonium and its alloys looking for the microstructural effects of the radiological decay process (1). Remodeling and construction of a laboratory within the Chemistry and Materials Science Directorate facilities at LLNL was required to turn a standard radiological laboratory into a Radiological Materials Area (RMA) and Radiological Buffer Area (RBA) containing type I, II and III workplaces. Two inert atmosphere dry-train glove boxes with antechambers and entry/exit fumehoods (Figure 1), having a baseline atmosphere of 1 ppm oxygen and 1 ppm water vapor, a utility fumehood and a portable, and a third double-walled enclosure have been installed and commissioned. These capabilities, along with highly trained technical staff, facilitate the safe operation of sample preparation processes and instrumentation, and sample handling while minimizing oxidation or corrosion of the plutonium. In addition, we are currently developing the capability to safely transfer small metallographically prepared samples to a mini-SEM for microstructural imaging and chemical analysis. The gloveboxes continue to be the most crucial element of the laboratory allowing nearly oxide-free sample preparation for a wide variety of LLNL-based characterization experiments, which includes transmission electron microscopy, electron energy loss spectroscopy, optical microscopy, electrical resistivity, ion implantation, X-ray diffraction and absorption, magnetometry, metrological surface measurements, high-pressure diamond anvil cell equation-of-state, phonon dispersion measurements, X-ray absorption and emission spectroscopy, and differential scanning calorimetry. The sample preparation and materials processing capabilities in the IASPL have also facilitated experimentation at world-class facilities such as the Advanced Photon Source at Argonne National Laboratory, the European Synchrotron Radiation Facility in Grenoble, France, the Stanford Synchrotron Radiation Facility, the National Synchrotron Light Source at Brookhaven National Laboratory, the Advanced Light Source at Lawrence Berkeley National Laboratory, and the Triumph Accelerator in Canada.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Single-Particle Soot Photometer (SP2) Instrument Handbook

The SP2 is an instrument that measures, in situ, the time-dependent scattering and incandescence signals produced by individual BC-containing particles as they travel through a continuous-wave laser beam. Any particle traversing the laser beam will scatter light, and the BC component of a BC-containing particle will absorb some of the laser energy until its temperature is raised to the point at which it incandesces (hereafter we adopt the standard terminology of the SP2 community and denote any substance determined by the SP2 to be BC as refractory black carbon (rBC)). The amplitude of the rBC incandescence signal is related to the amount of refractory material contained in the illuminated particle. By binning the individual incandescence signals per unit sample volume, the mass concentration [ng/m3] of rBC can be derived. By binning the individual signals by volume equivalent diameter the size distribution (dN/dlogDVED) per unit time can be derived. The rBC mass loading per unit time and the rBC size distribution unit time are the core data products produced by the SP2. Additionally, the scattering channel can be used to provide information on the rBC particle population-based mixing states within ambient aerosols. However, this data product is produced on a requested-basis since additional detailed analysis and QC/QA must be conducted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Meteorological Automatic Weather Station (MAWS) Instrument Handbook

The Meteorological Automatic Weather Station (MAWS) is a surface meteorological station, manufactured by Vaisala, Inc., dedicated to the balloon-borne sounding system (BBSS), providing surface measurements of the thermodynamic state of the atmosphere and the wind speed and direction for each radiosonde profile. These data are automatically provided to the BBSS during the launch procedure and included in the radiosonde profile as the surface measurements of record for the sounding. The MAWS core set of measurements is: Barometric Pressure (hPa), Temperature (°C), Relative Humidity (%), Arithmetic-Averaged Wind Speed (m/s), and Vector-Averaged Wind Direction (deg). The sensors that collect the core variables are mounted at the standard heights defined for each variable.

58 GEOSCIENCES↗

Aerosol Chemical Speciation Monitor (ACSM) Instrument Handbook

The Aerodyne Aerosol Chemical Speciation Monitor (ACSM) measures particle mass loading and chemical composition in real time for non-refractory sub-micron aerosol particles. The ACSM is designed for long-term unattended deployment and routine monitoring applications.

