Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrical discharge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Lightning discharge identification system

A system for differentiating between cloud to cloud and cloud to ground lightning discharges is described which includes an electric field antenna that senses the rate of charge of an electric field produced by a lightning discharge. When the signal produced by the electric field exceeds a predetermined threshold, it is fed to a coincidence detector. A VHF antenna is also provided and generates a video signal responsive to a cloud to cloud lightning discharge, and this signal is fed through a level sensor, an inverter, to the coincidence detector simultaneously with the signal from the field detector. When signals from the electric field antenna and the VHF antenna appear at the coincidence detector simultaneously, such indicates that there is a cloud to cloud lightning discharge; whereas, when there is not a signal produced on the VHF antenna simultaneously with a signal produced by the field sensor, then a strike indicator connected to the coincidence detector indicates a cloud to ground lightning discharge.

Lennon, C. L.↗

The New NASA-STD-4005 and NASA-HDBK-4006, Essentials for Direct-Drive Solar Electric Propulsion

High voltage solar arrays are necessary for direct-drive solar electric propulsion, which has many advantages, including simplicity and high efficiency. Even when direct-drive is not used, the use of high voltage solar arrays leads to power transmission and conversion efficiencies in electric propulsion Power Management and Distribution. Nevertheless, high voltage solar arrays may lead to temporary power disruptions, through the so-called primary electrostatic discharges, and may permanently damage arrays, through the so-called permanent sustained discharges between array strings. Design guidance is needed to prevent these solar array discharges, and to prevent high power drains through coupling between the electric propulsion devices and the high voltage solar arrays. While most electric propulsion systems may operate outside of Low Earth Orbit, the plasmas produced by their thrusters may interact with the high voltage solar arrays in many ways similarly to Low Earth Orbit plasmas. A brief description of previous experiences with high voltage electric propulsion systems will be given in this paper. There are two new official NASA documents available free through the NASA Standards website to help in designing and testing high voltage solar arrays for electric propulsion. They are NASA-STD-4005, the Low Earth Orbit Spacecraft Charging Design Standard, and NASA-HDBK-4006, the Low Earth Orbit Spacecraft Charging Design Handbook. Taken together, they can both educate the high voltage array designer in the engineering and science of spacecraft charging in the presence of dense plasmas and provide techniques for designing and testing high voltage solar arrays to prevent electrical discharges and power drains.

Ferguson, Dale C.↗

Correlated Lightning Mapping Array (LMA) and Radar Observations of the Initial Stages of Florida Triggered Lightning Discharges

We characterize the geometrical and electrical characteristics of the initial stages of nine Florida triggered lightning discharges using a Lightning Mapping Array (LMA), a C-band SMART radar, and measured channel-base currents. We determine initial channel and subsequent branch lengths, average initial channel and branch propagation speeds, and channel-base current at the time of each branch initiation. The channel-base current is found to not change significantly when branching occurs, an unexpected result. The initial stage of Florida triggered lightning typically transitions from vertical to horizontal propagation at altitudes of 3-6 km, near the typical 0 C level of 4-5 km and several kilometers below the expected center of the negative cloud-charge region at 7-8 km. The data presented potentially provide information on thunderstorm electrical and hydrometeor structure and discharge propagation physics. LMA source locations were obtained from VHF sources of positive impulsive currents as small as 10 A, in contrast to expectations found in the literature.

Hill, J. D.↗

Partial discharge sensor

An approach to detecting partial discharge events involves retrofitting an electrical system to include a capacitive sensor configured to capacitively sense partial discharge events of a component of the electrical system. The capacitive sensor has a first electrical conductor that forms a first terminal of the capacitive sensor, a second electrical conductor that forms a second terminal of the capacitive sensor, and a dielectric that separates the first electrical conductor and the second electrical conductor. The capacitive sensor generates an electrical sensor signal at an output of the capacitive sensor in response to the partial discharge event. The electrical sensor signal is converted to an optical signal and the optical signal is processed to detect an occurrence of the partial discharge event.

