Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Functionally graded materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

X-Ray Diffraction of Slag-Based Sodium Salt Waste Forms

Cementitious materials are used to solidify and stabilize aqueous based radioactive waste containing sodium salts. The types and proportions of cementitious ingredients used to treat aqueous radioactive waste streams containing sodium salts depend on the performance objectives for the waste forms and the compositions of the waste streams. Matrix phases can stabilize certain contaminants (co-precipitation, substitution, ion exchange, and / or sorption), influence processing properties, and are responsible for physical properties and durability of the cured waste forms. Consequently, characterization of the matrix (binder) mineralogy (chemical compositions and crystalline / non crystalline structures) is important for predicting contaminant leaching and evolution of the materials as a function of time and changing conditions This report documents sample preparation and x-ray diffraction results for a series of mixtures of sodium salt waste and cementitious binders. The objective of this study was to provide initial phase characterization for the CBP reference case cementitious salt waste form. This information can be used to: 1) generate a base line for the evolution of the waste form as a function of time and conditions, 2) potentially to design new binders based on mineralogy of the binder, 3) understand and predict anion and cation leaching behavior of contaminants of concern, and 4) predict performance of the waste forms for which phase solubility and thermodynamic data are available. Characterization of the mineralogy is also important for understanding the buffering effects that the waste form has on infiltrating water / leachates. More specifically, identification of hydrated phases capable of sequestering anions in the structures and crystallinity of the calcium silicate binder phases were of particular interest. The intent was to use this characterization data as a starting point for more detailed phase characterization using neutron diffraction techniques in addition to quasi-elastic neutron scattering techniques for characterization of water at the ORNL Spallation Neutron Source, Oak Ridge, TN. The initial characterization is complete. Due to extensive substitutions of cations and anions in the layered double hydroxide phases and the very fine intermixing of poorly crystalline hydrated phases in the reference case blend (10 : 45 : 45 cement : slag : fly ash), electron diffraction and transmission electron spectroscopy are recommended as the next step for characterization. In summary, the hydrated mixtures of Type II portland cement, Grade 100 ground granulated blast furnace slag (GGBFS) and carbon burn-out (CBO) Class F Fly ash contained hydrated phase assemblages which were typical of those reported in the literature. Based on x-ray diffraction results, no significant differences were detected in samples cured 2 months and 14 months in sealed containers at ambient indoor temperatures.

36 MATERIALS SCIENCE↗

Individualized Radical Radiotherapy of Non-Small-Cell Lung Cancer Based on Normal Tissue Dose Constraints: A Feasibility Study

Purpose: Local recurrence is a major problem after (chemo-)radiation for non-small-cell lung cancer. We hypothesized that for each individual patient, the highest therapeutic ratio could be achieved by increasing total tumor dose (TTD) to the limits of normal tissues, delivered within 5 weeks. We report first results of a prospective feasibility trial. Methods and Materials: Twenty-eight patients with medically inoperable or locally advanced non-small-cell lung cancer, World Health Organization performance score of 0-1, and reasonable lung function (forced expiratory volume in 1 second > 50%) were analyzed. All patients underwent irradiation using an individualized prescribed TTD based on normal tissue dose constraints (mean lung dose, 19 Gy; maximal spinal cord dose, 54 Gy) up to a maximal TTD of 79.2 Gy in 1.8-Gy fractions twice daily. No concurrent chemoradiation was administered. Toxicity was scored using the Common Terminology Criteria for Adverse Events criteria. An {sup 18}F-fluoro-2-deoxy-glucose-positron emission tomography-computed tomography scan was performed to evaluate (metabolic) response 3 months after treatment. Results: Mean delivered dose was 63.0 {+-} 9.8 Gy. The TTD was most often limited by the mean lung dose (32.1%) or spinal cord (28.6%). Acute toxicity generally was mild; only 1 patient experienced Grade 3 cough and 1 patient experienced Grade 3 dysphagia. One patient (3.6%) died of pneumonitis. For late toxicity, 2 patients (7.7%) had Grade 3 cough or dyspnea; none had severe dysphagia. Complete metabolic response was obtained in 44% (11 of 26 patients). With a median follow-up of 13 months, median overall survival was 19.6 months, with a 1-year survival rate of 57.1%. Conclusions: Individualized maximal tolerable dose irradiation based on normal tissue dose constraints is feasible, and initial results are promising.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of local-power-free, remote α -particle detection using optical fibers