54 ENVIRONMENTAL SCIENCES↗

Portable Radiation Package (PRP) Instrument Handbook

The Portable Radiation Package (PRP) was developed to provide basic radiation information in locations such as ships at sea where proper exposure is remote and difficult, the platform is in motion, and azimuth alignment is not fixed. Development of the PRP began at Brookhaven National Laboratory (BNL) in the mid-1990s and versions of it were deployed on ships in the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Nauru-99 project. The PRP was deployed on ships in support of the National Aeronautics and Space Administration (NASA) Sensor Intercomparison for Marine Biological and Interdisciplinary Ocean Studies (SIMBIOS) program. Over the years the measurements have remained the same while the post-processing data analysis, especially for the FRSR, has evolved. This document describes the next-generation Portable Radiation Package (PRP2) that was developed for the DOE ARM Facility, under contract no. 9F-31462 from Argonne National Laboratory (ANL). The PRP2 has the same scientific principles that were well validated in prior studies, but has upgraded electronic hardware. The PRP2 approach is completely modular, both in hardware and software. Each sensor input is treated as a separate serial stream into the data collection computer. In this way the operator has complete access to each component of the system for purposes of error checking, calibration, and maintenance. The resulting system is more reliable, easier to install in complex situations, and more amenable to upgrade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SiC/SiC Cladding Materials Properties Handbook

When a new class of material is considered for a nuclear core structure, the in-pile performance is usually assessed based on multi-physics modeling in coordination with experiments. This report aims to provide data for the mechanical and physical properties and environmental resistance of silicon carbide (SiC) fiber–reinforced SiC matrix (SiC/SiC) composites for use in modeling for their application as accidenttolerant fuel cladding for light water reactors (LWRs). The properties are specific for tube geometry, although many properties can be predicted from planar specimen data. This report presents various properties, including mechanical properties, thermal properties, chemical stability under normal and offnormal operation conditions, hermeticity, and irradiation resistance. Table S.1 summarizes those properties mainly for nuclear-grade SiC/SiC composites fabricated via chemical vapor infiltration (CVI). While most of the important properties are available, this work found that data for the in-pile hydrothermal corrosion resistance of SiC materials and for thermal properties of tube materials are lacking for evaluation of SiC-based cladding for LWR applications.

36 MATERIALS SCIENCE↗

Tethered Balloon System (TBS) Instrument Handbook

The Tethered Balloon System (TBS) is an unmanned aerial system composed of a helium-filled balloon, tether, winch, and sensors. Individual components of the system may change with each flight based on the desired measurements, atmospheric conditions, and flight strategy. The TBS operates within the U.S. Department of Energy (DOE)’s R-2204 Restricted Airspace, which encompasses a two-nautical-mile radius centered on Oliktok Point, Alaska that is segmented by altitude into R-2204 Low (0-1,499’ MSL or 0-457 m MSL) and R-2204 High (1,500-6,999’ MSL or 457-2133 m MSL). The TBS may operate outside of R-2204 if allowed to do so under a Certificate of Authorization from the Federal Aviation Administration.

42 ENGINEERING↗

Infrared Thermometer (IRT) Instrument Handbook

The Infrared Thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the equivalent blackbody brightness temperature of the scene in its field of view. The downwelling version has a narrow field of view for measuring sky temperature and for detecting clouds. The upwelling version has a wide field of view for measuring the narrowband radiating temperature of the ground surface.

47 OTHER INSTRUMENTATION↗

Microwave Radiometer Profiler (MWRP) Instrument Handbook

The Microwave Radiometer Profiler (MWRP) provides time-series measurements of brightness temperatures from 12 channels between 22.235 and 58.80 GHz. These channels are sensitive to the presence of liquid water and precipitable water vapor and to the atmospheric temperature and humidity profile.

47 OTHER INSTRUMENTATION↗

Tower Camera (TWR CAM) Instrument Handbook

The NSA-C1 Utqiagvik tower camera is installed at a height of 40 meters above the ground at the topmost boom of the meteorological tower. The camera’s main field of view is directed at the tundra south of the tower, where the 10m Tip Tower is located. The camera captures images of the Tip Tower and the surrounding ground every 30 minutes. Since September 2017, the camera model is the AXIS Q6045-E Mk II PTZ Dome Network Camera. The tower camera images provide a qualitative look at the progression of the seasons at Utqiagvik. The tower camera images are useful for determining the fractional snow or vegetation cover. Additionally, the camera provides a glimpse of on-site weather conditions, showing the changing weather and/or ground conditions.