Karin, Todd↗

Ozone Production by Corona Discharges During a Convective Event in DISCOVER-AQ Houston

An ozonesonde launched near electrically active convection in Houston, TX on 5 September 2013 during the NASA DISCOVER-AQ project measured a large enhancement of ozone throughout the troposphere. A separate ozonesonde was launched from Smith Point, TX (approx. 58 km southeast of the Houston site) at approximately the same time as the launch from Houston and did not measure that enhancement. Furthermore, ozone profiles for the descent of both sondes agreed well with the ascending Smith Point profile, suggesting a highly localized event in both space and time in which an anomalously large enhancement of 70 - 100 ppbv appeared in the ascending Houston ozonesonde data. Compared to literature values, such an enhancement appears to be the largest observed to date. Potential sources of the localized ozone enhancement such as entrainment of urban or biomass burning emissions, downward transport from the stratosphere, photochemical production from lightning NO(sub x), and direct ozone production from corona discharges were investigated using model simulations. We conclude that the most likely explanation for the large ozone enhancement is direct ozone production by corona discharges. Integrating the enhancement seen in the Houston ozone profile and using the number of electrical discharges detected by the NLDN (or HLMA), we estimate a production of 2.48 x 10(exp. 28) molecules of ozone per flash which falls within the range of previously recorded values (9.89 x 10(exp. 26) - 9.82 x 10)exp. 28) molecules of ozone per flash). Since there is currently no parameterization for the direct production of ozone from corona discharges we propose the implementation of an equation into a chemical transport model. Ultimately, additional work is needed to further understand the occurrence and impact of corona discharges on tropospheric chemistry on short and long timescales.

ozone↗

Spatiotemporal measurements of striations in a glow discharge’s positive column using laser-collisional induced fluorescence

Here we have observed the behavior of striations caused by ionization waves propagating in low-pressure helium DC discharges using the non-invasive laser-collision induced fluorescence (LCIF) diagnostic. To achieve this, we developed an analytic fit of collisional radiative model (CRM) predictions to interpret the LCIF data and recover quantitative two-dimensional spatial maps of the electron density, n e , and the ratios of LCIF emission states that can be correlated with T e with the use of accurate distribution functions at localized positions within striated helium discharges at 500 mTorr, 750 mTorr, and 1 Torr. To our knowledge, these are the first spatiotemporal, laser-based, experimental measurements of n e in DC striations. The n e and 447:588 ratio distributions align closely with striation theory. Constriction of the positive column appears to occur with decreased gas pressure, as shown by the radial n e distribution. We identify a transition from a slow ionization wave to a fast ionization wave between 750 mTorr and 1 Torr. These experiments validate our analytic fit of n e , allowing the implementation of an LCIF diagnostic in helium without the need to develop a CRM.

42 ENGINEERING↗

Baffle to confine glow discharge in ion pump

Electrically-grounded "optically tight' baffle installed downstream from conventional metal screen prevents discharge from entering test chamber and disturbing test process.

Wang, E. S. J.↗

Study on Electrostatic Separation of Quinoline Insolubles from Coal Tar Pitch

The feasibility of electrical separation in the removal of quinoline insoluble (QI) particles from coal tar pitch (CTP) was experimentally investigated. QI particle involvement prohibits the effective fabrication of high-quality value-added products, such as carbon fibers, from CTP. A substantial and sustainable CTP market exists around the world; therefore, a strong incentive exists to develop a viable technical approach to effectively and economically remove QI particles from CTP. The electrical separation method shows promise to achieve this technical goal (Cao et al., 2012). Even with the given setup (wire- cylinder adapted), critical issues remain to be addressed for this method to be applicable to the CTP: (1) identifying the wash oil used in the original QI separation, (2) understanding the mechanism of QI separation, (3) characterizing the deposit, and (4) identifying the QI. This study integrated a set of experimental and analysis techniques into the electrical separation tests to address the aforementioned issues. Key findings are as follows: 1. Electric current responses: • The electric current level of the CTP–wash oil solution reported by Cao et al. (2012) can be attained by using a mixture of 25% quinoline and 75% toluene for the CTPs examined in this study under the same electrical load condition. • The electric current tends to decrease during the test period because of the decreasing number of charged particles. • The reversed field corresponded to the configuration of electrostatic precipitation for positive corona discharge. The high electric field can result in dielectric breakdown and lead to an abrupt current surge. 2 Deposit response and solvent candidates: • Deposit of particles in CTP mixture can be effectively implemented in a wire-cylinder configuration as proposed and examined in this study. • Deposit depends on the solvents. Among the solvents tested, two- and three-part solvents that included quinoline and ethanol (i.e., 25% quinoline and 75% toluene; 50% quinoline and 50% toluene; and 33% wash oil, 33% BTX, and 34% ethanol) produced the highest deposit weight. • The deposit process examined in this study is derived from the charged particles. An appreciable relation exists between deposit weight and electric charge. 3. QI removal efficiency (RE): • The RE of the electrostatic separation can reach as high as 76.2% for Carbores, and 61.6% for Koppers. • The RE can be further enhanced if the field level increases from 0.16 kV/mm that was used in the current study to 0.23 kV/mm, according to the relation established between the RE and the electric field. 4. Testing of the modeling system: • The motion of particles is originally driven by the charge-based electric force in the cases tested. The solid particle separation mechanism is similar to that of QI deposition in CTP. • The mechanical movement of solid particles can be strongly affected by the gravitational and viscous forces in the electric field. 5. EDS analysis and chemical compositions: • The main chemical composition of deposit QI matches that of as-prepared CTP QI. The deposit QI is derived from the same group of the CTP QI. • In addition to carbon, the QI contains oxygen, sodium, aluminum, silicon, iron, and sulfur. The work for the near future is also discussed.

