Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Electron Diamagnetic Effect on Axial Force in an Expanding Plasma: Experiments and Theory

The axial force imparted from a magnetically expanding current-free plasma is directly measured for three different experimental configurations and compared with a two-dimensional fluid theory. The force component solely resulting from the expanding field is directly measured and identified as an axial force produced by the azimuthal current due to an electron diamagnetic drift and the radial component of the magnetic field. The experimentally measured forces are well described by the theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-interface Richtmyer-Meshkov turbulent mixing at the Los Alamos Vertical Shock Tube

We studied Mach number and initial conditions effects on Richtmyer–Meshkov (RM) mixing by the vertical shock tube (VST) at Los Alamos National Laboratory (LANL). At the VST, a perturbed stable light-to-heavy (air–SF 6 , A=0.64) interface is impulsively accelerated with a shock wave to induce RM mixing. We investigate changes to both large and small scales of mixing caused by changing the incident Mach number (Ma=1.3 and 1.45) and the three-dimensional (3D) perturbations on the interface. Simultaneous density (quantitative planar laser-induced fluorescence (PLIF)) and velocity (particle image velocimetry (PIV)) measurements are used to characterize preshock initial conditions and the dynamic shocked interface. Initial conditions and fluid properties are characterized before shock. Using two types of dynamic measurements, time series (N=5 realizations at ten locations) and statistics (N=100 realizations at a single location) of the density and velocity fields, we calculate several mixing quantities. Mix width, density-specific volume correlations, density–vorticity correlations, vorticity, enstrophy, strain, and instantaneous dissipation rate are examined at one downstream location. Results indicate that large-scale mixing, such as the mix width, is strongly dependent on Mach number, whereas small scales are strongly influenced by initial conditions. Lastly, the enstrophy and strain show focused mixing activity in the spike regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Imaging viscous flow of the Dirac fluid in graphene

The electron–hole plasma in charge-neutral graphene is predicted to realize a quantum critical system in which electrical transport features a universal hydrodynamic description, even at room temperature. This quantum critical ‘Dirac fluid’ is expected to have a shear viscosity close to a minimum bound, with an interparticle scattering rate saturating1 at the Planckian time, the shortest possible timescale for particles to relax. Although electrical transport measurements at finite carrier density are consistent with hydrodynamic electron flow in graphene a clear demonstration of viscous flow at the charge-neutrality point remains elusive. In this work, we directly image viscous Dirac fluid flow in graphene at room temperature by measuring the associated stray magnetic field. Nanoscale magnetic imaging is performed using quantum spin magnetometers realized with nitrogen vacancy centres in diamond. Scanning single-spin and wide-field magnetometry reveal a parabolic Poiseuille profile for electron flow in a high-mobility graphene channel near the charge-neutrality point, establishing the viscous transport of the Dirac fluid. This measurement is in contrast to the conventional uniform flow profile imaged in a metallic conductor and also in a low-mobility graphene channel. Furthermore, via combined imaging and transport measurements, we obtain viscosity and scattering rates, and observe that these quantities are comparable to the universal values expected at quantum criticality. This finding establishes a nearly ideal electron fluid in charge-neutral, high-mobility graphene at room temperature4. Our results will enable the study of hydrodynamic transport in quantum critical fluids relevant to strongly correlated electrons in high-temperature superconductors9. This work also highlights the capability of quantum spin magnetometers to probe correlated electronic phenomena at the nanoscale.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spring constant calibration of atomic force microscope cantilevers of arbitrary shape