47 OTHER INSTRUMENTATION↗

Cryogenic Frostpoint Hygrometer (CFH) Instrument Handbook

The U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility’s Cryogenic Frostpoint Hygrometer (CFH) is a small, balloon-borne instrument that provides highly accurate measurements of water vapor in the atmosphere. The CFH, although highly modified, is based upon the National Oceanic and Atmospheric Administration (NOAA)/Climate Monitoring and Diagnostic Laboratory (CMDL) frostpoint hygrometer (FPH) that has been flown in Boulder, Colorado, since 1980. The CFH has a significantly greater sensitivity to water vapor than standard radiosondes, as it can measure the frostpoint or dewpoint temperatures at an accuracy better than 0.2 K corresponding to water volume mixing ratios accuracies of only a few parts per million. The main instrument part is a small mirror, which is cooled by a cryogen in order to be covered with a thin layer of water vapor condensate. A pair of photodiodes detects the condensation on the temperature-controlled mirror. The phase of the condensate is controlled by a force-freezing algorithm, allowing for clear interpretation of the dew point versus frostpoint. The replacement of analog electronics with a microprocessor, a feedback controller, and thermistor calibration have led to improved accuracy and performance of the CFH over its predecessors. Further characteristics like reduced power consumption and low instrument weight made the CFH a successful instrument to perform in situ balloon-borne measurements of water vapor in the upper troposphere and lower stratosphere. CFH measurements are now used worldwide to validate radiosonde, satellite, and ground-based profiler measurements.

47 OTHER INSTRUMENTATION↗

Solar Infrared Radiation Station (SIRS), Sky Radiation (SKYRAD), Ground Radiation (GNDRAD), and Broadband Radiometer Station (BRS) Instrument Handbook

The solar infrared radiation station (SIRS), ground radiometers on stand for upwelling radiation (GNDRAD), and sky radiometers on stand for downwelling radiation (SKYRAD) provide continuous measurements of broadband shortwave (solar) and longwave (atmospheric or infrared) irradiances for downwelling and upwelling components. The following six irradiance measurements are collected from a network of stations to help determine the total radiative flux exchange at each of the primary U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) field research sites—(Southern Great Plains [SGP], North Slope of Alaska [NSA)]and Eastern North Atlantic [ENA])—as well as the ARM mobile facilities (AMF): Direct normal shortwave (solar beam), Diffuse horizontal shortwave (sky), Global horizontal shortwave (total hemispheric), Upwelling shortwave (reflected), Downwelling longwave (atmospheric infrared), Upwelling longwave (surface infrared).

54 ENVIRONMENTAL SCIENCES↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of the surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) (and methane at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility’s North Slope of Alaska central facility [NSA Barrow], and at the ARM Mobile Facility (AMF) deployment at Oliktok Point). The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration. The instruments used are: a fast-response, three-dimensional (3D) wind sensor (sonic anemometer) to obtain the orthogonal wind components and the speed of sound (SOS) (used to derive the air temperature), an open-path infrared gas analyzer (IRGA) to obtain the water vapor density and the CO 2 concentration, and an open-path infrared gas analyzer (IRGA) to obtain methane density and methane flux at NSA Barrow and at the AMF deployment at Oliktok Point. The ECOR systems are deployed at the locations where other methods for surface flux measurements (e.g., energy balance Bowen ratio [EBBR] systems) are difficult to employ, primarily at the north edge of a field of crops. A surface energy balance system (SEBS) has been installed collocated with each deployed ECOR system in SGP, NSA, Tropical Western Pacific (TWP), and each of three ARM Mobile Facilities. The surface energy balance system consists of upwelling and downwelling solar and infrared radiometers within one net radiometer, a wetness sensor, and soil measurements. Finally, the SEBS measurements allow the comparison of ECOR sensible and latent heat fluxes with the energy balance determined from the SEBS and provide information on wetting of the sensors for data quality purposes.

