Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct Air Capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Improvement of Alstom's Limestone-Based Chemical Looping Combustion Process for Higher Purity Flue Gas Production

Alstom Power Inc., a wholly owned subsidiary of the General Electric Company (GE), is developing Limestone-based Chemical Looping (LCL™) Processes, utilizing limestone derived calcium sulfate as an oxygen carrier to transport oxygen from air to the fuel. The LCL™ process is a breakthrough technology with the potential to capture CO 2 and SO 2 from new and existing coal-fired power plants at reduced costs while maintaining high plant power generation efficiency. Chemical looping is a next generation advancement to oxy-combustion which would not require the significant investment in a cryogenic distillation type oxygen production plant. Instead of the energy-consuming oxygen plant, chemical looping uses a benign material to directly remove oxygen from the air and bring that oxygen into contact with the fuel. This "game changing" technology is the lowest cost-of-electricity technical approach that GE Power has identified to date for coal power with carbon capture. The technology has significantly lower capital costs compared to a conventional steam power plant with first generation carbon capture technologies. This new power plant concept is based on a hybrid combustion-gasification process utilizing high temperature chemical and thermal looping technology. In the air reactor, a solid oxygen carrier picks up oxygen from air through an oxidation reaction and leaves nitrogen behind. The hot oxygen-carrying solid carrier is then transported to a fuel reactor, where it releases oxygen. The released oxygen then converts the coal in the fuel reactor into combustion gases. The solid carrier is recycled back to the air reactor for regeneration completing the “chemical loop.” The regeneration step produces heat from which steam is produced for power generation while the process results in a concentrated carbon dioxide stream in which the carbon is captured for use or sequestration (CCUS). Limestone as a precursor for the oxygen carrier is abundant, benign, low cost, and is used in CFB and PC boilers for sulfur control. Challenges associated with this carrier include a complex reaction mechanism with possible side reactions leading to the release of SO 2 . The present project (DOE/NETL Cooperative Agreement No. DE-FE0025073) report focuses on coal-fired Limestone Chemical Looping Combustion (LCL-C™) processes that can produce a higher purity flue gas stream and achieve an improved overall performance that will meet the stated DOE goal of generating power from coal while achieving greater than 90% CO2 removal at less than 35% increase in the Levelized Cost of Electricity (LCOE). It builds on the concurrent and synergistic limestone-based chemical looping combustion (LCL-C™) and gasification (LCL-G™) projects with the Department of Energy, that were executed in parallel with the present project. In this report, the LCL-C™ experimental testing from the electrically-heated, once-through, 100 kW Pilot-Scale Test Facility (PSTF) is analysed and reviewed. The PSTF Oxidizer is a 50-foot tall, 100-mm diameter transport reactor, while the PSTF Reducer reactor is based upon a bubbling-bed design. The experimental data from designated test periods (denoted “Weeks”) are reviewed and discussed. The application of high sulfur release in the Reducer (with proper sulfur management) exceeded the LCL-CTM performance targets. Furthermore, the ilmenite blend came within 1 percentage point of meeting all of the performance targets.

01 COAL, LIGNITE, AND PEAT↗

Oxygen-Fired CO 2 Recycle for Application to Direct CO 2 Capture form Coal-Fired Power Plants

The Southern Research/Southern Company 1 MWth Pilot-Scale Coal-Fired Test Facility was successfully retrofit to fire in either the traditional air-fired mode or with 100% oxygen and recycled flue gas, with a fully integrated feedback and control system, including oxygen and recycled flue gas modulation during startup, transfer, and shutdown, safety and operational interlocks, and data acquisition. A MAXON Staged Oxygen Burner for Oxy-Coal Applications produced a stable flame over a significant range of firing turn-down, staging, and while firing five different U.S. coal types. The MAXON burner design produces lower flame temperatures than for air firing, which will enable (A) Safe operation, (B) Reduction of recycle flow without concern about furnace flame temperatures, and (C) May likely be affective at reducing slagging and fouling in the boiler and super heater at full-scale Power Plants. A CFD model of the Oxy-fired Combustion Research Facility (OCRF) was used to predict the flame geometry and temperatures in the OCRF and make a comparison with the air-fired case. The model predictions were consistent with the experimental data in showing that the MAXON burner fired with oxygen produced lower flame temperatures than the air-fired burner while firing with air.

