Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COUNTING RATES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Performances of a bent-crystal spectrometer adapted to resonant x-ray emission measurements on gas-phase samples

We describe a bent-crystal spectrometer adapted to measure x-ray emission resulting from core-level excitation of gas-phase molecules in the 0.8-8 keV energy range. The spectrometer is based on the Johann principle, and uses a microfocused photon beam to provide high-resolution (resolving power of {approx}7500). A gas cell was designed to hold a high-pressure (300 mbar) sample of gas while maintaining a high vacuum (10{sup -9} mbar) in the chamber. The cell was designed to optimize the counting rate (2000 cts/s at the maximum of the Cl K{alpha} emission line), while minimizing self-absorption. Example of the K{alpha} emission lines of CH{sub 3}Cl molecules is presented to illustrate the capabilities of this new instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-Ray Measurements Of A Thermo Scientific P385 DD Neutron Generator

Idaho National Laboratory is experimenting with electrical neutron generators, as potential replacements for californium-252 radioisotopic neutron sources in its PINS prompt gamma-ray neutron activation analysis (PGNAA) system for the identification of military chemical warfare agents and explosives. In addition to neutron output, we have recently measured the x-ray output of the Thermo Scientific P385 deuterium-deuterium neutron generator. X rays are a normal byproduct from neutron generators, but depending on their intensity and energy, x rays can interfere with gamma rays from the object under test, increase gamma-spectrometer dead time, and reduce PGNAA system throughput. The P385 x-ray energy spectrum was measured with a high-purity germanium (HPGe) detector, and a broad peak is evident at about 70 keV. To identify the source of the x rays within the neutron generator assembly, it was scanned by collimated scintillation detectors along its long axis. At the strongest x-ray emission points, the generator also was rotated 60 deg. between measurements. The scans show the primary source of x-ray emission from the P385 neutron generator is an area 60 mm from the neutron production target, in the vicinity of the ion source. Rotation of the neutron generator did not significantly alter the x-ray count rate, and its x-ray emission appears to be axially symmetric. A thin lead shield, 3.2 mm (1/8 inch) thick, reduced the 70-keV generator x rays to negligible levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SWIFT X-RAY AND ULTRAVIOLET MONITORING OF THE CLASSICAL NOVA V458 VUL (NOVA VUL 2007)

We describe the highly variable X-ray and UV emission of V458 Vul (Nova Vul 2007), observed by Swift between 1 and 422 days after outburst. Initially bright only in the UV, V458 Vul became a variable hard X-ray source due to optically thin thermal emission at kT = 0.64 keV with an X-ray band unabsorbed luminosity of 2.3 x 10{sup 34} erg s{sup -1} during days 71-140. The X-ray spectrum at this time requires a low Fe abundance (0.2{sup +0.3} {sub -0.1} solar), consistent with a Suzaku measurement around the same time. On day 315 we find a new X-ray spectral component which can be described by a blackbody with temperature of kT = 23{sup +9} {sub -5} eV, while the previous hard X-ray component has declined by a factor of 3.8. The spectrum of this soft X-ray component resembles those typically seen in the class of supersoft sources (SSS) which suggests that the nova ejecta were starting to clear and/or that the white dwarf photosphere is shrinking to the point at which its thermal emission reaches into the X-ray band. We find a high degree of variability in the soft component with a flare rising by an order of magnitude in count rate in 0.2 days. In the following observations on days 342.4-383.6, the soft component was not seen, only to emerge again on day 397. The hard component continued to evolve, and we found an anticorrelation between the hard X-ray emission and the UV emission, yielding a Spearman rank probability of 97%. After day 397, the hard component was still present, was variable, and continued to fade at an extremely slow rate but could not be analyzed owing to pile-up contamination from the bright SSS component.

79 ASTRONOMY AND ASTROPHYSICS↗

Report of tritide study at the Responsive Neutron Generator Product Deployment Center.

This report documents a study of sample counting results for wipes from routine surface area monitoring conducted at the Responsive Neutron Generator Product Deployment Center (RNGPDC) at Sandia National Laboratories (SNL). The study was initiated in November 2006, with two samples suspected of containing erbium tritide, after some samples were found to exhibit higher tritium counting rates upon recount at a later time. The main goal of the study was to determine whether the current practice of analyzing tritium wipe samples once, within a few days of sample collection, is adequate to accurately quantify the amount of tritium on the sample when tritides may be present. Recommendations are made toward routine recounting of vials suspected of containing particulate forms of tritium.

