The effects of chronic diseases on plutonium urinary excretion in former workers of the Mayak Production Association

The radiochemical analysis of plutonium activity in urine is the main method for indirect estimation of doses of internal exposure from plutonium incorporation in professional workers. It was previously shown that late-in-life acute diseases, particularly those that affect the liver, can promote accelerated rates of release of plutonium from the liver with enhanced excretion rates. This initial study examines the relationships of some chronic diseases on plutonium excretion as well as the terminal relative distribution of plutonium between the liver and skeleton. Fourteen cases from former workers at the Mayak Production Association (Mayak PA) who provided from 4–9 urine plutonium bioassays for plutonium, had an autopsy conducted after death, and had sufficient clinical records to document their health status were used in this study. Enhanced plutonium excretion was associated with more serious chronic diseases, including cardiovascular diseases and other diseases that involved the liver. These chronic diseases were also associated with relatively less plutonium found in the liver relative to the skeleton determined by analyses conducted after autopsy. These data further document health conditions that affect plutonium biokinetics and organ deposition and retention patterns and suggest that health status should be considered when conducting plutonium bioassays as these may alter subsequent dosimetry and risk models.

60 APPLIED LIFE SCIENCES↗

Results of a Multi-institutional Phase 2 Clinical Trial for 4DCT-ventilation Functional Avoidance Thoracic Radiation Therapy

Radiation pneumonitis remains a major limitation in the radiation therapy treatment of patients with lung cancer. Functional avoidance radiation therapy uses functional imaging to reduce pulmonary toxic effects by designing radiation therapy plans that reduce doses to functional regions of the lung. Lung functional imaging has been developed that uses 4-dimensional computed tomography (4DCT) imaging to calculate 4DCT-based lung ventilation (4DCT-ventilation). A phase 2 multicenter study was initiated to evaluate 4DCT-ventilation functional avoidance radiation therapy. The study hypothesis was that functional avoidance radiation therapy could reduce the rate of grade ≥2 radiation pneumonitis to 12% compared with a 25% historical rate, with the trial being positive if ≤16.4% of patients experienced grade ≥2 pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Comparison of Irradiated and Unirradiated Graphite Oxidation Performance

This work examines the oxidation behavior of NBG-25 graphite using irradiated specimens and (not irradiated) companion specimens from the Advanced Graphite Creep (AGC) Experiment. Irradiated and companion specimens were quartered, split into four small samples, to enable four oxidation test runs for each (0.5 inch diameter by 0.25 inch tall) piggyback button obtained from the AGC Experiment inventory. These split samples were oxidized in air in a thermogravimetric analyzer (TGA) and benchmarked against observations with separately sourced same-grade specimens of three geometries oxidized either in the TGA or in a vertical furnace built and operated to satisfy the specifications of ASTM D7542. The study considers both irradiation damage and relief of damage by thermal annealing. A range of isothermal oxidation temperatures were tested for specimens exposed to a similar irradiation environment, nominally 6.5 dpa at 650°C. To assess the dose dependency of observed oxidation behavior, specimens with a range of irradiation exposures (up to 6.8 dpa) were tested at the single oxidation temperature of 650°C. In the conventional analysis (rate determined over the 5-10% mass loss range) any annealing effects appear to be negligible, while irradiation to ~6.5 dpa may double or triple the subsequent oxidation rate. However, examination of rate with extent of reaction (over incremental ranges from initial onset up to 5% mass loss) illustrates that (at least for ~6.5 dpa) irradiation initially inhibits oxidation. Slower rates of oxidation than companion split samples are clearly indicated across all oxidation temperatures tested up to ~0.5% mass loss. Over the range of 0.5-1% mass loss, regardless of normalization strategy, there is no statistically meaningful difference in oxidation rate. However, beyond 0.5% mass loss oxidation of the irradiated sample becomes progressively faster than the companion sample (up to the 10% mass loss level observed).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-throughput screening tools facilitate calculation of a combined exposure-bioactivity index for chemicals with endocrine activity