The spring constant of an atomic force microscope cantilever is often needed for quantitative measurements. The calibration method of Sader et al. [Rev. Sci. Instrum. 70, 3967 (1999)] for a rectangular cantilever requires measurement of the resonant frequency and quality factor in fluid (typically air), and knowledge of its plan view dimensions. This intrinsically uses the hydrodynamic function for a cantilever of rectangular plan view geometry. Here, we present hydrodynamic functions for a series of irregular and non-rectangular atomic force microscope cantilevers that are commonly used in practice. Cantilever geometries of arrow shape, small aspect ratio rectangular, quasi-rectangular, irregular rectangular, non-ideal trapezoidal cross sections, and V-shape are all studied. This enables the spring constants of all these cantilevers to be accurately and routinely determined through measurement of their resonant frequency and quality factor in fluid (such as air). An approximate formulation of the hydrodynamic function for microcantilevers of arbitrary geometry is also proposed. Implementation of the method and its performance in the presence of uncertainties and non-idealities is discussed, together with conversion factors for the static and dynamic spring constants of these cantilevers. These results are expected to be of particular value to the design and application of micro- and nanomechanical systems in general.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty Quantification by Monte Carlo Analysis using CFD Simulations for GEMIX Benchmark Activities

Uncertainty quantification (UQ) methods can be applied to computational fluid dynamics (CFD) simulations for determining the uncertainty bands of the simulations results. In order to determine the applicability of these different methods, simple benchmark activities have been conducted by various group for comparison. The GEMIX (Generic Mixing experiment) test facility was used to develop benchmark data for this purpose by the Paul Scherrer Institute (PSI). The facility involves the mixing of two fluids that are initially separated. One of the two fluids is water with sugar dissolved in it to create a fluid with similar fluid properties to water, except for density. The other fluid was distilled water to reduce the uncertainty in the fluid's properties. During the experiments, velocity fields and concentration measurements were acquired at several planes of interest. The velocity fields were acquired using particle image velocimetry (PIV) and concentrations of each fluid were acquired using laser induced fluorescence (LIF). The inlet velocity profiles were acquired using laser Doppler velocimetry (LDV). The activity provided the opportunity to vary turbulence models, meshing methodologies, and numerical schemes for creation of uncertainty estimates. The present study investigates the usage of a simple Monte Carlo (MC) technique for varying the inlet boundary conditions of each inlet. The velocity profiles and densities of each inlet were specifically varied based on experiment measurement uncertainty. The intent was to isolate the uncertainty due to inlet quantities and not related to meshing, numerical scheme, or turbulence models. The comparisons of experimental and simulation results were found to be reasonably accurate. Though deficiencies were identified in the modeling approach to be corrected in future works by the authors. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Complexity of Fault Rupture and Fluid Leakage in Shale: Insights From a Controlled Fault Activation Experiment

Abstract We observed rupture growth caused by controlled fluid injections at 340‐m depth within a fault zone in the low‐permeability Opalinus Clay in the Mont Terri Underground Research Laboratory (Switzerland). The rupture mechanisms were evaluated using measurements of the three‐component borehole wall displacements and fluid pressure in two sections of the fault zone and located horizontally 3 m apart from each other. One section was set across a secondary segment of the fault and used for stepwise fluid injection intended to trigger rupture growth. The other section was set across the principal shear zone of the fault for monitoring. After stepwise pressure increase up to 5.95 MPa at injection, rupture initiated as slip activation, followed by an overall opening of the fault planes connected to the injection. After 19 s of continued injection, displacements arrived at the monitoring point on the principal shear zone. These displacements are about 2.4 times larger than in the secondary fault segment. Overall, the displacements corresponded to a normal fault activation. About 9 s after the displacement front arrived, a strong pressure increase of 4.17 MPa was measured at the monitoring point, indicating a hydraulic connection had formed along the initially very low permeability fault planes between the injection and the monitoring points. Our analyses highlight that the fault activation is consistent with the state of stress but that injection pressure must be close to the normal stress acting on the fault for permeability to be generated and for fluid leakage to occur.