01 COAL, LIGNITE, AND PEAT↗

Effective direct steam regeneration of bis-iminoguanidine solid sorbent used for carbon dioxide capture

A cost-effective, energy-efficient sorbent regeneration process for phase-changing guanidines used for CO 2 capture was developed based on direct-steam stripping. This approach enhances the regeneration rate, simplifies the overall CO 2 capture process, and reduces the energy cost compared to conventional conductive thermal regeneration. A direct-steam sorbent regeneration reactor was developed, demonstrating that aqueous bis(iminoguanidines) (BIG) sorbents, e.g., methylglyoxal-bis(iminoguanidine) (MGBIG) and glyoxal-bis(iminoguanidine) (GBIG), could be efficiently regenerated with up to ~ 99 % CO 2 recovery through direct-steam stripping. Using low-temperature steam at 100 °C, a 4.5 times faster regeneration rate for GBIG carbonate sorbent (e.g., 30 min for 10 g) was demonstrated compared to conductive-heating (e.g., 135 min for 10 g) at 130 °C. Additionally, fully regenerated MGBIG converts into an aqueous MGBIG solution when the steam condenses onto the sorbent surface. Condensed steam with the guanidine can be easily recycled as an aqueous solution into the gas–liquid contactor to achieve a continuous-flow CO 2 -capture process. Molecular dynamics simulation was employed to provide a better understanding of the process. Higher heat transfer rates from steam to guanidine carbonate, compared to air heating, were attributed to the vibration resonance of water molecules within MGBIG with that of vapor molecules and the effective transfer of kinetic energy from vapor to solid. Technoeconomic analysis demonstrated that direct-steam stripping significantly decreases the CO 2 capture cost by 50 % compared to traditional conductive heating methods. Further, enhanced mass transfer facilitated by low-temperature steam and subsequent condensation effectively heats up the H 2 O-containing BIG-carbonate crystals, facilitating the desorption of CO 2 from the solid crystals, thereby leading to fast, effective, and energy-efficient sorbent regeneration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sodar Data from Oyster Bay at Winyah Bay National Estuarine Research Reserve in South Carolina

The SecondWind Triton® is a SODAR (SOnic Detection and Ranging) sonic wind profiler (Triton® sodar) system capable of profiling the wind characteristics up to 200m above the instrument. SODAR systems transmit acoustic chirps into the atmosphere and measure the backscattered signal returned to the device. The primary source of acoustic scattering is variations in air temperature, which cause changes in the refractive index of sound. By measuring the Doppler-shifted frequency of these returned signals, the Triton® can calculate the wind’s speed and direction for the volume of air above the instrument, measured at ten fixed heights, known as station heights. The Triton® is specifically designed for the purpose of wind energy resource assessment as it can remotely capture wind data at heights above ground where wind turbine rotors operate. The measurements made include horizontal wind speed and direction, vertical wind speed, and turbulence. Other integrated sensors provide time and location via GPS, barometric pressure, humidity, and the tilt of the instrument. The study area is located east of Georgetown, South Carolina in North Inlet - Winyah Bay National Estuarine Research Reserve. The monitoring period for data in this report begins 5/14/2009 9:30:00 AM EST and ends 8/2/2010 11:40:00 AM EST.