47 OTHER INSTRUMENTATION↗

Issue Update to LWR SiC/SiC Cladding Handbook of Properties

This report aims to provide properties data of silicon carbide (SiC) fiber–reinforced SiC matrix (SiC/SiC) composites for use in modeling for their application as accident-tolerant fuel cladding for light water reactors (LWRs). The properties data presented are specifically for geometries relevant to fuel cladding tubes, although many properties can be derived or predicted based on data from planar geometry specimen data. This report presents various properties, including mechanical properties, thermal properties, chemical stability under normal and off-normal operation conditions, hermeticity, and irradiation resistance. Table S.1 provides a high level summary of those properties mainly for nuclear-grade SiC/SiC composites fabricated via a chemical vapor infiltration (CVI) route, which has been updated from the previous report (ORNL/TM - 2017/385). The newly added data include statistical tensile properties, hydrothermal corrosion behavior of environmental barrier coating on SiC, and accurate temperature- and dose-dependent swelling of SiC/SiC composites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Carbon Monoxide Analyzer (CO-ANALYZER) Instrument Handbook

The N 2 O/CO analyzer uses LGR’s patented Off-axis ICOS technology, which employs a high-finesse optical cavity as the measurement cell. LGR’s technology has many proven advantages over conventional first-generation cavity ringdown spectroscopy (CRDS) techniques. In brief, since the laser beam does not have to be resonantly coupled to the measurement cell, precise beam alignment is not critical. Mentors can disassemble the cell for cleaning (CAREFULLY) the front surface mirrors. Analyzers are relatively inexpensive and inherently robust thermally and mechanically. In addition, since LGR’s technology can record reliable absorption spectra over a far wider range of optical depths (absorbance values) than CRDS, LGR analyzers provide measurements over a much wider range of mixing ratios (gas concentrations). The N 2 O/CO analyzer includes an internal computer that sends real-time data to the local instrument computer through its digital (RS-232) output.

47 OTHER INSTRUMENTATION↗

Pu Handbook Chapter 39: Thermophysical Property Measurements

The ability to carry out thermophysical property measurements on actinide materials is very important for complete characterization. This is especially true of plutonium and plutonium containing materials where many questions still remain surrounding its physics. Over the past decade, there have been numerous examples of interesting physical behavior in many of these flux grown crystals and prepared alloys including unconventional superconductivity, complex magnetism, paramagnetism, and radiation damage or aging studies. In all of these cases, data was obtained that include the measurement of magnetic susceptibility, heat capacity, or electrical resistivity as well as other property measurements. These have allowed more detailed study of the dual nature of the 5$f$ electrons of plutonium in a variety of crystal structures and coordination environments. The alpha-particle radioactivity of plutonium provides an additional challenge to collecting data from the materials in a safe and effective way. It is therefore very important that the experimentalist is able to obtain high quality data while keeping the measurement system as well as the sample holder free of any radioactive contamination that may spread during the measurement process. In this section, the most widely used techniques for characterization of the synthesized material will be described. These include the physical property methods of magnetic susceptibility, heat capacity, and electrical resistivity as well as a few others.

36 MATERIALS SCIENCE↗

Condensation Particle Counter (CPC) Instrument Handbook - Airborne Version

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Model 3772 condensation particle counter (CPC) is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high-concentration measurements, such as basic aerosol research, filter and air cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

54 ENVIRONMENTAL SCIENCES↗

Weighing Bucket Rain Gauge Instrument Handbook

The OTT precipitation gauge is used for automatic determination of the intensity and amount of precipitation. In contrast to conventional precipitation gauges, the Pluvio2 works using the balance principle. The gauge reliably recognizes precipitation by determining the weight of the collecting bucket. A high-precision stainless steel load cell, hermetically sealed against environmental influences, is used as the sensor element. An integrated temperature sensor compensates for the temperature changes in the weighing mechanism. These sensors have been found to be stable for years. The orifice of the gauge is heated and when snow/ice precipitation occurs, the weight of its water equivalent is the amount observed.

42 ENGINEERING↗