61 RADIATION PROTECTION AND DOSIMETRY↗

INTERPRETING FLUX FROM BROADBAND PHOTOMETRY

We discuss the transformation of observed photometry into flux for the creation of spectral energy distributions (SED) and the computation of bolometric luminosities. We do this in the context of supernova studies, particularly as observed with the Swift spacecraft, but the concepts and techniques should be applicable to many other types of sources and wavelength regimes. Traditional methods of converting observed magnitudes to flux densities are not very accurate when applied to UV photometry. Common methods for extinction and the integration of pseudo-bolometric fluxes can also lead to inaccurate results. The sources of inaccuracy, though, also apply to other wavelengths. Because of the complicated nature of translating broadband photometry into monochromatic flux densities, comparison between observed photometry and a spectroscopic model is best done by forward modeling the spectrum into the count rates or magnitudes of the observations. We recommend that integrated flux measurements be made using a spectrum or SED which is consistent with the multi-band photometry rather than converting individual photometric measurements to flux densities, linearly interpolating between the points, and integrating. We also highlight some specific areas where the UV flux can be mischaracterized.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary Results from Nuclear Decay Experiments Performed During the Solar Eclipse of August 1, 2008

Recent developments in efforts to determine the cause of anomalous experimental nuclear decay fluctuations suggest a possible solar influence. Here we report on the preliminary results from several nuclear decay experiments performed at Thule Air Base in Greenland during the Solar Eclipse that took place on 1 August 2008. Because of the high northern latitude and time of year, the Sun never set and thereby provided relatively stabilized conditions for nearly all environmental factors. An exhaustive list of relevant factors were monitored during the eclipse to help rule out possible systematic effects due to external influences. In addition to the normal temperature, pressure, humidity, and cloud cover associated with the outside ambient observations, we included similar measurements within the laboratory along with monitoring of the power supply output, local neutron count rates, and the Earth's local magnetic and electric fields.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quasi-periodic oscillations in short recurring bursts of magnetars SGR 1806–20 and SGR 1900+14 observed with RXTE

Quasi-periodic oscillations (QPOs) observed in the giant flares of magnetars are of particular interest due to their potential to open up a window into the neutron star interior via neutron star asteroseismology. However, only three giant flares have been observed. We therefore make use of the much larger data set of shorter, less energetic recurrent bursts. Here, we report on a search for QPOs in a large data set of bursts from the two most burst-active magnetars, SGR 1806-20 and SGR 1900+14, observed with Rossi X-ray Timing Explorer. We find a single detection in an averaged periodogram comprising 30 bursts from SGR 1806–20, with a frequency of 57 Hz and a width of 5 Hz, remarkably similar to a giant flare QPO observed from SGR 1900+14. This QPO fits naturally within the framework of global magneto-elastic torsional oscillations employed to explain giant flare QPOs. Additionally, we uncover a limit on the applicability of Fourier analysis for light curves with low background count rates and strong variability on short timescales. In this regime, standard Fourier methodology and more sophisticated Fourier analyses fail in equal parts by yielding an unacceptably large number of false-positive detections. This problem is not straightforward to solve in the Fourier domain. Instead, we show how simulations of light curves can offer a viable solution for QPO searches in these light curves.

79 ASTRONOMY AND ASTROPHYSICS↗

Artificial Neural Networks in Spectrometry and Neutron Dosimetry

The ANN technology has been applied to unfold the neutron spectra of three neutron sources and to estimate their dosimetric features. To compare these results, neutron spectra were also unfolded with the BUNKIUT code. Both unfolding procedures were carried out using the count rates of a Bonner sphere spectrometer. The spectra unfolded with ANN result similar to those unfolded with the BUNKIUT code. The H*(10) values obtained with ANN agrees well with H*(10) values calculated with the BUNKIUT code.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHARACTERIZING INTERMITTENCY OF 4-Hz QUASI-PERIODIC OSCILLATION IN XTE J1550–564 USING HILBERT–HUANG TRANSFORM

