At least 523 records · Page 29

Technology Demonstrator of an Americium-Fuelled Radioisotope Stirling Generator

Americium-241 is used as the fuel of choice in European Radioisotope Power Systems. The University of Leicester have developed a number of systems using this fuel type, including a 200 Wth heat source. To maximise the electrical output that can be generated from the heat source, the University of Leicester and NASA Glenn Research Center have collaborated on a radioisotope Stirling generator concept, building on the long heritage of dynamic power conversion developments at NASA GRC. Here we present the design of a technology demonstrator of the Americium-fuelled Radioisotope Stirling Generator (Am-RSG).

Americium-241↗

Design criteria for and applications of the vortex generator mixing principal

There are at this date numerable projects, in various Divisions of U.A.C., either in progress or contemplated, which are employing the vortex generator mixing principle. This principle is defined as the method which utilises tip vortices generated by low aspect ratio airfoils for the purpose of transverse mixing of the flow of a confined fluid medium where the axis of the vortex is parallel to the direction of flow. To date, vortex generator design criteria have not been published. Therefore, for the assistance of those individuals concerned and in the interest of the vortex mixing principle, the following material (subject to modifications) is presented in this memorandum report.

H D Taylor↗

Magnetohydrodynamic generators using two-phase liquid-metal flows

Two-phase flow generator cycle of a magnetohydrodynamic /MHD/ generator uses a working fluid which is compressible and treated as an expanding gas. The two-phase mixture passes from the heat source through the MHD generator, where the expansion process takes place and the electrical energy is extracted.

Petrick, M.↗

Internal and ancestral controls of cell-generation times

Lateral and longitudinal correlations between related cells reveal associations between the generation times of cells for an intermediate period /three generations in bacteral cultures/. Generation times of progeny are influenced by nongenetic factors transmitted from their ancestors.

Kubitschek, H. E.↗

Long-life electromechanical sine-cosine generator

Sine-cosine generator with no sliding parts is capable of withstanding a 20 Hz oscillation for more than 14 hours. Tests show that generator is electrically equal to potentiometer and that it has excellent dynamic characteristics. Generator shows promise of higher-speed applications than was previously possible.

Flagge, B.↗

Uniform random number generators

Methods are presented for the generation of random numbers with uniform and normal distributions. Subprogram listings of Fortran generators for the Univac 1108, SDS 930, and CDC 3200 digital computers are also included. The generators are of the mixed multiplicative type, and the mathematical method employed is that of Marsaglia and Bray.

Farr, W. R.↗

Large-scale terrestrial solar cell power generation cost: A preliminary assessment

A cost study was made to assess the potential of the large-scale use of solar cell power for terrestrial applications. The incentive is the attraction of a zero-pollution source of power for wide-scale use. Unlike many other concepts for low-pollution power generation, even thermal pollution is avoided since only the incident solar flux is utilized. To provide a basis for comparison and a perspective for evaluation, the pertinent technology was treated in two categories: current and optimistic. Factors considered were solar cells, array assembly, power conditioning, site preparation, buildings, maintenance, and operation. The capital investment was assumed to be amortized over 30 years. The useful life of the solar cell array was assumed to be 10 years, and the cases of zero and 50-percent performance deg-radation were considered. Land costs, taxes, and profits were not included in this study because it was found too difficult to provide good generalized estimates of these items. On the basis of the factors considered, it is shown that even for optimistic projections of technology, electric power from large-sclae terrestrial use of solar cells is approximately two to three orders of magnitude more costly than current electric power generation from either fossil or nuclear fuel powerplants. For solar cell power generation to be a viable competitor on a cost basis, technological breakthroughs would be required in both solar cell and array fabrication and in site preparation.

Spakowski, A. E.↗

Hall current effects in the Lewis magnetohydrodynamic generator

Data obtained in a magnetohydrodynamic generator are compared with theoretical values calculated by using the Dzung theory. The generator was operated with cesium-seeded argon as the working fluid. The gas temperature varied from 1800 to 2100 K, the gas pressure from 19 to 22 N/sq cm, the Mach number from 0.3 to 0.5, and the magnetic field strength from 0.2 to 1.6 T. The analysis indicates that there is incomplete seed vaporization and that Hall current shorting paths (through the working fluid to ground at both the entrance and exit of the channel) limit generator performance.

Nichols, L. D.↗

Logical-function generator

Apparatus and technique for generating logical functions and circuits have been developed. They provide aid in designing and constructing hardware to generate logic circuits, by defining circuit connections required to generate these functions. With this method, it is possible quickly and automatically to design logic, while eliminating involved and time-consuming mathematical manipulations.