We demonstrate the application of fluorescence optical fiber coupled to a telecom grade fiber as a sensor for alpha particles using alpha-specific ZnS(Ag) scintillation materials whose wavelength is down-shifted into a low-loss region of the telecom grade fiber transmission band. Telecom-grade fiber optics offer a solution for sensing alpha radiation in deep repositories and cask storage for radioactive materials due to the stability of SiO 2 under normal environmental conditions and its relative radiation hardness at low radiation doses. Long-term nuclear waste storage facilities require sensors for the detection of leakage of radioactive materials that are maintenance-free, do not require power and can survive with no ‘wear out’ mechanisms for decades. By accomplishing the wavelength transformation, we maximize efficiencies in the detection of α-particles and signal transport and can detect alpha scintillation at distances on the order of >1 km with a sensor that is ~3% efficient and can be easily scaled as a sensor array. This paper describes the construction and testing of the sensor including manufacture of the controlled thickness films, verification of the wavelength shift from 450 to 620 nm and optimization of the sensitivity as a function of thickness. We also model the relative sensitivity of the film as a function of film thickness, and we demonstrate a signal-to-noise ratio of 10 at a range of greater than 1 km.

alpha particles↗

MAR flow mapping of Analytical Chemistry Operations (Preliminary Report)

The recently released Supplemental Directive, NA-1 SD 1027, updates the radionuclide threshold values in DOE-STD-1027-92 CN1 to reflect the use of modern parameters for dose conversion factors and breathing rates. The directive also corrects several arithmetic errors within the original standard. The result is a roughly four-fold increase in the amount of weapons-grade nuclear material allowed within a designated radiological facility. Radiological laboratory space within the recently constructed Radiological Laboratory Office and Utility Building (RLUOB) is slated to house selected analytical chemistry support activities in addition to small-scale actinide R&D activities. RLUOB is within the same facility operations envelope as TA-55. Consolidation of analytical chemistry activities to RLUOB and PF-4 offers operational efficiency improvements relative to the current pre-CMRR plans of dividing these activities between RLUOB, PF-4, and CMR. RLUOB is considered a Radiological Facility under STD-1027 - 'Facilities that do not meet or exceed Category 3 threshold criteria but still possess some amount of radioactive material may be considered Radiological Facilities.' The supplemental directive essentially increases the allowable material-at-risk (MAR) within radiological facilities from 8.4 g to 38.6 g for 239 Pu. This increase in allowable MAR provides a unique opportunity to establish additional analytical chemistry support functions in RLUOB without negatively impacting either R&D activities or facility operations. Individual radiological facilities are tasked to determine MAR limits (up to the Category 3 thresholds) appropriate to their operational conditions. This study presents parameters that impact establishing MAR limits for RLUOB and an assessment of how various analytical chemistry support functions could operate within the established MAR limits.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiochemotherapy With Cetuximab, Cisplatin, and Amifostine for Locally Advanced Head and Neck Cancer: A Feasibility Study

