Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Energy use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Medical Imaging Equipment Energy Efficiency [Slides]

The slide deck is being prepared for healthcare sector stakeholders as a resource on the energy use of Medical Imaging Equipment (MIE) which will provide an overview of existing work, review existing literature on MIE energy use and identify energy efficiency opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Minimizing Electric Lighting Use With LASSI Lighting Controls in Controlled Environment Agriculture

The majority of energy use in controlled environment agriculture is typically from electric lighting. Certain lighting controls can help minimize the energy required in these operations. This analysis simulates a greenhouse with different types of lighting controls in different U.S. climates to explore the effects of the lighting controls on energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analytical Modeling of Metal Foam Composite Phase Change Materials (PCM) in Thermal Energy Storage Using Asymptotic Analysis

The use of phase change materials (PCMs) for thermal energy storage can release or absorb a significant amount of latent heat during the freezing or melting process, offering a higher energy storage density. One of the main drawbacks of PCMs is their low thermal conductivity, resulting in poor thermal performance. Recent research has attempted to enhance heat transfer and increase the thermal conductivity of PCMs, including the use of metal foams. However, modeling the metal foam composite PCM using conventional methods is computationally expensive. This paper proposes an asymptotic solution for a Stefan-like problem subject to a convective boundary for outward solidification in a hollow cylinder, capable of predicting the freeze-melt cycle of the metal foam composite PCM. Specifically, three temporal regimes and four spatial layers are considered in the asymptotic analysis for each phase change process. The thermal conductivity is calculated by a theoretical three-dimensional tetrakaidecahedron model, while other thermophysical properties are obtained using the method of volume averaging. The results are verified with numerical data and validated against experimental data in the literature. The presented analytical modeling framework could have the potential to be applied to other types of composite PCMs with considerably lower computational costs compared with conventional methods.

analytical model↗

Microcam: A Low Power and Privacy Preserving Multi-modal Platform for Occupancy Detection (Final Report)

Heating, ventilation, and air conditioning (HVAC) consumes a significant portion of the energy used in buildings. Much of this is wasted energy, used when buildings are either not occupied at all, or occupied well under their maximum design conditions. This project has focused on residential occupancy detection to autonomously control HVAC systems and save energy. Limitations of existing occupancy sensors include one or more of the following: (i) they employ sensors or algorithms that are not able to detect stationary occupants; (ii) they cannot classify the source of the motion (such as a pet); (iii) depending on the camera resolution and employed algorithms, they do not allow for embedded or onboard computation, and require external or cloud-based processing; (iv) many algorithms developed for camera-based systems are sensitive to lighting changes, and thus prone to missed detections or false alarms; (v) Most existing systems depend on adjustment of settings for different scenarios, complicating self-commissioning; (vi) they cannot provide high enough accuracy; (vii) they are costly; (viii) they are not battery-powered, thus limiting ease of use and installation. In this project, Syracuse University and its partner SRI have developed a low-cost, high accuracy, standalone residential occupancy sensing platform, referred to as the MicroCam, to address all of the aforementioned challenges. MicroCam can operate on typical alkaline batteries without relying on the “cloud” or external computing resources, and consists of low-power, Artificial Intelligence (AI)-based, IoT platforms. Each platform has multi-modal sensors and can process motion, audio and video data, and send binary occupancy result to a lead platform. All sensor data is processed locally on platforms, and the only transmitted data is the binary occupancy state. In addition, preliminary work has been done on images wherein occupants are not discernable. Thus, MicroCam is a standalone solution preserving privacy of the occupants.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Power Generation of a Bottomraised Oscillating Surge Wave Energy Converter Using a Theoretical Model

