Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EPOXY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Postbuckling and failure characteristics of selected flat rectangular graphite-epoxy plates loaded in compression

Results of an experimental study of the postbuckling response and failure characteristics of 16- and 24-ply quasi-isotropic and 24-ply orthotropic flat rectangular graphite-epoxy plates loaded in compression are examined. Some of the specimens had circular drilled holes or were subjected to low-speed impact damage. The ratio of failure load to buckling load was found to be higher for specimens with lower initial buckling strains than for specimens with higher initial buckling strains. Some specimens supported more than five times their initial buckling load before failing. The specimens failed along a nodal line of the buckling mode in an induced shear failure mode. Holes and impact damage had a more adverse effect on the postbuckling strength of specimens with high initial buckling strains than on the strength of specimens with lower initial buckling strains.

Starnes, J. H., Jr.↗

The challenges of manufacturing graphite-epoxy structural columns for space platforms

A description is given of the manufacturing processes developed for large-quantity production of space structure graphite/epoxy composite tubes. The tubes are to be delivered to orbit by the Space Shuttle and assembled by astronaut-assisted assembly machines. The tooling and manufacturing system uses a novel method of dry fiber placement which carefully controls fiber position and orientation and a non-autoclave cure for the epoxy resin. The means of dimensional tolerance control over differential thermal expansion between metal tooling and graphite tubes, resin shrinkage during cure, hot pressurized resins in close tolerance tooling, and tool wear, are examined in detail. A successful pilot production program is also reported.

Vaughn, R. L.↗

Fire-Retardant Epoxy Adhesives

Phosphorus-containing epoxy is fire-retardant and translucent. Intended as adhesive for laminated plastic sheets, new material bonds well to titanium dioxide-filled plastic film, which ordinarily shows little surface interaction with adhesives. Fire retardancy has been demonstrated, and smoke density is low enough to avoid smoke obscuration.

Bilow, N.↗

The effect of resin on the impact damage tolerance of graphite-epoxy laminates

The effect of the matrix resin on the impact damage tolerance of graphite-epoxy composite laminates was investigated. The materials were evaluated on the basis of the damage incurred due to local impact and on their ability to retain compression strength in the presence of impact damage. Twenty-four different resin systems were evaluated. Five of the systems demonstrated substantial improvements compared to the baseline system including retention of compression strength in the presence of impact damage. Examination of the neat resin mechanical properties indicates the resin tensile properties influence significantly the laminate damage tolerance and that improvements in laminate damage tolerance are not necessarily made at the expense of room temperature mechanical properties. Preliminary results indicate a resin volume fraction on the order of 40 percent or greater may be required to permit the plastic flow between fibers necessary for improved damage tolerance.

Williams, J. G.↗

In-service inspection methods for graphite-epoxy structures on commercial transport aircraft

In-service inspection methods for graphite-epoxy composite structures on commercial transport aircraft are determined. Graphite/epoxy structures, service incurred defects, current inspection practices and concerns of the airline and manufacturers, and other related information were determind by survey. Based on this information, applicable inspection nondestructive inspection methods are evaluated and inspection techniques determined. Technology is developed primarily in eddy current inspection.

Phelps, M. L.↗

Ultrasonic and mechanical characterizations of fatigue states of graphite epoxy composite laminates

Eight-ply (0, + or - 45, 0)s laminates of Hercules AS/3501-6 graphite epoxy composite are fabricated using various cure pressures ranging from 0.52 to 0.86 MPa and cure temperatures ranging from 150 C to 200 C. In general, the minimum composite void volume fraction is obtained at a cure temperature of 175 C and a cure pressure of 0.86 MPa, or at 200 C and 0.86 MPa. The ultrasonic attenuation at 4 MHz was found to correlate with the composite void volume fraction. Composite specimens were tested in flexural fatigue. Beyond 10,000 fatigue cycles, the ultrasonic attenuation at 4 MHz was found to increase and the flexural stiffness was found to decrease. The ultrasonic attenuation at 4 MHz of the as-fabricated composite can be correlated with the number of fatigue cycles to failure.