Purpose: Radiotherapy (RT) combined with cisplatin or cetuximab is the standard of care for patients with locally advanced head/neck cancer (LA-HNC). The feasibility of radiochemotherapy with cisplatin and cetuximab, supported with amifostine, was herein investigated. Methods and Materials: Forty-three patients with LA-HNC were recruited. Conformal hypofractionated/accelerated RT with amifostine cytoprotection (2.7 Gy/fraction, 21 fractions in 4 weeks) was combined with cisplatin (30 mg/m{sup 2}/week) and cetuximab (standard weekly regimen) therapy. The dose of amifostine was individualized according to tolerance. Results: A high daily amifostine dose (750-1,000 mg) was tolerated by 41.8% of patients, and a standard dose (500 mg) was tolerated by 34.9% of patients. A high amifostine dose was linked to reduced RT delays (p = 0.0003). Grade 3 to 4 (3-4) mucositis occurred in 7/43 (16.2%) patients, and fungal infections occurred in 18/43 (41.8%) patients. Radiation dermatitis was not aggravated. Interruption of cetuximab due to acneiform rash was necessary in 23.3% of patients, while amifostine-related fever and rash were not observed. Severe late radiation sequelae consisted of laryngeal edema (9% laryngeal cases) and cervical strictures (33% of hypopharyngeal cases). Good salivary function was preserved in 6/11 (54.5%) nasopharyngeal cancer patients. The complete response rate was 68.5%, reaching 77.2% in patients with minor radiotherapy delays. The 24-month local control and survival rates were 72.3% and 91%, respectively (median follow-up was 13 months.). Conclusions: In this feasibility study, weekly administration of cisplatin and cetuximab was safely combined with accelerated RT, supported with amifostine, at the cost of a high incidence of acneiform rash but a reduced incidence of amifostine-related fever/rash. A high daily dose of amifostine allows completion of therapy with minor delays.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality of Life After Stereotactic Radiotherapy for Stage I Non-Small-Cell Lung Cancer

Purpose: To determine the impact of stereotactic radiotherapy on the quality of life of patients with inoperable early-stage non-small-cell lung cancer (NSCLC). Overall survival, local tumor control, and toxicity were also evaluated in this prospective study. Methods and Materials: From January 2006 to February 2008, quality of life, overall survival, and local tumor control were assessed in 39 patients with pathologically confirmed T1 to 2N0M0 NSCLC. These patients were treated with stereotactic radiotherapy. The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ) C30 and the QLQ LC13 lung cancer-specific questionnaire were used to investigate changes in quality of life. Assessments were done before treatment, at 3 weeks, and at 2, 4, 6, 9, and 12 months after treatment, until death or progressive disease. Toxicity was evaluated using common terminology criteria for adverse events version 3.0. Results: Emotional functioning improved significantly after treatment. Other function scores and QLQ C30 and QLQ LC13 lung symptoms (such as dyspnea and coughing) showed no significant changes. The overall 2-year survival rate was 62%. After a median follow-up of 17 months, 1 patient had a local recurrence (3%). No grade 4 or 5 treatment-related toxicity occurred. Grade 3 toxicity consisted of thoracic pain, which occurred in 1 patient within 4 months of treatment, while it occurred thereafter in 2 patients. Conclusions: Quality of life was maintained, and emotional functioning improved significantly after stereotactic radiotherapy for stage I NSCLC, while survival was acceptable, local tumor control was high, and toxicity was low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Clinical Outcome of Intensity-Modulated Radiotherapy for Inoperable Non-Small Cell Lung Cancer: The MD Anderson Experience

Purpose: In 2007, we published our initial experience in treating inoperable non-small-cell lung cancer (NSCLC) with intensity-modulated radiation therapy (IMRT). The current report is an update of that experience with long-term follow-up. Methods and Materials: Patients in this retrospective review were 165 patients who began definitive radiotherapy, with or without chemotherapy, for newly diagnosed, pathologically confirmed NSCLC to a dose of {>=}60 Gy from 2005 to 2006. Early and late toxicities assessed included treatment-related pneumonitis (TRP), pulmonary fibrosis, esophagitis, and esophageal stricture, scored mainly according to the Common Terminology Criteria for Adverse Events 3.0. Other variables monitored were radiation-associated dermatitis and changes in body weight and Karnofsky performance status. The Kaplan-Meier method was used to compute survival and freedom from radiation-related acute and late toxicities as a function of time. Results: Most patients (89%) had Stage III to IV disease. The median radiation dose was 66 Gy given in 33 fractions (range, 60-76 Gy, 1.8-2.3 Gy per fraction). Median overall survival time was 1.8 years; the 2-year and 3-year overall survival rates were 46% and 30%. Rates of Grade {>=}3 maximum TRP (TRP{sub max}) were 11% at 6 months and 14% at 12 months. At 18 months, 86% of patients had developed Grade {>=}1 maximum pulmonary fibrosis (pulmonary fibrosis{sub max}) and 7% Grade {>=}2 pulmonary fibrosis{sub max}. The median times to maximum esophagitis (esophagitis{sub max}) were 3 weeks (range, 1-13 weeks) for Grade 2 and 6 weeks (range, 3-13 weeks) for Grade 3. A higher percentage of patients who experienced Grade 3 esophagitis{sub max} later developed Grade 2 to 3 esophageal stricture. Conclusions: In our experience, using IMRT to treat NSCLC leads to low rates of pulmonary and esophageal toxicity, and favorable clinical outcomes in terms of survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute Toxicity in Definitive Versus Postprostatectomy Image-Guided Radiotherapy for Prostate Cancer

