Magnetic Measurements of $\mathrm{HL-LHC AUP}$ Cryo-Assemblies at Fermilab

LQXFA/B production series cryogenic assemblies are being built for the LHC upgrade by the HL-LHC Accelerator Upgrade Project (AUP). These contain a pair of MQXFA quadrupole magnets combined as a cold mass within a vacuum vessel, and are to be installed in the IR regions of the LHC. The LQXFA/B are being tested at 1.9 K to assess alignment and magnetic performance at Fermilab's horizontal test facility. The ~10 m long assembly must meet stringent specifications for quadrupole strength and harmonic field integrals determination, magnetic axis location, and for variations in axis position and local field profiles. A multi-probe, PCB-based rotating coil and a Single Stretched Wire system are employed for these measurements. To accurately determine rotating coil location and angles within the cold mass, a laser tracker is utilized to record multiple targets at one end of the probe. Here this paper describes the measurements, probes/equipment, and techniques used to perform the necessary characterization of the cold mass.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Status of the MQXFB Nb 3 Sn Quadrupoles for the HL-LHC

Here, the cold powering test of the first two prototypes of the MQXFB quadrupoles (MQXFBP1, now disassembled, and MQXFBP2), the Nb 3 Sn inner triplet magnets to be installed in the HL-LHC, has validated many features of the design, such as field quality and quench protection, but has found performance limitations. In fact, both magnets showed a similar phenomenology, characterized by reproducible quenches in the straight part inner layer pole turn, with absence of training and limiting the performance at 93% (MQXFBP1) and 98% (MQXFBP2) of the nominal current at 1.9 K, required for HL-LHC operation at 7 TeV. Microstructural inspections of the quenching section of the limiting coil in MQXFBP1 have identified fractured Nb 3 Sn sub-elements in strands located at one specific position of the inner layer pole turn, allowing to determine the precise origin of the performance limitation. In this paper we outline the strategy that has been defined to address the possible sources of performance limitation, namely coil manufacturing, magnet assembly and integration in the cold mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic System Preliminary Design for a 0.5m-Long, Conduction-Cooled Nb3Sn Undulator Magnet Prototype

There are several NbTi superconducting undulator (SCU) magnets currently in operation at the Advanced Photon Source (APS) at Argonne National Laboratory (ANL). The development on Nb3Sn-based superconducting undulator magnets at APS is underway due to the potential to further enhance the performance of the SCUs. Superconducting undulator magnets need to keep temperature gradients minimized in order to retain thermal and operating current margin. We have designed the thermal links for efficient heat conduction using 3D finite element analysis (FEA) simulation in COMSOL Multiphysics software, which was later used for the calculation of the temperature distribution across a 0.5 m long, conduction-cooled, Nb3Sn undulator magnet prototype that includes both conductive heat transfer and radiative heating components. We have modelled the evolution of the thermal properties of the magnet winding as well as other cold parts during cool-down from ambient temperature with the operation of a SHI RDK-415D cryocooler to examine the estimated time that is needed for the cooldown as well as the baseline temperature we could achieve. A key result was that a maximum coil delta T = 0.11 K along the designed thermal links and a temperature range of 3.42 K-3.53 K for the winding were predicted at steady state. A pair of G10 support rods for carrying the magnet as well as a pair of current leads made of metals were also designed and optimized for the testing system, targeting for an operation temperature of 4 K and a coil current of 950 A DC.

Zhang, Danlu↗

Computation of the Strain Induced Critical Current Reduction in the 16 T Nb 3 Sn Test Facility Dipole

A test facility dipole is being developed at LBNL, targeting a 16 T field in a 144 mm wide aperture. The magnet uses a block design, with two double-pancake coils. In order to minimize motion under the large Lorentz forces, the coils are preloaded against a thick aluminum shell and iron yoke using bladder and key technology. It is then crucial to verify that the performance of the magnet is not degraded due to strain induced on the Nb 3 Sn conductor during assembly, cool-down and powering. The critical current of extracted strands was measured in a varying background magnetic field and as a function of the applied longitudinal strain. Finite element analysis was used to extract the strain state inside the superconducting strands during magnet assembly and operation. This strain was then compared to the measurements to evaluate potential reversible and irreversible effects on the magnet performances. Here the results suggest that the magnet can reach 16 T with sufficient margin, with no irreversible degradation in the high field region.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design Study of a Superconducting Quadrupole Magnet System Sustainable Under Dark Current Heating in ILC Main Linac

