Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DER systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Tunable Localized Charge Transfer Excitons in Nanoplatelet–2D Chalcogenide van der Waals Heterostructures

Observation of interlayer, charge transfer (CT) excitons in van der Waals heterostructures (vdWHs) based on 2D–2D systems has been well investigated. While conceptually interesting, these charge transfer excitons are highly delocalized and spatially localizing them requires twisting layers at very specific angles. This issue of localizing the CT excitons can be overcome via making nanoplate–2D material heterostructures (N2DHs) where one of the components is a spatially quantum confined medium. Here, we demonstrate the formation of CT excitons in a mixed dimensional system comprising MoSe 2 and WSe 2 monolayers and CdSe/CdS-based core/shell nanoplates (NPLs). Spectral signatures of CT excitons in our N2DHs were resolved locally at the 2D/single-NPL heterointerface using tip-enhanced photoluminescence (TEPL) at room temperature. By varying both the 2D material and the shell thickness of the NPLs and applying an out-of-plane electric field, the exciton resonance energy was tuned by up to 100 meV. Finally, our finding is a significant step toward the realization of highly tunable N2DH-based next-generation photonic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility Analysis of Converter-Interfaced Combined Heat and Power System

As a promising new design concept, the converter-interfaced combined heat and power (CHP) system is coupled to the bulk grid through a rectifier and a grid-ready tied inverter. Compared to the traditional directly-coupled CHP system, it removes the requirement for oversizing the CHP generator, limits the short-circuit contribution of the generator and simplifies the grid integration process of CHP system. This paper evaluates the economic benefits of this concept by calculating the annualized Return-on-Investment (ROI) and comparing it to the directly-coupled system. The economic analysis includes timeseries simulations to compute energy transactions with the bulk grid as well as sizing the equipment to calculate the capital and operational costs. Obtained results indicate that in majority of user cases evaluated, the converter-interfaced CHP systems can provide better ROI than directly-coupled systems. Given the additional technical benefits provided by inverter-based distributed energy resources (DERs), the proposed concept is proved to be technically viable and economically feasible.

03 NATURAL GAS↗

Renewable Energy and Storage Cybersecurity Research (RESCue) Pilot Final Report

The Renewable Energy and Storage Cybersecurity Research (RESCue) project is a collaborative effort aimed at securing the rapidly growing deployment of distributed energy resources (DERs) and transmission-connected hybrid renewable energy systems against escalating cyber threats. This project brings together major original equipment manufacturers (OEMs) of wind, solar, and energy storage, along with major asset owners and DOE National Laboratories, to collectively identify cyber threats, assess risks, and develop robust cybersecurity strategies and solutions. This publication the final report for the first year of the project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Solar in Tamil Nadu

With India’s ambitious renewable energy targets and decreasing rooftop solar prices, customer adoption of rooftop solar on Tamil Nadu’s distribution network is set to increase in the coming years. With that comes the challenge of how to assess the impact of these emerging distributed energy resources. In an effort to help with such an assessment, NREL has created a holistic analysis framework for Tamil Nadu Generation and Distribution Company (TANGEDCO). The Emerging technologies Management and Risk evaluation on distribution Grids Evolution (EMeRGE) analysis framework and tool will help TANGEDCO and other distribution companies (DISCOMs) in India analyze new interconnection applications and evaluate the system risk impact over time with new emerging DERs.

Children's Investment Fund Foundation↗

Storage Enabled Flexibility of Conventional Generation Assets (StorFlex)

