Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DAYLIGHTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Hybrid Geo-Solar GeoVision Case Study Analysis: CSP power plant with geothermal boiler feedwater heating

While stand-alone geothermal power plants provide reliable 24/7 baseload operation, most systems are subject to slow resource decline, and air-cooled plant performance suffers in hot weather. Stand-alone solar thermal power plants operate using a consistent, albeit intermittent, solar resource that requires thermal storage for reliability. Hybrid geothermal-solar power plants offer a number of potential advantages including boosted power generation during daylight hours when demand is typically greatest, the ability to share a common power block, and no requirement for thermal storage. The GeoVision hybrid systems analysis focused on aspects of hybrid technology that can increase the utilization of geothermal energy. Important aspects of the hybrid systems analysis therefore include evaluating conditions where hybrid technologies could decrease the costs of geothermal power generation and/or increase the viability of low temperature geothermal resources.

14 SOLAR ENERGY↗

Integrated Design Team Guide to Realizing Over 75% Lighting Energy Savings in High-Performance Office Buildings (Fact Sheet)

This checklist packet is a team-focused guide to realizing energy savings in high-performance office buildings through carefully considered lighting and control design. The checklists should be distributed among the integrated project team members, including the owner, lighting designer and engineer, commissioning agent, and facility manager, at the beginning of a project and referred toregularly during design meetings and drawing reviews. The checklists are arranged by key design considerations (daylighting, occupancy, task) and key integration points (energy goal, sequence of operations). Each action or question is related to a design stage during which failure to act could jeopardize energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design and Performance of an Image Processing Occupancy Sensor

The design and performance of a novel image-processing occupancy sensor (IPOS) based on production-grade embedded hardware are described. The IPOS overcomes several issues related to traditional passive infrared (PIR) and ultrasonic-based motion sensors. It also provides a rich set of feedback signals that more sophisticated applications can use for occupant-optimized lighting, daylighting,temperature,and ventilation control, as well as with building security systems. The IPOS was tested as part of an integrated system consisting of a building energy management system (EMS) alongside a pair of PIR sensors produced by different manufacturers. IPOS output was fed to the EMS via the building automation and controls network (BACnet) and logged alongside the PIR outputs in an officeenvironment over several days. Tests suggest the IPOS device identifies occupancy events better than two commercial PIR sensors (94.1% accuracy compared to 73.1% on average). Also, IPOS could correctly identify stationary occupants whereas the PIR sensors could not.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Promising Innovations for the Lighting Profession: Big Data, New Tools

The use of parametric modeling is increasing as computing power increases, supporting the use of generative design software to design shoes and plan architectural spaces. This big data inclusive design process is used for daylighting studies, and is ripe for development by the larger lighting community.

Lighting, generative design, virtual reality↗

Lifting the Garage Door on Spawn, An Open-Source BEM-Controls Engine

Spawn is the latest whole-building energy simulation engine developed by the US Department of Energy, National Labs and industry. Whereas EnergyPlus was designed as a successor to DOE-2, Spawn is not a direct successor of–nor is it intended as an imminent replacement for– EnergyPlus. Instead, Spawn reuses parts of EnergyPlus while supporting new use cases in HVAC and controls. Spawn is intended to provide several capabilities that significantly advance beyond EnergyPlus. It is intended to support the evaluation of novel HVAC and district energy systems in a more physically realistic way. Critically, it can model control in a physically realistic way, using portable specifications that can be compiled for execution on control platforms. Spawn is also intended to support co-simulation in an intrinsic way to enable integration with third-party models. This paper describes the software architecture of Spawn from model authoring to compilation and simulation. It explains how Spawn reuses the envelope and daylighting modules of EnergyPlus and couples them to HVAC and control models from the Modelica Buildings Library using the Functional Mockup Interface (FMI) standard. It presents a number of examples that: i) validate Spawn’s coupled simulation approach by comparing its results to those of EnergyPlus, ii) illustrate the Spawn methodology for modeling and simulating HVAC systems, and iii) evaluate the performance of Spawn’s Quantized State System (QSS) time integration algorithms

