Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Calorimeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Photoproduction of the b 1 (1235) Meson off the proton at E gamma = 6-12 GeV

The GlueX Experiment at Jefferson Lab directs a linearly polarized photon beam on a liquid hydrogen target surrounded by an almost hermetic detector. The experiment aims to study the meson spectrum in the light-quark sector and search for exotic spin-parity states predicted by lattice QCD calculations. The lightest exotic candidate is the π 1 meson, which is predicted to decay dominantly to b 1 π. In this thesis, we present efforts to characterize the ωπ 0 decay channel of the b 1 meson as precursor to an analysis of the sought-after π 1 exotic state. We present an introduction to the physics involved and an overview of the detector subsystems with a focus on the Barrel Calorimeter gain monitoring system, as part of the service work expected by the GlueX Collaboration. We discuss the data analysis method used and present two frameworks, for angular moments and partial waves analyses. Details of the simulation used to calculate the detector acceptance. A proof of concept partial wave analysis is presented along with experimental angular moments as first step to a full analysis of the angular distribution Our partial wave analysis indicates that both S- and D-waves are needed, in qualitative agreement with theoretical expectations. The cross-section of the omega π 0 channel is extracted to be of the scale of 1 μb in agreement with previous measurements. The differential cross-section indicates the presence of two production processes with p 1 = -5:24 ± 0:04 for 0:25 < -t < 0:95 GeV 2 ~c 2 and p 2 = -1:24 ± 0:05 for 0:95 < -t < 2:0 GeV 2 ~c 2 , which does not agree with results from previous experiments. The s-channel helicity conservation and helicity amplitudes of the b 1 meson are presented as additional experimental observables. Our results confirm that the b1 photoproduction process does not conserve s-channel helicity though they do not align with previous measurements. The helicity amplitude of the omega are extracted to be |F 1 | 2 = 0:3037 ± 0:0003 which does not agree with the expected value of a b 1 decay or results from a previous experiment. Future steps in all these analyses will be continued by a new graduate student in the group, culminating in a publication.

Foda, Ahmed↗

Qualification study of SiPMs on a large scale for the CMVD Experiment

A Cosmic Muon Veto (CMV) detector using extruded plastic scintillators is being designed around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai for the feasibility study of shallow depth underground experiments. The scintillation signals that are produced in the plastic due to muon trajectories are absorbed by wavelength shifting (WLS) fibres. The WLS fibres re-emit photons of longer wavelengths and propagate those to silicon photo-multipliers (SiPMs). The SiPMs detect these photons, producing electronic signals. The CMV detector will use more than 700 scintillators to cover the mini-ICAL detector and will require around 3000 SiPMs. The design goal for the cosmic muon veto efficiency of the CMV is >99.99%. Hence, every SiPM used in the detector needs to be tested and characterised to satisfy the design goal of CMV. A mass testing system was developed for the measurement of gain and choice of the overvoltage ($V_{ov}$) of each SiPMs using an LED driver. The $V_{ov}$ is obtained by studying the noise rate, the gain of the SiPM. This paper describes the experimental setup used to test the SiPMs characteristics along with detailed studies of those characteristics as a function of temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass testing of SiPMs for the CMVD at IICHEP

A Cosmic Muon Veto Detector (CMVD) is being built around the mini-Iron Calorimeter (mini-ICAL) detector at the transit campus of the India based Neutrino Observatory, Madurai. The CMV detector will be made using extruded plastic scintillators with embedded wavelength shifting (WLS) fibres which propagate re-emitted photons of longer wavelengths to silicon photo-multipliers (SiPMs). The SiPMs detect these scintillation photons, producing electronic signals. The design goal for the cosmic muon veto efficiency of the CMV is $>$99.99% and fake veto rate less than 10$^{-5}$. A testing system was developed, using an LED driver, to measure the noise rate and gain of each SiPM, and thus determine its overvoltage ($V_{ov}$). This paper describes the test results and the analysed characteristics of about 3.5k SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calorimetric Detection of Dark Matter