Williams, J. H., Jr.↗

The effects of electron and gamma radiation on epoxy-based materials

Specimens of graphite/epoxy composites and epoxy resins were exposed to electron and gamma radiation, followed by mechanical property and fundamental measurements. Measurement techniques included: scanning electron microscopy, X-ray diffraction analysis, and electron spin resonance spectroscopic analysis. Results indicate little or no change in flexural properties of miniature specimens of a graphite/epoxy composite and no change in failure mode at the fiber-resin interface and in the crystallinity of the fiber and the resin. Some doubt in the observation of stable flexural properties is cast by electron paramagnetic resonance spectra of a relatively large number of radiation-generated radicals. These generally lead to a change in cross-linking and in chain-scissioning which should alter mechanical properties.

Fornes, R. E.↗

Pulsed radiolysis of model aromatic polymers and epoxy based matrix materials

Models of primary processes leading to deactivation of energy deposited by a pulse of high energy electrons were derived for epoxy matrix materials and polyl-vinyl naphthalene. The basic conclusion is that recombination of initially formed charged states is complete within 1 nanosecond, and subsequent degradation chemistry is controlled by the reactivity of these excited states. Excited states in both systems form complexes with ground state molecules. These excimers or exciplexes have their characteristics emissive and absorptive properties and may decay to form separated pairs of ground state molecules, cross over to the triplet manifold or emit fluorescence. ESR studies and chemical analyses subsequent to pulse radiolysis were performed in order to estimate bond cleavage probabilities and net reaction rates. The energy deactivation models which were proposed to interpret these data have led to the development of radiation stabilization criteria for these systems.

Gupta, A.↗

The effects of microcracking on the thermal expansion of graphite-epoxy composites

A study of the effects of thermal environment and microcracking in graphite epoxy composites was made. Research indicates that microcracking does affect the thermal expansion of composite laminates. The amount of reduction in thermal expansion was a function of the crack density. A maximum reduction of approximately 25% occurred in a quasi-isotropic specimen with a crack density of 2.05 mm 1 in the 90 deg plies. Laminate analysis with appropriate reductions in E sub 2 and Alpha sub 2 of the damaged plies appears to be capable of modeling the observed

Bowles, D. E.↗

Thermal expansion of graphite-epoxy between 116 K and 366 K

A Priest laser interferometer was developed to measure the thermal strain of composite laminates. The salient features of this interferometer are that: (1) it operates between 116 K and 366 K; (2) it is easy to operate; (3) minimum specimen preparation is required; (4) coefficients of thermal expansion in the range of 0-5 micro epsilon/K can be measured; and (5) the resolution of thermal strain is on the order of micro epsilon. The thermal response of quasi-isotropic, T300/5208, grahite-epoxy composite material was studied with this interferometer. The study showed that: (1) for the material tested, thermal cycling effects are negligible; (2) variability of thermal response from specimen to specimen may become significant at cryogenic temperatures; and (3) the thermal response of 0.6 cm and 2.5 cm wide specimens are the same above room temperature.

Short, J. S.↗

Design detail verification tests for a lightly loaded open-corrugation graphite-epoxy cylinder

Flat corrugated graphite-epoxy panels were tested in compression to verify selected design details of a ring-stiffened cylinder that was designed to support an axial compressive load of 157.6 kN/m without buckling. Three different sizes of subcomponent panels, with the same basic corrugation geometry, were tested: (1) 60.96-cm-long by 45.72-cm-wide panels to evaluate the local buckling strength of the shell wall design; (2) 91.44-cm-long by 45.72-cm-wide panels to evaluate a longitudinal joint and the load-introduction method; and (3) 254.0-cm-long by 91.44-cm-wide panels with four simulated-ring stiffeners to evaluate the ring-attachment method. The test results indicate that the modified shell-wall design, the longitudinal joint, the load-introduction method, and the stiffener-attachment method for the proposed cylinder have adequate strength to support the design load.

Davis, R. C.↗

Flight service evaluation of Kevlar-49 epoxy composite panels in wide-bodied commercial transport aircraft

Kevlar-49 fairing panels, installed as flight service components on three l-1011's, were inspected after 8 years service. The fairings had accumulated a total of 62,000 hours, with one ship set having 20,850 hours service. Kevlar-49 components were found to be performing satisfactorily in service with no major problems. The only defects noted were minor impact damage, a few minor disbonds and a minor degree of fastener hole fraying and elongation. The service history to date indicates that Kevlar-49 epoxy composite materials have satisfactory service characteristics for use in aircraft secondary structures.