Wetter, Michael↗

A Python Library for Radiance Matrix-based Simulation Control and EnergyPlus Integration

Radiance matrix-based methods enable efficient parametric simulations, allowing users to vary sky conditions, fenestration systems, and other model parameters at a minimal cost to computation. However, the steep learning curve and complex workflow hinder the widespread adoption of matrix-based methods. The frads Python library with a series of command-line tools was developed to automate the entire matrix-based simulation process, lowering entry barriers and reducing human error. Co-simulation between EnergyPlus and Radiance was also enabled using the Python library from EnergyPlus. Key Innovations • Command-line based automation of Radiance matrix-based simulation methods • Python library facilitates broader adoption of Radiance matrix-based simulation methods • Radiance EnergyPlus run-time integration enabling the modeling of advanced control systems Practical Implications The frads library, with associated command-line tools, provides practitioners with the capability to easily adopt and use Radiance matrix-based simulation methods for various daylighting, solar control, and energy-related evaluations. Frads' current form is designed for 1) users familiar with a command-line interface and 2) software developers to integrate the matrix-based methods into existing software packages.

Wang, Taoning↗

Survey of Time Shift Detection Algorithms for Measured PV Data

In this research, three variations of time shift detection algorithms were tested for their ability to detect time shift issues (including daylight savings time and random time shifts) in measured PV data sets. Two algorithms from the Python PVAnalytics package were assessed, and one algorithm from the Solar-Data-Tools package was assessed. Each algorithm's ability to accurately detect and measure time shifts was assessed.

automated preprocessing↗

Summary of the the 11th Symposium of the International Society of Root Research

11th Symposium of the International Society of Root Research (ISRR11) and the 9th International Symposium on Root Development (Rooting2021) - Root Biology Never Sleeps virtual meeting May 24 - 28. These meetings are generally held in separate years. However, because of travel restrictions imposed by the COVID-19 pandemic, the organizing committees of both symposia decided to host the two meetings as a fully-joint and virtual-only conference. Various time zones were considered when developing the schedule, as live interactions was an important focus. Scientific sessions were held from 3 a.m. to 10 p.m. US Central Daylight Time (CDT) to meet the international demand. More than 700 participants from 52 countries virtually attend both events which featured 74 talks in 16 sessions including: 10 plenary lectures, 16 keynote speakers and 48 selected talks. Additionally, nearly 300 posters were presented in nine poster sessions. The meeting also featured an Ambassador Program with 21 ambassadors from 10 countries. These ambassadors organized a half-day pre-symposium workshop and produced a review of the meeting for “New Phytologist”. The meeting also awarded a Lifetime Award to Dr. Wendy Silk (Prof. Emerita University of California, Davis). Committee Members: • Bob Sharp (Chair) – University of Missouri • Felix Fritschi (Chair, Int’l Program Committee) – University of Missouri • David Braun – University of Missouri • Vicki Bryan – University of Missouri • Rich Ferrieri – University of Missouri • Laura Greeley – University of Missouri (postdoctoral representative) • Ali Housh – University of Missouri (graduate student representative) • Allison Miller – Donald Danforth Plant Science Center and St Louis University • Mel Oliver – University of Missouri • Jonathan Stemmle – University of Missouri • Gus Thies – University of Missouri & Donald Danforth Plant Science Center (graduate student representative) • Chris Topp - Donald Danforth Plant Science Center

Root Biology↗

Characterization of Coal Refuse Sites in West Virginia: Stream Loss, Volume Estimation, and Land Cover Analysis for Restoration Feasibility