We present time-frequency analysis results based on the Hilbert–Huang transform (HHT) for the evolution of a 4-Hz low-frequency quasi-periodic oscillation (LFQPO) around the black hole X-ray binary XTE J1550–564. The origin of LFQPOs is still debated. To understand the cause of the peak broadening, we utilized a recently developed time-frequency analysis, HHT, for tracking the evolution of the 4-Hz LFQPO from XTE J1550–564. By adaptively decomposing the ∼4-Hz oscillatory component from the light curve and acquiring its instantaneous frequency, the Hilbert spectrum illustrates that the LFQPO is composed of a series of intermittent oscillations appearing occasionally between 3 and 5 Hz. We further characterized this intermittency by computing the confidence limits of the instantaneous amplitudes of the intermittent oscillations, and constructed both the distributions of the QPO’s high- and low-amplitude durations, which are the time intervals with and without significant ∼4-Hz oscillations, respectively. The mean high-amplitude duration is 1.45 s and 90% of the oscillation segments have lifetimes below 3.1 s. The mean low-amplitude duration is 0.42 s and 90% of these segments are shorter than 0.73 s. In addition, these intermittent oscillations exhibit a correlation between the oscillation’s rms amplitude and mean count rate. This correlation could be analogous to the linear rms-flux relation found in the 4-Hz LFQPO through Fourier analysis. We conclude that the LFQPO peak in the power spectrum is broadened owing to intermittent oscillations with varying frequencies, which could be explained by using the Lense–Thirring precession model.

79 ASTRONOMY AND ASTROPHYSICS↗

Final State Interactions in GENIE

Final state interactions (FSI) are an important part of all neutrino event generators because modern detectors are made of nuclei to maximize count rate. The incident neutrino will interact with one (or two) nucleons but the final state can be quite different because the hadrons will have further interactions in the residual nucleus. This has historically been one of the major differences between event generators. GENIE will now have 2 FSI codes which allow interesting comparisons for the first time.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An inductively heated hot cavity catcher laser ion source

An inductively heated hot cavity catcher has been constructed for the production of low-energy ion beams of exotic, neutron-deficient Ag isotopes. A proof-of-principle experiment has been realized by implanting primary {sup 107}Ag{sup 21+} ions from a heavy-ion cyclotron into a graphite catcher. A variable-thickness nickel foil was used to degrade the energy of the primary beam in order to mimic the implantation depth expected from the heavy-ion fusion-evaporation recoils of N = Z {sup 94}Ag. Following implantation, the silver atoms diffused out of the graphite and effused into the catcher cavity and transfer tube, where they were resonantly laser ionized using a three-step excitation and ionization scheme. Following mass separation, the ions were identified by scanning the frequency of the first resonant excitation step while recording the ion count rate. Ion release time profiles were measured for different implantation depths and cavity temperatures with the mean delay time varying from 10 to 600 ms. In addition, the diffusion coefficients for silver in graphite were measured for temperatures of 1470 K, 1630 K, and 1720 K, from which an activation energy of 3.2 ± 0.3 eV could be determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A setup for resonant inelastic soft x-ray scattering on liquids at free electron laser light sources

We present a flexible and compact experimental setup that combines an in vacuum liquid jet with an x-ray emission spectrometer to enable static and femtosecond time-resolved resonant inelastic soft x-ray scattering (RIXS) measurements from liquids at free electron laser (FEL) light sources. We demonstrate the feasibility of this type of experiments with the measurements performed at the Linac Coherent Light Source FEL facility. At the FEL we observed changes in the RIXS spectra at high peak fluences which currently sets a limit to maximum attainable count rate at FELs. The setup presented here opens up new possibilities to study the structure and dynamics in liquids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects of using rare-earth hexaborides in thermoelectric single-photon detectors

The results of the numerical simulation of heat propagation processes occurring after the absorption of single photons with energies of 1 eV–1 keV in a three-layer sensor of a thermoelectric detector are analyzed. Different configurations of the sensor with a tungsten absorber, a thermoelectric layer of cerium hexaboride, and a tungsten heat sink are considered. It is shown that sensors for detecting photons of a specific spectral range with the required energy resolution and counting rate can be developed by varying the geometric sizes of the sensor layers. It is concluded that a three-layer sensor has a number of advantages in comparison with a single-layer sensor and has characteristics allowing consideration of the thermoelectric detector as a realistic alternative to superconducting single-photon detectors.