Preliminary sizing of an oscillating surge wave energy converter (OSWEC) is an iterative process that relies on knowledge of the relevant hydrodynamic coefficients for a given geometry. Often, the complex definition of the device geometry requires coefficients to be obtained through experiments or numerical boundary element solvers such as WAMIT. These techniques demand significant user and computational effort, therefore inhibiting the fine scale parametrization of object dimensions. In this study, a theoretical model, originally presented in Michele et al. (2016), is developed and demonstrated to efficiently optimize the power production for an OSWEC device (subjected to certain environmental conditions) with variations in device widths, heights, and distances from the seabed. Assuming negligible device thickness, the OSWEC motions are modelled as a bottom-raised two-dimensional flap in regular waves using potential flow theory formulated in elliptical coordinates. The solutions to this diffraction-radiation problem are obtained using Mathieu functions with appropriate boundary conditions. The resulting potentials are then used to derive frequency-dependent expressions for the added mass and radiation damping coefficients, along with wave excitation magnitude in surge, pitch, and coupled surge-pitch motions. Good agreement in hydrodynamic coefficient curves is shown between the theoretical model and the numerical results obtained from the boundary element-based program WAMIT. The theoretical model is then employed to maximize the time-averaged output power while maintaining or reducing the hinge reaction force, with variations in device dimensions, wave frequency and amplitude.

ACE↗

Starting with Solar: A Preliminary Assessment of Solar Energy Systems in Residential New Construction [Slides]

New homes provide a ready option for states hoping to reduce energy use, as evidenced by the steady increase in energy efficiency requirements in new home building codes. A less common approach is to specifically encourage or require new homes to produce their own carbon-free energy, through the installation of a solar energy system. Adopting these practices nationwide might significantly reduce new home energy use, but the drivers of the new solar home market have not been well studied. Partly filling this gap, this report looks at historical deployment trends of solar on over 500,000 new homes built through 2020 across 19 states and the District of Columbia, most of which were in California. California is a useful test case because if first incentivized in 2007, and more recently required in 2018, new homes to have solar. The report finds that solar adoption rates at roughly 40% in recent years in California eclipse—by a wide margin—rates in other states, which top out near 4%. The presence of California’s New Solar Home Partnership (NSHP) incentives appear strongly correlated with deployment levels, as do builder market share. The Top-10 builders in California installed solar in recent years at rates almost three times the average of non-Top-10 builders in the state. Interestingly, the authors found the same large builders did not install solar at the same elevated rates outside California, which might be related to the lack of incentives, they hypothesize. The report also investigates the characteristics of new solar homes such as living area (i.e., square feet), solar system size, frequency of battery installations, and use of third-party ownership. The authors also include quotes directly from builders to provide context to the findings.

14 SOLAR ENERGY↗

Systems and methods of decoupled hydrogen generation using energy-bearing redox pairs

Described herein are systems and methods of hydrogen generation and electrolyte regeneration as independent operations in separate redox flow cells. The operations can be decoupled by using an energy-bearing redox pair that electrochemically bears energy facilitating flexible, efficient hydrogen generation. In one example, the hydrogen generation redox flow cell can include a liquid, energy-bearing electrolyte solution in which at least one species of an energy-bearing redox pair is dissolved, to decouple the hydrogen evolution reaction from the reaction at the opposite electrode (e.g., the oxygen evolution reaction of conventional direct water electrolysis). Each species of the energy-bearing redox pair is associated with a standard electrode potential within the water electrolysis window.

Wang, Wei↗

An Open-Source Framework for Characterizing Urban Energy Models: Integrating Top-Down and Bottom-Up Methods to Predict Residential Buildings Characteristics: Preprint

Bottom-up urban energy models are crucial for understanding current energy use patterns and informing design strategies. However, accurately characterizing these models to represent different communities remains a challenge due to the extensive data needed for simulating existing energy use behavior. This data includes information related to human activities and building characteristics, all of which correlate with socioeconomic factors. To overcome this challenge, we developed an automated framework that utilizes both top-down and bottom-up data, to predict unknown building and occupant characteristics that are needed for more accurate and equitable modeling and analytics. Our framework, integrated into the URBANopt district energy modeling platform, uses statistical data models from ResStock. URBANopt models co-located buildings and neighborhoods. At this scale there are data gaps in building characteristic data, such as materials, insulation, occupancy, income, and energy usage of the buildings. To address this data gap, we use ResStock data, representative at the census tract scale, and develop machine-learning and deeplearning techniques to disaggregate it to individual buildings. By mapping unique occupant, building and economic properties to URBANopt energy models, we gain detailed insights into the variability of building energy use across different neighborhoods. This insight helps deploy technologies for co-located buildings and supports targeted upgrades for communities with unique economic and demographic characteristics, ensuring energy equity. Accurate characterization of energy models allows us to develop equitable strategies tailored to diverse neighborhoods, whether underserved or affluent. Our automated framework streamlines energy modeling and provides a reliable tool for building energy characterization.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Modeling a Lead-Cooled Fast Reactor with Thermal Energy Storage using Optimal Dispatch and SAM