Coal refuse disposal across Appalachia has resulted in widespread environmental degradation, including stream burial, landscape destabilization, and long-term hydrologic impacts. This study provides a GIS-based spatial characterization of 623 coal refuse sites in West Virginia, evaluating their potential for ecological and economic restoration. Stream loss was quantified through digitization of historic topographic maps, revealing over 194,500 meters of historically present streams lost, with 105,000 meters directly buried beneath refuse piles. Volume estimation using empirical Bayesian kriging and modern LiDAR surfaces indicated approximately 1.96 billion cubic meters of deposited refuse. Land cover analysis based on NAIP-derived classification showed that 48% of the total site area was forested, while 15% remained barren. These results highlight not only the environmental footprint of legacy refuse deposits but also their potential for restoration through stream daylighting and beneficial reuse. Emerging opportunities, including rare earth element recovery and mitigation banking, may offer economic incentives to facilitate reclamation. This work establishes a spatial framework to prioritize refuse sites for restoration, balancing ecological uplift with feasible material management strategies.

58 GEOSCIENCES↗

Simulation-based assessment of the energy savings benefits of integrated control in office buildings

The purpose of this study is to use existing simulation tools to quantify the energy savings benefits of integrated control in office buildings. An EnergyPlus medium office benchmark simulation model (V1.0_3.0) developed by the Department of Energy (DOE) was used as a baseline model for this study. The baseline model was modified to examine the energy savings benefits of three possible control strategies compared to a benchmark case across 16 DOE climate zones. Two controllable subsystems were examined: (1) dimming of electric lighting, and (2) controllable window transmission. Simulation cases were run in EnergyPlus V3.0.0 for building window-to-wall ratios (WWR) of 33percent and 66percent. All three strategies employed electric lighting dimming resulting in lighting energy savings in building perimeter zones ranging from 64percent to 84percent. Integrated control of electric lighting and window transmission resulted in heating, ventilation, and air conditioning (HVAC) energy savings ranging from ?1percent to 40percent. Control of electric lighting and window transmission with HVAC integration (seasonal schedule of window transmission control) resulted in HVAC energy savings ranging from 3percent to 43percent. HVAC energy savings decreased moving from warm climates to cold climates and increased when moving from humid, to dry, to marine climates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Chapter 9: 30 Years of Living in a Solar House in Colorado

Having met in 1980 while working at the National Renewable Energy Laboratory, we were inspired by the vision of a renewable energy future to raise our family in a passive solar home. A basic, factory-cut, trilevel house design was selected in 1985 and intentionally sited and modified according to passive solar design principles to optimize conservation and solar gain, with a plan to add photovoltaics as soon as feasible.

14 SOLAR ENERGY↗

Field validation of isotropic analytical models for simulating fabric shades

Fabric roller shades are common shading materials used in commercial and residential buildings. Accurately characterizing and modeling shades helps practitioners select the appropriate product and its control strategy based on climate and occupants' priorities, such as visual comfort and view to outdoors. Previous studies established a generalized method for modeling complex fenestration systems using data-driven tabulated bidirectional scattering distribution functions. However, deploying such a method at scale to all fabric shading products on the market is too costly and time-consuming. Analytical models that are based on a limited set of measurements (e.g., normal-normal and normal-hemispherical visible transmittance and reflectance, and directional cut-off angles) can be used to model the wide variety of shading products on the market. This study evaluates the performance of two isotropic analytical models, Roos-Wienold and Modified-Kotey, for modeling fabric roller shades, with a focus on the model's ability to predict occupant visual comfort. The performance evaluation was conducted through laboratory and field measurements and simulations. The results showed that both models are sufficient for predicting vertical illuminance at seated eye-level. Roos-Wienold model was able to predict binary visual comfort classification (glare/no-glare) under a wide range of luminance conditions, while Modified-Kotey model did not perform as well under high-contrast low-adaptation conditions. Both models are insufficient in predicting visual comfort at a four-point scale (e.g., imperceptible, perceptible, disturbing, intolerable). The two isotropic models become less accurate when the fabric exhibits high anisotropy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Splayed mirror light pipes

An expression is given for the transmission of the rectangular-section mirror light pipe. The expression is used to model throughputs for simulated solar conditions over a calender year. It is found that the splaying of a mirror light pipe results in a significant increase in throughputs particularly in winter months. (author)

14 SOLAR ENERGY↗