High-throughput and computational tools provide a new opportunity to calculate combined bioactivity of exposure to diverse chemicals acting through a common mechanism. We used high throughput in vitro bioactivity data and exposure predictions from the U.S. EPA’s Toxicity and Exposure Forecaster (ToxCast and ExpoCast) to estimate combined estrogen receptor (ER) agonist activity of non-pharmaceutical chemical exposures for the general U.S. population. High-throughput toxicokinetic (HTTK) data provide conversion factors that relate bioactive concentrations measured in vitro (µM), to predicted population geometric mean exposure rates (mg/kg/day). These data were available for 22 chemicals with ER agonist activity and were estimated for other ER bioactive chemicals based on the geometric mean of HTTK values across chemicals. For each chemical, ER bioactivity across ToxCast assays was compared to predicted population geometric mean exposure at different levels of in vitro potency and model certainty. Dose additivity was assumed in calculating a Combined Exposure-Bioactivity Index (CEBI), the sum of exposure/bioactivity ratios. Combined estrogen bioactivity was also calculated in terms of the percent maximum bioactivity of chemical mixtures in human plasma using a concentration-addition model. Estimated CEBIs vary greatly depending on assumptions used for exposure and bioactivity. In general, CEBI values were <1 when using median of the estimated general population chemical intake rates, while CEBI were ≥1 when using the upper 95th confidence bound for those same intake rates for all chemicals. Concentration-addition model predictions of mixture bioactivity yield comparable results. Based on current in vitro bioactivity data, HTTK methods, and exposure models, combined exposure scenarios sufficient to influence estrogen bioactivity in the general population cannot be ruled out. Future improvements in screening methods and computational models could reduce uncertainty and better inform the potential combined effects of estrogenic chemicals.

54 ENVIRONMENTAL SCIENCES↗

Investigation of sCVD diamond detectors for low energy heavy-ion reactions

Here the performance characteristics of single-crystalline diamond detectors at varying rates of heavy-ions below 50 MeV/u have been investigated. When tested with a 228 Th source, the energy resolution of these detectors is better than 1.0% FWHM for 8.8 MeV α-particles. With a slight reduction in the energy resolution, simultaneous timing resolution of 314 ps has been achieved. Isotopic resolution has been achieved up to magnesium using a diamond telescope at low rates with a 20 MeV/u 20 Ne + 12 C reaction. At moderate rates of direct 7.5 MeV/u 78 Kr, polarization effects are observed, though this effect can be diminished by increasing the applied voltage on the detector up to a limit. After an accumulated dose of 6.9 × 10 8 direct 78 Kr particles transmitting through the detector, a degradation in the energy resolution of the 8.8 MeV peak from 1.6% to 5.3% is observed, indicating that permanent damage has been done to the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Void shrinkage in 21Cr32Ni austenitic model alloy during in-situ ion irradiation

Austenitic 21Cr32Ni model alloy thin foils, previously irradiated with 5 MeV Fe ++ ions in bulk to create voids, were re-irradiated in-situ in the Intermediate Voltage Electron Microscope Facility (IVEM). The voids which had been formed under bulk-ion irradiation shrank and disappeared after in-situ Kr ion irradiation in the temperature range 50 K-713 K to an additional dose of 1 dpa. The voids were unaffected by eithersuccessive thermal annealing to 673 K and by prolonged exposure to the 200 keV electron beam at the irradiation temperature. The high void shrinkage rate observed did not change significantly for irradiation temperatures between 50 K and 713 K, suggesting that the void shrinkage process in thin foils during in-situ heavy-ion irradiation results from the interactions of displacement cascades with the voids. Finally, possible void shrinkage mechanisms under thin foil irradiation are discussed in this study.