Guglielmi, Yves↗

Monitoring pipeline integrity of underground gas storage facilities using membrane-based electrochemical sensors

Effective monitoring of internal corrosion risk is crucial to ensuring the safety and longevity of natural gas pipeline infrastructure. While electrochemical sensors are commonly used to assess corrosion rates and corrosion indicators in aqueous fluids, they are rarely used in gas pipelines as these fluids lack the ionic conductivity needed for electrochemical measurements. The inclusion of ion-conductive membranes into electrochemical sensors can extend their functionality into humidified gas streams, providing critical information about emerging corrosion events that are common during withdrawal season in pipeline systems downstream from underground storage facilities. In parallel, new protective films, like those obtained through cold spray coating, are being developed to protect oil and gas pipelines and recover losses in structural integrity due to corrosion damage. Herein, we demonstrate how membrane-based electrochemical sensors (MBES) can be used to monitor fluid corrosivity by examining their response to changes in water content for a wide range of fluid compositions. It was found that MBES readings were highly sensitive to water content changes with membrane conductivity measurements varying from 10 –6 to 10 –1 S cm -1 , and corrosion rate measurements which varied from 10 –7 to 1 mm y -1 . Electron microscopy confirmed that the self-healing characteristics of metal coating films were still active despite their inclusion into an MBES probe. In conclusion, these findings indicate that membrane-based corrosion monitoring can be expanded to monitor coated-pipeline materials and provide early detection of emerging corrosion upsets relevant to underground gas storage facilities.

Electrochemical sensor↗

Coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) for engineering flow measurements

Increasingly, fully 3D experimental measurements of flow in complex engineering geometries are required to validate computational fluid dynamics models that support and inform reactor design and licensing. One barrier to such measurements is the complexity of typical reactor components and subsequent lack of optical access in these systems. To overcome this, the deployment of coregistered positron emission particle tracking (PEPT) and X-ray computed tomography (CT) is explored for flow measurement in reactor thermal hydraulic components and model (scaled) systems. Through this methodology, fully 3D flow information (via PEPT) and detailed internal geometry (via CT) are captured in opaque systems such as pipes, rod bundles, packed beds, etc. The reconstructed flow field and geometry can then be overlain to reveal detailed flow features around internal structures within a given test section. This is enabled through the use of a combined preclinical PET/CT scanner with overlapping PET and CT fields of view. Such measurements are useful for characterizing flow inside such intricate nuclear thermal hydraulic components as core geometries and heat exchangers, among others, and providing valuable 3D validation data for CFD models. In this work, basic tests of this 3D flow/geometry mapping are presented, and the implications of such measurements are discussed. Further, preliminary measurements are made with both point sources and flow in a simple pipe flow geometry to evaluate the capabilities of this technique. PEPT and CT features are coregistered with up to 0.1 mm precision, and pipe flow mean velocity and Reynolds stresses are reconstructed with similar accuracy to previous PEPT demonstrations. The utility of PEPT/CT is shown herein, and suggestions for future measurements are made.

3D flow measurement↗

High-temperature, high pressure acoustic resonance cell

A compact, rugged and portable measurement cell design for the determination of sound speed in fluids at temperatures up to 250° C. and pressures up to 3,000 psi is described. Swept Frequency Acoustic Interferometry measurement for liquid sound speed determinations in liquids up to 250° C. is of both fundamental interest, as in the case of basic equations of state, and applied interest, such as for characterizing geothermal or petroleum down hole environments. Representative sound speeds for water, as a function of temperature and pressure, are in agreement with an internationally accepted standard for the sound speed of water.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of fracture diagnostic methods for fluid distribution based on quantitative interpretation of distributed acoustic sensing and distributed temperature sensing

