Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Display system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

WE-D-213-00: Preparing for the ABR Diagnostic and Nuclear Medicine Physics Exams

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

WE-D-213-01: Preparing for Part 1 of the ABR Diagnostic Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

WE-D-213-02: Preparing for Part 2 of the ABR Diagnostic Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

WE-D-213-03: Preparing for Part 3 of the ABR Diagnostic Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR professional certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All three parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation and skill sets necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those aspects that are unique to the nuclear exam. Medical physicists who have recently completed each of part of the ABR exam will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to Prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to Prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

MO-F-204-00: Preparing for the ABR Diagnostic and Nuclear Medical Physics Exams

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

MO-F-204-01: Preparing for Part 1 of the ABR Diagnostic Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

MO-F-204-02: Preparing for Part 2 of the ABR Diagnostic Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

MO-F-204-03: Preparing for Part 3 of the ABR Diagnostic Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

MO-F-204-04: Preparing for Parts 2 & 3 of the ABR Nuclear Medicine Physics Exam

Adequate, efficient preparation for the ABR Diagnostic and Nuclear Medical Physics exams is key to successfully obtain ABR certification. Each part of the ABR exam presents its own challenges: Part I: Determine the scope of basic medical physics study material, efficiently review this material, and solve related written questions/problems. Part II: Understand imaging principles, modalities, and systems, including image acquisition, processing, and display. Understand the relationship between imaging techniques, image quality, patient dose and safety, and solve related written questions/problems. Part III: Gain crucial, practical, clinical medical physics experience. Effectively communicate and explain the practice, performance, and significance of all aspects of clinical medical physics. All parts of the ABR exam require specific skill sets and preparation: mastery of basic physics and imaging principles; written problem solving often involving rapid calculation; responding clearly and succinctly to oral questions about the practice, methods, and significance of clinical medical physics. This symposium focuses on the preparation necessary for each part of the ABR exam. Although there is some overlap, the nuclear exam covers a different body of knowledge than the diagnostic exam. A separate speaker will address those unique aspects of the nuclear exam, and how preparing for a second specialty differs from the first. Medical physicists who recently completed each ABR exam portion will share their experiences, insights, and preparation methods to help attendees best prepare for the challenges of each part of the ABR exam. In accordance with ABR exam security policy, no recalls or exam questions will be discussed. Learning Objectives: How to prepare for Part 1 of the ABR exam by determining the scope of basic medical physics study material and related problem solving/calculations How to prepare for Part 2 of the ABR exam by understanding diagnostic and/or nuclear imaging physics, systems, dosimetry, safety and related problem solving/calculations How to prepare for Part 3 of the ABR exam by effectively communicating the practice, methods, and significance of clinical diagnostic and/or nuclear medical physics.

60 APPLIED LIFE SCIENCES↗

A SPITZER TRANSMISSION SPECTRUM FOR THE EXOPLANET GJ 436b, EVIDENCE FOR STELLAR VARIABILITY, AND CONSTRAINTS ON DAYSIDE FLUX VARIATIONS

In this paper, we describe a uniform analysis of eight transits and eleven secondary eclipses of the extrasolar planet GJ 436b obtained in the 3.6, 4.5, and 8.0 {mu}m bands using the IRAC instrument on the Spitzer Space Telescope between UT 2007 June 29 and UT 2009 February 4. We find that the best-fit transit depths for visits in the same bandpass can vary by as much as 8% of the total (4.7{sigma} significance) from one epoch to the next. Although we cannot entirely rule out residual detector effects or a time-varying, high-altitude cloud layer in the planet's atmosphere as the cause of these variations, we consider the occultation of active regions on the star in a subset of the transit observations to be the most likely explanation. We find that for the deepest 3.6 {mu}m transit the in-transit data have a higher standard deviation than the out-of-transit data, as would be expected if the planet occulted a star spot. We also compare all published transit observations for this object and find that transits observed in the infrared typically have smaller timing offsets than those observed in visible light. In this case, the three deepest Spitzer transits are all measured within a period of five days, consistent with a single epoch of increased stellar activity. We reconcile the presence of magnetically active regions with the lack of significant visible or infrared flux variations from the star by proposing that the star's spin axis is tilted with respect to our line of sight and that the planet's orbit is therefore likely to be misaligned. In contrast to the results reported by Beaulieu et al., we find no convincing evidence for methane absorption in the planet's transmission spectrum. If we exclude the transits that we believe to be most affected by stellar activity, we find that we prefer models with enhanced CO and reduced methane, consistent with GJ 436b's dayside composition from Stevenson et al. It is also possible that all transits are significantly affected by this activity, in which case it may not be feasible to characterize the planet's transmission spectrum using broadband photometry obtained over multiple epochs. These observations serve to illustrate the challenges associated with transmission spectroscopy of planets orbiting late-type stars; we expect that other systems, such as GJ 1214, may display comparably variable transit depths. We compare the limb-darkening coefficients predicted by PHOENIX and ATLAS stellar atmosphere models and discuss the effect that these coefficients have on the measured planet-star radius ratios given GJ 436b's near-grazing transit geometry. Our measured 8 {mu}m secondary eclipse depths are consistent with a constant value, and we place a 1{sigma} upper limit of 17% on changes in the planet's dayside flux in this band. These results are consistent with predictions from general circulation models for this planet, which find that the planet's dayside flux varies by a few percent or less in the 8 {mu}m band. Averaging over the eleven visits gives us an improved estimate of 0.0452% {+-} 0.0027% for the secondary eclipse depth; we also examine residuals from the eclipse ingress and egress and place an upper limit on deviations caused by a non-uniform surface brightness for GJ 436b. We combine timing information from our observations with previously published data to produce a refined orbital ephemeris and determine that the best-fit transit and eclipse times are consistent with a constant orbital period. We find that the secondary eclipse occurs at a phase of 0.58672 {+-} 0.00017, corresponding to ecos ({omega}) = 0.13754 {+-} 0.00027, where e is the planet's orbital eccentricity and {omega} is the longitude of pericenter. We also present improved estimates for other system parameters, including the orbital inclination, a/R{sub *}, and the planet-star radius ratio.