The power systems have faced progressively more demanding operational requirements over the last two decades. Several factors contribute to these challenging operating conditions, including load growth, aging infrastructure, increasing penetrations of distributed energy resources (DERs), electrification of the economy, and policy initiatives such as decarbonization. The power system and its components must provide high operational flexibility to mitigate these challenges. For example, the proliferation of intermittent DERs such as wind and solar has increased the need for conventional generation assets like hydropower plants to respond to sudden load-generation imbalances. The higher flexibility requirements for hydropower plants cause more wear and tear, potentially shortening the useful lifespan of hydropower turbines. To reduce the need for hydropower plants to follow sudden changes in the dispatch signal, we investigate their combined operation with the energy storage systems (ESSs; “ESS-based hybridization”). Our analyses focuses on improving the lifespan of hydropower plants through ESS-based hybridization. Wear and tear on hydropower turbines (particularly Francis turbines) is modeled using a loss-of-life concept that is based on damage experienced by the turbine due to various cycles of operation. Then, we show that using ESSs to offset some of the high variation increases the remaining life of the hydropower plants. To demonstrate this, a few modeling tools were developed for this work: (1) a dynamic model for various components of the turbine and its governor; (2) a control strategy that assigns a slow-varying dispatch signal to a hydropower unit versus a fastmoving signal to ESS, such that the overall power request remains the same; and (3) models for the financial analysis to quantify the economic merits of such a framework. We used the models we developed to analyze the dispatch pattern of an actual hydropower plant with a power output of 50 MW and a head height of 152 m. This work showed that ESS-based hybridization could extend the life of the hydropower plant by 5% on average. This extension in life was then used to estimate the economic benefit in terms of cost deferrals associated with hydropower plant maintenance and replacement: on average, $3.6 million. Sensitivity analysis with respect to the size of ESS and cost of turbines was performed to show the variation in benefits over the range of turbine costs and ESS sizes. Crucially, stacking damage reduction and lifetime extension with other ESS value streams such as providing ancillary services could substantially increase the financial benefits of ESS-based hybridization. The higher costs associated with ESS of appropriate size would make more financial sense when multiple value streams are stacked and co-optimized to extract the maximum benefit. This dimension will be explored in future work.

13 HYDRO ENERGY↗

Co-optimization of repairs and dynamic network reconfiguration for improved distribution system resilience

In this work, a post-disaster distribution system repair and restoration (DSRR) strategy is proposed to improve distribution system resilience. The DSRR strategy is formulated as a two-stage optimization. The first stage is a comprehensive co-optimization of repair crew scheduling, dynamic network reconfiguration, and distributed energy resource (DER) dispatch based on the forecast load profile. The goal is to minimize the accumulative operating cost caused by the load reduction payment as well as DER operating cost. In particular, since the number of available repair crews is usually smaller than the number of faulted lines after a disaster event, the DSRR strategy determines the optimal scheduling for repairing faulted lines. The second stage is a re-dispatch of the DER power output and load shedding based on the real-time load demand of each bus. The proposed algorithm is validated by case studies of the IEEE 33-bus and 123-bus test systems. We consider those scenarios in which faults occur in multiple heavy-loaded feeders. The simulation results demonstrate that the DSRR strategy effectively coordinate the repair scheduling, network reconfiguration and load shedding to minimize the operating cost.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Programmable intrusion detection for distributed energy resources in cyber–physical networked microgrids

We present a programmable intrusion detection method is presented to identify the malicious attacks to distributed energy resources (DERs) in the cyber-physical networked microgrids. The proposed method injects small programmable signals into the system and uses the response to identify abnormal conditions. Because of the low or even zero inertia induced by integrations of DER power-electronic-interfaces, microgrids have very limited resilience capability; and thus, being sensitive to attacks. One microgrid's malfunction caused by attacks can easily propagate to its neighboring systems when several microgrids are connected, leading to catastrophic electricity supply failures. Through the presented method, malicious intrusions can be effectively detected, located, and defended for securing microgrids. Theoretical derivations are provided to define the programmable detection rules. The detection rule is easy and flexible to update, making it difficult for attack actors to gain the knowledge of the detection rules, in order to avoid being detected. Numerical results on a cyber-physical networked microgrids system show that the proposed method is effective and efficient in precisely locating intrusion attacks to the microgrids system.

42 ENGINEERING↗

Protecting Customer Privacy Through Distributed Energy Resource Anonymization

Due to their stochastic nature, the increase of Renewable Energy Resources (RERs) as a primary source of energy for power grids creates challenges regarding the reliability and resilience of the system. In order to combat these obstacles, expansion of Distributed Energy Resources (DERs) and their participation in Demand Response (DR) programs is necessary. Widespread participation requires prioritizing customer privacy and addressing concerns that may arise regarding communication between DERs and the Grid Service Provider (GSP). This paper discusses the use of flow reservation resources to split the operating cycles of DER load profiles into unique phases. The splitting of phases increases anonymization of the DERs by making it more difficult to determine the individual characteristics of the device. We discuss an example of this using simulated DER load profile data and examine the resulting effectiveness by using a machine learning algorithm for classification, called Support Vector Machine (SVM).

