Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Optimizing aluminum oxide passivation layers—Laser-induced plasmas for layer formation, real-time diagnostics, and layer evaluation

Molten salts have beneficial thermophysical and electrolytic properties, but the aggressive nature of molten salts requires corrosion mitigation strategies, such as structural material surface treatment. In this study, a laser-induced breakdown spectroscopy (LIBS) system was used to simultaneously ablate and monitor de-excitation spectra to form and identify dense alumina passivation layers. Additionally, high-frequency (kHz) LIBS imaging allowed rapid elemental mapping and depth profiling for surface O/Al ratios via minimally destructive analysis. The paired t-test rejected the null hypothesis that air and Ar cover gases were equivalent (p = 0.00012), and the analysis of variance (ANOVA) showed that overlap between shots (p = 0.03112) and cover gas flow rate (p = 0.02729) were statistically significant. At 75% overlap, the O/Al ratio increased to 10% ± 2%, and 90% overlap rose further to 31% ± 2%. Regardless of overlap, tuning the gas flow from 0.5 to 2.5 L min −1 enhanced the O/Al ratio by 24% ± 4%. LIBS depth profiling showed a 3× increase in layer thickness from 75% to 90% overlap. Molecular band peaks of AlO, a precursor to Al 2 O 3 found during treatment, suggest that band intensity could be used for real-time Al 2 O 3 optimization. Ultimately, by adjusting laser spot overlap and cover gas flow rate, a 266 nm laser was shown to form Al 2 O 3 layers on an Al6061 sample, with cover gas flow rate primarily affecting the O/Al ratio and layer thickness correlating with laser spot overlap. This combination of molecular spectra collection, imaging, and depth profiling demonstrated the robust layer analysis capabilities of LIBS.

Corrosion↗

CO2 Washout Testing of the REI and EM-ACES Space Suits

When a space suit is used during ground testing, adequate carbon dioxide (CO2) washout must be provided for the suited subject. Symptoms of acute CO2 exposure depend on partial pressure of CO2 (ppCO2), metabolic rate of the subject, and other factors. This test was done to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) for a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of about 500 to 3000 BTU/hr. Supply airflow was varied between 6, 5, and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored in real time by gas analyzers with sampling tubes connected to the mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the suit air outlet. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was affected mainly by the metabolic rate of the subject: increased metabolic rate significantly (P < 0.05) increased inspired ppCO2. Decreased air flow caused small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates . 2000 BTU/hr. CO2 washout values of the EM-ACES were slightly but not significantly better than those of the REI suit. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology, and results as well as implications for future ground testing in the REI-suit and EM-ACES.

Mitchell, Kathryn C.↗

Carbon Dioxide Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy, and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject, and physiological differences between subjects. Computational Fluid Dynamics (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit, and the Enhanced Mobility Advanced Crew Escape Suit. Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

CO2 Washout Testing of the REI and EM-ACES Space Suits

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. The objective of this test was to characterize inspired oronasal ppCO2 in the Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES) across a range of workloads and flow rates for which ground testing is nominally performed. Three subjects were tested in each suit. In all but one case, each subject performed the test twice to allow for comparison between tests. Suit pressure was maintained at 4.3 psid. Subjects wore the suit while resting, performing arm ergometry, and walking on a treadmill to generate metabolic workloads of approximately 500 to 3000 BTU/hr. Supply airflow was varied at 6, 5 and 4 actual cubic feet per minute (ACFM) at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total CO2 production measured by an additional gas analyzer at the air outlet from the suit. Real-time metabolic rate was used to adjust the arm ergometer or treadmill workload to meet target metabolic rates. In both suits, inspired CO2 was primarily affected by the metabolic rate of the subject, with increased metabolic rate resulting in increased inspired ppCO2. Suit flow rate also affected inspired ppCO2, with decreased flow causing small increases in inspired ppCO2. The effect of flow was more evident at metabolic rates greater than or equal to 2000 BTU/hr. Results were consistent between suits, with the EM-ACES demonstrating slightly better CO2 washout than the REI suit, but not statistically significant. Regression equations were developed for each suit to predict the mean inspired ppCO2 as a function of metabolic rate and suit flow rate. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future ground testing in the REI and EM-ACES.

