Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diffraction systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Compact, Passively Q-Switched Nd:YAG Laser for the MESSENGER Mission to the Planet Mercury

A compact, passively Q-switched Nd:YAG laser has been developed for the Mercury Laser Altimeter (MLA) instrument which is an instrument on the MESSENGER mission to the planet Mercury. The laser achieves 5.4 percent efficiency with a near diffraction limited beam. It has passed all space flight environmental tests at system, instrument, and satellite integration. The laser design draws on a heritage of previous laser altimetry missions, specifically ISESAT and Mars Global Surveyor; but incorporates thermal management features unique to the requirements of an orbit of the planet Mercury.

Krebs, Danny J.↗

Thermochemistry of Rare Earth Silicates for Environmental Barrier Coatings

Rare earth silicates are promising candidates as environmental protective coatings (EBCs) for silica-forming ceramics and composites in combustion environments since they are predicted to have lower reactivity with the water vapor combustion products. The reactivity of rare earth silicates is assessed by the thermodynamic activity of the silica component which is best measured by Knudsen effusion mass spectrometry (KEMS). Here, we discuss a novel method based on a reducing agent to increase the partial pressure of SiO(g) which is then used to calculate thermodynamic activity of silica in Y2O3-SiO2 and Yb2O3-SiO2 systems. After the KEMS measurements, samples were probed by X-ray diffraction and their phase content was calculated from Rietveld refinement.

Rare Earth Silicates↗

The StarLight Space Interferometer: Optical design and performance modeling

The StarLight mission aimed to place the first formation flying optical interferometer into space in year 2006. Utilizing two spacecraft to form a long baseline Michelson interferometer, it would measure white light fringes on a number of partially resolved stars of magnitudes >5 in the wavelength range 600 to 1000nm. The interferometer baseline is variable between 30 and 125 m, and also has a fixed 1 m mode. The spacecraft are flown in a parabolic geometry which requires an optical delay line to build up more than 14m of delay on one arm of the interferometer. To obtain high fringe visibility, starlight wavefront, pointing and intensity must be preserved through 22 reflections from mirrors and beamsplitters. The alignment of a total of 27 optics is maintained through careful thermal design and the use of two actuated mirrors on each arm. This paper describes the optical layout in depth, including the beam combiner design which allows star tracking, optical system alignment and fringe formation on a single CCD. The effects of diffraction of the starlight transferred from a distant spacecraft and from optical surface imperfections are modeled. Other contributors to the visibility budget and the resulting variation of fringe visibility across the focal plane are discussed .

StarLight↗

Additive Manufacturing and Working Fluid Characterization of Ceramic Heat Pipes

In this work, additively manufactured aluminum nitride (AlN) ceramic heat pipes are developed to improve spacecraft heat rejection capabilities beyond the current state-of-the-art metal systems. Printed AlN parts are characterized via SEM, EDS, X-ray diffraction, optical profilometry, thermal conductivity, and emissivity testing. AlN 3D-printed parts are also tested for compatibility with aluminum bromide, aluminum chloride, and iodine, among other proposed working fluids at 500-600 K in vacuum.

Thermal management↗

Absolute calibration technique for broadband ultrasonic transducers

Calibrating an ultrasonic transducer can be performed with a reduced number of calculations and testing. A wide-band pulser is connected to an ultrasonic transducer under test to generate ultrasonic waves in a liquid. A single frequency is transmitted to the electrostatic acoustic transducer (ESAT) and the voltage change produced is monitored. Then a broadband ultrasonic pulse is generated by the ultrasonic transducer and received by the ESAT. The output of the ESAT is amplified and input to a digitized oscilloscope for fast Fourier transform. The resulting plot is normalized with the monitored signal from the single frequency pulse. The plot is then corrected for characteristics of the membrane and diffraction effects. The transfer function of the final plot is determined. The transfer function gives the final sensitivity of the ultrasonic transducer as a function of frequency. The advantage of the system is the speed of calibrating the transducer by a reduced number of measurements and removal of the membrane and diffraction effects.

