Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Reduced-Order Modeling Method for Phase-Change Thermal Energy Storage Heat Exchangers

Thermal energy storage can facilitate the effective utilization of renewable energy. To speed up the design process of thermal energy storage devices, it is critical to develop fast and accurate modeling methods for phase change material embedded heat exchangers (PCM HXs). This study developed and compared two approximation-assisted reduced-order PCM HX models for the simulation of thermal storage components and systems, which were verified against a validated finite-volume model. They are a pure black-box model, and a grey-box model based on the Number of Transfer Units (or effectiveness-NTU) approach. We used the reduced-order models to predict the performance of standalone PCM HX for 1000 cases with different fluid inlet conditions and HX designs. We also integrated the models with a vapor compression system to predict the compressor energy consumption and total charging time under various conditions. The results show that overall, the black-box model gave more accurate results than the grey-box model. On average, the mean absolute deviation in the PCM HX fluid outlet temperature was 0.05 K and 0.1 K for the black-box model and grey-box model, respectively. The grey-box model gave larger temperature deviation toward the end of the phase change process, due to the simplified two-node PCM representation. On the system level, the mean absolute deviation in compressor energy consumption was 0.2% and 0.3% for the black-box model and grey-box model, respectively. Their mean absolute deviation in total charging time was 1.1% and 2.6%, respectively. In terms of computation efficiency, the system simulation speedup ratio gained by using the reduced-order models was 11 to 57. System simulation time was decreased from an average of 1465 s to an average of 59 s. This shows that the proposed reduced-order modeling methods can be used to predict system performance of PCM HXs with less than 3% accuracy penalty, and 25 times less computational time than finite-volume models, enabling faster design and evaluation of PCM thermal storage devices.

25 ENERGY STORAGE↗

Can section 45Q tax credit foster decarbonization? A case study of geologic carbon storage at Acid Gas Injection wells in the Permian Basin

Carbon capture, utilization, and storage (CCUS) is an important pathway for meeting climate mitigation goals. While the economic viability of CCUS is well understood, previous studies do not evaluate the economic feasibility of carbon capture and storage (CCS) in the Permian Basin specifically regarding the new Section 45Q tax credits. We developed a technoeconomic analysis method, evaluated the economic feasibility of CCS at the acid gas injection (AGI) wells, and assessed the implication of Section 45Q tax credits for CCS at the AGIs. We find that the compressors, well depth, and the permit and monitoring costs drive the facility costs. Compressors are the predominant contributors to capital and operating expenditure driving the levelized cost of CO 2 storage. Strategic cost reduction measures identified include 1) sourcing of low-cost electricity and 2) optimizing operational efficiency in well operations. In evaluating the impact of the tax credits on CCS projects, facility scale proved decisive. We found that facilities with an annual injection rate exceeding 10,000 MT storage capacity demonstrate economic viability contingent upon the procurement of inputs at the least cost. The new construction of AGI wells were found to be economically viable at a storage capacity of 100,000 MT. The basin is heavily focused on CCUS (tax credit – $\$$65/MT CO 2 ), which overshadows CCS ($\$$85/MT CO 2 ) opportunities. Balancing the dual objectives of CCS and CCUS requires planning and coordination for optimal resource and pore space utilization to attain the basin's decarbonization potential. We also found that CCS on AGI is a lower cost CCS option as compared to CCS on other industries.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A data driven control strategy for optimal and flexible operation of absorption systems; Stratégie de régulation fondée sur les données pour un fonctionnement optimal et flexible des systèmes à absorption

A novel control strategy for vapor absorption systems with experimental validation is presented. Statistical methods are used to integrate a detailed thermodynamic model and system-specific characteristics into a model based control algorithm. This allows for continuously optimized operation as well as fast response to variations in operating conditions. Autonomous controller performance was tested experimentally for response to changes in heat sink and evaporator temperatures. Continuous turndown with fast response to capacity demand changes, in contrast to suboptimal on/off control, was demonstrated. The thermal compressor concept was employed to develop the variable speed thermal compressor module, with aspects specific to absorption heat pumps, also facilitating cross-applicability of vapor compression system control strategies. Our results of this study enable further development and optimization of absorption systems for a wide range of applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A review on nearly isothermal compression technology