Multistage hydraulic fracturing design on horizontal wells has significantly evolved with larger fluid volume, more fracturing stages, and tighter perforation cluster spacing to efficiently stimulate unconventional reservoirs. From the published field observations, the recent fracturing design results in complex fracture networks or swarm of fractures. Fracture treatment evaluation is extremely challenging in such a case because of the large amount of variables in well completion and stimulation design. Combined measurements from different technologies can help in fracture diagnosis. Fluid distribution, either during fracture injection or during production, directly relates to the stimulation efficiency at the cluster level and at the stage level. Because it is unlikely in the real world to distribute the injected fluid uniformly among all the clusters, we need diagnostic techniques to generate the flow profile along a lateral. Fiber-optic measurements, such as distributed acoustic sensing (DAS) and distributed temperature sensing (DTS), are currently used to diagnose downhole flow conditions. This technology allows us to qualitatively confirm the fluid flow profile and other issues occurring downhole during fracturing such as leakage through plugs. For optimizing a fracturing design, we also need to understand how the design parameters are correlated with the stimulation efficiency. In this study, we combine two sets of models of DAS and DTS data interpretation for injected fluid volume distribution. The DAS is interpreted based on an empirical correlation between fluid flow rates and frequency band energy from the acoustic signals. The DTS is interpreted by performing temperature history match-based thermal energy conservation. Because of the completely different physics behind the interpretations, the confirmation of two interpretations provides confidence in fluid distribution.

Geochemistry & Geophysics↗

Energy transfer between a passing vortex ring and a flexible plate in an ideal quiescent fluid

Recent advancements in highly deformable smart materials have lead to increasing interest in small-scale energy harvesting research for powering low consumption electronic devices. One such recent experimental study by Goushcha et al. explored energy harvesting from a passing vortex ring by a cantilevered smart material plate oriented parallel to and offset from the path of the ring in an otherwise quiescent fluid. The present study focuses on modeling this experimental study using potential flow to facilitate optimization of the energy extraction from the passing ring to raise the energy harvesting potential of the device. The problem is modeled in two-dimensions with the vortex ring represented as a pair of counter-rotating free vortices. Vortex pair parameters are determined to match the convection speed of the ring in the experiments, as well as the imposed pressure loading on the plate. The plate is approximated as a Kirchhoff-Love plate and represented as a finite length vortex sheet in the fluid domain. The analytical model matches experimental measurements, including the tip displacement, the integrated force along the entire plate length as a function of vortex ring position, and the pressure along the plate. The potential flow solution is employed in a parametric study of the governing dimensionless parameters in an effort to guide the selection of plate properties for optimal energy harvesting performance. Results of the study indicate an optimal set of plate properties for a given vortex ring configuration, in which the time-scale of vortex advection matches that of the plate vibration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Rarefied piezometric uptake apparatus and method for measuring gaseous uptake

A rarefied piezometric uptake apparatus and method for measuring gaseous uptake for large solid samples with little or no sample preparation. Past systems and methods require extensive sample preparation. The method includes providing a rarefied piezometric uptake apparatus having a dosing chamber and uptake chamber in an improved selective fluid communication. The apparatus and method improve the measurement of gaseous uptake into solid samples resulting in improved prediction of gas migration through solid samples such as geologic formations.

Paul, Matthew J.↗

Medium amplitude parallel superposition (MAPS) rheology. Part 2: Experimental protocols and data analysis

An experimental protocol is developed to directly measure the new material functions revealed by medium amplitude parallel superposition (MAPS) rheology. This protocol measures the medium amplitude response of a material to a simple shear deformation composed of three sine waves at different frequencies, revealing a rich dataset consisting of up to 19 measurements of the third-order complex modulus at distinct three-frequency coordinates. We discuss how the choice of input frequencies influences the features of the MAPS domain studied by the experiment. A polynomial interpolation method for reducing the bias of measured values from spectral leakage and reducing variance due to noise is discussed, including a derivation of the optimal range of amplitudes for the input signal. This leads to the conclusion that conducting the experiment in a stress-controlled fashion possesses a distinct advantage to the strain-controlled mode. The experimental protocol is demonstrated through measurements of the MAPS response of a model complex fluid: a surfactant solution of wormlike micelles. The resulting dataset is indeed large and feature-rich, while still acquired in a time comparable to similar medium amplitude oscillatory shear (MAOS) experiments. We demonstrate that the data represent measurements of an intrinsic material function by studying its internal consistency, compatibility with low-frequency predictions for Coleman–Noll simple fluids, and agreement with data obtained via MAOS amplitude sweeps. Finally, the data are compared to predictions from the corotational Maxwell model to demonstrate the power of MAPS rheology in determining whether a constitutive model is consistent with a material’s time-dependent response.