Distributed Energy Resource, Anonymization, Renewa↗

Analyzing impact of $\mathrm{DER}$ on $\mathrm{FIDVR}$ - comparison of $\mathrm{EMT}$ simulation of a combined transmission and distribution grid with aggregated positive sequence models

The increase in percentage of distributed energy resources (DERs) brings in a degree of uncertainty in bulk power system planning and operations. Further, the presence of 1 - φ induction motors introduces the possibility of motor stalling and fault induced delayed voltage recovery (FIDVR). With newer versions of IEEE Std 1547™ there can be the opportunity to obtain dynamic voltage support from DERs. In this report, the impact of DERs providing dynamic voltage on the dynamic behavior of 1 - φ induction motors is examined in detail along with an exploration of the need for simulation platforms that go beyond positive sequence. The studies discussed here are carried out both in detailed electromagnetic time domain and in positive sequence domain for comparison.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anisotropic magnetocaloric effect and critical behavior in CrCl 3

We report anisotropic magnetocaloric effect and magnetic critical behavior in the van der Waals crystal CrCl 3 . The maximum magnetic entropy change $-ΔS^{max}_M ~ 14.6 J kg -1 K -1 and the relative cooling power RCP ~ 340.3 J kg -1 near T c with a magnetic field change of 5 T are much larger when compared to CrI 3 or CrBr 3 . The rescaled ΔS M (T, H) curves collapse onto a universal curve, confirming the second-order ferromagnetic transition. Finally, further critical behavior analysis around T c presents a set of critical exponents β = 0.28 (1) with T c = 19.4 (2) K, γ = 0.89 (1) with T c = 18.95 (8) K, and δ = 4.6 (1) at T c = 19 K , which are close to those of the theoretical tricritical mean-field model.

2-dimensional systems↗

Virtual sensing of wind turbine hub loads and drivetrain fatigue damage, Virtuelle Sensoren für die Messung von Hauptwellenlasten und Ermüdungsschäden im Antriebstrang von Windenergieanlagen

Abstract: This paper presents a Digital Twin for virtual sensing of wind turbine aerodynamic hub loads, as well as monitoring the accumulated fatigue damage and remaining useful life in drivetrain bearings based on measurements of the Supervisory Control and Data Acquisition (SCADA) and the drivetrain condition monitoring system (CMS). The aerodynamic load estimation is realized with data-driven regression models, while the estimation of local bearing loads and damage is conducted with physics-based, analytical models. Field measurements of the DOE 1.5 research turbine are used for model training and validation. The results show low errors of 6.4% and 1.1% in the predicted damage at the main and the generator side high-speed bearing respectively. Zusammenfassung: In diesem Aufsatz wird ein digitaler Zwilling für Windenergieanlagen vorgestellt, welcher die virtuelle Erfassung der Hauptwellenlasten und die Zustandsüberwachung von Ermüdungschäden und der verbleibende Nutzungsdauer der Antriebsstranglager ermöglicht. Der digital Zwilling nutzt Messdaten des Supervisory Control and Data Acquisition (SCADA) Systems und des Zustandsüberwachungssystems des Antriebsstranges (CMS). Die Berechnung der Hauptwellenlasten ist mit datenbasierten Regressionsmodellen umgesetzt, während die Berechnung der Lagerkräfte und der Ermüdungsschaden mit physikbasierten Modelle durchgeführt wird. Für die Modellentwicklung und -validierung werden Feldmessdaten der DOE 1.5MW Turbine eingesetzt. Die Abweichungen in den Ermüdungsschäden am Hauptwellenlager und am Generatorwellenlager betragen lediglich 6,4% beziehungsweise 1,1%.