17 WIND ENERGY↗

Summary Report of the Reactive CO 2 Capture: Process Integration for the New Carbon Economy Workshop

Decarbonization of our global economy is required to limit planetary warming to +1.5⁰C above pre-industrial levels, an ambitious goal set into motion by the Paris agreement. Given the scale and urgency, the solution demands international, cross-sector advancements spanning policy, social responsibility, and technology, with emphasis on step changes over incremental changes. To that end, technological revolutions that disrupt the status quo need to be envisioned and enacted. One potential technological revolution is the production of fuels, chemicals, and materials from carbon dioxide (CO 2 ) as the starting feedstock, leveraging renewable energy as the driving force. Over the past decades, significant research, development, and deployment has occurred on technologies for capturing CO 2 from point sources or the air and utilizing this CO 2 as a working fluid or as a chemical reactant; however, most of this work has been siloed in these two categories. Recently, an emerging field has started to explore the direct integration of CO 2 capture and conversion technologies as a means to reduce overall energy demand (i.e., avoid energy penalty of CO 2 desorption/regeneration of capture media) and capital expense through process intensification. This strategy represents an opportunity to leapfrog forward this technological revolution. However, the field is in its infancy and the technologies are at an early stage of development, thus it is critically important to define and assess the value proposition of this strategy relative to alternatives (e.g., separated capture and conversion technologies, fuels and chemicals derived from renewable feedstocks like biomass, and industrial electrification) to chart a path forward. To identify next steps, we organized a workshop titled “Reactive CO 2 Capture: Process Integration for the New Carbon Economy” which was held in Golden, Colorado, February 18–19, 2020. The focus of this workshop was to discuss approaches for merging CO 2 capture and CO 2 conversion/utilization systems into what we denoted as an integrated "reactive capture" strategy. By our definition, reactive capture of CO 2 is the coupled process of capturing CO 2 from a mixed gas stream and converting it into a valuable product without going through a purified CO 2 intermediate (see full definition in the Introduction section). This report seeks to summarize feedback from the approximately 125 participants and subject matter experts in attendance from academia, industry, U.S. Department of Energy (DOE), and DOE national laboratories. The workshop agenda is included in Appendix A and the full list of attendees can be found in Appendix B. To elucidate a path forward, we first asked the attendees to define what success would look like for reactive capture in the short term (0–5 years), midterm (5–10 years), and long term (10+ years) and then asked them to answer four questions related to how we could achieve that success: (1) What are the key barriers and challenges to success? (2) What are needed activities to overcome barriers and challenges? (3) What opportunities will arise from these activities? (4) What is a target outcome and what metrics need to be met?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving Flexibility and Performance of Staged Pressurized Oxy-Combustion

Staged pressurized oxy-combustion (SPOC) is a novel coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Oxy-combustion plants operate by removing most of the nitrogen contained in air prior to combustion, thereby burning fuel in a near-pure oxygen stream instead of air. This combustion produces a flue gas containing primarily carbon dioxide (CO 2 ) and water vapor that allows relatively straightforward CO 2 capture. First-generation, atmospheric oxy-combustion technology relies on a flue gas recycle (FGR) diluent to reduce the peak temperatures achieved and the resulting high thermal radiation levels that would otherwise occur in a fuel/oxygen only flame. In contrast, by staging the combustion in several steps, SPOC reduces the peak temperatures of combustion without resorting to a high degree of FGR to control flame temperatures. The SPOC process operates by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given combustion module. Subsequently the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. While the staging controls the heat release profile in SPOC, operating in a pressurized condition yields a more compact system, reducing modular boiler size and delivering enhanced heat transfer. Additionally, operating at elevated pressures ensures that the latent heat of moisture available from moisture in the fuel and generated by the combustion of the hydrogen content in the fuel can be captured as useful thermal energy for steam turbine integration. This is possible due to elevated dew point from the high partial pressure of the moisture generated in this process, which allows substantial feedwater heater bypassing to be achieved. The inclusion of this thermal energy, normally lost to the atmosphere in traditional combustion processes or to cooling systems in atmospheric oxy-combustion, allows the resultant net efficiency of the SPOC system to be up to 6 percentage points greater than first-generation systems. To begin the process of developing this technology for full-scale application, the Electric Power Research Institute, Inc. teamed up with WUSTL, American Air Liquide, Doosan Babcock, and the U.S. Department of Energy to investigate a practical and workable boiler design concept that would minimize process risks where possible. The SPOC system offers unique process flexibility opportunities due to the staged nature of the combustion, making it a prime candidate for future primary energy delivery where the ability to operate at reduced load in an efficient manner and ramp rapidly will be valuable for balancing intermittent renewable electricity generation. The efficiency of traditional coal-fired power plants is lower at reduced loads below the steam temperature control range due to the challenges in balancing the heat pickup between radiative and convective superheater and reheater surface. Introducing additional heating surface for optimal extended controlled low load operation will likely lead to excessive attemperation at high loads, ultimately leading to a poorer overall cycle efficiency. The SPOC process can facilitate the adjustment of fuel firing rates between stages, targeting heat pickup to where it is most needed and potentially can shut down stages for low-load operation, facilitating an increased steam temperature control range on turndown. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the potential resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Parameters being investigated include flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. These are being carried out for a range of inlet gas conditions and compositions and at multiple load conditions to investigate combustion stability at reduced load. The results of this testing inform the modeling of the large-scale system, that was sized at 550 MWe to allow direct comparison with the National Energy Technology Laboratory baseline cases for atmospheric oxy-combustion, air firing, and air firing with post-combustion capture.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical Simulation Comparison of Two Reactor Configurations for Chemical Looping Combustion and Chemical Looping With Oxygen Uncoupling