Increased contributions from wind and solar energy have helped set the United States on an attainable pathway towards carbon-free energy production. Though renewable energy is pivotal for this goal, saturating the grid with these variable energy sources has its challenges. Resources for wind and solar vary from factors beyond human control, hence the power output from these energy generators doesn’t necessarily match power demand for a specific region at a given moment in time. Solar photovoltaic production has a drastic mismatch since the peaks for power demand and power production are often out of phase: production peaks with available irradiance while demand peaks during the morning and evening hours. This “duck curve” in energy demand, the difference between high and low demand, grows as the grid becomes more saturated with renewable energy providers.

Soto, Gabriel J.↗

Internal consistency and diversity scenario development: A comparative framework to evaluate energy model scenarios

Energy modeling frameworks and scenario analysis help us explore the potential impact of our actions and uncertainties in future energy systems. Despite their importance, there is no systematic procedure for evaluating the scenario development process. In a literature review, we identify two core elements of the scenario development process: internal consistency and diversity which are oftentimes missing from scenarios. Here, to address this gap, we create the Internal consistency and Diversity Scenario Development (IDSD) comparative framework which aims to assess the feasibility and diversity of scenarios for a given energy model. With this framework, we review commonly used energy models and demonstrate our framework on their scenarios. The IDSD comparative framework can serve several purposes absent from previous scenario development work by aiding energy modelers and report writers in crafting high-quality scenarios. First, the IDSD is a reflective tool which can improve the quality of the scenario development process, enabling a comparative assessment of energy models and scenarios. Second, the IDSD can provide guidance to modeling frameworks with existing scenarios and those still in development; this feedback will enable modelers to improve the development and the communication of the limitations of their scenarios. Third, this study has highlighted areas for improvement in the scenario development of some commonly used energy model frameworks. Finally, there is a complete lack of explanation regarding the stakeholder selection process. Addressing these identified items could increase opportunities for advanced energy technology uptake and improve our options for achieving a more resilient energy system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improved Muon Energy Estimation Using a Detailed Model of Multiple Coulomb Scattering in the MicroBooNE LArTPC

We present an improved technique for estimating a muon's energy by measuring the deflections along its path inside the MicroBooNE detector from multiple Coulomb scattering (MCS). This approach implements several innovations that better capture detector non-idealizations compared to previous MCS-based muon energy estimators. As a result, it achieves improved resolution, reduced bias, and better data-model agreement. Using model simulation, for fully contained events the estimated bias is within 1\% and the estimated resolution narrows from 10\% to 4.3\% as muon energy increases from 0.1\,GeV to 2\,GeV. For events with particles exiting the detector volume, at least a meter of reconstructed muon track, and a muon energy below 2\,GeV, the estimated bias is less than 2\% and the estimated resolution varies from 7\% to 17\% over muon energy. These demonstrate significant improvements over the performance of previous work using an MCS-based energy estimator at MicroBooNE~\cite{mcs_2017}, which exhibited approximately twice worse resolution and a bias of 20\% over the same energy region. Data-model goodness-of-fit studies are used to validate the estimator's performance on data, showing good agreement within model uncertainties.