Dark matter direct detection experiments are designed to look for the scattering of dark matter particles that are assumed to move with virial velocities $\sim 10^{-3}$. At these velocities, the energy deposition in the detector is large enough to cause ionization/scintillation, forming the primary class of signatures looked for in such experiments. These experiments are blind to a large class of dark matter models where the dark matter has relatively large scattering cross-sections with the standard model, resulting in the dark matter undergoing multiple scattering with the atmosphere and the rock overburden, and thus slowing down considerably before arriving at underground detectors. We propose to search for these kinds of dark matter by looking for the anomalous heating of a well shielded and sensitive calorimeter. In this detector concept, the dark matter is thermalized with the rock overburden but is able to pierce through the thermal shields of the detector causing anomalous heating. Using the technologies under development for EDELWEISS and SuperCDMS, we estimate the sensitivity of such a calorimetric detector. In addition to models with large dark matter - standard model interactions, these detectors also have the ability to probe dark photon dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The MU2E Experiment at FERMILAB: R&D, Design and Status

The Mu2e Experiment at Fermilab 1) will search for coherent, neutrinoless conversion of negative muons into electrons in the field of an aluminum nucleus, µ - + N (A, Z) → e - + N (A, Z). This is an example of Charged Lepton Flavour Violation (CLFV) never observed experimentally. The dynamics of such a process is well modelled by a two-body decay, resulting in a mono-energetic electron with an energy slightly below the muon rest mass (~104.967 MeV). If no events are observed in three years of running, Mu2e will set an upper limit on the ratio between conversion and capture rate R µe ≤ 6 × 10 -17 (@ 90% C.L.). This will improve the current limit of a factor of 10 4 over previous experiments. The experiment complements and extends the current/planned searches (µ → eγdecay at MEG , mu3e) as well as the direct searches for new physics at the LHC. Indeed, such CLFV searches in the muon sector probe new physics at a mass scale inaccessible with direct searches at either present or planned high-energy colliders. To detect the muon conversion process, a very intense pulsed beam of negative muons is produced by means of a S-shape Superconducting Solenoid Magnet System that is organized into three subsystems: the Production Solenoid, the Transport Solenoid and the Detector Solenoid. The beam is stopped at 10 GHz on an Aluminum target inside the Detector Solenoid. The Mu2e detectors, also installed inside the Detector Solenoid, are a high-precision tracker made on ~20000 straw tubes, and a calorimeter composed of ~1500 pure CsI crystals organized in two disks and readout by two large area UV-extended Silicon Photomultipliers (SiPMs). The Detector Solenoid region is surrounded by a Cosmic Ray Veto based on scintillators readout by SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Latest results from the CUORE experiment

The CUORE experiment is searching for the neutrinoless double β decay of the 130Te using cryogenic calorimeters. The CUORE detector consists of 988 TeO2 crystals packed in 19 towers and placed in a cryogenic facility with a base temperature of 10 mK. Crystals are enriched in the isotope 130Te which is the candidate for the neutrinoless double β decay. It is taking data since 2017 at the Laboratori Nazionali del Gran Sasso in Italy. Such a long operation of a bolometric experiment in stable condition has no precedent: by reaching 1 tonne-year of exposure CUORE set a fundamental milestone for any future experiment using this technology. The CUORE collaboration investigated the neutrinoless double β decay of 130Te exploiting the updated 1 tonne-year of statistics, setting a limit of 2.2 × 1025 yr at the 90% of credibility interval on the half-life, with a median sensitivity of 2.8 × 1025 yr.

Adams, DQ↗

The Experimental Programs on Light Pseudoscalar Meson Decays

The decays of the low-lying pseudoscalar mesons (?0, ?, and ??) allow access to a plethora of physics probes, from measurements of fundamental properties of matter such as the up-down quark mass ratio, to studies of channels that access higher-order terms in Chiral Perturbation theory, to tests of fundamental symmetries and searches for signatures of physics beyond the Standard Model. Several experiments have studied pseudoscalar decays: these experiments include PrimEx in Hall B at Jefferson Lab, A2 at the MAMI electron accelerator facility, the KLOE-II experiment at the DA?NE ?-factory, WASA-at-COSY at the cooler synchrotron COSY storage ring, and BESIII at the Beijing charm factory. In Hall D at Jefferson Lab, PrimEx-eta uses the Primakoff process to measure the ? radiative width using the GlueX spectrometer. In the near future the Jefferson Lab Eta Factory (JEF) experiment will use the GlueX spectrometer with an upgraded forward calorimeter to study ?(?) decay channels with a focus on all-neutral final states. Finally, a proposal for a new experiment, ``Rare Eta Decays with a TPC for Optical Photons'' (REDTOP) utilizing a proton beam on fixed targets, is under development. Highlights from previous and ongoing experiments and plans for future experiments will be presented.