Chemical looping with oxygen uncoupling (CLOU) is a carbon capture technology that utilizes a metal oxide as an oxygen carrier to selectively separate oxygen from air and release gaseous O 2 into a reactor where fuel, such as coal, is combusted. Previous research has addressed reactor design for CLOU systems, but little direct comparison between different reactor designs has been performed. This study utilizes Barracuda-VR® for comparison of two system configurations, one uses circulating fluidized beds (CFB) for both the air reactor (AR) and fuel reactor (FR) and another uses bubbling fluidized beds for both reactors. Initial validation of experimental and computational fluid dynamic (CFD) simulations was performed to show that basic trends are captured with the CFD code. The CFD simulations were then used to perform comparison of key performance parameters such as solids circulation rate and reactor residence time, pressure profiles in the reactors and loopseals, and particle velocities in different locations of the reactor as functions of total solids inventory and reactor gas flows. Here, using these simulation results, it was determined that the dual CFB system had larger range for solids circulation rate before choked flow was obtained. Both systems had similar particle velocities for the bottom 80% of particle mass, but the bubbling bed (BB) obtained higher particle velocities as compared to the circulating fluidized-bed FR, due to the transport riser. As a system, the results showed that the dual CFB configuration allowed better control over the range of parameters tested.

30 DIRECT ENERGY CONVERSION↗

Investigating ultrafine aerosol turbulent fluxes during atmospheric new particle formation events

New particle formation (NPF) is an important source of atmospheric aerosols, yet quantitatively predicting its occurrence remains challenging, partly because ground-based measurements cannot capture NPF accurately if they occur in the upper atmosphere. While observations have confirmed the presence of new particles near the top of the planetary boundary layer (PBL), their origins and the direction of their vertical transport have remained ambiguous. Here, we propose and validate an analytical framework using airborne eddy-covariance (EC) and continuous wavelet transform (CWT) to directly quantify the vertical flux of newly formed particles and determine its dominant vertical transportation direction. Analyzing data from a dedicated airborne campaign over the Southern Great Plains, we observed a persistent and strong downward particle flux during NPF events, with a mean value of 133.8 cm?3 m s?¹ downward flux in the entrainment zone, whereas fluxes on non-NPF days were negligible. Our spectral analysis further confirms that these directional fluxes can be reliably captured using standard 1 Hz aerosol instrumentation. These findings suggest that new particle formation, driven by the entrainment of air from the overlying residual/stable layer during PBL growth, is a significant and potentially understudied source of boundary layer aerosols. The framework presented here provides a methodology to correctly attribute NPF events to specific altitudes, thereby improving the mechanistic understanding required for accurate atmospheric models.

Zhang, Ruoyu↗

Noria: A Highly Xe‐Selective Nanoporous Organic Solid

Abstract Separation of xenon and krypton is of industrial and environmental concern; the existing technologies use cryogenic distillation. Thus, a cost‐effective, alternative technology for the separation of Xe and Kr and their capture from air is of significant importance. Herein, we report the selective Xe uptake in a crystalline porous organic oligomeric molecule, noria, and its structural analogue, PgC‐noria, under ambient conditions. The selectivity of noria towards Xe arises from its tailored pore size and small cavities, which allows a directed non‐bonding interaction of Xe atoms with a large number of carbon atoms of the noria molecular wheel in a confined space.