01 COAL, LIGNITE, AND PEAT↗

Electric charge build-up and dissipation at pulsed streamer corona by EFISH and probe measurements

The aim of this work is to study the dynamics of volumetric electric charge deposited by a single pin electrode streamer corona in atmospheric air at ambient conditions. Recent studies show that, at pulse-periodic operation, electric charge remains in surrounding air after the first discharge. This residual charge significantly impacts the electric field distribution and morphology of discharges at subsequent pulses. In this study, the residual electrical potential/field was measured during and after dissipation of a pulsed 80kV streamer corona of alternating polarity. This was accomplished using electrostatic probes and the EFISH method (Electric Field Induced Second Harmonic generation). The residual volumetric charge of a positive pulse polarity streamer corona occupies a zone up to 80mm from the electrode. The subsequent application of a negative polarity pulse leads to partial neutralization of the previous charge and the generation of a region with a high-amplitude electric field. Here, the propagation of following positive polarity pulses is limited by the residual positive volumetric charge. The EFISH method reveals the magnitude of the electric field at discharge propagation and electrostatic probes inform the polarity. Intensified imaging acquisition was used to evaluate the spatial distribution and dynamics of corona discharge during the alternating polarity waveform.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mitigating CaCO 3 crystal nucleation and growth through continuous ion displacement via alternating electric fields

Mineral crystal formation poses a challenge on surfaces (e.g., heat exchangers, pipes, membranes, etc.) in contact with super-saturated fluids. Applying alternating currents (AC) to such surfaces can prevent surface crystallization under certain conditions. Here, we demonstrate that ion displacement induced by periodic charging and discharging of the electrical double layer (EDL) inhibits both heterogeneous and homogeneous nucleation (and crystal growth) of CaCO 3 . Titanium sheets (meant to simulate metallic heat exchanger surfaces) are immersed in super-saturated CaCO 3 solutions with a saturation index >11. We show that at relatively high AC frequencies, incomplete EDL formation leads to an alternating electric field that propagates far into the bulk solution, inducing rapid ion migration that overwhelms the Brownian motion of ions. Electrochemical characterization reveals EDL charging/discharging under AC conditions that greatly inhibits precipitation. Operating at 4 V pp , 0.1–10 Hz reduces turbidity by over 96% and reduces CaCO 3 coverage on the metal plates by over 92%. Based on electrokinetic and crystallization models, the ion displacement velocity (exceeding the mean Brownian velocity) and displacement length disrupts ion collision and crystal nucleation. Overall, the technique has potential for preventing mineral crystal formation in heat exchangers and many other industrially relevant systems.