Cooper-Troendle, London [U. Pittsburgh (main); Fer↗

Deadband Voltage Control and Power Buffering for Extreme Fast Charging Station

Voltage fluctuation is one of the most common challenges that electric vehicle charging station (EVCS) may introduce to the power grid. Local reactive power compensation (Q-compensation) capability of bi-directional electric vehicle (EV) chargers can mitigate the steady-state voltage violations caused by the EV charging itself or changes in the neighboring loads. Power buffering, using energy storage system (ESS), can be utilized to address the voltage transients (sags and swells) as a result of EV charging at the EVCS. To address PI controller’s ‘hunting’ issue, this paper proposes a Q-sign triggered deadband voltage control (V-control) method at the point of common coupling (PCC). In addition, to ensure the ramp rate of EV charging is within the allowable limits set forth by the grid code, a ramp rate control is proposed that uses the ESS as a ‘power buffer’. Lastly, different from most reported work in the literature where no explicit limit of the power electronic converters (PECs) is considered, this work considers a reasonable apparent power capacity limit of the PECs when achieving the V-control. This limit also affects the amount of active power that can be obtained from the grid, and subsequently may require ESS to function as ‘load sharing’ device to provide supplemental active power to satisfy EV load. A case study simulated in MATLAB (interfaced with PLECS) is presented to demonstrate the effectiveness of the proposed approaches for EVCS operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A review of prefabricated overclad panels for building energy retrofits

Over 50% of existing buildings in the US were constructed before 1980 and lack modern, energy-efficient technologies. Despite the large number of old buildings, less than 2% of buildings are retrofitted each year with many of those retrofits consisting of small incremental improvements that often ignore the building envelope. The opaque building envelope affects 25% of building energy use equating to 10% of total US primary energy use. To meet decarbonization goals by 2035, the US must increase the rate of retrofit of existing building envelopes. The process of prefabrication is one potential opportunity to increase the rate of envelope retrofits and reduce costs. Prefabrication is the process of manufacturing construction components in a controlled environment before shipping them on-site to perform assembly of the construction. The process of prefabrication has been demonstrated to increase production efficiency, quality control, and rate of production. Prefabricated overclad panels, consisting of a cladding material and insulation designed to be installed over the existing envelope, have been successfully used to retrofit existing buildings in countries other than the US; however, the technology still has some barriers to major market adoption within the US. This paper will present a review of current implementations and demonstrations of prefabricated overclad panels. The review will include identification of panel types, materials, and applications and aims to identify barriers to retrofit market entry and widespread adoption.

Hayes, Nolan [ORNL] (ORCID:0000000332245718)↗

An analysis of physics limited dispatch of nuclear renewable integrated energy systems using deep reinforcement learning and dynamic modeling

Previous approaches to dispatching nuclear integrated energy systems (NIES) have focused on the profitability and flexibility of these systems to operate on energy grids with highly variable pricing. However, due to the complexity involved in modeling and designing these systems, there has been less emphasis on ensuring that these dispatch strategies are physically achievable. It is imperative to develop methods that allow the system to remain within the desired NIES operating conditions and perform this based on realistic limited forecasted information. This research employs next generation artificial intelligence, namely deep reinforcement learning (DRL), and a dynamic system model written in Modelica to find a safe and profitable dispatch strategy for a solar nuclear hybrid design. The DRL agent is shown to find a novel dispatch strategy that manages both power ramping and power levels while respecting operational limits. This DRL-based dispatch is compared to other dispatching strategies including an optimal design solution from mixed integer linear programming (MILP). It is found that incorporating the physics of such a tightly coupled NIES limits the profitability of the MILP-based dispatch strategy. As a result, the MILP solution overestimates the design’s generated revenue. In contrast, DRL significantly reduces the number of breaches of safe operational conditions during energy arbitrage while maintaining profitability. Furthermore, this work paves the way for a more detailed assessment of NIES profitability and could be used to aid operator decisions on future NIES projects.

14 - SOLAR ENERGY↗

Optimizing Power Generation of a Bottom-Raised Oscillating Surge Wave Energy Converter Using a Theoretical Model: Preprint

Preliminary sizing of an oscillating surge wave energy converter (OSWEC) is an iterative process that relies on knowledge of the relevant hydrodynamic coefficients for a given geometry. Often, the complex definition of the device geometry requires coefficients to be obtained through experiments or numerical boundary element solvers such as WAMIT. These techniques demand significant user and computational effort, therefore inhibiting the fine scale parametrization of object dimensions. In this study, a theoretical model, originally presented in Michele et al. (2016), is developed and demonstrated to efficiently optimize the power production for an OSWEC device (subjected to certain environmental conditions) with variations in device widths, heights, and distances from the seabed. Assuming negligible device thickness, the OSWEC motions are modelled as a bottom-raised two-dimensional flap in regular waves using potential flow theory formulated in elliptical coordinates. The solutions to this diffraction-radiation problem are obtained using Mathieu functions with appropriate boundary conditions. The resulting potentials are then used to derive frequency-dependent expressions for the added mass and radiation damping coefficients, along with wave excitation magnitude in surge, pitch, and coupled surge-pitch motions. Good agreement in hydrodynamic coefficient curves is shown between the theoretical model and the numerical results obtained from the boundary element-based program WAMIT. The theoretical model is then employed to maximize the time-averaged output power while maintaining or reducing the hinge reaction force, with variations in device dimensions, wave frequency and amplitude.