Mitchell, Kate↗

"Application of Tunable Diode Laser Spectrometry to Isotopic Studies for Exobiology"

Computer-controlled electrically-activated valves for rapid gas-handling have been incorporated into the Stable Isotope Laser Spectrometer (SILS) which now permits rapid filling and evacuating of the sample and reference gas cells, Experimental protocols have been developed to take advantage of the fast gas handling capabilities of the instrument and to achieve increased accuracy which results from reduced instrumental drift during rapid isotopic ratio measurements. Using these protocols' accuracies of 0.5 del (0.05%) have been achieved in measurements of 13C/12C in carbon dioxide. Using the small stable isotope laser spectrometer developed in a related PIDDP project of the Co-I, protocols for acquisition of rapid sequential calibration spectra were developed which resulted in 0.5 del accuracy also being achieved in this less complex instrument. An initial version of software for automatic characterization of tunable diode lasers has been developed and diodes have been characterized in order to establish their spectral output properties. A new state-of-the-art high operating temperature (200 K) mid infrared diode laser was purchased (through NASA procurement) and characterized. A thermo-electrically cooled mid infrared tunable diode laser system for use with high temperature operation lasers was developed. In addition to isotopic ratio measurements of carbon and oxygen, measurements of a third biologically important element (15N/14N in N2O gas) have been achieved to a preliminary accuracy of about 0.2%. Transfer of the basic SILS technology to the commercial sector is proceeding under an unfunded Space Act Agreement between NASA and SpiraMed, a medical diagnostic instrument company. Two patents have been issued. Foreign patents based on these two US patents have been applied for and are expected to be issued. A preliminary design was developed for a thermo-electrically cooled SILS instruments for application to planetary space flight exploration missions.

Sauke, Todd B.↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Realtime metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test was to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III suit across a range of workload and flow rates. Data and trends observed during testing along with refined CFD models will be used to help design an inlet vent configuration for the Z-2 space suit. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects performed two test sessions each in the Mark-III suit to allow for comparison between tests. Six different helmet inlet vent configurations were evaluated during each test session. Suit pressure was maintained at 4.3 psid. Suited test subjects walked on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) were tested at each workload. Subjects wore an oronasal mask with an open port in front of the mouth and were allowed to breathe freely. Oronasal ppCO2 was monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate was calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Real-time metabolic rate measurements were used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent designs and ground testing.

Korona, F. Adam↗

Milestone 2.8: Preliminary Radiolytic Gas Generation Measurements from Helium-Backfilled Samples

The Department of Energy (DOE) is currently managing nearly 13 metric tons of aluminum-clad spent nuclear fuel (ASNF) with the intention of extended (> 50 years) dry storage in helium-backfilled canisters. Due to in-reactor and cooling pond conditions, oxyhydroxide corrosion layers have formed on the surface of the ASNF elements. These corrosion layers are susceptible to radiolysis and the formation of molecular hydrogen gas (H 2 ) due to the fuel’s inherent radiation field. Consequently, a rigorous evaluation of the effect of helium gas on radiolytic H 2 production is necessary to support the Technical Considerations and Challenges for Extended (> 50 yrs) Dry Storage of ASNF program, especially as previous Task 2 - Oxyhydroxide Layer Radiolytic Gas Generation Resolution work demonstrated a significant effect of gas composition on the radiolytic yield (G-value) of H 2 . Here we report preliminary G-values for the radiolytic formation of H 2 from the gamma irradiation of pre-corroded aluminum alloy 1100 coupons flame sealed in helium environments. Irradiations yielded G(H 2 ) values of (5.1 ± 0.5) x 10 –4 and (9.4 ± 0.9) x 10 –4 µmol J –1 for pristine coupons, and (10.1 ± 0.4) x 10 –4 and (15.1 ± 1.2) x 10 –4 µmol J –1 for pre-corroded coupons for 0% and 50% relative humidity, respectively. These helium environment G(H 2 ) values are between 28% and 58% higher than previously reported values for argon environments. This enhancement is attributed to the significant difference in first ionization energy between helium (24.59 eV) and argon (15.76) facilitating additional processes, e.g., Penning ionization. These new preliminary helium environment G(H 2 ) values will be employed by Task 3 - Sealed and Vented System Episodic Breathing and Gas Generation Prediction to model the effect of radiolytic H 2 accumulation in helium environments to evaluate the practicality of the extended storage standard canister design.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CO2 Washout Testing Using Various Inlet Vent Configurations in the Mark-III Space Suit