Patil, Rahul S.↗

Opposed Jet Burner Approach for Characterizing Flameholding Potentials of Hydrocarbon Scramjet Fuels

Opposed Jet Burner (OJB) tools have been used extensively by the authors to measure Flame Strength (FS) extinction limits of laminar H2/N2 air and (recently) hydrocarbon (HC) air Counterflow Diffusion Flames (CFDFs) at one atm. This paper details normalization of FSs of N2- diluted H2 and HC systems to account for effects of fuel composition, temperature, pressure, jet diameter, inflow Reynolds number, and inflow velocity profile (plug, contoured nozzle; and parabolic, straight tube). Normalized results exemplify a sensitive accurate means of validating, globally, reduced chemical kinetic models at approx. 1 atm and the relatively low temperatures approximating the loss of non-premixed idealized flameholding, e.g., in scramjet combustors. Laminar FS is defined locally as maximum air input velocity, U(sub air), that sustains combustion of a counter-jet of g-fuel at extinction. It uniquely characterizes a fuel. And global axial strain rate at extinction (U(sub air) normalized by nozzle or tube diameter, D(sub n or (sub t)) can be compared directly with computed extinction limits, determined using either a 1-D Navier Stokes stream-function solution, using detailed transport and finite rate chemistry, or (better yet) a detailed 2-D Navier Stokes numerical simulation. The experimental results define an idealized flameholding reactivity scale that shows wide ranging (50 x) normalized FS s for various vaporized-liquid and gaseous HCs, including, in ascending order: JP-10, methane, JP-7, n-heptane, n-butane, propane, ethane, and ethylene. Results from H2 air produce a unique and exceptionally strong flame that agree within approx. 1% of a recent 2-D numerically simulated FS for a 3 mm tube-OJB. Thus we suggest that experimental FS s and/or FS ratios, for various neat and blended HCs w/ and w/o additives, offer accurate global tests of chemical kinetic models at the Ts and Ps of extinction. In conclusion, we argue the FS approach is more direct and fundamental, for assessing, e.g., idealized scramjet flameholding potentials, than measurements of laminar burning velocity or blowout in a Perfectly Stirred Reactor, because the latter characterize premixed combustion in the absence of aerodynamic strain. And FS directly measures a chemical kinetic characteristic of non-premixed combustion at typical flameholding temperatures. It mimics conditions where gfuels are typically injected into a subsonic flameholding recirculation zone that captures air, where the effects of aerodynamic strain and associated multi-component diffusion become important.

Pellett, Gerald L.↗

Interconnected nanoconfining pore networks enhance catalyst CO 2 interaction in electrified reactive capture

Systems that sequentially capture and upgrade CO 2 from air to fuels/fuel-intermediates, such as syngas and ethylene, rely on an energy-intensive CO 2 release process. Electrified reactive capture systems transform CO 2 obtained directly from carbonate capture liquid into products. Previous reactive capture systems show a decline in Faradaic efficiencies (FE) at current densities above 200 mA/cm 2 . Here we show the chemical origins of this problem, finding that prior electrocatalyst designs failed to arrest, activate, and reduce in situ-generated CO 2 (i-CO 2 ) before it traversed the catalyst layer and entered the tailgas stream. We develop a templated synthesis to define pore structures and the sites of Ni single atoms, and find that carbon-nitrogen-based nanopores are effective in accumulating i-CO 2 via short-range, non-electrostatic interactions between CO 2 molecules and the nanochannel walls. These interactions confine and enrich i-CO 2 within the pores, enhancing its binding and activation. We report as a result carbonate electrolysis at 300 mA/cm 2 with FE to CO of 50% ± 3%, and with <1% CO 2 in the tailgas outlet stream. This corresponds to a projected energy efficiency (EE) to 2:1 syngas of 46% at 300 mA/cm 2 when H 2 is added using a water electrolyzer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wireless Solar Water Splitting Using Silicon-Based Semiconductors and Earth-Abundant Catalysts