Purpose: To assess the incidence of acute gastrointestinal (GI) and genitourinary (GU) injury and the dose-volume response in patients with clinically localized prostate cancer treated with image-guided radiotherapy using helical tomotherapy. Methods and Materials: Between November 2004 and March 2007, 146 consecutive patients with localized prostate cancer were treated with helical tomotherapy at the City of Hope Medical Center. Of the 146 patients, 70 had undergone prostatectomy. Acute GI and GU toxicities were evaluated using the Radiation Therapy Oncology Group/European Organization for Research and Cancer of Medical scoring system. Events were scored for patients developing Grade 2 or greater morbidity within 90 days after the end of radiotherapy (RT). The dosimetric parameters included the minimal dose received by the highest 10%, 20%, 50%, 80%, and 90% of the target volume, the mean rectal dose, minimal rectal dose, maximal rectal dose, and the volume receiving {>=}45, {>=}65, and {>=}70 Gy. These variables, plus the status of radical prostatectomy, hormonal therapy, RT techniques, and medical conditions, were included in a multivariate logistic regression analysis. A goodness-of-fit evaluation was done using the Hosmer-Lemeshow statistic. Results: A dose-response function for acute GI toxicity was elicited. The acute GI Grade 2 or greater toxicity was lower in the definitive RT group than in the postoperative RT group (25% vs. 41%, p <0.05). Acute GU Grade 2 or greater toxicity was comparable between the two groups. No grade 3 or greater complications were observed. No dosimetric variable was significant for GU toxicity. For acute GI toxicity, the significant dosimetric parameters were the minimal dose received by 10%, 20%, and 50% of the target volume and the mean rectal dose; the most predictive parameter was the minimal dose received by 10% of the target volume. The dose-modifying factor was 1.2 for radical prostatectomy. Conclusion: The results of our study have shown that acute rectal symptoms are dose-volume related. Postprostatectomy RT resulted in a greater incidence of acute GI toxicity than did definitive RT. For postoperative RT, it would be prudent to use different dose-volume limits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tailoring Corrosion Resistance of Additively Manufactured Metals with Atomic Layer Deposition

The goal of this work is to develop a scalable post-manufacturing capability at LANL that utilizes atomic layer deposition (ALD) for corrosion-resistant coatings onto additively manufactured (AM) metals. This will provide fundamentally new and essential capabilities towards the interchangeability of AM metals with traditionally wrought or machined material. This will be accomplished by (1) formulating novel ALD precursor doses and film thicknesses onto as-printed coupons of AM metals and (2) providing electrochemical characterization of corrosion susceptibility as a function of deposited film thickness. While ALD is well-established, the unique aspect (risk) of this work is application to rough AM surfaces. This risk is mitigated by repeating ALD deposition cycles, where thicker coatings laterally branch, resulting in a uniform coating. This risk will be assessed in the phase 1 feasibility study, wherein the application of ALD coatings to small AM coupon surfaces will be demonstrated using existing hardware and characterization tools at Sigma. This study alone will provide ground-breaking insight on the compatibility of ALD coating techniques with AM metals. Going beyond the phase 1 study, a standalone deposition chamber will be built, so full AM components can be coated and tested. While this MFR investment is focused on corrosion mitigation, it is critical to highlight external benefits of this technique outside the scope of this proposed study. ALD has extraordinary universality, whereby almost any material can be given almost any coating or graded density coating with atomic precision; and, the only limiting factors to scalability is the size of the dosing chamber. The self-limiting reactions intrinsic to ALD offers high conformity to part geometry and tolerance, even for internal surfaces where electroplating or conventional chemical vapor deposition falls short due to differential diffusion. This uniquely positions ALD at the forefront of post-manufacturing strategies for AM components, especially for those with complex geometry and internal surfaces.