The International Linear Collider (ILC) main linac comprises a series of 12 m-long cryomodules. The cryomodule contains eight 9-cell superconducting (SC) RF (SRF) cavities and an SC quadrupole magnet combined with dipole correctors to focus and steer electron and positron beams. The magnets are installed between the SRF cavity string and at the longitudinal center of a common cryomodule/cryostat. These magnets are conductively cooled by pure aluminum channels thermally connected to a 2 K two-phase helium pipe for cooling the SRF cavities. A recent study shows that field-emitted electrons, so-called “dark current” initiated in the SRF cavities, are transmitted through the SRF cavity string and reach the SC magnet. The energy is inevitably absorbed in the SC coil due to the magnetic field, resulting in risks of a quench caused by the coil heating. We are investigating alternate magnet designs by using Nb $_{3}$ Sn or $\text{MgB}_{2}$ SC and by adding the dark current absorber surrounding the beam-pipe to realize sustainable magnet operation under the dark current heating. We report the design study of the magnet system and interfaces to the cryomodule accommodating it with the SRF cavities.

43 PARTICLE ACCELERATORS↗

Application of Distributed Fiber Optic Strain Sensors to LMQXFA Cold Mass Welding

The future High Luminosity upgrade of the Large Hadron Collider (HL-LHC) at CERN will include the low-beta inner triplets (Q1, Q2a/b, Q3) for two LHC insertion regions. The Q1, Q3 components consist of eight 10 m-long LMQXFA cryo-assemblies fabricated by the HL-LHC Accelerator Upgrade Project. Each LMQXFA Cold mass contains two Nb 3 Sn magnets connected in series. A stainless-steel shell is welded around the two magnets before the insertion into the cryostat. There is a limit on how much coil preload increase induced by the shell welding is allowed. Distributed Rayleigh backscattering fiber optics sensors were used for the first time to obtain a strain map over a wide area of a Nb 3 Sn magnet cold mass shell. Finally, data were collected during welding of the first LMQXFA cold mass and the results confirm that the increase of the coil pole azimuthal pre-stress after welding do not exceed requirements.

43 PARTICLE ACCELERATORS↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ORBUMP Pulsed Dipole Magnet Design for Fermilab Booster

Fermilab initiated the accelerator magnet system upgrade project PIP-II for future neutrino experiments. Old ORBUMP pulsed dipoles should be replaced with new stronger magnets occupying the same space as old ones. Four of these magnets connected in series form dogleg type of proton beam orbit. The magnet field and 19 kA current pulse length are close to 1 ms. Old magnet cores were based on a ferrite material. For new magnets, a magnet gap field is above 0.4 T, which completely saturates ferrite material. So, for the magnet core, 0.127 mm thick laminations of low carbon steel with inorganic coating, as the magnet were placed in a vacuum box. There were investigated transient magnet parameters including skin effect in the iron core and in the single-turn copper coil. The integrated field homogeneity was improved by the copper coil shimming. Simulated by OPERA3D power losses were used for the thermal analysis by ANSYS code. The magnet performance is strongly coupled with the power source. The dynamic magnet inductance and resistance were included in the pulsed power source design. Finally, the paper presented the ORBUMP magnet system design.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design of B1pF-A Large Aperture Dipole Magnet for EIC

The design of interaction region (IR) magnets for the Electron Ion Collider (EIC), demands tight boundary conditions on the magnet design given by the high field requirements and the proximity of electron and hadron beams within a common yoke and resultant crosstalk. Here, this article discusses the electromagnetic design of the superconducting collared magnet B1pF. The magnet will be built as the prototype for several collared magnets (dipoles and quadrupoles) for the hadron beam in the forward direction of the IR. The magnet design is based on a single layer coil with an inner diameter of 300 mm over a slot length of 3 m. The magnet produces an integral field of 10.34 T.m at a current of 11.9 kA to produce a nominal field of about 3.96 T at its center. Given by the common Rutherford cable parameters, the magnet will be used as a baseline for optimization of all the collared magnets. The article further discusses yoke optimizations, quench analysis, coil end design and efforts on fine tuning of field quality.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of Rolling Reduction on Critical Current Density and Microstructure of Bi-2212 Wires

Bi-2212 Rutherford cables have been fabricated into flat racetrack coils and canted-cosine-theta dipole magnets. The performance gap between the magnets made with Rutherford cables and the “short-sample-limit” is about 30%. To better understand the influence of Rutherford cable processing on the strand performance, we studied three Bi-2212 wires with filament architectures of 37 × 18 and 55 × 18 and diameters of 0.8 and 1.0 mm. To simulate the deformation caused by cabling process, the three wires were rolled with thickness reductions ranging from 10% to 30%. The aspect ratios of rolled strands are between 1.29 and 2.05. The low aspect-ratio wire is also an interesting form for fabricating solenoid coils with higher packing density. The round and rolled strands were heat-treated under 50 bar and with maximum heat treatment temperatures of 885.5 °C and 890.5 °C. The rolling deformation reduced filament size uniformity, resulting in filament merging in fully heat-treated wires. It was found that rolling reduction reduced wire critical current density (JE) by 16 to 18%, but the JE decrease saturated at 15 to 20% of the thickness reduction. It is believed that the reduced JE results from the filament merging caused by rolling and non-uniform shrinking during overpressure heat treatment.