Requirements for using a space suit during ground testing include providing adequate carbon dioxide (CO2) washout for the suited subject. Acute CO2 exposure can lead to symptoms including headache, dyspnea, lethargy and eventually unconsciousness or even death. Symptoms depend on several factors including inspired partial pressure of CO2 (ppCO2), duration of exposure, metabolic rate of the subject and physiological differences between subjects. Computational Fluid Dynamic (CFD) analysis has predicted that the configuration of the suit inlet vent has a significant effect on oronasal CO2 concentrations. The main objective of this test is to characterize inspired oronasal ppCO2 for a variety of inlet vent configurations in the Mark-III space suit across a range of workload and flow rates. As a secondary objective, results will be compared to the predicted CO2 concentrations and used to refine existing CFD models. These CFD models will then be used to help design an inlet vent configuration for the Z-2 space suit, which maximizes oronasal CO2 washout. This test has not been completed, but is planned for January 2014. The results of this test will be incorporated into this paper. The testing methodology used in this test builds upon past CO2 washout testing performed on the Z-1 suit, Rear Entry I-Suit (REI) and the Enhanced Mobility Advanced Crew Escape Suit (EM-ACES). Three subjects will be tested in the Mark-III space suit with each subject performing two test sessions to allow for comparison between tests. Six different helmet inlet vent configurations will be evaluated during each test session. Suit pressure will be maintained at 4.3 psid. Subjects will wear the suit while walking on a treadmill to generate metabolic workloads of approximately 2000 and 3000 BTU/hr. Supply airflow rates of 6 and 4 actual cubic feet per minute (ACFM) will be tested at each workload. Subjects will wear an oronasal mask with an open port in front of the mouth and will be allowed to breathe freely. Oronasal ppCO2 will be monitored real-time via gas analyzers with sampling tubes connected to the oronasal mask. Metabolic rate will be calculated from the total oxygen consumption and CO2 production measured by additional gas analyzers at the air outlet from the suit. Real-time metabolic rate measurements will be used to adjust the treadmill workload to meet target metabolic rates. This paper provides detailed descriptions of the test hardware, methodology and results, as well as implications for future inlet vent design and ground testing in the Mark-III.

Korona, F. Adam↗

Pressure Modulator Radiometer (PMR) tests

The pressure modulator technique was evaluated for monitoring pollutant gases in the Earth's atmosphere of altitude levels corresponding to the mid and lower troposphere. Using an experimental set up and a 110 cm sample cell, pressure modulator output signals resulting from a range of gas concentrations in the sample cell were examined. Then a 20 cm sample cell was modified so that trace gas properties in the atmosphere could be simulated in the laboratory. These gas properties were measured using an infrared sensor.

Odell, E. L. G.↗

Heterogeneous phase reactions of Martian volatiles with putative regolith minerals

The chemical reactivity of several minerals thought to be present in Martian fines is tested with respect to gases known in the Martian atmosphere. In these experiments, liquid water is excluded from the system, environmental temperatures are maintained below 0 C, and the solar illumination spectrum is stimulated in the visible and UV using a xenon arc lamp. Reactions are detected by mass spectrometric analysis of the gas phase over solid samples. No reactions were detected for Mars nominal gas over sulfates, nitrates, chloride, nontronite clay, or magnetite. Oxidation was not observed for basaltic glass, nontronite, and magnetite. However, experiments incorporating SO2 gas an expected product of volcanism and intrusive volatile release - gave positive results. Displacement of CO2 by SO2 occurred in all four carbonates tested. These reactions are catalyzed by irradiation with the solar simulator. A calcium nitrate hydrate released NO2 in the presence of SO2. These results have implications for the cycling of atmospheric CO2, H2O, and N2 through the regolith.