36 MATERIALS SCIENCE↗

Low–Cost Bio-Based Carbon Fiber for High-Temperature Processing

GrafTech International Holdings Inc. (GTI), worked with Oak Ridge National Laboratory (ORNL) under CRADA No. NFE-15-05807 to develop lignin-based carbon fiber (LBCF) technology and to demonstrate LBCF performance in high-temperature products and applications. This work was unique and different from other reported LBCF work in that this study was application-focused and scalability-focused. Accordingly, the executed work was based on meeting criteria based on technology development, cost, and application suitability. The focus of this work was to demonstrate lab-scale LBCF from at least 4 different precursor feedstock sources that could meet the estimated production cost of $5.00/pound and have ash level of less than 500 ppm in the carbonized insulation-grade fiber. Accordingly, a preliminary cost model was developed based on publicly available information. The team demonstrated that 4 lignin samples met the cost criteria, as highlighted in Table 1. In addition, the ash level for the 4 carbonized lignin samples were below 500 ppm. Processing asreceived lignin to produce a high purity lignin fiber was a significant accomplishment in that most industrial lignin, prior to purification, had greater than 4X the ash level needed for this project, and prior to this work there was not a clear path of how to achieve the purity target. The lab scale development of LBCF was performed with a specific functional application in mind, specifically for high temperature rigid insulation. GTI is currently a consumer of foreignsourced pitch and rayon based carbon fibers for use in its high temperature insulation products, and the motivation was that LBCF had potential to decrease costs and increase product competitiveness in the marketplace through lowered raw material costs, lowered energy costs, and decreased environmental footprint. At the end of this project, the Technology Readiness Level (TRL) remained at 5 for LBCF in high temperature insulation.

36 MATERIALS SCIENCE↗

Vibration Characteristics Determined for Stainless Steel Sandwich Panels With a Metal Foam Core for Lightweight Fan Blade Design

The goal of this project at the NASA Glenn Research Center is to provide fan materials that are safer, weigh less, and cost less than the currently used titanium alloy or polymer matrix composite fans. The proposed material system is a sandwich fan construction made up of thin solid face sheets and a lightweight metal foam core. The stiffness of the sandwich structure is increased by separating the two face sheets by the foam layer. The resulting structure has a high stiffness and lighter weight in comparison to the solid facesheet material alone. The face sheets carry the applied in-plane and bending loads (ref. 1). The metal foam core must resist the transverse shear and transverse normal loads, as well as keep the facings supported and working as a single unit. Metal foams have ranges of mechanical properties, such as light weight, impact resistance, and vibration suppression (ref. 2), which makes them more suitable for use in lightweight fan structures. Metal foams have been available for decades (refs. 3 and 4), but the difficulties in the original processes and high costs have prevented their widespread use. However, advances in production techniques and cost reduction have created a new interest in this class of materials (ref. 5). The material chosen for the face sheet and the metal foam for this study was the aerospace-grade stainless steel 17-4PH. This steel was chosen because of its attractive mechanical properties and the ease with which it can be made through the powder metallurgy process (ref. 6). The advantages of a metal foam core, in comparison to a typical honeycomb core, are material isotropy and the ease of forming complex geometries, such as fan blades. A section of a 17-4PH sandwich structure is shown in the following photograph. Part of process of designing any blade is to determine the natural frequencies of the particular blade shape. A designer needs to predict the resonance frequencies of a new blade design to properly identify a useful operating range. Operating a blade at or near the resonance frequencies leads to high-cycle fatigue, which ultimately limits the blade's durability and life. So the aim of this study is to determine the variation of the resonance frequencies for an idealized sandwich blade as a function of its face-sheet thickness, core thickness, and foam density. The finite element method is used to determine the natural frequencies for an idealized rectangular sandwich blade. The proven Lanczos method (ref. 7) is used in the study to extract the natural frequency.