36 MATERIALS SCIENCE↗

The role of Cr concentration and temperature on cavity swelling with co-injected helium in dual-ion irradiated Fe and Fe-Cr alloys

The level of chromium plays an essential role in irradiation tolerance of Fe-Cr ferritic alloys. However, conflicting results have been reported regarding the dependence of cavity swelling under irradiation on Cr level and temperature. Here, we have performed a comprehensive set of simultaneous dual-ion (Ni + He) irradiations to high dose (~30 displacements per atom, dpa) at 400–550 °C on a series of ultra-high purity Fe and Fe-Cr binary alloys (3–14 wt.%Cr). Helium co-implantation rates of 0.1 and 10 appm He/dpa were selected to examine He synergistic effects relevant for fission and fusion reactor conditions, respectively. Cavities were observed in all irradiated samples by transmission electron microscopy. The results show that higher He implantation rate causes a shift in the swelling peak to higher temperatures in both Fe and Fe-Cr alloys. When assuming smaller cavities as biased sinks, the non-monotonic nature of the cavity swelling behavior is related to the ratio of biased to unbiased point defect sink strengths. Cr-enriched precipitates were observed in Fe-14Cr irradiated at 400 °C by atom probe tomography. Our analysis suggests the formation of Cr-enriched precipitates could suppress cavity swelling for Fe-Cr alloys with Cr content above 10 wt%.

36 MATERIALS SCIENCE↗

Long-Term Cycling of a Mn-Rich High-Voltage Spinel Cathode by Stabilizing the Surface with a Small Dose of Iron

The high-voltage, cobalt-free spinel cathode LiNi 0.5 Mn 1.5 O 4 (LNMO) is receiving extensive attention for lithium-ion batteries due to its low cost, high operating voltage and energy density, superior power density, and good thermal stability. However, its high operating voltage hampers its stability with commercial electrolytes and makes its practical viability challenging. We present here a Mn-rich LNMO cathode to encourage the disordering of Mn and Ni in the lattice and the incorporation of a small dose of Fe into Mn-rich LNMO (Fe-LNMO) to improve the cycling stability. The introduction of Fe further increases the cation disorder between Mn and Ni, thus enabling a better rate capability. Electron energy loss spectroscopy analysis indicates that Fe is concentrated on the surface, and X-ray photoelectron spectroscopy analysis shows that Fe-LNMO alleviates the aggressive reaction between the cathode surface and the electrolyte, thus stabilizing the interface and cycle life. Furthermore, a full cell assembled with a graphite anode with an areal capacity of 3 mA h cm –2 displays a capacity retention of 90% over 300 cycles. Furthermore, the present work demonstrates an effective way to promote cation disordering and lower the surface reactivity of LNMO with the electrolyte, thereby enhancing the conductivity, stabilizing the cathode–electrolyte interphase, and making LNMO promising for practical applications.

25 ENERGY STORAGE↗

Impact of developmental methylmercury exposure on avian embryonic development, hatchling growth, and survival

Abstract Methylmercury (MeHg) is a globally ubiquitous and persistent environmental toxicant that negatively affects animal behavior, health, and reproduction. In birds, MeHg is transferred from female to egg, contaminating embryos during sensitive stages of early embryonic development and growth. This toxic exposure in the prenatal environment not only induces mortality but also possible lasting impacts on physiology, health, and survival, even once hatched. The purpose of our study was to further elucidate the negative effects of MeHg exposure during avian embryonic development and explore how such exposure can impact offspring development, growth, and survival, both in ovo and posthatch. To assess this, we experimentally dosed fertile mallard and wood duck eggs with MeHg II chloride and reared developing embryos and ducklings to various endpoints. We found that embryos not only readily accumulated MeHg throughout incubation, but they also displayed varying dose-dependent disparities in body mass and morphometrics, with control individuals being larger during early and late embryonic stages of development (p < 0.05). Furthermore, hatched offspring exposed to MeHg exhibited increasingly slower growth rates between 7 to 10 and 10 to 15 days posthatch (p < 0.05), and were found to have lower survival probabilities both under controlled laboratory conditions (p < 0.005), and in the natural environment (p < 0.05). Our findings on the detrimental effects of MeHg on avian embryos and hatchlings emphasize the need for more proactive means of environmental protection and remediation to protect vulnerable avian populations and the ecosystems they inhabit.