We describe the development of solar water-splitting cells comprising earth-abundant elements that operate in near-neutral pH conditions, both with and without connecting wires. The cells consist of a triple junction, amorphous silicon photovoltaic interfaced to hydrogen- and oxygen-evolving catalysts made from an alloy of earth-abundant metals and a cobalt|borate catalyst, respectively. The devices described here carry out the solar-driven water-splitting reaction at efficiencies of 4.7% for a wired configuration and 2.5% for a wireless configuration when illuminated with 1 sun (100 milliwatts per square centimeter) of air mass 1.5 simulated sunlight. Fuel-forming catalysts interfaced with light-harvesting semiconductors afford a pathway to direct solar-to-fuels conversion that captures many of the basic functional elements of a leaf.

Reece, SY↗

Biobriefcase aerosol collector heater

A system for sampling air and collecting particles potentially including bioagents entrained in the air for detection. The system comprises collecting a sample of the air with the particles entrained in the air, directing the sample to a receiving surface, directing a liquid to the receiving surface thereby producing a liquid surface, wherein the particles potentially including bioagents become captured in the liquid, and heating the liquid wherein the particles potentially including bioagents become heated to lysis the bioagents.

47 OTHER INSTRUMENTATION↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Performance and Cost Potential for Direct-Fired Supercritical CO2 Natural Gas Power Plants

Direct-fired supercritical CO2 (sCO2) power cycles are being explored as an attractive alternative to natural gas combined cycle (NGCC) plants with carbon capture and storage (CCS). Therefore, understanding their performance and cost potential is important for the commercialization of the technology. This study presents the techno-economic optimization results of natural gas-fired, utility-scale power plants based on the direct sCO2 power cycle, which are lacking in public literature. To identify the optimum plant configuration, the study considered multiple cases with varying levels of thermal integration with the plant air separation unit (ASU). Several design variables for each power cycle configuration were identified and optimized to minimize the levelized cost of electricity (LCOE) for each case. The optimization design variables include the sCO2 cooler outlet temperatures, recuperator approach temperatures, and pressure drops. High fidelity models for recuperators, coolers, and turbines were developed and used to capture the impact of design variables on plant efficiency and capital costs. The optimization was conducted using a combination of manual sensitivity analyses and automated derivative-free optimization algorithms available under NETL’s Framework for Optimization and Quantification of Uncertainty and Sensitivity platform. The optimized direct sCO2 power plants offered similar or slightly higher plant efficiencies than the reference NGCC plants based on the F-class gas turbine with CCS. The LCOE of the optimized direct sCO2 plants is 13 to 17% higher than the reference NGCC plants with CCS due to high capital costs associated with the ASU and sCO2 power block, though there is significant room for improvement due to the high uncertainty in component capital costs for these new plants. Recuperators make up over 50% of the sCO2 power block costs. Consequently, any research and development efforts to reduce the recuperator capital costs will benefit the technology’s commercialization. The study also presents preliminary results showing the impact of co-firing landfill gas and natural gas on plant efficiency, LCOE, and CO2 emissions.

Pidaparti, Sandeep↗

Numerical Analysis of Water Harvesting from Saturated Vapor with the Electrospray Water Droplet Injection in The Solar-Driven Desalination Applications

Solar-driven seawater desalination systems provide freshwater through environmentally friendly and carbon-neutral processes. Air humidification and dehumidification desalination (HDD) systems extract water directly from moist air. This paper focuses on a new solar-driven seawater desalination system that shares some common traits with HDD systems but in which the air is eliminated from the process. Seawater is vaporized by solar thermal radiation in high-performance solar panels. Water vapor flows to a new electro-condensation chamber and passes through a series of electrosprays, which inject small nuclei of freshwater droplets into the vapor clouds. Here, due to dielectrophoresis and electrohydrodynamic flows, the vapor molecules are captured by the charged droplets, and vapor is condensed at the droplet surface. The water vapor condensation was modeled by using the multiphase flow numerical model. The CFD model, which was also experimentally validated, used SprayFoam solver modules available in the Open FOAM® CFD open-source software. In preliminary results, 802 grams/(hr-m2) (grams per hour per unit area) of water was harvested directly from moist air at 24C and 90% relative humidity. The simulation results indicated that freshwater productivity could increase up to 4,000 grams/(hr-m2) for fully saturated air conditions. This represents about 5 times the water productivity rate of current conventional HDD systems today. In addition, energy consumption could be reduced by 80 percent compared to conventional HDD systems.