Yost, William T.↗

Crystallographic variant mapping using precession electron diffraction data

In this work, we developed three methods to map crystallographic variants of samples at the nanoscale by analyzing precession electron diffraction data using a high-temperature shape memory alloy and a VO2 thin film on sapphire as the model systems. The three methods are (I) a user-selecting-reference pattern approach, (II) an algorithm-selecting-reference-pattern approach, and (III) a k-means approach. In the first two approaches, Euclidean distance, Cosine, and Structural Similarity (SSIM) algorithms were assessed for the diffraction pattern similarity quantification. We demonstrated that the Euclidean distance and SSIM methods outperform the Cosine algorithm. We further revealed that the random noise in the diffraction data can dramatically affect similarity quantification. Denoising processes could improve the crystallographic mapping quality. With the three methods mentioned above, we were able to map the crystallographic variants in different materials systems, thus enabling fast variant number quantification and clear variant distribution visualization. The advantages and disadvantages of each approach are also discussed. We expect these methods to benefit researchers who work on martensitic materials, in which the variant information is critical to understand their properties and functionalities.

Crystallographic variant mapping↗

A fixed-target platform for serial femtosecond crystallography in a hydrated environment

For serial femtosecond crystallography at X-ray free-electron lasers, which entails collection of single-pulse diffraction patterns from a constantly refreshed supply of microcrystalline sample, delivery of the sample into the X-ray beam path while maintaining low background remains a technical challenge for some experiments, especially where this methodology is applied to relatively low-ordered samples or those difficult to purify and crystallize in large quantities. This work demonstrates a scheme to encapsulate biological samples using polymer thin films and graphene to maintain sample hydration in vacuum conditions. The encapsulated sample is delivered into the X-ray beam on fixed targets for rapid scanning using the Roadrunner fixed-target system towards a long-term goal of low-background measurements on weakly diffracting samples. As a proof of principle, we used microcrystals of the 24 kDa rapid encystment protein (REP24) to provide a benchmark for polymer/graphene sandwich performance. The REP24 microcrystal unit cell obtained from our sandwiched in-vacuum sample was consistent with previously established unit-cell parameters and with those measured by us without encapsulation in humidified helium, indicating that the platform is robust against evaporative losses. While significant scattering from water was observed because of the sample-deposition method, the polymer/graphene sandwich itself was shown to contribute minimally to background scattering.

36 MATERIALS SCIENCE↗

Development of a Terrain Mapping/Crater Evolution Measurement using Diffractive Optical Elements

When landing on the moon, understanding the interaction of the engine exhaust plume with the lunar surface is critical for the success of the descent and landing flight phases. Two evaluation tools currently used are computational simulations and ground test measurements. Computational simulations require experimental measurements for comparison/validation, but ground test measurements cannot accurately emulate all aspects of an actual lunar landing; flight tests remain the only method of obtaining fully representative data. A terrain mapping/crater evolution measurement system was developed for potential inclusion on a future lander mission. This system uses two stereo cameras viewing a laser dot grid pattern projected on the ground, where the grid is created by shining a laser through one or two diffractive optical elements. CAD simulations of the stereo imaging system are first used to validate the proposed design. Laboratory testing of the system using both a large-scale fixed-geometry crater and a small-scale evolving-geometry crater validate the use of the system for terrain mapping measurements, and for its potential inclusion on a future lander mission.

Joshua M Weisberger↗

Development of a Terrain Mapping/Crater Evolution Measurement using Diffractive Optical Elements

When landing on the moon, understanding the interaction of the engine exhaust plume with the lunar surface is critical for the success of the descent and landing flight phases. Two evaluation tools currently used are computational simulations and ground test measurements. Computational simulations require experimental measurements for comparison/validation, but ground test measurements cannot accurately emulate all aspects of an actual lunar landing; flight tests remain the only method of obtaining fully representative data. A terrain mapping/crater evolution measurement system was developed for potential inclusion on a future lander mission. This system uses two stereo cameras viewing a laser dot grid pattern projected on the ground, where the grid is created by shining a laser through one or two diffractive optical elements. CAD simulations of the stereo imaging system are first used to validate the proposed design. Laboratory testing of the system using both a large-scale fixed-geometry crater and a small-scale evolving-geometry crater validate the use of the system for terrain mapping measurements. High-speed, front-illumination shadow particle tracking of particles ejected from the evolving geometry crater is also performed, demonstrating another diagnostic that can be used to further the understanding of plume-surface interactions.