Leaphart, James C.↗

Identifying the gene responsible for non‐photochemical quenching reversal in Phaeodactylum tricornutum

SUMMARY Algae such as diatoms and haptophytes have distinct photosynthetic pigments from plants, including a novel set of carotenoids. This includes a primary xanthophyll cycle comprised of diadinoxanthin and its de‐epoxidation product diatoxanthin that enables the switch between light harvesting and non‐photochemical quenching (NPQ)‐mediated dissipation of light energy. The enzyme responsible for the reversal of this cycle was previously unknown. Here, we identified zeaxanthin epoxidase 3 (ZEP3) from Phaeodactylum tricornutum as the candidate diatoxanthin epoxidase. Knocking out the ZEP3 gene caused a loss of rapidly reversible NPQ following saturating light exposure. This correlated with the maintenance of high concentrations of diatoxanthin during recovery in low light. Xanthophyll cycling and NPQ relaxation were restored via complementation of the wild‐type ZEP3 gene. The zep3 knockout strains showed reduced photosynthetic rates at higher light fluxes and reduced specific growth rate in variable light regimes, likely due to the mutant strains becoming locked in a light energy dissipation state. We were able to toggle the level of NPQ capacity in a time and dose dependent manner by placing the ZEP3 gene under the control of a β‐estradiol inducible promoter. Identification of this gene provides a deeper understanding of the diversification of photosynthetic control in algae compared to plants and suggests a potential target to improve the productivity of industrial‐scale cultures.

Ware, Maxwell A.↗

Assessment of Potential Dose and Environmental Impacts from Proposed Testing at the INL Radiological Response Training Range

This assessment uses screening-level models to calculate potential environmental impacts from proposed tests at the Idaho National Laboratory (INL) Radiological Response Training Range (RRTR) site. Proposed tests could be conducted using 11 different radioactive material types that include K2O, LaBr3, KBr, Cu, Zr, F, Ga, Ga2O3, NaNO2, Ga-68, and Tc-99m. The tests could potentially release radioactive material to the atmosphere and radionuclides and other contaminants to the soil, which could leach into the unsaturated zone and migrate to the aquifer. Atmospheric transport of radionuclides to potential human receptors and time-integrated air concentrations were calculated with a Gaussian plume model and three years of hourly meteorological data. Potential surface-soil impacts were calculated with the computer program mixing-cell model (MCM). Groundwater impacts were calculated with the computer programs MCM and GWSCREEN. Radiological doses from potential atmospheric releases were calculated for public receptors off the INL Site and for workers at nearby INL facilities. Results were compared to regulatory dose limits. Maximum potential groundwater concentrations were estimated in the aquifer below the NSTR site and compared to drinking water standards or risk-based screening levels for resident tap water. Soil concentrations were calculated and compared to risk-based screening levels for workers and potential future residents. All impacts were estimated assuming 12 tests are conducted annually using all 11 material types for a period of 15 years. This document provides the resources to enable a subject matter expert in the field of environmental assessments to replicate the modeling and calculations. The methodology and parameters are presented in the text. All electronic files, including computer-code input, output, executable files, batch files, scripts, and spreadsheet files are contained in a zip file that can be accessed by selecting “Additional Information” (select Native File) in the INL Electronic Document Management System (EDMS). It is highly unlikely the test scenarios evaluated in this ECAR will adversely impact human health based on comparisons of calculated dose and concentration against regulatory standards and risk-based screening levels. Conservative estimates of dose to workers and the public from atmospheric transport of possible radionuclide releases are far below federal radiation protection standards. Conservative estimates of potential contaminant concentrations in groundwater are less than federal drinking water standards or screening levels. Predicted radionuclide concentrations in surface soils are below risk-based screening levels, except for Ge-68 (material Ga-68) for the worker. The Ge-68 soil concentration can be made less than the worker PRG, if the number of annual tests using Ga-68 is reduced from 12 to 6. However, the sum of ratios still exceeds one because of the high K-40 ratio. If the EF of the worker (number of days the worker is in the contaminated testing area) is reduced from 225 days/yr (default value for full time worker) to 112 days/yr, the Ge-68 ratio is less than one and the sum of ratios is less than one. Actual radiation doses and groundwater and surface-soil concentrations are likely to be much less than those calculated because of the conservative assumptions and parameters employed in the modeling. For example, atmospheric-transport calculations assume the entire inventory of each material type is readily released to the atmosphere and no plume deposition, depletion, or radioactive decay occurs during transport. The calculations also assume the same meteorological conditions (e.g., wind velocity, wind direction, stability class) that produce the maximum 95th percentile concentration (i.e., concentration representing the 95th percentile of a distribution of concentrations derived from 3 years of hourly meteorological data) at each receptor location are the same for all 12 tests during the year, and each receptor is assumed to be present during all 12 tests. The surface-soil assessment assumes the entire inventory of each test is deposited in the top 5 cm of soil. No atmospheric dispersal is assumed, and the radionuclides are subject only to leaching and radioactive decay. The groundwater-pathway modeling is conservative in that it is one-dimensional in the unsaturated zone (no lateral spreading/dilution) and assumes the entire inventory of contaminants infiltrates into the ground at the same location for every test. This is especially conservative for particulate radionuclides because they would have to dissolve or corrode first and some would be dispersed into the atmosphere. The groundwater receptor is also assumed to consume water directly from a hypothetical well positioned in the location of maximum concentration. In addition, conservative degradation rates were used, and volatilization was not considered for the nonradioactive chemical