42 ENGINEERING↗

Optimization of a gas–liquid plasma reactor for water treatment applications: Design guidelines and electrical circuit considerations

To provide insights into the design, optimization, and scale up of plasma reactors for water treatment, the influences of discharge energy, grounded electrode size and position, and number of high voltage (HV) discharge points on the production of reactive species and the degradation of 1,4-dioxane and perfluorooctanoic acid in a gas–liquid electrical discharge plasma reactor were assessed. Discharge energy and plasma area largely control the treatment effectiveness. Increasing the number of discharge points lowers the voltage in the reactor and consequently the production rates of reactive species. Finally, bench-scale findings apply directly to large volume systems, resulting in the highest contaminant removal rates using a single HV electrode and a grounded electrode spanning the entirety of the treatment zone.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Behavior of Combined Dielectric-Metallic Systems in a Charged Particle Environment

The charging and discharging characteristics of an electrically isolated solar array segment were studied in order to simulate discharges seen during geomagnetic substorms. A solar array segment was floated while bombarded with monoenergetic electrons at various angles of incidence. The potentials of the array surface and of the interconnects were monitored using Trek voltage probes to maintain electrical isolation. A back plate was capacitively coupled to the array to provide information on the characteristics of the transients accompanying the discharges. Several modes of discharging of the array were observed at relatively low differential and absolute potentials (a few kilovolts). A relatively slow discharge response in the array was observed, discharging over one second with currents of nanoamps. Two types of faster discharges were also seen which lasted a few hundredths of a millisecond and with currents on the order of microamps. Some results indicate an electron emission process associated with the arcs.

Gordon, W. L.↗

Impact of CH 4 addition on the electron properties and electric field dynamics in a Ar nanosecond-pulsed dielectric barrier discharge

Non-equilibrium plasmas derive their low temperature reactivity from producing and driving energetic electrons and active species under large electric fields. Therefore, the impact of reactants on the plasma properties including electron number density, electric field, and electron temperature is critical for applications such as plasma CH 4 reforming. Due to experimental complexity, electron properties and the electric field are rarely measured together in the same discharge. Here, we combine time-resolved Thomson scattering and electric field induced second harmonic generation (EFISH) to probe electron temperature, electron density, and electric field strength in a 60 Torr CH 4 /Ar nanosecond-pulsed dielectric barrier discharge (ns-DBD) while varying the CH 4 mole fraction from 0 to 8%. These measurements are compared to a 1-D numerical model to benchmark its predictions and identify areas of uncertainty. Nonlinear coupling between CH 4 addition, electron temperature, electron density, and the electric field was directly observed. Contrary to previous measurements in He, the electron temperature increased with CH 4 mole fraction. This rise in electron temperature is identified as electron heating by residual electric fields that increased with larger CH 4 mole fraction. Moreover, the electron number density has been found to decrease rapidly with the increase of methane mole fraction. Comparison of these measurements with the model yielded better agreement at higher CH 4 mole fractions and with the usage of ab initio calculated Ar electron-impact cross-sections from the B-spline R-matrix (BSR) database. Furthermore, the calculated plasma properties are shown to be sensitive to the residual surface charge implanted on the quartz dielectric surfaces. Without considering surface charge in the simulations, the calculated electric field profiles agreed well with the measurements, but the electron properties were underpredicted by more than a factor of three. Therefore, measurements of either the electric field or electron properties measurements alone are insufficient to fully validate modelling predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Autonomous Inspection of Electrical Transmission Structures with Airborne UV Sensors - NASA Report on Dominion Virginia Power Flights of November 2016

The report details test and measurement flights to demonstrate autonomous UAV inspection of high voltage electrical transmission structures. A UAV built with commercial, off-the-shelf hardware and software, supplemented with custom sensor logging software, measured ultraviolet emissions from a test generator placed on a low-altitude substation and a medium-altitude switching tower. Since corona discharge precedes catastrophic electrical faults on high-voltage structures, detection and geolocation of ultraviolet emissions is needed to develop a UAV-based self-diagnosing power grid. Signal readings from an onboard ultraviolet sensor were validated during flight with a commercial corona camera. Geolocation was accomplished with onboard GPS; the UAV position was logged to a local ground station and transmitted in real time to a NASA server for tracking in the national airspace.

Moore, Andrew J.↗

Autonomous Inspection of Electrical Transmission Structures with Airborne UV Sensors and Automated Air Traffic Management

This report details test and measurement flights to demonstrate autonomous UAV (Unmanned Aerial Vehicle) inspection of high-voltage electrical transmission structures. A UAV built with commercial, off-the-shelf hardware and software, supplemented with custom sensors and logging software, measured ultraviolet (UV) emissions from a test generator placed on a low-altitude substation and a medium-altitude switching tower. Since corona discharge precedes catastrophic electrical faults on high-voltage structures, detection and geolocation of ultraviolet emissions is needed to develop a UAV-based self-diagnosing power grid. Signal readings from an onboard ultraviolet sensor were validated during flight with a commercial corona camera. Geolocation was accomplished with onboard GPS; the UAV position was logged to a local ground station and transmitted in real time to a NASA server for tracking in the national airspace. The method has practicality and relevance but not adequacy; either improved UAV position determination technology or increased sensor range is needed to enable broad deployment of this method.