Compressors can be described as the heart of a vapor compression refrigeration system, circulating the working fluid in the system. Significant benefits can be gained from improving its efficiency since energy consumption is responsible for almost the entire system's power input. An effort has been made to achieve isothermal compression through liquid refrigerant injection or inter-stage cooling in refrigeration systems. In recent years, much effort has been invested into isothermal compression technology for air compressors or compressed air energy storage systems with the rise of renewable energy. Here, this work has explored the advancements made in this area and categorized them to discuss the benefits, limitations, and tradeoffs. Evidently, increasing heat transfer area is a significant aid in improving heat transfer, resulting in better isothermal compression. However, liquid pistons open more avenues for this to be pursued, and therefore, are limited to air compression applications. In addition, water injection proved to be the most effective among the methods. Finally, there is a need for more experimental research on refrigeration applications and the field is still in its infancy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Functionalized silica aerogels for gas-phase purification, sensing, and catalysis: A review

Silica aerogels have a rich history and a unique, fascinating gas-phase chemistry that has lent them to many diverse applications. This review starts with a brief discussion of the fundamental issues driving the movement of gases in silica aerogels and then proceeds to provide an overview of the work that has been done with respect to the purification of gases, sensing of individual gases, and uses of silica aerogels as catalysts for gas-phase reactions. Salient features of the research behind these different applications are presented, and, where appropriate, critical aspects that affect the practical use of the aerogels are noted. Specific sections under the gas-purification category focus on the removal of airborne nanoparticles, carbon dioxide, volatile organic compounds, sulfur gases and radioactive iodine from gas streams. The use of silica aerogels as sensors for humidity, oxygen, hydrocarbons, volatile acids and bases, various non-ammoniacal nitrogen gases, and viral particles is discussed. With respect to catalysis, the demonstrated use of silica aerogels as supports for oxidation, Fischer-Tropsch, alkane isomerization, and hydrogenation reactions is reviewed, along with a section on untested catalytic formulations involving silica aerogels. A short section focuses on recent developments in thermomolecular Knudsen compressor pumps using silica aerogel membranes. The review continues with an overview of the production methods, locations of manufacturing facilities globally, and a brief discussion of the economics before concluding with a few remarks about the present and future trends revealed by the work presented.

gas catalysis↗

Generation of coherent X-ray radiation through modulation compression

In this paper, we propose a scheme to generate tunable coherent X-ray radiation for future light source applications. This scheme uses an energy chirped electron beam, a laser modulator, a laser chirper and two bunch compressors to generate a prebunched kilo-Ampere current electron beam from a few tens Ampere electron beam out of a linac. The initial modulation energy wavelength can be compressed by a factor of $1+h_b R_{56}^a$ in phase space, where $h_b$ is the energy bunch length chirp introduced by the laser chirper, $R_{56}^a$ is the momentum compaction factor of the first bunch compressor. As an illustration, we present an example to generate more than 400 MW, 170 attoseconds pulse, 1 nm coherent X-ray radiation using a 60 Ampere electron beam out of the linac and 200 nm laser seed. Both the final wavelength and the radiation pulse length in the proposed scheme are tunable by adjusting the compression factor and the laser parameters.

Instruments & Instrumentation↗

Understanding airflow pattern and temperature distribution in domestic refrigerators – A review analyzing recent developments and bridging knowledge gaps

Refrigerators have become an essential appliance in every household, and they consume approximately 30% of total electricity among other domestic appliances such as clothes washers, dryers, and air conditioners. With the refrigerator’s comparatively high energy consumption compared with other appliances, existing research has mainly focused on improving the energy efficiency of refrigerators by changing the design of the compressor, heat exchanger, refrigerant, and insulation. However, previous studies have paid very little attention to the research and development of the temperature distribution in the refrigerator, which is a key parameter in determining energy consumption and food safety. Therefore, this review aims to present an overview of recent design developments to improve the temperature distribution and air circulation in domestic refrigerators, including static refrigerators and no-frost refrigerators. Herein, this review article discusses the various operation and design factors that can affect the air circulation and temperature uniformity of the refrigerator, including shelf arrangement, the compressor on/off cycle, thermostat settings, evaporator design, ambient conditions, door opening frequency, and product loading temperatures. Additionally, this review provides a summary of the advanced vapor compression cycle based refrigerators that are expected to provide better energy efficiency and independent temperature control in freezer and refrigerator compartments. This review elaborates on the significance of improving the performance of the domestic refrigerator in terms of temperature distribution and air circulation.