Ghosn, Louis J.↗

Phase 2 Study of Accelerated Hypofractionated Thoracic Radiation Therapy and Concurrent Chemotherapy in Patients With Limited-Stage Small-Cell Lung Cancer

Purpose: To prospectively investigate the efficacy and toxicity of accelerated hypofractionated thoracic radiation therapy (HypoTRT) combined with concurrent chemotherapy in the treatment of limited-stage small-cell lung cancer (LS-SCLC), with the hypothesis that both high radiation dose and short radiation time are important in this setting. Methods and Materials: Patients with previously untreated LS-SCLC, Eastern Cooperative Oncology Group performance status of 0 to 2, and adequate organ function were eligible. HypoTRT of 55 Gy at 2.5 Gy per fraction over 30 days was given on the first day of the second or third cycle of chemotherapy. An etoposide/cisplatin regimen was given to 4 to 6 cycles. Patients who had a good response to initial treatment were offered prophylactic cranial irradiation. The primary endpoint was the 2-year progression-free survival rate. Results: Fifty-nine patients were enrolled from July 2007 through February 2012 (median age, 58 years; 86% male). The 2-year progression-free survival rate was 49.0% (95% confidence interval [CI] 35.3%-62.7%). Median survival time was 28.5 months (95% CI 9.0-48.0 months); the 2-year overall survival rate was 58.2% (95% CI 44.5%-71.9%). The 2-year local control rate was 76.4% (95% CI 63.7%-89.1%). The severe hematologic toxicities (grade 3 or 4) were leukopenia (32%), neutropenia (25%), and thrombocytopenia (15%). Acute esophagitis and pneumonitis of grade ≥3 occurred in 25% and 10% of the patients, respectively. Thirty-eight patients (64%) received prophylactic cranial irradiation. Conclusion: Our study showed that HypoTRT of 55 Gy at 2.5 Gy per fraction daily concurrently with etoposide/cisplatin chemotherapy has favorable survival and acceptable toxicity. This radiation schedule deserves further investigation in LS-SCLC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ASCENDE-RT: An Analysis of Treatment-Related Morbidity for a Randomized Trial Comparing a Low-Dose-Rate Brachytherapy Boost with a Dose-Escalated External Beam Boost for High- and Intermediate-Risk Prostate Cancer

Purpose: To report the genitourinary (GU) and gastrointestinal (GI) morbidity and erectile dysfunction in a randomized trial comparing 2 methods of dose escalation for high- and intermediate-risk prostate cancer. Methods and Materials: ASCENDE-RT (Androgen Suppression Combined with Elective Nodal and Dose Escalated Radiation Therapy) enrolled 398 men, median age 68 years, who were then randomized to either a standard arm that included 12 months of androgen deprivation therapy and pelvic irradiation to 46 Gy followed by a dose-escalated external beam radiation therapy (DE-EBRT) boost to 78 Gy, or an experimental arm that substituted a low-dose-rate prostate brachytherapy (LDR-PB) boost. At clinic visits, investigators recorded GU and GI morbidity and information on urinary continence, catheter use, and erectile function. Exclusion of 15 who received nonprotocol treatment and correction of 14 crossover events left 195 men who actually received a DE-EBRT boost and 188, an LDR-PB boost. Median follow-up was 6.5 years. Results: The LDR-PB boost increased the risk of needing temporary catheterization and/or requiring incontinence pads. At 5 years the cumulative incidence of grade 3 GU events was 18.4% for LDR-PB, versus 5.2% for DE-EBRT (P<.001). Compared with the cumulative incidence, the 5-year prevalence of grade 3 GU morbidity was substantially lower for both arms (8.6% vs 2.2%, P=.058). The 5-year cumulative incidence of grade 3 GI events was 8.1% for LDR-PB, versus 3.2% for DE-EBRT (P=.124). The 5-year prevalence of grade 3 GI toxicity was lower than the cumulative incidence for both arms (1.0% vs 2.2%, respectively). Among men reporting adequate baseline erections, 45% of LDR-PB patients reported similar erectile function at 5 years, versus 37% after DE-EBRT (P=.30). Conclusions: The incidence of acute and late GU morbidity was higher after LDR-PB boost, and there was a nonsignificant trend for worse GI morbidity. No differences in the frequency of erectile dysfunction were observed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility and Efficacy of Single Photon Emission Computed Tomography-Based Three-Dimensional Conformal Radiotherapy for Hepatocellular Carcinoma 8 cm or More With Portal Vein Tumor Thrombus in Combination With Transcatheter Arterial Chemoembolization