Taylor, Simon↗

Making Every Microgram Count: Nanocalorimetry for Nuclear and Ultra-Rare Materials

The thermal analysis of nuclear and ultra-rare materials plays an important role in nuclear energy, planetary, environmental, and technological settings. Heat effects associated with the sample temperature, heat capacity, phase transformation, radiation damage and crystallographic defects are some of the thermochemistry measurements made with conventional differential scanning calorimeters. However, the measurement capabilities of the of traditional DSCs are often restricted when studying limited ultra-rare accessory minerals or materials submitted to extreme conditions, such as radiation in the nuclear fuel cycle and high pressure. We investigate the usage of nanocalorimetry for the energetic analysis of nuclear or ultra-rare materials, such as irradiated materials and high-pressure phases, with an emphasis on radiation damage and heat capacity measurements. Examples of how nanocalorimetry has been previously used for phase transitions, melting, and nucleation in ultra-fast heating and cooling rates are presented. Finally, an outlook of the field and future work, including beneficial safety and environmental outcomes from the potential usage of nanocalorimetry, are shown.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Studying the hadron structure with PANDA and CLAS using machine learning techniques

The hadron spectroscopy and structure are currently very active fields of research to study the non-perturbative regime of quantum chronodynamics. The first one studies the complex structure of excited hadrons by looking at their decay products, while the latter uses lepton scattering on nucleons. Both methods require reconstruction algorithms with great efficiency and good particle identification and background rejection rates. This work aims to provide these by either improving the existing methods or developing new ones. The first part of this document presents a feasibility study of a predicted hybrid charmonium state for the PANDA experiment. Lattice QCD calculations predict the ground state hybrid charmonium to be a spin exotic with quantum numbers of JP C = 1?+ at a mass of around 4.3 GeV with a width to be around 20 MeV. A machine learning based data analysis scheme is proposed to further improve the signal efficiency and the background reduction, alongside with improvements of the analysis software (PandaRoot), that are vital for this study. These improvements include a reworked clustering algorithm for the electromagnetic calorimeter (EMC) and an optimized monte carlo matching for neutral particles. The second part of this document is about studying the proton structure. A multidimensional study of the structure function ratio Fsin(?)LU /FUU has been performed for K±, based on the measurement of beam-spin asymmetries. It uses the high statistics data recorded with the CLAS12 spectrometer at Jefferson Laboratory. Fsin(?)LU is a twist-3 quantity that provides information about the quark gluon correlations in the proton. This document will present for the first time a simultaneous analysis of two kaon channels over a large kinematic range of z, xB , PT and Q2 with virtualities Q2 ranging from 1 GeV2 up to 8 GeV2 using machine learning techniques for improved particle identification.

Kripko, Aron↗

Improving the NOvA 3-Flavour Neutrino Oscillation Analysis

NOvA is a long-baseline neutrino experiment studying neutrino oscillations, a quantum mechanical interference phenomena where the observed neutrino flavour differs from that measured earlier, stemming from neutrino mass and flavour states mixing. NOvA consists of two functionally identical tracking calorimeter detectors deployed in the Fermilab NuMI beam. Both detectors are placed 14.6 mrad off the beam axis to achieve a narrow energy peak at 1.8 GeV at an oscillation maximum. The NOvA 3-flavour oscillation analysis measures the neutrino oscillation parameters sin2θ23 and ∆m232 as well as sets limit to δCP , the octant of θ23 and the sign of ∆m32. The event selection for 3-flavour neutrino oscillation analysis ensures the maximum quantity of signal is made available and a minimal amount of background is present. The current disappearance analysis selection has an efficiency of 80% for selecting νμ CC events, and with some improvements additional events could be recovered into the analysis to improve the sensitivity to the aforementioned oscillation parameters. In an effort to recover the currently rejected signal event to the analysis, these events were trained in a classification neural network. The aim of the network was to divide the data into signal (νμ CC events) and background (NC and νe CC events). The highest performing network gave an additional figure of merit gain of 2.34 increasing the sensitivity by 4.3% in effective POT equal to 33 days of additional data taking. This was compared to changing the current particle identification event selection cuts, the best result out of the tested cut combinations gave an additional FOM of 3.36 equal to 3.7% increase in effective POT equivalent to 28 days of data taking.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Future Electron-Ion Collider