42 ENGINEERING↗

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗

Steady-state off-design modeling of the supercritical carbon dioxide recompression cycle for concentrating solar power applications with two-tank sensible-heat storage

Concentrating solar power researchers are evaluating the potential of the supercritical carbon dioxide recompression cycle to improve the thermal efficiency and decrease the capital costs of next-generation systems. This analysis investigates the steady-state off-design performance of a recompression cycle integrated with two-tank sensible-heat thermal energy storage as the ambient temperature and heat-transfer fluid (HTF) inlet conditions to the cycle change. This paper presents off-design component models and then cycle convergence and control models to maximize net cycle power output while constraining the high-side pressure and air-cooler fan power to their respective design values and fixing the cycle HTF outlet temperature to its design value. Results show that inventory control and air-cooler fan power are important control parameters that can be optimized to maximize off-design power output as the ambient temperature and HTF mass flow rate diverge from design. The high-side pressure and fan power constraints cause the cycle net power to degrade when the ambient temperature is warmer than the design value, and this study calculates a maximum mass flow rate for hot days above which the cycle cannot achieve the design HTF outlet temperature. Finally, the analysis shows that optimizing compressor shaft speeds can improve cold-day performance by around 1.5 percentage points and part-load performance by up to 2.5 percentage points versus a baseline case with no active compressor control.

14 SOLAR ENERGY↗

Optimization of Operating Profit for the FEED of the PZAS Process for CO 2 Capture on a 460 MW NGCC

A rating model of PZAS (Piperazine with the Advanced Stripper) for a 460 MW natural gas combined cycle was developed from vendor-provided equipment performance data. Surrogate rating models were built and used to optimize variable profit of the system subject to natural gas and electricity price at a fixed value for CO 2 of $\$80$/tonne. Several process constraints were considered between ambient temperatures of 4.4 and 40.5 °C. Lower lean loading resulted in lower reboiler heat duty of about 2.2 GJ/tonne. Lean loading at 0.2 mol/equiv N was sufficient at an ambient temperature of 4.4 °C to maximize variable profit. Solvent precipitation was avoided even at low lean loading (0.18 mol/mol) in the absence of a trim cooler for the lean solvent between the absorber and the cold cross exchanger. Optimal CO 2 removal was always higher than the design case removal of 90% and achieved a peak of 93.6% for 4.4 ºC ambient temperature. Lean solvent rate was a significant driver of profitability. The maximum capacity of the compressor was a significant constraint on profitability. Increasing compressor capacity by 20–30% could increase variable profit by about 21% in the case of 0.18 lean loading at 4.4 °C ambient temperature. Furthermore, this increase in profit was lower at higher ambient temperature and higher lean loading. The breakeven gas price was $\$4.6$/MMBtu at high lean loading of 0.22 mol/mol. Below this value, profit was maximized by increasing the boiler heat rate. Above this value, profit could not be increased by burning additional natural gas, requiring a reduction in boiler heat rate and consequently, specific heat duty. At lower lean loading (0.2, 0.18 mol/mol), this transition in heat duty was not observed due to the lower heat duty. As the ambient temperature increased, a similar trend in heat duty was observed at 0.22 lean loading, but the transition to lower heat duty occurred earlier at $\$4$/MMBtu. This was because of the lower CO 2 production at higher ambient temperature, making the process unprofitable at a gas price higher than $\$3$/MMBtu unless the heat duty of the stripper and natural gas boiler is steeply decreased.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pd-Ru pair on Pt surface for promoting hydrogen oxidation and evolution in alkaline media

Hydrogen oxidation reaction in alkaline media is critical for alkaline fuel cells and electrochemical ammonia compressors. The slow hydrogen oxidation reaction in alkaline electrolytes requires large amounts of scarce and expensive platinum catalysts. While transition metal decoration can enhance Pt catalysts’ activity, it often reduces the electrochemical active surface area, limiting the improvement in Pt mass activity. Here, we enhance Pt catalysts’ activity without losing surface-active sites by using a Pd-Ru pair. Utilizing a mildly catalytic thermal pyrolysis approach, Pd-Ru pairs are decorated on Pt, confirmed by extended X-ray absorption fine structure and high-angle annular dark-field scanning transmission electron microscopy. Density functional theory and ab-initio molecular dynamics simulations indicate preferred Pd and Ru dopant adsorption. The Pd-Ru decorated Pt catalyst exhibits a mass-based exchange current density of 1557 ± 85 A g –1 metal for hydrogen oxidation reaction, demonstrating superior performance in an ammonia compressor.