Joshua M Weisberger↗

Phase Sensitive X-Ray Diffraction Imaging Study of Protein Crystals

The study of defects and growth of protein crystals is of importance in providing a fundamental understanding of this important category of systems and the rationale for crystallization of better ordered crystals for structural determination and drug design. Yet, as a result of the extremely weak scattering power of x-rays in protein and other biological macromolecular crystals, the extinction lengths for those crystals are extremely large and, roughly speaking, of the order of millimeters on average compared to the scale of micrometers for most small molecular crystals. This has significant implication for x-ray diffraction and imaging study of protein crystals, and presents an interesting challenge to currently available x-ray analytical techniques. We proposed that coherence-based phase sensitive x-ray diffraction imaging could provide a way to augment defect contrast in x-ray diffraction images of weakly diffracting biological macromolecular crystals. I shall examine the principles and ideas behind this approach and compare it to other available x-ray topography and diffraction methods. I shall then present some recent experimental results in two model protein systems-cubic apofemtin and tetragonal lysozyme crystals to demonstrate the capability of the coherence-based imaging method in mapping point defects, dislocations, and the degree of perfection of biological macromolecular crystals with extreme sensitivity. While further work is under way, it is intended to show that the observed new features have yielded important information on protein crystal perfection and nucleation and growth mechanism otherwise unobtainable.

Hu, Z. W.↗

Ptychographic atomic electron tomography: Towards three-dimensional imaging of individual light atoms in materials

Through numerical simulations, we demonstrate the combination of ptychography and atomic electron tomography as an effective method for low dose imaging of individual low-Z atoms in three dimensions. After generating noisy diffraction patterns with multislice simulations of an aberration-corrected scanning transmission electron microscope through a 5-nm zinc-oxide nanoparticle, we have achieved three-dimensional (3D) imaging of individual zinc and oxygen atoms and their defects by performing tomography on ptychographic projections. The methodology has also been simulated in 2D materials, resolving individual sulfur atoms in vertical WS 2 /WSe 2 van der Waals heterostructure with a low total electron dose where annular-dark-field images fail to resolve. Overall, we envision that the development of this method could be instrumental in studying the precise 3D atomic structures of radiation sensitive systems and low-Z atomic structures such as 2D heterostructures, catalysts, functional oxides, and glasses.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stabilization of collinear ferromagnetic order in Ir-doped triple-layer ruthenate Sr 4 Ru 3 O 10

The triple-layer Sr 4 Ru 3 O 10 is a spin-orbit-coupled metal featuring an intriguing combination of ferromagnetic and metamagnetic states. Here we report a comprehensive study of single-crystal neutron and x-ray diffraction on Sr 4 Ru 3 O 10 with 4% iridium doping. The system crystallizes in an orthorhombic Bbem structure in which two triple layers are related by a base centering symmetry operation within one unit cell. The 4% Ir doping at the Ru site sensitively alters the structural balance between the RuO 6 layers, as such the two outer-layer octahedra rotate 6.7° about the c axis, while the central-layer one rotates in the opposite direction by 11.0°. The increased lattice distortion stabilizes a collinear ferromagnetic state with magnetic moments fully aligned along the c axis. The emerging perpendicular magnetic anisotropy naturally increases the critical field for the inplane metamagnetic transition to 4.5 Tesla. All results highlight the critical linkage between the magnetic properties and underlying lattice through orbital degrees of freedom, as well as the enhanced spin orbit coupling due to heavier 5d ions. Our observation provides a viable route for an efficient manipulation of the magnetic states with functionalities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optics Program Modified for Multithreaded Parallel Computing

A powerful high-performance computer program for simulating and analyzing adaptive and controlled optical systems has been developed by modifying the serial version of the Modeling and Analysis for Controlled Optical Systems (MACOS) program to impart capabilities for multithreaded parallel processing on computing systems ranging from supercomputers down to Symmetric Multiprocessing (SMP) personal computers. The modifications included the incorporation of OpenMP, a portable and widely supported application interface software, that can be used to explicitly add multithreaded parallelism to an application program under a shared-memory programming model. OpenMP was applied to parallelize ray-tracing calculations, one of the major computing components in MACOS. Multithreading is also used in the diffraction propagation of light in MACOS based on pthreads [POSIX Thread, (where "POSIX" signifies a portable operating system for UNIX)]. In tests of the parallelized version of MACOS, the speedup in ray-tracing calculations was found to be linear, or proportional to the number of processors, while the speedup in diffraction calculations ranged from 50 to 60 percent, depending on the type and number of processors. The parallelized version of MACOS is portable, and, to the user, its interface is basically the same as that of the original serial version of MACOS.

Lou, John↗

Silicon nitride-aluminum oxide solid solution (SiAION) formation and densification by pressure sintering

Stirred-ball-mill-blended Si3N4 and Al2O3 powders were pressure sintered in order to investigate the mechanism of solid solution formation and densification in the Si3N4-Al2O3 system. Powder blends with Si3N4:Al2O3 mole ratios of 4:1, 3:2, and 2:3 were pressure sintered at 27.6-MN/sq m pressure at temperatures to 17000 C (3090 F). The compaction behavior of the powder blends during pressure sintering was determined by observing the density of the powder compact as a function of temperature and time starting from room temperature. This information, combined with the results of X-ray diffraction and metallographic analyses regarding solutioning and phase transformation phenomena in the Si3N4-Al2O3 system, was used to describe the densification behavior.