Generalized Parton Distributions include rich information and became a powerful tool for studying hadron structure. Deeply Virtual Compton Scattering is the golden channel to access GPDs. The development of high luminosity and high-acceptance detectors (Electron-Ion Collider) allows physicists to overcome the difficulty of DVCS measurements. The outstanding performance of the accelerator performs the eA collisions at the center of mass energy from 20 to 140 GeV, while the luminosity at the scale of 1034 cm?2s?1. The new type of high-density crystal, PWO-II, produced by CRYTUR in 2×2×20 cm3 will be utilized in the calorimeter. The transparency of PWO-II crystals is > 70% at 620 nm, > 60% at 420 nm, and >35% at 360 nm. The crystals also show good radiation hardness under 30 Gy radiation exposure. Ten PWO-II crystals have a uniform light yield at 30 p.e./MeV, providing sufficient light yield to reduce the fluctuation of the energy measurements. Near 3000 crystals were constructed inside the 12-sided polygon supporting structure in the simulation. The island clustering algorithm was used for reconstructed the energy. The energy resolution study by the particle gun shows the stochastic term and constant term are 1.8% and 1.2%, respectively. The spatial resolution of NEEMC varies from 5% to 15% of the crystal?s width depending on the particle?s incident angle. The pion rejection of NEEMC can reach 103 with electron efficiency > 85% when the particle?s energy is larger than 1GeV. The Pi0- identified efficiency study can be interpreted as finding the local maxima in the single cluster caused by two high energy close photons. The study results show that efficiency is nearly 100% for pi0 energy is smaller than 10 GeV, and efficiency drops to 30% with 20 GeV pi0. The new type of 3x3 pixelated AC-LGAD were wire bonded to ALTIROC for performance test. The cross-talk between the adjacent channels is about 20% for VPA and 10% for TZ. A series of the TDC characteristic measurements show that the jitter for both preamplifiers is about 20 ps, and the time-walk effect is mild for inject charge > 12 pF. Furthermore, the beta source radiation results quantify the sharing scale of the 3x3 pixels AC-LGAD (? 20%). The electronics simulation study results show no significant changes in the spatial resolution, whether ADC resolution is 8, 10, or 12 bits. The 8-bit ADC is decided to use in the EICROC as it has a smaller size and power consumption than the 10-bit and 12-bit ADC. The ECCE is one of the full detector proposals for EIC. The new type of DVCS generator, called TOPEG, is used to generate the high acceptance beam configurations of 18×110 GeV2 electron and 4He. The acceptance study shows a -1.8 < ? < -1.4 gap between the BEMC and EEMC. The 10?x,y geometry cut is applied on the Roman Pots, so the acceptance of Roman Pots quickly drops to 0% when the polar angle of the recoiled 4He < 2 mrad. This primary ECCE simulation study suggests extending the acceptance of BEMC longitudinally as the structure limits the radial size of EEMC. The acceptance of the Roman Pots is still challenging. In 2023, The overall design of ePIC was finalized by merging two full detector proposals (ECCE and ATHENA) after a series of intensive simulation studies.

Wang, Pu-Kai↗

Recent Progress in U-10Mo Mechanical and Thermophysical Property Characterization

Results are presented on the mechanical and thermophysical property characterization of U-10Mo as part of the MP-1 qualification campaign. The thermal diffusivity, specific heat and thermal conductivity of as fabricated U-10Mo fuel foils and plates were measured using the thermal conductivity microscope (TCM), differential scanning calorimeter (DSC) and laser flash analyzer (LFA) all of which located in a shielded glove box – thermal property cell (TPC). A novel inverse method based on finite element analysis was developed to evaluate the thermal diffusivity of composite/layered materials via the LFA technique such as the 5-lyered U-10Mo monolithic fuel mini-plates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent Progress in U-10Mo Mechanical and Thermophysical Property Characterization -- Poster