ACE↗

Feasibility Analysis for the Use of Retrofitted Air-Conditioners Using Thermal Energy Storage (TES) for High Ambient Temperature (HAT) Countries

In high ambient temperature (HAT) countries, summer temperatures exceed 35℃, degrading the performance of air-conditioning systems and straining power grids. In this paper, a feasibility analysis was conducted to investigate potential savings during the peak using latent Thermal Energy Storage (TES) at near room phase-change temperatures, replacing condensers, thus, minimizing temperature lifts. Weather data, building loads, and baseline air-conditioning systems data were gathered for Dubai. A transient vapor-compression model in Modelica was used to compare the COP, total power input and cooling capacity of the air-conditioner at peak hours when ambient temperatures range between 35 – 45 ⁰C versus the TES-Phase-Change Material (PCM) melting temperatures from 22 – 28⁰C. The results indicate that the TES-PCM can enhance the system COP at the peak by a factor 1.4 and 2 for during for outdoor temperatures of 35 – 40⁰C, and 40 – 45⁰C, respectively. Lower melting temperature PCMs were able to reduce the required power input by 30-50%, with more savings occurring at higher temperature days. On the other hand, higher temperature PCMs enhancements were minimal especially at outdoor ambient temperatures ranging between 35 – 40⁰C. Improvements to the cooling capacity range from 8 – 18 % for the outdoor temperature range of 35 – 45 ⁰C. An economic analysis was conducted to find the potential saving in utility costs for 30%, 60%, and 90% of the space cooling demands of Dubai, and find the trade-off points between utility savings and cost of PCM-TES implementation. If the peak loads are to be shifted by 6 hours daily, the percentage utility savings for the city is 18%. Using estimated costs of the PCM-TES, ranging from $200-500/kWh, the daily load shifting hours were estimated to range from 4 hours at the lowest cost systems to 2.5 hours at the highest costs.

25 ENERGY STORAGE↗

City-Scale Building Anthropogenic Heating during Heat Waves

More frequent and longer duration heat waves have been observed worldwide and are recognized as a serious threat to human health and the stability of electrical grids. Past studies have identified a positive feedback between heat waves and urban heat island effects. Anthropogenic heat emissions from buildings have a crucial impact on the urban environment, and hence it is critical to understand the interactive effects of urban microclimate and building heat emissions in terms of the urban energy balance. Here we developed a coupled-simulation approach to quantify these effects, mapping urban environmental data generated by the mesoscale Weather Research and Forecasting (WRF) coupled to Urban Canopy Model (UCM) to urban building energy models (UBEM). We conducted a case study in the city of Los Angeles, California, during a five-day heat wave event in September 2009. We analyzed the surge in city-scale building heat emission and energy use during the extreme heat event. We first simulated the urban microclimate at a high resolution (500 m by 500 m) using WRF-UCM. We then generated grid-level building heat emission profiles and aggregated them using prototype building energy models informed by spatially disaggregated urban land use and urban building density data. The spatial patterns of anthropogenic heat discharge from the building sector were analyzed, and the quantitative relationship with weather conditions and urban land-use dynamics were assessed at the grid level. The simulation results indicate that the dispersion of anthropogenic heat from urban buildings to the urban environment increases by up to 20% on average and varies significantly, both in time and space, during the heat wave event. The heat dispersion from the air-conditioning heat rejection contributes most (86.5%) of the total waste heat from the buildings to the urban environment. We also found that the waste heat discharge in inland, dense urban districts is more sensitive to extreme events than it is in coastal or suburban areas. The generated anthropogenic heat profiles can be used in urban microclimate models to provide a more accurate estimation of urban air temperature rises during heat waves.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