Yeh, H. C.↗

Construction of Prototype Lightweight Mirrors

This contract and the work described was in support of a Seven Segment Demonstrator (SSD) and demonstration of a different technology for construction of lightweight mirrors. The objectives of the SSD were to demonstrate functionality and performance of a seven segment prototype array of hexagonal mirrors and supporting electromechanical components which address design issues critical to space optics deployed in large space based telescopes for astronomy and for optics used in spaced based optical communications systems. The SSD was intended to demonstrate technologies which can support the following capabilities; Transportation in dense packaging to existing launcher payload envelopes, then deployable on orbit to form space telescope with large aperture. Provide very large (less than 10 meters) primary reflectors of low mass and cost. Demonstrate the capability to form a segmented primary or quaternary mirror into a quasi-continuous surface with individual subapertures phased so that near diffraction limited imaging in the visible wavelength region is achieved. Continuous compensation of optical wavefront due to perturbations caused by imperfections, natural disturbances, and equipment induced vibrations/deflections to provide near diffraction limited imaging performance in the visible wavelength region. Demonstrate the feasibility of fabricating such systems with reduced mass and cost compared to past approaches. While the SSD could not be expected to satisfy all of the above capabilities, the intent was to start identifying and understanding new technologies that might be applicable to these goals.

Robinson, William G.↗

Adaptive Full Aperture Wavefront Sensor Study

This grant and the work described was in support of a Seven Segment Demonstrator (SSD) and review of wavefront sensing techniques proposed by the Government and Contractors for the Next Generation Space Telescope (NGST) Program. A team developed the SSD concept. For completeness, some of the information included in this report has also been included in the final report of a follow-on contract (H-27657D) entitled "Construction of Prototype Lightweight Mirrors". The original purpose of this GTRI study was to investigate how various wavefront sensing techniques might be most effectively employed with large (greater than 10 meter) aperture space based telescopes used for commercial and scientific purposes. However, due to changes in the scope of the work performed on this grant and in light of the initial studies completed for the NGST program, only a portion of this report addresses wavefront sensing techniques. The wavefront sensing techniques proposed by the Government and Contractors for the NGST were summarized in proposals and briefing materials developed by three study teams including NASA Goddard Space Flight Center, TRW, and Lockheed-Martin. In this report, GTRI reviews these approaches and makes recommendations concerning the approaches. The objectives of the SSD were to demonstrate functionality and performance of a seven segment prototype array of hexagonal mirrors and supporting electromechanical components which address design issues critical to space optics deployed in large space based telescopes for astronomy and for optics used in spaced based optical communications systems. The SSD was intended to demonstrate technologies which can support the following capabilities: Transportation in dense packaging to existing launcher payload envelopes, then deployable on orbit to form a space telescope with large aperture. Provide very large (greater than 10 meters) primary reflectors of low mass and cost. Demonstrate the capability to form a segmented primary or quaternary mirror into a quasi-continuous surface with individual subapertures phased so that near diffraction limited imaging in the visible wavelength region is achieved. Continuous compensation of optical wavefront due to perturbations caused by imperfections, natural disturbances, and equipment induced vibrations/deflections to provide near diffraction limited imaging performance in the visible wavelength region. Demonstrate the feasibility of fabricating such systems with reduced mass and cost compared to past approaches.

Robinson, William G.↗

An ultrahigh-accuracy body pointing system for the Large Space Telescope

The Large Space Telescope (LST) program is aimed at placing a three-meter diffraction-limited telescope in a 270-nm orbit to perform astronomical observations that are not possible with earth-based telescopes. A complex simulation model is described which was developed to determine whether the stringent pointing stability requirements could be met. The model (programmed on a hybrid computer) included detailed dynamic representation of control moment gyros (CMGs) and reaction wheels (RWs), including their noise characteristics; dynamic sensor representation (including noise); shockmounts for the CMG actuators; detailed representation of an image motion compensation system; and a detailed flexible body vehicle model. Stability and performance studies based on the simulation model showed that the body pointing system will meet LST requirements in the presence of CMG vibrational disturbances and sensor noise. The recommended system consists of three orthogonally mounted RWs for primary short-term control, and a cluster of CMG actuators for continuous RW desaturation and vehicle maneuvering.

Rybak, S. C.↗