Bi-2212 wire↗

Design of B2PF: A Large Aperture Nb-Ti Dipole Magnet for the Electron-Ion Collider

Here, we present the initial design of the matching dipole B2PF, a large aperture cosine-theta magnet for the Electron-Ion Collider (EIC). First we share an optimized 2D magnet cross-section based on a double-layer design with Nb-Ti Rutherford cable. This cross-section is optimized to meet the required field quality in the 120 mm coil aperture both at the nominal operating current and considering iron saturation effects during the ramp. Next, we share a first design of the 3D coil ends optimized for windability, field quality, and minimizing the conductor peak field. Based on the resulting peak field, we evaluate the short-sample margin of the design for an operating target of 6.3 T dipole field at 1.9 K. Finally, we share an initial mechanical design study which utilizes a key-and-bladder support structure capable of adjusting magnet preload.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mechanical Design of the MARCO Solenoid Detector Magnet

MARCO is the superconducting solenoid for ePIC, the new particle physics detector of the upcoming Electron Ion Collider (EIC) at the Brookhaven National Laboratory (NY, USA). The magnet has a 2.84 m warm bore diameter and is 3.85 m long. This 15 tons magnet provides a 2.0 T central field at the interaction point with a nominal current of about 4 kA at 4.5 K. The coil is composed of 6 layers of copper stabilized NbTi Rutherford in channel conductor (RIC) and it is wound internally to the brass mandrel. Here, this paper presents the detailed mechanical design of the magnet, starting with the magnet description, the material properties and the acceptance criteria considered. Then, the coil pack properties homogenization process is described. Subsequently, the 2D and 3D calculation models and their assumptions are described. At last, the computational results for the cool down and the energization are discussed. Index Terms—Superconducting Detector Magnet, material properties, homogenization, detector, EIC.

Reymond, Hugo [Commissariat a l'Energie Atomique e↗

Testing of a 15 kA Superconducting Transformer

Here, the manufacturing of superconducting magnets for High Energy Physics (HEP) and Fusion Energy Sciences (FES) applications requires high-current conductors to generate stronger magnetic fields without increasing the inductance of the magnet. Increased inductance is undesirable due to the associated AC losses, which reduce the temperature margin; and the quench protection also becomes complicated. Testing high-current conductors with a direct current (DC) room temperature power supply is unfeasible for two primary reasons: 1) the limited capacity to supply large currents, and 2) the significant heat load losses at the current leads. A superconducting transformer offers a solution to both challenges. A 50-kA superconducting transformer is planned for manufacturing and commissioning at Brookhaven National Laboratory as part of its user facility upgrade. This transformer will facilitate the testing of superconducting cables, conductors, joints, and insert coils under high magnetic field conditions (10 T) and with currents up to 50-kA. To evaluate the manufacturing process and validate the theoretical models, the magnet division has developed and tested a 15-kA prototype transformer. A control loop has been implemented to ensure precise current delivery to the sample. This paper presents the coil design, manufacturing, and experimental results from the cold tests.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Double Aperture HTS Dipole Magnet Model for the Persistent Current Operation

Particle accelerators use many different types of magnets. There is an interest in replacing rather low-field conventional resistive magnets with high-temperature superconducting (HTS) magnets. The main goal is to reduce operational expenses, which is critical during the continuously increasing cost of electricity. At Fermilab, several HTS accelerator magnets were built and successfully tested. The paper described a variant of the double-aperture dipole magnet that could be suitable for future Lepton Colliders. A single short-circuited HTS coil of 3.8 kA generates a homogeneous magnetic field of 57 mT in both magnet gaps of 84 mm. The short model magnet was designed, built, and successfully tested at liquid nitrogen temperature. This magnet works in a persistent current mode, which provides additional cost savings when used in particle storage rings operated at a stable magnetic field. The results of design, fabrication, and tests are presented and discussed. The magnet demonstrated a high magnetic field stability in both apertures, efficiency of correction coils, and primary powering circuit.