Electrospray, electro-condensation, solar, droplet↗

Commercial Building Technology Demonstration (Final Scientific/Technical Report)

The background for this project was a unique and innovative concept that had been proposed and demonstrated by enVerid Systems, reducing the energy consumption in HVAC systems in commercial and public buildings by up to 50% at peak loads. The concept involves selective scrubbing of gas contaminants from indoor air as a practical substitute for outside air ventilation, the latter being the conventional practice today. This scrubbing enables recycling of most of the indoor air and significantly decreasing the amount of outside air, resulting in a reduced HVAC load and commensurate energy savings for the facility. Key to our approach is low cost scrubbing of all gas contaminants from indoor air using novel, efficient and regenerable sorbent materials. The total solution, labeled HLR (HVAC Load Reduction) is implemented by means of compact modules that can be retrofitted onto virtually any building, and utilizes novel sorbents that have been developed and brought to scale production by enVerid. Although the technology had been deployed and demonstrated, the US commercial building and HVAC markets, famously conservative with respect to innovation and new technologies, had yet to embrace the idea or the product. The overarching goal of the project was to help overcome market hesitancy and enable widespread adoption, by creating a critical mass of success stories across different regions and building types, all under oversight and verification of the DOE and NREL, to ensure credibility and accuracy. The project, overall, was a resounding success. Several installations were deployed and tested comprehensively for the impact on both energy consumption and indoor air quality, and results were not only excellent, but quantitatively in line with expectations. A total number of eight (8) installations were attempted, with 2 aborted due to building issues. Of the six successful installations, however, complete M&V was performed by NREL on 2 (Miami and NYC) and partial analysis on a third site (ArcBest), and these three, along with their results, were therefore presented from a financial and reporting standpoint. Although the number of case studies fell short of the original target of 10, we nevertheless had excellent demonstrations in vastly different climate zones: Southeast, Northeast and Midwest, and in very different building types. This included a modern high-rise office building in New York City and a University Campus health center in Miami, and a mid-rise high-density office in Arkansas. The cooling load reduction was shown to be significant, averaging 37% during the final cooling season in the Miami site. In the NYC site, the cooling energy savings were generally less, at around 12%, as expected. While this is a lower number for average/total savings, two comments are important to note: (i) the outside airflow (OA) reduction was not consistent during the data collection period, at least in part understating the attainable savings through incorrect measurement of the “high energy” reference state; and (ii) the peak impact in NYC is almost certainly as high as Miami, with critical ramifications for peak load reduction and equipment downsizing ability. Importantly, the measured energy savings in all locations were related to the outdoor climate conditions and the actual achievable reduction in outside air, very much in line with models and calculations; this leaves us with increased confidence in our understanding of the interaction between the technology and the building, and our ability to project the impact of this innovation in the future, through broad adoption. Simply put: the energy savings and load reduction impact of the HLR solution has been confirmed quantitatively. The results also confirmed the air quality objective. This may be even more significant, in that air quality is more complex and harder to measure and quantify, and the performance of the HLR as an air scrubber is the linchpin of the entire solution. In all sites, indoor air quality met or exceeded the required parameters, in terms of achieving the target (low) levels of indoor pollutants. Furthermore, the concentrations of outdoor sourced pollutants were markedly lower, as expected, mostly due to the reduction in outside air intake although in part also due to the scrubbing. The success was not immediate nor easy, and early challenges with the systems, especially (but not only) around controls and communication, caused delays in commissioning and undermined some of our M&V schedules. The good news is no fundamental issues were encountered and the number of such glitches was declining quickly by the end of the project. Other challenges had to do with coordinating the control of the building OA dampers, which the HLR needs to have in order to deliver the load reduction, but which the facility manager controls regularly and independently. This is not necessarily a problem for normal HLR operation but interferes with accurate M&V, where