Stone, R. H.↗

Development of quality assurance methods for epoxy graphite prepreg

Quality assurance methods for graphite epoxy/prepregs were developed. Liquid chromatography, differential scanning calorimetry, and gel permeation chromatography were investigated. These methods were applied to a second prepreg system. The resin matrix formulation was correlated with mechanical properties. Dynamic mechanical analysis and fracture toughness methods were investigated. The chromatography and calorimetry techniques were all successfully developed as quality assurance methods for graphite epoxy prepregs. The liquid chromatography method was the most sensitive to changes in resin formulation. The were also successfully applied to the second prepreg system.

Chen, J. S.↗

Woven graphite epoxy composite test specimens with glass buffer strips

Woven unidirectional graphite cloth with bands of fiberglass replacing the graphite in discrete lengthwise locations was impregnated with epoxy resin and used to fabricate a series of composite tensile and shear specimens. The finished panels, with the fiberglass buffer strips, were tested. Details of the fabrication process are reported.

Bonnar, G. R.↗

Buckling test of a 3-meter-diameter corrugated graphite-epoxy ring-stiffened cylinder

A three m diameter by three m long corrugated cylindrical shell with external stiffening rings was tested to failure by buckling. The corrugation geometry for the graphite epoxy composite cylinder wall was optimized to withstand a compressive load producing an ultimate load intensity of 157.6 kN/m without buckling. The test method used to produce the design load intensity was to mount the specimen as a cantilevered cylinder and apply a pure bending moment to the end. A load introduction problem with the specimen was solved by using the BOSOR 4 shell of revolution computer code to analyze the shell and attached loading fixtures. The cylinder test loading achieved was 101 percent of design ultimate, and the resulting mass per unit of shell wall area was 1.96 kg/sq m.

Davis, R. C.↗

Space environmental effects: Construction and utilization of a system to measure low thermal strain in one meter graphite epoxy tubes

A system for measuring the expansion of low coefficient of thermal expansion (CTE) materials was constructed around a H.P. 5526-A laser measuring system. The vacuum CTE measurements in the -150 F to +120 F range were made over a 6 month period on a graphite epoxy tube yielding CTE values of 2.5 to one fifty-millionth/F above ambient and 2 + or - one ten-millionth F below ambient temperature. To assure that the below ambient, approximately 10 microns high open loop nature of the delta L/L vs. T curves was not apparatus related, similar size quartz tubes (A and B) were checked and found to have only a 2 micron (negligable for quartz) open loop component. These two quartz tubes, A and B, had ambient CTE values 20% and 45% respectively higher than the average handbook value. The overnight microcreep diminished an order of magnitude during the first several cycles after the system had been reopened.

Davis, J. H.↗

Effect of orthotropic properties and panel width on the compression strength of graphite-epoxy laminates with holes

An experimental study conducted to evaluate the effect of laminate orthotropic properties and panel width on the compression strength of 48-ply graphite-epoxy laminates with drilled holes is described. The test results are evaluated on the basis of hole size and specimen width and are used in determining parameters necessary for predicting trends using the point stress failure criterion. Good agreement is obtained between experimental and predicted values of failure for panels fabricated from two quasi-isotropic laminates and one orthotropic laminate. The results suggest that panels of different widths having holes that are large in relation to the failure prediction parameter should be included in any test program conducted to develop prediction trends that may be used in design applications.

Rhodes, M. D.↗

Postbuckling behavior of selected flat stiffened graphite-epoxy panels loaded in compression

Results of an experimental study of the postbuckling behavior of selected flat stiffened graphite-epoxy panels loaded in compression are presented. The postbuckling response and failure characteristics of undamaged panels and panels damaged by low-speed impact are described. Each panel had four equally-spaced I-spaced stiffeners and 16- or 24-ply quasi-isotropic skins. Panels with three different stiffener spacings were tested. Some undamaged specimens supported as much as three times their initial buckling load before failing. Failure of all panels initiated in a skin-stiffener interface region. Analytical results obtained from a nonlinear general shell finite element analysis computer code correlate well with typical postbuckling test results up to failure. The analytical modeling detail necessary to predict accurately the response of a panel is described. Test results show that low-speed impact damage can reduce the postbuckling strength of a stiffened panel and that the skin-stiffener interface region is more sensitive to impact damage than the skin midway between stiffeners.