Clark, B. C.↗

Carbon-14 ages of Allan Hills meteorites and ice

Allan Hills is a blue ice region of approximately 100 sq km area in Antarctica where many meteorites have been found exposed on the ice. The terrestrial ages of the Allan Hills meteorites, which are obtained from their cosmogenic nuclide abundances are important time markers which can reflect the history of ice movement to the site. The principal purpose in studying the terrestrial ages of ALHA meteorites is to locate samples of ancient ice and analyze their trapped gas contents. Attention is given to the C-14 and Ar-39 terrestrial ages of ALHA meteorites, and C-14 ages and trapped gas compositions in ice samples. On the basis of the obtained C-14 terrestrial ages, and Cl-36 and Al-26 results reported by others, it is concluded that most ALHA meteorites fell between 20,000 and 200,000 years ago.

Fireman, E. L.↗

H2 Sensing with an Optical Fiber Sensor in the Subsurface H2 Storage Conditions

The concentration of hydrogen is subject to change due to biological reactions in the underground hydrogen storage reservoirs. Thus, monitoring hydrogen concentration in the subsurface gas deposits is vital to ensure the integrity and safety of the storage facilities. In this study, the optical fiber hydrogen sensor was developed and validated in relevant subsurface storage environments. Specifically, the sensor has demonstrated successful sensing performance at high temperatures (~80 °C) and high pressures (~1,000 psi) under very humid conditions (~100% RH). In addition, the sensor was exposed to real subsurface microbial samples to monitor microbially induced changes in hydrogen concentration. The sensor has shown stable H2 sensing responses in the replicated underground hydrogen storage conditions without deterioration or loss of H2 sensitivity. The biotic subsurface sample with hydrogen gas resulted in higher transmission intensity change than the abiotic sample due to the possible hydrogen consumption with microbes.

Kim, Daejin↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Procedure for preparation for shipment of natural gas storage vessel

A method for preparing a natural gas storage vessel for shipment is presented. The gas is stored at 3,000 pounds per square inch. The safety precautions to be observed are emphasized. The equipment and process for purging the tank and sampling the exit gas flow are described. A diagram of the pressure vessel and the equipment is provided.

Amawd, A. M.↗

Overview of the Results of the Organics PET Study of the Cometary Samples from Comet Wild 2 by the Stardust Mission

STARDUST is the first mission designed to bring samples back to Earth from a known comet. The captured samples were successfully returned to Earth on 15 Jan 2006, after which they were subjected to a preliminary examination by a number of teams of scientists from around the world. This abstract describes the efforts of the Organics Preliminary Examination Team (PET). More detailed discussions of specific analyses of the samples can be found in other papers presented at this meeting by individual members of the Organics PET (see the author list above for team members). The studied Wild 2 gas and dust samples were collected by impact onto aerogel tiles and Al foils when the spacecraft flew through the coma of 81P/Wild 2 on 2 Jan 2004 at a relative velocity of approx.6.1 kilometers per second. After recovery of the Sample Return Capsule (SRC) on 15 Jan 2006, the aerogel collector trays were removed in a clean room at JSC. After documentation of the collection, selected aerogel tiles and aluminum foils were removed and aerogel and cometary samples extracted for study.

Sandford, S. A.↗

Burning of CP Titanium (Grade 2) in Oxygen-Enriched Atmospheres

The flammability in oxygen-enriched atmospheres of commercially pure (CP) titanium rods as a function of diameter and test gas pressure was determined. Test samples of varying diameters were ignited at the bottom and burned upward in 70% O2/balance N2 and in 99.5+% O2 at various pressures. The burning rate of each ignited sample was determined by observing the apparent regression rate of the melting interface (RRMI) of the burning samples. The burning rate or RRMI increased with decreasing test sample diameter and with increasing test gas pressure and oxygen concentration

Stoltzfus, Joel M.↗