79 ASTRONOMY AND ASTROPHYSICS↗

Low Cost Field Emission Flat Panel Displays Final Report CRADA No. TC-0774-94

The ion accelerator at LLNL enabled the fabrication of field emitter cathodes with unique physical attributes not previously avaiIabIe. These properties enabled Candescent to fabricate field emission displays in a low cost, manufacturable manner with cathode performance (efficienq and emission quality) unprecedented in the industry. Candescent and LLNL delivered to ARPA, at the end of the 15 month program, a 3" diagonal black and white display with 80 lines per inch resolution, greater than 20 footlamberts brightness, and at least 16 levels of gray. Additionally, there was a like 3" diagonal color display DOE deliverable. In comparison to liquid crystal displays, the field emission display was brighter, sharper, and consumed 1/3 to 1/2 the power per unit area. The objective of the project was to confirm the efficacy of a new technology (ion tracking) for making efficient, cost effective cathodes for flat panel displays. LLNL was to provide the ion tracking system and experfise and Candescent was to provide the requirements, complete the fabrication of the cathodes, and incorporate them in flat panel displays. The program was quite successful. Candescent is now on the verge of commercializing 5.3 inch diagonal full color flat panel displays using this technology.

42 ENGINEERING↗

Contact resistance and overlapping capacitance in flexible sub-micron long oxide thin-film transistors for above 100 MHz operation

In recent years new forms of electronic devices such as electronic papers, flexible displays, epidermal sensors, and smart textiles have become reality. Thin-film transistors (TFTs) are the basic blocks of the circuits used in such devices and need to operate above 100 MHz to efficiently treat signals in RF systems and address pixels in high resolution displays. Beyond the choice of the semiconductor, i.e., silicon, graphene, organics, or amorphous oxides, the junctionless nature of TFTs and its geometry imply some limitations which become evident and important in devices with scaled channel length. Furthermore, the mechanical instability of flexible substrates limits the feature size of flexible TFTs. Contact resistance and overlapping capacitance are two parasitic effects which limit the transit frequency of transistors. They are often considered independent, while a deeper analysis of TFTs geometry imposes to handle them together; in fact, they both depend on the overlapping length (L{sub OV}) between source/drain and the gate contacts. Here, we conduct a quantitative analysis based on a large number of flexible ultra-scaled IGZO TFTs. Devices with three different values of overlap length and channel length down to 0.5 μm are fabricated to experimentally investigate the scaling behavior of the transit frequency. Contact resistance and overlapping capacitance depend in opposite ways on L{sub OV}. These findings establish routes for the optimization of the dimension of source/drain contact pads and suggest design guidelines to achieve megahertz operation in flexible IGZO TFTs and circuits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Plasmon hybridization in parallel nano-wire systems

We apply the plasmon hybridization method to a double-nano-wire system, providing a simple and intuitive description of the plasmon excitations in the system. We apply the two-center cylindrical coordinate system for mathematical convenience and find an explicit form of the surface plasmon oscillations, in terms of the interaction between the bare plasmon modes of the individual surfaces of the nano-wires. We present numerical results to display how the plasmon excitations of the system depend on nano-wire separation when there is no angular momentum transfer, i.e., when m = 0.

36 MATERIALS SCIENCE↗

Study on the formation of Co{sub x}Fe{sub 3−x}O{sub 4} system using two low temperature synthesis methods