Purpose: To assess the feasibility and efficacy of single photon emission computed tomography-based three-dimensional conformal radiotherapy (SPECT-B 3D-CRT) for large hepatocellular carcinoma (HCC) with portal vein tumor thrombus (PVTT). Methods and Materials: HCC patients with PVTT in the first branch or main trunk, 8 cm or greater in size, were admitted to the study. SPECT, using Tc-99m-galactosyl human serum albumin, was used in radiation treatment planning to explore the optimal irradiation beam angle. SPECT enabled the minimum possible irradiation of functional liver (FL). Clinical target volume (CTV) included the main tumor and PVTT. SPECT-B 3D-CRT targeted the CTV to a total dose of 45 Gy/18 fractions. HCC outside the CTV was treated by transcatheter arterial chemoembolization (TACE). Results: Nineteen cases were enrolled in this study. The mean maximum dimension, mean CTV, and mean dose to FL were 11.0 cm (range, 8.0-20.0), 435 cm{sup 3} (range, 60-2,535), and 1,102 cGy (range, 691-1,695), respectively. Follow-up SPECT demonstrated radiation-induced dysfunctional liver. Despite the inclusion of 6 cases of Child-Pugh B or C, no patients experienced Grade 3 or worse radiation-induced liver disease. The cumulative non-progression rates of PVTT and PVTT plus main tumor were 78.0 and 43.2%, respectively. Survival rates at 1 and 2 years were 47.4 and 23.7%, respectively. Conclusions: SPECT-B 3D-CRT with TACE appears to be tolerable to cirrhotic liver and to provide promising prognosis for patients with HCC sized 8 cm or more, in comparison with previous treatment methods. A longer follow-up period is required to evaluate these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Curved Waveguide Based Nuclear Fission for Small, Lightweight Reactors

The focus of the presented work is on the creation of a system of grazing incidence, supermirror waveguides for the capture and reuse of fission sourced neutrons. Within research reactors, neutron guides are a well known tool for directing neutrons from the confined and hazardous central core to a more accessible testing or measurement location. Typical neutron guides have rectangular, hollow cross sections, which are crafted as thin, mirrored waveguides plated with metal (commonly nickel). Under glancing angles with incoming neutrons, these waveguides can achieve nearly lossless transport of neutrons to distant instruments. Furthermore, recent developments have created supermirror surfaces which can accommodate neutron grazing angles up to four times as steep as nickel. A completed system will form an enclosing ring or spherical resonator system to a coupled neutron source for the purpose of capturing and reusing free neutrons to sustain and/or accelerate fission. While grazing incidence mirrors are a known method of directing and safely using neutrons, no method has been disclosed for capture and reuse of neutrons or sustainment of fission using a circular waveguide structure. The presented work is in the process of fabricating a functional, highly curved, neutron supermirror using known methods of Ni-Ti layering capable of achieving incident reflection angles up to four times steeper than nickel alone. Parallel work is analytically investigating future geometries, mirror compositions, and sources for enabling sustained fission with applicability to the propulsion and energy goals of NASA and other agencies. Should research into this concept prove feasible, it would lead to development of a high energy density, low mass power source potentially capable of sustaining fission with a fraction of the standard critical mass for a given material and a broadening of feasible materials due to reduced rates of release, absorption, and non-fission for neutrons. This advance could be applied to direct propulsion through guided fission products or as a secondary energy source for high impulse electric propulsion. It would help meet national needs for highly efficient energy sources with limited dependence on fossil fuels or conflict materials, and it would improve the use of low grade fissile materials which would help reduce national stockpiles and waste.