25 ENERGY STORAGE↗

Compression of femtosecond ytterbium fibre laser pulses using nonlinear processes in silica fibre

The temporal compression of 100-fs nanojoule laser pulses using nonlinear processes in silica fibre has been studied by numerical simulation and experimentally. The simulation results demonstrate that, in the case of spectral broadening in a normal dispersion fibre, followed by the temporal compression of the pulse in a compressor with a negative second-order dispersion, up to 90 % of the compressed pulse energy can be concentrated in the main peak, whose duration is a factor of 8 shorter than the initial laser pulse duration. In our experiments, 100-fs ytterbium fibre laser pulses have been compressed to pulses with an ∼13-fs main peak accounting for 87 % of the compressed pulse energy. At an average ytterbium laser output power of 4.2 W, the average power at the compressor output has been 3.1 W. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integration of a new Cryogenic Liquefier into the IB-1 Cryogenic Test Facility

The increase over the last years of the testing activities related to quantum systems, SRF cavities for the PIP-II and the LCLS-II projects, as well as superconducting magnets for the HL-LHC project and Fusion research activities, has required the addition of a new Helium cryogenic plant into the existing IB-1 Industrial Cryogenic Test Facility. The new cryogenic plant is composed of a cryogenic liquefier (Cold Box) able to provide up to 340 L/h, a 4 kL Dewar and two Mycom ® compressors providing up to 120 g/s. AL-AT (Air Liquide Advanced Technologies) has taken part of this project by designing and manufacturing the cryogenic liquefier. This new cryogenic plant is connected through a cryogenic distribution system to a 10 kL Dewar, which is part of the existing cryogenic test facility, itself composed of another Cold Box and a Sullair ® compressor. The new cryogenic plant has two main operating modes: one allows to transfer liquid helium at 1.7 bar between the two Dewars, the other allows to transfer supercritical Helium at 2 bar or more between the new Cold Box and the 10 kL Dewar. The entire industrial cryogenic facility is handled by a common Inventory Control System, composed of three control valves, and 9 tanks giving a total buffer volume of more than 1000 m3. This paper presents the technical features of the new Helium cryogenic plant, as well as the main results of the liquefier commissioning phase and details of the helium transfer between the two Dewars, making the connection between the cryogenic plants at the IB-1 Industrial Cryogenic Test Facility.

43 PARTICLE ACCELERATORS↗

LCLS-II Helium Refrigeration System Commissioning Results

SLAC National Accelerator Laboratory has upgraded to LCLS-II, featuring a 4 GeV superconducting linear accelerator composed of 37 cryomodules and two large helium refrigeration systems with a cooling capacity of 4 kW at 2.0 K. The LCLS-II Helium Refrigeration System (HRS) consists of two compressor stations, each with a power of approximately 4.5 MW, two 4.5 K cold boxes, each with a power of 18 kW equivalent at 4.5 K, and two sets of cold compressors that can each produce a flow of 230 g/s at 31 mbar (2.0K). Performance tests of the HRS were meticulously planned and successfully carried out, with results demonstrating that it exceeded the process requirements for LCLS-II operations. This paper provides a detailed presentation of the LCLS-II HRS performance and the challenges encountered during the commissioning phase.

42 ENGINEERING↗

Commissioning plan for LCLS II 2 K cold box

Commissioning of the LCLS II cryogenic plant has been planned with respect to electrical and mechanical systems checkout, equipment cleanup, cool-down, and individual performance evaluation. This plant consists of warm and cold storage, helium compressors, 4.5 K and 2 K cold boxes, and all auxiliaries typical for helium refrigeration processes. The 2 K cold box, consisting of five cold compressors in series to produce the flow and pressures necessary for 2K operation, will be the last equipment installed and, along with an additional 10,000 L helium dewar, will allow the entire plant to be commissioned as a single entity. The pre-commissioning stages, commissioning plan for 2 K cold box without connecting to the LCLS II LINAC, additional test equipment needed to simulate the loads, all process studies and associated results are described herein.

36 MATERIALS SCIENCE↗

Microbunching Instability in a Chicane: Two-Dimensional Mean Field Treatment

We study the microbunching instability in a bunch compressor by a parallel code with some improved numerical algorithms. The two-dimensional charge/current distribution is represented by a Fourier series, with coefficients determined through Monte Carlo sampling over an ensemble of tracked points. This gives a globally smooth distribution with low noise. The field equations are solved accurately in the lab frame using retarded potentials and a novel choice of integration variables that eliminates singularities. We apply the scheme with parameters for the first bunch compressor system of FERMI{at}Elettra, with emphasis on the amplification of a perturbation at a particular wavelength. Gain curves agree with those of the linearized Vlasov model at long wavelengths, but show some deviation at the smallest wavelengths treated.

43 PARTICLE ACCELERATORS↗