Sivertson, W. E., Jr.↗

Supplementary notes on sea surface temperature anomalies and model-generated meteorological histories

In seasonal computations, the Mintz-Arakawa two-level model is found to be sensitive to a minor alteration in the computational program. Effects of the program change on monthly mean sea level pressure fields are small in the first month, but large in the second and third months, although the meteorological histories generated by both the original and modified programs are equally credible. The inherited effects of a transient (one month) sea surface temperature (SST) anomaly on the computed monthly mean sea level pressure fields over a period of a season are about as large in absolute magnitude as those generated in the model by a persistent (seasonal) SST anomaly. The effects of a transient SST anomaly in the North Pacific Ocean on monthly and seasonal temperature and precipitation in the eastern United States may be large enough to produce a change of one or two class intervals in these predicted weather elements. The model-generated precipitation in the equatorial region is also found to be sensitive to the sea surface temperature field in the North Pacific.

Spar, J.↗

Properties of cirrus generating cells.

Particle size spectra were measured during 20 hr of sampling in cirrus generating cells (uncinus, stratus, spissatus, thunderstorm anvil) and the particle concentration, mean crystal length, ice water content, reflectivity factor, and precipitation rate were calculated from these spectra. Average values of the physical properties in the generating cells were obtained. Growth was found to be downward, reaching a maximum ice water content just below the base of the generating cell. The maximum ice water contents (not including the thunderstorm anvil) were found in cirrus uncinus. Liquid water was not found throughout the cirrus sampling by measurement with the Johnson-Williams hot-wire liquid-water meter; however, it is believed that liquid water is present as a transient phase.

Heymsfield, A. J.↗

Hall current effects in the Lewis magnetohydrodynamic generator.

Data obtained in the Lewis MHD generator are compared with theoretical values calculated using the Dzung (1966) theory. The generator is operated with cesium seeded argon as the working fluid. The gas temperature varies from 1800 to 2100 K, the gas pressure from 19 to 22 N/sq cm, the Mach number from .3 to .5, and the magnetic field strength from .2 to 1.6 tesla. The analysis indicates that there is incomplete seed vaporization and that Hall current shorting paths (through the working fluid to ground at both the entrance and exit of the channel) are limiting generator performance.

Nichols, L. D.↗

Logarithmic-function generator

Solid-state logarithmic-function generator is compact and provides improved accuracy. Generator includes a stable multivibrator feeding into RC circuit. Resulting exponentially decaying voltage is compared with input signal. Generator output is proportional to time required for exponential voltage to decay from preset reference level to level of input signal.

Caron, P. R.↗

A method of billing third generation computer users

A method is presented for charging users for the processing of their applications on third generation digital computer systems is presented. For background purposes, problems and goals in billing on third generation systems are discussed. Detailed formulas are derived based on expected utilization and computer component cost. These formulas are then applied to a specific computer system (UNIVAC 1108). The method, although possessing some weaknesses, is presented as a definite improvement over use of second generation billing methods.

Anderson, P. N.↗

Development of an iodine generator for reclaimed water purification in manned spacecraft applications

A successful 30-day test is described of a prototype Iodine Generating and Dispensing System (IGDS). The IGDS was sized to iodinate the drinking water nominally consumed by six men, 4.5 to 13.6 kg (10 to 30 lb) water per man-day with a + or - 10 to 20% variation with iodine (I2) levels of 0.5 to 20 parts per million (ppm). The I2 treats reclaimed water to prevent or eliminate microorganism contamination. Treatment is maintained with a residual of I2 within the manned spacecraft water supply. A simplified version of the chlorogen water disinfection concept, developed by life systems for on-site generation of chlorine (Cl2), was used as a basis for IGDS development. Potable water contaminated with abundant E. Coliform Group organisms was treated by electrolytically generated I2 at levels of 5 to 10 ppm. In all instances, the E. coli were eliminated.

Wynveen, R. A.↗

Electronic power generators for ultrasonic frequencies

The design and construction of an ultrasonic frequency electronic power generator are discussed. The principle design elements of the generator are illustrated. The generator provides an inductive load with an output power of two kilowatts and a variable output frequency in the fifteen to thirty KiloHertz range. The method of conducting the tests and the results obtained with selected materials are analyzed.

Ciovica, D.↗

Low frost-point humidity generator

A low frost-point humidity generator has been developed at NBS to provide a capability for calibration, testing, and research at very low levels of water vapor content in such gases as atmospheric air, carbon dioxide and nitrogen. The generator produces frost points from -30 to -100 C at ambient pressures from 500 to 200,000 pascals (0.005 to 2 atm.). This is equivalent to mixing ratios of 4 micrograms to 51 grams of water vapor per kilogram of dry air and to vapor pressures of .0014 to 38 pascals. The generated test gas can be fed to a test chamber with independent temperature control between +25 and -100 C. The uncertainty of the frost point in the test chamber is estimated not to exceed 0.05 deg C.

Greenspan, L.↗