36 MATERIALS SCIENCE↗

Superconducting nanowire single photon detectors fabricated from an amorphous Mo{sub 0.75}Ge{sub 0.25} thin film

We present the characteristics of superconducting nanowire single photon detectors (SNSPDs) fabricated from amorphous Mo{sub 0.75}Ge{sub 0.25} thin-films. Fabricated devices show a saturation of the internal detection efficiency at temperatures below 1 K, with system dark count rates below 500 cps. Operation in a closed-cycle cryocooler at 2.5 K is possible with system detection efficiencies exceeding 20% for SNSPDs which have not been optimized for high detection efficiency. Jitter is observed to vary between 69 ps at 250 mK and 187 ps at 2.5 K using room temperature amplifiers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Solution of Heliospheric Propagation: Unveiling the Local Interstellar Spectra of Cosmic-ray Species

Local interstellar spectra (LIS) for protons, helium, and antiprotons are built using the most recent experimental results combined with state-of-the-art models for propagation in the Galaxy and heliosphere. Two propagation packages, GALPROP and HelMod, are combined to provide a single framework that is run to reproduce direct measurements of cosmic-ray (CR) species at different modulation levels and at both polarities of the solar magnetic field. To do so in a self-consistent way, an iterative procedure was developed, where the GALPROP LIS output is fed into HelMod, providing modulated spectra for specific time periods of selected experiments to compare with the data; the HelMod parameter optimization is performed at this stage and looped back to adjust the LIS using the new GALPROP run. The parameters were tuned with the maximum likelihood procedure using an extensive data set of proton spectra from 1997 to 2015. The proposed LIS accommodate both the low-energy interstellar CR spectra measured by Voyager 1 and the high-energy observations by BESS, Pamela, AMS-01, and AMS-02 made from the balloons and near-Earth payloads; it also accounts for Ulysses counting rate features measured out of the ecliptic plane. The found solution is in a good agreement with proton, helium, and antiproton data by AMS-02, BESS, and PAMELA in the whole energy range.

79 ASTRONOMY AND ASTROPHYSICS↗

NATALIE: A 32 detector integrated acquisition system to characterize laser produced energetic particles with nuclear techniques

We present a stand-alone system to characterize the high-energy particles emitted in the interaction of ultrahigh intensity laser pulses with matter. According to the laser and target characteristics, electrons or protons are produced with energies higher than a few mega electron volts. Selected material samples can, therefore, be activated via nuclear reactions. A multidetector, named NATALIE, has been developed to count the {beta}{sup +} activity of these irradiated samples. The coincidence technique used, designed in an integrated system, results in very low background in the data, which is required for low activity measurements. It, therefore, allows a good precision on the nuclear activation yields of the produced radionuclides. The system allows high counting rates and online correction of the dead time. It also provides, online, a quick control of the experiment. Geant4 simulations are used at different steps of the data analysis to deduce, from the measured activities, the energy and angular distributions of the laser-induced particle beams. Two applications are presented to illustrate the characterization of electrons and protons.

43 PARTICLE ACCELERATORS↗

Wide dynamic range neutron flux monitor having fast time response for the Large Helical Device

A fast time response, wide dynamic range neutron flux monitor has been developed toward the LHD deuterium operation by using leading-edge signal processing technologies providing maximum counting rate up to ∼5 × 10{sup 9} counts/s. Because a maximum total neutron emission rate over 1 × 10{sup 16} n/s is predicted in neutral beam-heated LHD plasmas, fast response and wide dynamic range capabilities of the system are essential. Preliminary tests have demonstrated successful performance as a wide dynamic range monitor along the design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FIRST EVIDENCE FOR SPECTRAL STATE TRANSITIONS IN THE ESO 243-49 HYPERLUMINOUS X-RAY SOURCE HLX-1

The brightest ultra-luminous X-ray source, ESO 243-49 HLX-1, with a 0.2-10 keV X-ray luminosity of up to 10{sup 42} erg s{sup -1}, provides the strongest evidence to date for the existence of intermediate mass black holes (BHs). Although small-scale X-ray spectral variability has already been demonstrated, we have initiated a monitoring campaign with the X-ray Telescope (XRT) onboard the Swift satellite to search for luminosity-related spectral changes and to compare its behavior with the better-studied stellar mass BHs. In this Letter, we report a drop in the XRT count rate by a factor of approx8 which occurred simultaneously with a hardening of the X-ray spectrum. A second observation found that the source had re-brightened by a factor of approx21 which occurred simultaneously with a softening of the X-ray spectrum. This may be the first evidence for a transition between the low/hard and high/soft states.

79 ASTRONOMY AND ASTROPHYSICS↗