54 ENVIRONMENTAL SCIENCES↗

Total-Ionizing-Dose Effects on Read Noise of MLC 3-D NAND Memories T

This paper analyzes the total ionizing dose (TID) effects on noise characteristics of commercial multi-level-cell (MLC) 3-D NAND memory technology during the read operation. Additionally, the chips were exposed to a Co-60 gamma-ray source for up to 100 krad(Si) of TID. We find that the number of noisy cells in the irradiated chip increases with TID. Bit-flip noise was more dominant for cells in an erased state during irradiation compared to programmed cells.

3-D NAND Flash↗

Photoinitiated Olefin Metathesis and Stereolithographic Printing of Polydicyclopentadiene

Recent progress in photoinitiated ring-opening metathesis polymerization (photoROMP) has enabled the lithographic production of patterned films from olefinic resins. Recently, we reported the use of a latent ruthenium catalyst (HeatMet) in combination with a photosensitizer (2-isopropylthioxanthone) to rapidly photopolymerize dicyclopentadiene (DCPD) formulations upon irradiation with UV light. While this prior work was limited in terms of catalyst and photosensitizer scope, a variety of alternative catalysts and photosensitizers are commercially available that could allow for tuning of thermomechanical properties, potlifes, activation rates, and irradiation wavelengths. Herein, 14 catalysts and 8 photosensitizers are surveyed for the photoROMP of DCPD and the structure–activity relationships of the catalysts examined. Properties relevant to stereolithography additive manufacturing (SLA AM)-potlife, irradiation dose required to gel, conversion-are characterized to develop catalyst and photosensitizer libraries to inform development of SLA AM resin systems. Two optimized catalyst/photosensitizer systems are demonstrated in the rapid SLA printing of complex, multidimensional pDCPD structures with microscale features under ambient conditions.

36 MATERIALS SCIENCE↗

Irradiation-induced gas production in REBCO-based magnet materials used for future compact fusion reactors

Nuclear fusion is an enticing alternative to current sources of energy, with multilayered Rare-Earth Barium Copper Oxide (REBCO) coated conductors deemed pivotal in the race toward fully realized, commercially viable, and magnetic confinement fusion reactors. In this study, we simulated the ion spectrum expected to evolve from REBCO's nickel-based Hastelloy C-276 substrate and copper stabilizer in an affordable robust compact-like reactor. We then emulated this gas production through helium implantation to investigate changes in materials and superconducting properties. Our results revealed that the substrate and stabilizer are capable of producing protons energetic enough to recoil throughout the tape thickness in appreciable doses, and alphas energetic enough to deposit 7.54 × 1014 ions/cm2 or 50.1 helium appm in the superconducting layer over a 30-year reactor lifetime. The superconducting layer of SuperPower® tapes exhibited at least double the swelling rate of the other major layers, and both SuperPower and Fujikura Ltd. tapes displayed microstructural changes in the REBCO layer not observed in isotropic metals. For the estimated lifetime fluence, the Fujikura tapes showed a ∼1 K reduction in critical temperature and a 32% degradation in critical current for compact reactor-relevant conditions (16 T, 20 K). Nuclear transmutation, low-temperature solder implantations, gas-ion evolution, the influence of gas production on vortex dynamics, and other related considerations are also discussed.