17 WIND ENERGY↗

Parameter-free treatment of a layered correlated van der Waals magnet: CrPS 4

The electronic and magnetic structure of CrPS 4 , a two-dimensional (2D) magnetic semiconductor is examined by employing the SCAN meta-GGA density functional. We find the resulting magnetic moment and band gap are in excellent agreement with experiment. From the bulk magnetic configurations, we confirm the experimentally observed A-type antiferromagnetic (A-AFM) ordered ground state with a magnetic moment of 2.78 µ B per chromium atom and band gap of 1.34 eV. To gain insight into the evolution of the ground state with layers, the total energy of each magnetic configuration is calculated for a variety of thicknesses. Monolayer CrPS 4 is predicted to be a ferromagnetic insulator with a band gap of 1.37 eV, and A-AFM for bilayer and trilayer, with band gaps of 1.35 and 1.30 eV, respectively. The electronic structure is reported for the single-, two-, and three-layer and bulk CrPS 4 . Finally, we explore the optical properties of the 2D structure and report the dielectric tensor components and Kerr parameters for the monolayer.

2-dimensional systems↗

Co-Simulation of PSS/E, OpenDSS, and PSCAD for Power Systems Stability Analysis With Inverter-Based Resources: Preprint

The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamically robust coordinated set point tracking of distributed DERs at point of common coupling

Low-inertia operation of small-scale power systems, such as a microgrid or a portion of a long feeder, requires careful coordination of the controller performance of the constituting devices. This challenge is exacerbated in microgrids serving the functionalities of a conventional synchronous-based generation unit while comprised of smaller DERs operating mainly interfaced through power electronics converters. This paper builds on the idea of set point modulation and proposes a two-level control strategy that aims to achieve superior performance at the point of common coupling (PCC) of microgrids by combining a local control level with a distributed and coordinated level. Several case studies on both AC and DC systems, the CIGRE low-voltage benchmark system as the AC system and a test DC microgrid, validate the performance of the proposed approach. The real-world applicability of the approach is established via a high-fidelity power hardware-in-the-loop (PHIL) experimental setup and an application case study on grid frequency regulation. The proposed approach enables a microgrid to participate in ancillary service provisions where speed and quality of regulation are critical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Perspective: Magnon-magnon coupling in hybrid magnonics

The internal coupling of magnetic excitations (magnons) with themselves has created a new research sub-field in hybrid magnonics, i.e., magnon-magnon coupling, which focuses on materials discovery and engineering for probing and controlling magnons in a coherent manner. This is enabled by, one, the abundant mechanisms of introducing magnetic interactions, with examples of exchange coupling, dipolar coupling, Ruderman–Kittel–Kasuya–Yosida (RKKY) coupling, and Dzyaloshinskii–Moriya interaction (DMI) coupling, and two, the vast knowledge of how to control magnon band structure, including field and wavelength dependences of frequencies, for determining the degeneracy of magnon modes with different symmetries. In particular, we discuss how magnon-magnon coupling is implemented in various materials systems, with examples of magnetic bilayers, synthetic antiferromagnets, nanomagnetic arrays, layered van der Waals magnets, and (DMI spin-orbit torque materials) in magnetic multilayers. Here, we then introduce new concept of applications for these hybrid magnonic materials systems, with examples of frequency up/down conversion and magnon-exciton coupling, and discuss what properties are desired for achieving those applications.

Materials science↗

Bridging the Gap on Data and Analysis for Distribution System Planning: Information That Utilities Can Provide Regulators, State Energy Offices and Other Stakeholders

Electric utilities conduct planning annually to ensure their distribution system meets technical standards, policies, and regulations; addresses forecasted grid conditions; satisfies customer needs; and advances utility priorities. The plan identifies grid deficiencies, analyzes potential solutions, and prioritizes capital investments and other expenditures. About 20 U.S. states and jurisdictions require regulated utilities to file some type of distribution system plan with the public utility commission for review. Requirements for sharing distribution system data and analyses vary widely, from few specific requirements to a detailed list of information that must be provided. While utilities conduct extensive analysis to develop distribution system plans, in most jurisdictions regulators and stakeholders do not know what data are available and how the utility uses the data in planning and investing. This report aims to bridge the gap by increasing understanding of the types of data and analyses utilities employ to develop distribution system plans and how the information affects their decision-making. The report describes information that states and stakeholders can ask for related to 11 data categories: -Forecasting loads and distributed energy resources (DERs) -Scenario analysis -Worst-performing circuits -Asset management strategy -Hosting capacity analysis -Value of DERs -Grid needs assessment -Cost-effectiveness framework for investments -Distribution system investment strategy and implementation -Geotargeted programs -Non-wires alternatives procurements.

24 POWER TRANSMISSION AND DISTRIBUTION↗