Graphical abstract: Display Omitted Highlights: ► Co{sub x}Fe{sub 3−x}O{sub 4} nanopowders are synthesized by two synthesis methods. ► The thermal decomposition of mixed Fe(III), Co(II) carboxylates method is original. ► For x = 1.0, CoFe{sub 2}O{sub 4} crystallizes as single phase at low temperatures by both methods. ► The presence of secondary phases for x ≠ 1 influences the magnetic properties. ► The particles are nanosized (<50 nm) leading to sintering at lower temperatures. -- Abstract: This paper presents a study regarding the cobalt ferrite obtaining in the Co{sub x}Fe{sub 3−x}O{sub 4} system, where x = 0.5; 1.0; 1.5 by two different synthesis methods. The Co(II) and Fe(III) complexes method leads to the thermal decomposition at 300 °C for this precursor with the pure cobalt ferrite (CoFe{sub 2}O{sub 4}) formation for x = 1 or mixed with γ-Fe{sub 2}O{sub 3} for x = 0.5 and Co{sub 3}O{sub 4} for x = 1.5. By co-precipitation followed by ultrasonic milling synthesis method the pure cobalt ferrite is obtained at 90 °C for x = 1 or mixed with Fe{sub 3}O{sub 4} for x = 0.5 and Co{sub 3}O{sub 4} for x = 1.5. When the initial samples are heated at 400 °C, the identified oxide phase is identical for the same value of x. The obtained powders were investigated by X-ray diffraction (XRD), FTIR spectrometry and scanning electron microscopy (SEM) with energy dispersive spectroscopy (EDX). The final product has nanometric size and has a strong tendency to agglomerated, thus influencing the saturation magnetization value. The shape of the magnetization curves is influenced by the presence of the secondary phases for x ≠ 1.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-cusp ion source for doping process of flat panel display manufacturing

We developed a multi-cusp ion source for Nissin ion doping system iG5 which is used in low temperature poly-crystalline silicon processes for flat panel display (FPD) manufacturing. In this ion source, BF{sub 3} or PH{sub 3} diluted H{sub 2} plasmas are produced and large area ribbon ion beams are extracted. In general, ion ratio of B{sup +} in BF{sub 3} plasma is much smaller than BF{sub 2}{sup +} in multi-cusp ion sources. We developed a new method to increase B{sup +} ratio and obtained mass analyzed B{sup +} target current of 130 mA. We employed newly improved multi-slot type electrodes for the beam extraction system and obtained stable beams with the uniformity of below 3%. In BF{sub 3} plasmas, several undesirable metal fluorides are produced in the plasma chamber and deposited on the electrode system, which cause glitches and poor beam uniformity. We introduce several cleaning methods.

36 MATERIALS SCIENCE↗

Porous Nanomaterials for Ultrabroadband Omnidirectional Anti‐Reflection Surfaces with Applications in High Concentration Photovoltaics

Materials for nanoporous coatings that exploit optimized chemistries and self‐assembly processes offer capabilities to reach ≈98% transmission efficiency and negligible scattering losses over the broad wavelength range of the solar spectrum from 350 nm to 1.5 µm, on both flat and curved glass substrates. These nanomaterial anti‐reflection coatings also offer wide acceptance angles, up to ±40°, for both s‐ and p‐polarization states of incident light. Carefully controlled bilayer films have allowed for the fabrication of dual‐sided, gradient index profiles on plano‐convex lens elements. In concentration photovoltaics platforms, the resultant enhancements in the photovoltaics efficiencies are ≈8%, as defined by experimental measurements on systems that use microscale triple‐junction solar cells. These materials and their applications in technologies that require control over interface reflections have the potential for broad utility in imaging systems, photolithography, light‐emitting diodes, and display technologies.

Yao, Yuan↗

A Model Study of Substrate Effect on the Neutron-Scattering Spectra of Ferromagnetic Ordered Graphene

Graphene as a possible new magnetic material has stimulated research interest for application in spintronic devices. Pristine graphene does not show magnetism due to equivalence of the two sub-lattices of carbon atoms. It is predicted that impurity effects, substrate-induced gap, and defects, are expected to produce in-equivalence in two carbon sub-lattices leading to magnetism. The spins on the same sub-lattices are found to exhibit ferromagnetic order and spins of different sub-lattices are found to exhibit anti-ferromagnetic order. We consider here impurity and substrate effects as the cause of generation of magnetism in graphene. We report here a microscopic tight-binding study of frequency-dependent neutron scattering spectra for ferromagnetic ordering in the graphene systems. The tight-binding Hamiltonian consists of electron hoppings upto third nearest neighbors and substrate and impurity effects in the presence of Coulomb interaction of electrons separately at two in-equivalent A and B sub-lattices of graphene. We calculate the two-particle electron Green’s functions by using Zubarev’s Green’s function technique. The frequency-dependent scattering intensity of the system is computed numerically. The spectra displays a sharp peak at the neutron momentum transfer energy at low energies and another higher-energy peak appearing at substrate-induced gap.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Broadband coherent perfect absorber with PT-symmetric 2D-materials

We suggest graphene and a two-dimensional (2D) Weyl semimetal (WSM) as 2D materials for the realization of a broadband coherent perfect absorber (CPA) respecting overall PT-symmetry. We also demonstrate the conditions for mutually equal amplitudes and phases of the left and right incoming waves to realize a CPA. 2D materials in our system play the role to enhance the absorption rate of a CPA once the appropriate parameters are inserted in the system. We show that a 2D WSM is more effective than graphene in obtaining the optimal conditions. We display the behavior of each parameter governing the optical system and show that optimal conditions of these parameters give rise to enhancement and possible experimental realization of a broadband CPA-laser.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