Reis, Chris↗

Statistical Uncertainty of Inhalation Dose Coefficients: Impact of Particle Deposition in ICRP 66 Human Respiratory Tract Model

Inhaled radioactive materials can pose a long-term health concern, as the material can be incorporated into the body’s metabolic pathways and remain in organs and tissues for extended durations. During the retention period, the radioactive material may localize in a source organ and irradiate adjacent target organs and tissues. Distribution of these materials changes over time, requiring biokinetic modeling to evaluate their movement through various tissues and organs. The evolving distribution depends on multiple inputs characterizing the inhaled material, such as particle size and size distribution, particle density, aspect ratio, specific radionuclide, the chemical form, and solubility. In addition, biological parameters such as breathing rate, breathing type (nasal or nasal/oral), respiratory system morphometry, tidal volume, functional residual capacity, and anatomical dead space all influence material transport. These aerosol properties and physiological characteristics of the respiratory tract jointly define a range of initial conditions that influence the time-dependent distribution of radioactive material. To evaluate both uncertainty in the initial conditions of inhalation exposure and the final output (committed effective dose) from biokinetic models, a Python-based software tool, Radiological Exposure Dose Calculator (REDCAL), was developed to propagate uncertainty within the human respiratory tract model. Focusing on deposition fraction uncertainty, the primary objective was to characterize the initial activity distribution across respiratory regions as a function of anticipated particle sizes and distributions. The impact of the deposition fraction uncertainty was propagated to committed effective dose coefficients for selected radionuclides in a companion publication. For each particle size, a lognormal distribution, characterized by its geometric mean as defined within ICRP Publication 66, serves as the basis for introducing uncertainty into the physical processes governing deposition in various lung regions. Finally, this study addresses the deposition process and examines how uncertainty in deposition mechanisms affects activity distribution in the airways, ultimately presenting the expected range and standard deviation of deposited activity as a function of particle size.

International Commission on Radiological Protectio↗

Changing bioavailability of per- and polyfluoroalkyl substances ($\mathrm{PFAS}$) to plant in biosolids amended soil through stabilization or mobilization

Biosolids containing per- and polyfluoroalkyl substances (PFAS) could contaminate the receiving environments once they are land applied. In this report, we evaluated the feasibility of controlling the bioavailability of PFAS in biosolids to timothy-grass through stabilization or mobilization approaches. Stabilization was accomplished by adding a sorbent (i.e. granular activated carbon (GAC), RemBind, biochar) to biosolids, while mobilization was achieved by adding a surfactant, sodium dodecyl sulphate (SDS), to biosolids. The results showed that the ΣPFAS concentration in grass shoots grown in biosolids amended soil treated by GAC or RemBind at 2% was only 2.77% and 3.35% of the ΣPFAS concentration detected in shoots grown in biosolids amended soil without a sorbent, respectively, indicating the effectiveness of GAC and RemBind for stabilizing PFAS and reduce their bioavailability. On the other hand, mobilization by adding SDS to biosolids at a dose range of 10–100 mg/kg significantly increased the plant uptake of ΣPFAS by 15.48%–108.57%. Thus, mobilization by adding SDS could be a valuable approach for enhancing the PFAS removal if phytoremediation is applied. Moreover, higher rate of PFAS uptake took place after grass cutting was observed in this study. Thus, proper mowing and regrowth of timothy-grass could lead to efficient and cost-effective removal of PFAS from biosolids amended soil through phytoremediation and leave the site clean to be used for other purposes.