Kashikhin, Vladimir [Fermilab] (ORCID:000000017249↗

Fabrication of 8-Strand Rutherford Cables Using Roped Strands Made from Ultrafine Wires

Conventional Rutherford cables are typically made from solid round wire. While multi-stage cables have been made elsewhere, the purpose was usually to achieve a higher strand count and therefore a higher current carrying capability. In this work, we attempt to use two-stage roped strands made from ultrafine wires to fabricate Rutherford cables. The ultimate goal of this work is to obtain a very flexible cable that can wind accelerator magnet coils with a very tight bend radius in both the “easy way” (along the broad face of the cable) and the “hard way” (along the edge of the cable) in the wind-and-react manner, or wind coils with a radius typically used today but in the react and-wind manner with a much reduced degradation in critical current. We report our experience fabricating such Rutherford cables at the Lawrence Berkeley National Laboratory, and the initial findings from the analysis of the experimental cables made. We will discuss how the conventional wisdom and some rules of thumb for making Rutherford cables are no longer applicable or relevant, and the new thinking required in designing these cables.

Pong, Ian↗

Inverse Biot–Savart Optimization for Superconducting Accelerator Magnets

Superconducting (SC) magnets for accelerator concepts are often synthesized by numerically optimizing magnetic field waveforms, a process that requires a subsequent solution of a constrained inverse problem to identify suitable SC magnet windings. When the desired field distribution is intuitive, the inverse process is facilitated by seeding preconceived coil distributions into design optimization methods for refinement. With more complex magnetic field distributions, an initial design may be unknown, and topology optimization tools are required to synthesize current distributions without a priori guidance from a subject matter expert. In this work, we develop a constrained inverse Biot-Savart topology optimization methodology that synthesizes optimal distributions of current density in racetrack-like SC coils. The problem structure is exploited through a computationally efficient quadratic programming formulation, and the method is applied to recently published magnetic field waveforms for a recirculating proton phase shifter, a proton therapy gantry, and dipole magnets with sharp field transitions. The method and results herein identify novel winding configurations that can help magnet designers bring accelerator concepts to fruition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetostrictive Ultrasonic Waveguide Transducer for In-Pile Thermometry

Real-time and reliable temperature measurement on nuclear fuels is crucial for the safe operation of existing pressurized-water reactors and future advanced nuclear reactors. Magnetostrictive materials deform when subjected to a magnetic field or exhibit magnetization variation when stressed. Here, based on these properties, this study prototyped an ultrasonic thermometer (UT) consisting of a magnetostrictive waveguide, a dc coil providing appropriate magnetic biasing, and an ac coil generating an acoustic impulse and detecting the resulting acoustic echoes. By tracking the time of flight between the excitation pulse and the echoes, the UT can potentially detect nuclear fuel cladding temperature from a long distance. In this study, magnetostrictive iron–gallium alloys, or Galfenol, were selected as the waveguide due to their large magnetostriction, superior temperature survivability, excellent radiation resilience, and high mechanical robustness. A multiphysics finite-element model considering electrical, magnetic, and mechanical dynamics in the magnetostrictive UT was then developed. The model exhibited an error of 0.24% in time-of-flight simulation and, therefore, enabled computer-aided design and guided signal processing. Between room temperature and 120 °C, the new Galfenol-based UT exhibits a linear sensitivity of 162.8×10 ₋6 °C ₋1 , which is 51.7% higher than a previous magnetostrictive UT based on iron–cobalt–vanadium alloys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toroidal Field Reversing Switch

A motor-driven, high-current switch is being designed by Stäubli Electrical Connectors in collaboration with Princeton Plasma Physics Laboratory to reverse the DIII-D Toroidal field coil current. The existing field reversing procedure requires approximately 4 h of labor performed between run days to reconfigure the bus work, thus requiring a separate run day to complete experimental scans with both field directions. This typically results in different wall conditions which complicate the results or make them invalid. The proposed switch will complete the reversal process in approximately 4-5 min, between shots, so that wall conditions are not a factor, and easily fits within the 10-12 min DIII-D shot cycle. The switch is a compact design fitting into a 157.5 × 41 cm envelope. The switch uses two copper pins that slide between Stäubli MULTILAM contacts. The switch is rated for total current of 180-kA dc for 10 s with a 12-min repetition rate; the maximum operating coil current is 124-kA dc. The switch diagnostics include: voltage drop, current monitor, thermal monitors, position sensors, and motor torque. Here, the switch is rated for 300 cycles per year, and 3000 cycles overall before contact replacement, with contact inspection yearly. The design details and operation of the switch are covered in this article.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