Lennon, Kyle R. (ORCID:0000000212515461)↗

MIXTURES OF CO2-SF6 AS WORKING FLUIDS FOR GEOTHERMAL PLANTS

In this paper, mixtures of CO2 and SF6 were evaluated as working fluids for geothermal plants based on property measurements, molecular dynamics modeling, thermodynamic cycle analysis, and materials compatibility assessment. The CO2 - SF6 was evaluated for a reservoir temperature of 160 oC. Increasing the efficiency for these low reservoir sources will increase the options available for geothermal energy utilization in more sites across the country. The properties for the mixtures were obtained either from thermodynamic property measurements and molecular dynamics simulations. Optimum compositions of the CO2 - SF6 were identified for a well reservoir temperature and a given water-cooling condition. Concerning the global warming potential, it was estimated that the equivalent CO2 emissions per 1kWh for a Rankine cycle operating with 100% SF6 would be approximately of 7.6% than those for a coal-fired power plant.

15 GEOTHERMAL ENERGY↗

Measurement with microscopic MRI and simulation of flow in different aneurysm models

Purpose: The impact and the development of aneurysms depend to a significant degree on the exchange of liquid between the regular vessel and the pathological extension. A better understanding of this process will lead to improved prediction capabilities. The aim of the current study was to investigate fluid-exchange in aneurysm models of different complexities by combining microscopic magnetic resonance measurements with numerical simulations. In order to evaluate the accuracy and applicability of these methods, the fluid-exchange process between the unaltered vessel lumen and the aneurysm phantoms was analyzed quantitatively using high spatial resolution. Methods: Magnetic resonance flow imaging was used to visualize fluid-exchange in two different models produced with a 3D printer. One model of an aneurysm was based on histological findings. The flow distribution in the different models was measured on a microscopic scale using time of flight magnetic resonance imaging. The whole experiment was simulated using fast graphics processing unit-based numerical simulations. The obtained simulation results were compared qualitatively and quantitatively with the magnetic resonance imaging measurements, taking into account flow and spin–lattice relaxation. Results: The results of both presented methods compared well for the used aneurysm models and the chosen flow distributions. The results from the fluid-exchange analysis showed comparable characteristics concerning measurement and simulation. Similar symmetry behavior was observed. Based on these results, the amount of fluid-exchange was calculated. Depending on the geometry of the models, 7% to 45% of the liquid was exchanged per second. Conclusions: The result of the numerical simulations coincides well with the experimentally determined velocity field. The rate of fluid-exchange between vessel and aneurysm was well-predicted. Hence, the results obtained by simulation could be validated by the experiment. The observed deviations can be caused by the noise in the measurement and by the limited resolution of the simulation. The resulting differences are small enough to allow reliable predictions of the flow distribution in vessels with stents and for pulsed blood flow.

60 APPLIED LIFE SCIENCES↗

A Fluid Pulse on the Hikurangi Subduction Margin: Evidence From a Heat Flux Transect Across the Upper Limit of Gas Hydrate Stability: Fluid Pulse on the Hikurangi Margin

A transect of seafloor heat probe measurements on the Hikurangi Margin shows a significant increase of thermal gradients upslope of the updip limit of gas hydrate stability at the seafloor. We interpret these anomalously high thermal gradients as evidence for a fluid pulse leading to advective heat flux, while endothermic cooling from gas hydrate dissociation depresses temperatures in the hydrate stability field. Previous studies predict a seamount on the subducting Pacific Plate to cause significant overpressure beneath our study area, which may be the source of the fluid pulse. Double-bottom simulating reflections are present in our study area and likely caused by uplift based on gas hydrate phase boundary considerations, although we cannot exclude a thermogenic origin. We suggest that uplift may be associated with the leading edge of the subducting seamount. Our results provide further evidence for the transient nature of fluid expulsion in subduction zones.

58 GEOSCIENCES↗