Results are presented on the mechanical and thermophysical property characterization of U-10Mo as part of the MP-1 qualification campaign. The thermal diffusivity, specific heat and thermal conductivity of as fabricated U-10Mo fuel foils and plates were measured using the thermal conductivity microscope (TCM), differential scanning calorimeter (DSC) and laser flash analyzer (LFA) all of which located in a shielded glove box – thermal property cell (TPC). A novel inverse method based on finite element analysis was developed to evaluate the thermal diffusivity of composite/layered materials via the LFA technique such as the 5-lyered U-10Mo monolithic fuel mini-plates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Detecting Neutrons in MicroBooNE

A significant challenge in measurements of neutrino oscillations is reconstructing the incoming neutrino energies. While modern fully-active tracking calorimeters such as liquid argon time projection chambers in principle allow the measurement of all final state particles above some detection threshold, undetected neutrons remain a considerable source of missing energy with little to no data constraining their production rates and kinematics. We present the first demonstration of tagging neutrino-induced neutrons in liquid argon time projection chambers using secondary protons emitted from neutron-argon interactions in the MicroBooNE detector. We describe the method developed to identify neutrino-induced neutrons and demonstrate its performance using neutrons produced in muon-neutrino charged current interactions. The method is validated using a small subset of MicroBooNE's total dataset. The selection yields a sample with $60\%$ of selected tracks corresponding to neutron-induced secondary protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SULI Project Report: Mu2e otsdaq Documentation and Analytics

This report outlines the history of the CLFV puzzle, gives an overview of the Mu2e Experiment, and details the results of the DOE (Department of Energy)-funded SULI (Science Undergraduate Laboratory Internship) research completed over the summer 2024 on site at Fermilab. The project focused on the otsdaq software responsible for data acquisition. The project included drafting updated documentation for new users, including new procedures relevant for the Alma- Linux 9 operating system update, and the UPS package managing system replacement with Spack (scientific software package manager). A new art module (ReadTriggerCounts) to track trigger rates was created, with compatibility to be displayed via a Grafana server. The author also assisted in calorimeter cable installation in the detector hall.

Saarinen, Talia↗

Latest Three-Flavor Neutrino Oscillation Results from NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. NOvA was designed primarily to constrain neutrino oscillation parameters by analyzing $\nu_\mu (\bar{\nu}_\mu)$ disappearance and $\nu_e (\bar{\nu}_e)$ appearance data at the far detector. The Neutrinos at Main Injector (NuMI) beamline at Fermilab provides a high purity beam of neutrinos and anti-neutrinos to the experiment. The NOvA experiments consists of two functionally identical, finely granulated liquid tracking calorimeters, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector, situated 100 meters underground and 1 kilometer from the beam source, detects the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and beam $\nu_e (\bar{\nu}_e)$ events. The far detector, located in Ash River, MN, USA, 810 kilometers from the beam source, records the un-oscillated $\nu_\mu (\bar{\nu}_\mu)$ and the oscillated $\nu_e (\bar{\nu}_e)$ events. The most recent measurements of three flavor neutrino oscillation parameters based on an analysis of the data collected from a neutrino-beam exposure of $26.60 \times 10^{20}$ POT and an anti-neutrino beam exposure of $12.50\times 10^{20}$ POT with an additional low energy $\nu_e$ sample, will be presented in this talk.

Singh, Ishwar↗

MAIA: A new detector concept for a 10 TeV muon collider

Muon colliders offer a compelling opportunity to explore the TeV scale and conduct precision tests of the Standard Model, all within a relatively compact geographical footprint. This paper introduces a new detector concept, MAIA (Muon Accelerator Instrumented Apparatus), optimized for $\sqrt{s}=10$ TeV $\mu\mu$ collisions. The detector features an all-silicon tracker immersed in a 5T solenoid field. High-granularity silicon-tungsten and iron-scintillator calorimeters surrounding the solenoid capture high-energy electronic and hadronic showers, respectively, and support particle-flow reconstruction. The outermost subsystem comprises an air-gap muon spectrometer, which enables standalone track reconstruction for high-momentum muons. The performance of the MAIA detector is evaluated in terms of differential particle reconstruction efficiencies and resolutions. Beam-induced background (BIB) simulations generated in FLUKA are overlaid with single particle gun samples to assess detector reconstruction capabilities under realistic experimental conditions. Even with BIB, reconstruction efficiencies exceed 95% for energetic tracks, photons, and neutrons in the central region of the detector. This paper outlines promising avenues of future work, including forward region optimization and opportunities for enhanced flavor/boosted object tagging, and addresses the technological assumptions needed to achieve the desired detector performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