Coker, Robert↗

Vapor-induced phase-separation-enabled versatile direct ink writing

Abstract Versatile printing of polymers, metals, and composites always calls for simple, economic approaches. Here we present an approach to three-dimensional (3D) printing of polymeric, metallic, and composite materials at room conditions, based on the polymeric vapor-induced phase separation (VIPS) process. During VIPS 3D printing (VIPS-3DP), a dissolved polymer-based ink is deposited in an environment where nebulized non-solvent is present, inducing the low-volatility solvent to be extracted from the filament in a controllable manner due to its higher chemical affinity with the non-solvent used. The polymeric phase is hardened in situ as a result of the induced phase separation process. The low volatility of the solvent enables its reclamation after the printing process, significantly reducing its environmental footprint. We first demonstrate the use of VIPS-3DP for polymer printing, showcasing its potential in printing intricate structures. We further extend VIPS-3DP to the deposition of polymer-based metallic inks or composite powder-laden polymeric inks, which become metallic parts or composites after a thermal cycle is applied. Furthermore, spatially tunable porous structures and functionally graded parts are printed by using the printing path to set the inter-filament porosity as well as an inorganic space-holder as an intra-filament porogen.

42 ENGINEERING↗

Analysis of Clinical and Dosimetric Factors Associated With Change in Renal Function in Patients With Gastrointestinal Malignancies After Chemoradiation to the Abdomen

Purpose: To analyze clinical and dosimetric factors associated with change in renal function in patients with gastrointestinal malignancies after chemoradiation to the abdomen. Methods and Materials: A retrospective review of 164 patients with gastrointestinal malignancies treated between 2002 and 2007 was conducted to evaluate change in renal function after concurrent chemotherapy and three-dimensional conformal abdominal radiotherapy (RT). Laboratory and biochemical endpoints were determined before RT and after RT at 6-month intervals. Factors assessed included smoking, diabetes, hypertension, blood urea nitrogen, creatinine, creatinine clearance (CrCl), chemotherapy, and dose-volume parameters. Renal toxicity was assessed by decrease in CrCl and scored using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer late radiation morbidity scoring schema. Results: Of 164 patients, 63 had clinical and dosimetric data available. Median follow-up was 17.5 months. Creatinine clearance declined from 98.46 mL/min before RT to 74.20 mL/min one year after chemoradiation (p < 0.0001). Mean decrease in CrCl was 21.37%. Pre-RT CrCl, percentage of bilateral renal volume receiving at least 10 Gy (V{sub 10}), and mean kidney dose were significantly associated with development of Grade >=2 renal complications at 1 year after chemoradiation (p = 0.0025, 0.0170, and 0.0095, respectively). Conclusions: We observed correlation between pre-RT CrCl, V{sub 10}, and mean kidney dose and decline in CrCl 1 year after chemoradiation. These observations can assist in treatment planning and renal dose constraints in patients receiving chemotherapy and abdominal RT and may help identify patients at increased risk for renal complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DAMAGE DEVELOPMENT IN HIGH PURITY COPPER UNDER VARYING DYNAMIC CONDITIONS AND MICROSTRUCTURAL STATES USING CONTINUUM DAMAGE MECHANICS

In the framework of CDM, the evolution of the plastic strain, at which damage processes initiates, as a function of stress triaxiality, making the assumption of constant damage dissipated work is derived. Based on this, the CDM model proposed by Bonora (Eng. Frac. Mech., 58, 1-2, 1997) has been used to predict the occurrence of ductile failure at different stress triaxiality conditions, under both quasi-static and dynamic loading conditions. This solution allows the possibility to correctly predict the conditions for which ductile damage can initiate under uniaxial strain (such as that for the flyer plate impact test) and mixed conditions such as those in the Taylor impact test. The solution offers the possibility to correlate continuum damage model parameters to micro structural features such as grain size and purity grade.

36 MATERIALS SCIENCE↗