Moore, Andrew J.↗

Electrostatic Discharge (ESD) of Aerospace Vehicles

This project is a follow-on work to a Science Innovation Fund (SIF) project to develop a new form of Paschen’s law that could relax current triboelectrification launch criteria by considering the effect of the flow of gas past aerospace vehicle surfaces. Paschen’s law, derived in 1889 by F. Paschen, calculates the minimum voltage required to create an electrical spark or discharge between two electrodes.

Michael D Hogue↗

Field and Model Data Associated with the Manuscript “Drivers of Streamflow Intermittency in Humid Regions: 2. Evaluating Controls on Flow Persistence in an Urbanized Catchment”

This package contains field data, modeling files, and scripts supporting the investigation of the drivers of streamflow intermittency in an urbanized catchment. It includes the field data collected from electrical resistivity tomography (ERT) surveys, distributed temperature sensing (DTS), continuous self-potential (SP) monitoring, groundwater and stilling well. In addition, it contains the data and results of the coupled water- and electrical-flow model developed using the COMSOL Multiphysics and Advanced Terrestrial Simulator (ATS), as well as software files and Jupyter notebooks used to process the data and generate figures in the manuscript submitted for peer review. The data archive is organized in the following directories: 1) Climate Includes hourly precipitation and daily evapotranspiration time series (2024 – 2025) provided as CSV files, alongside a text file detailing dataset units. 2) Coupled_model Field_Application subfolder contains the ATS XML input scripts, data files, output data for the SP site. It also contains the Jupyter notebook (Plot_final_calib.ipynb) to visualize the results of the modeled SP, stream-groundwater exchange and moisture content. The flow model simulation is executed using the ATS XML scripts and the included Python script (generate_data_set.py) to convert ATS output to COMSOL-ready input. COMSOL Multiphysics template (.m can only be used with COMSOL with MATLAB) is executed using the ATS output data to simulate the potential field. 3) Discharge Includes the electrical conductivity (EC) time series (provided as CSV files) from salt slug injections. It also includes the Jupyter notebook (Discharge_process.ipynyb) used to estimate discharge. All discharge measurements collated into rating_curve_processed.csv 4) DTS Contains collated DTS data including raw Stokes and anti-Stokes measurement (provided as .h5 file). It also includes DTS processing.ipynb, a Jupyter notebook for calibrating the DTS data using dts_calibration Python package. cooler_calibration.csv is the DTS calibration CSV used in the calibration sequence. 5) ERT Contains raw resistivity data (provided as CSV files), spatial location of each of the electrodes (provided as CSV files), and files used for the resistivity inversion. 6) Slug_test Includes the slug test data at all the groundwater wells provided as CSV files, as well as the Jupyter notebook (Slug_test.ipynb) for calculating hydraulic conductivity. 7) SP Contains the SP data collected in field at the SP sites (provided as CSV files). 8) Well_data Contains two subfolders: 1) Raw, which provides unprocessed pressure, electrical conductivity and temperature timeseries downloaded from the loggers in all the groundwater and stilling wells, and 2) Processed, which contains sorted, QA/QC timeseries data for each well. The data archive also contains data_process.ipynb, a Jupyter notebook used for field data analysis and generating figures (plotting well, SP, climate, and discharge data, as well as calculating head gradient at sites with nested groundwater wells). Note: Code files (.ipynb, .py, .xml) can be opened in any standard code editor, .exo file can be viewed using Paraview, .h5 files can be opened using HDFView software and h5py Python package, and .resipy file can be opened with the open-source ResIPy software.

ATS↗

Investigation of a Frequency Spectrum of Discharges Generated by a Charged Aerosol Cloud

Charged aerosol clouds allow to create strong electric fields which generate discharges. A character of appearance and development of the discharges is similar to thundercloud processes. That is why the charged aerosol clouds are used for experiments on studying of discharges in air. Experimental data on electromagnetic fields investigation produced by discharges between charged cloud and ground are considered.

Christian, H. J.↗