switching OA settings back and forth on a precise timetable is essential for clean data. The project provided valuable experience in retrofitting buildings that had been originally designed to operate with less recirculation and more outside air, and some key learnings related to the cyclical regeneration of the sorbents in the operational environment of the building. Some of these learnings gave already been incorporated into ongoing improvements in the design of the HLR module as well as the software that is used to control its operation. The cost and time of retrofit installations is much better understood; so is the test and balance procedure of the building that determines the available range of outside air reduction, which in turn determines the amount of load reduced. We had also implemented at least one annual cycle of sorbent cartridge replacement in the field, after which we tested the used sorbent to assess the rate of degradation of sorbent potency – an important factor affecting the long-term economics of HLR deployments. A notable shortfall of the project, other than the fact that the number of sites was below target, was that we had not (yet) completed testing to measure and verify (M&V) the winter energy savings. This is primarily due to late start on the NYC sites (Miami does not portend any heating savings associated with reduced outside air), combined with the issues of OA damper control. It is by no means suggested that such savings cannot be captured, only that the M&V with respect to winter in NYC has been incomplete. The value of this project and its interest to the general public are hard to overstate. The case studies created from Miami and especially from NYC have, without a doubt, opened up the interest of the broad HVAC industry to HLR in the past year. Major manufacturer reps have signed up to represent and promote the product, and dozens of top tier engineering consultants have introduced HLR as a base of design in upcoming construction and renovation projects – precisely the overarching goal of this project. These would not have happened without the highly visible installation in NYC and its ultimately satisfied customer. Furthermore, the DOE itself issued a report in late 2017 analyzing hundreds of candidate technologies for reducing energy consumption in HVAC; remarkably, the budding HLR solution ranked among the top 3(!); no doubt, its status as a viable and significant contender on this list is informed by the success of these demonstrations. And furthermore, in the wake of these demos, several major energy utilities, led by ConEdison in NYC, have endorsed the HLR solution and now routinely provide substantial cash rebates for customers choosing to incorporate the HLR in their buildings and reap the benefit of the reduced peak load as well as reduced cumulative energy demand. Last but not least, in January of 2019, as this report was being written, the HLR module won the AHR Expo Innovation Award for Green Buildings and, remarkably, the prestigious and only Product of the Year 2019, being selected by an independent professional panel of judges from AHR and ASHRAE. Given the confirmation of the enormous energy saving potential of HLR in widescale deployment, as well as ancillary but significant benefits in terms of equipment downsizing and indoor air quality, the benefit of this effort to the public speaks for itself. Accelerating adoption of HLR, without dependence on subsidies and driven by the private sector, is well under way. There is still much work to be done in terms of educating the HVAC and construction ecosystems and improving the product’s robustness and simplicity, to further facilitate the adoption of this technology and the capture of its potential value. But the American public will greatly benefit both directly and indirectly in the immediate future and beyond.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A model of the tropical Pacific sea surface temperature climatology

A model for the climatological mean sea surface temperature (SST) of the tropical Pacific Ocean is developed. The upper ocean response is computed using a time dependent, linear, reduced gravity model, with the addition of a constant depth frictional surface layer. The full three-dimensional temperature equation and a surface heat flux parameterization that requires specification of only wind speed and total cloud cover are used to evaluate the SST. Specification of atmospheric parameters, such as air temperature and humidity, over which the ocean has direct influence, is avoided. The model simulates the major features of the observed tropical Pacific SST. The seasonal evolution of these features is generally captured by the model. Analysis of the results demonstrates the control the ocean has over the surface heat flux from ocean to atmosphere and the crucial role that dynamics play in determining the mean SST in the equatorial Pacific. The sensitivity of the model to perturbations in the surface heat flux, cloud cover specification, diffusivity, and mixed layer depth is discussed.

Seager, Richard↗