Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONGESTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Commuter Assistance Program Administrative Operating Procedure

Sandia National Laboratories/New Mexico’s (SNL/NM) Commuter Assistance Program (CAP) offers commuting alternatives to driving a single-occupant vehicle (SOV) to members of the workforce (MOW). The goal of this program is to reduce SOV use for commuting to and from SNL/NM, provide MOW opportunities to reduce their transportation costs, reduce greenhouse gas emissions, and reduce parking congestion at SNL/NM. The CAP advocates alternative transportation strategies such as carpooling, vanpooling, bicycling, and using public transportation. The Commuter Assistance Program website is the portal for MOW to access information about the different commuting alternatives available. Additionally, the website provides information on the City of Albuquerque’s Park and Ride program, traffic conditions, and the City of Albuquerque’s Guaranteed Ride Home.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Models and Strategies for Optimal Demand Side Management in the Chemical Industries

Deregulation and the increase of renewable electricity generation from wind and solar photovoltaics have transformed the U.S. electricity market. Economic and environmental benefits notwithstanding, the presence of renewables has increased variability and uncertainty on the supply side of the grid. Managing demand, rather than generation – a strategy referred to as “demand response (DR)” – is an attractive approach for mitigating this imbalance. DR efforts aim to reduce electricity usage during peak demand times, lessening stress on the grid. Industrial users are particularly attractive entities for DR participation since they present large, localized loads that can provide significant relief on grid demand and –unlike other large loads, such as buildings – are minimally dependent on human needs and preferences. In this project, we accomplished three main objectives. (1) We developed data-driven low-order DR scheduling-relevant dynamic models of chemical processes. Concurrently, we studied the formulation and solution of the associated optimal DR production scheduling problems. (a) A prototype air separation unit (ASU) model was used to generate simulated operating data for initial modeling efforts, which enabled the later use of industrial data for data-driven modeling. (b) We utilized Hammerstein-Wiener (HW) and Finite Step Response (FSR) models to represent nonlinear plant dynamics. (c) The HW models were linearized using exact linearization so they could potentially be embedded in power system models, which are formulated as mixed integer linear programs (MILPs). (d) We solved DR optimization problems under uncertainty and found that even naïve predictions of electricity price and product demand led to significant cost savings benefits. (2) Our DR scheduling optimization problem formulations are amenable to real-time solution. (a) We utilized Lagrangian Relaxation (LR) to efficiently solve the optimization problem by decoupling subproblems linked by complicating constraints. (b) We have achieved computation times for the 3-day DR scheduling problem of an ASU as low as 1.88 minutes. (3) Our representations of the DR behavior of chemical process as grid-level batteries were embedded in power system models. (a) For a small-scale grid, we found that incorporating the dynamics of the chemical plant in the optimal power flow calculations resulted in better resource management leading to up to 15% and 46% cost reduction for the grid and chemical plant operations, respectively, during periods of power line congestion. We have published several works dedicated to modeling and solving DR optimization problems from the user side. These were published in top peer-reviewed journals and are summarized in this report. The most recent work (and papers in preparation) considers DR scheduling from the grid side. Future efforts will consider networked plants (e.g., air separation units operating on a common pipeline) for DR participation, which is expected to amplify the capabilities of industrial DR participants to perform load-shifting. Our consideration of uncertainty in DR has inspired future directions in this area as well: we plan to develop multistage methods to fully account for the effects of uncertainty in DR scheduling.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grey Zone Test Range Social Model

The Grey Zone Test Range (GZTR) social model operates as a piece of the overall GZTR modeling effort. It works in conjunction with supply models for resources, an electric grid model for power availability, and a traffic model for road congestion, as well as a general controller framework that allows external system effects. The social model functions as an aggregate model where the entire population of the city is divided into groups based on the Transportation Analysis Zones (TAZs), a common geospatial boundary present in all GZTR models. These groups will act as a singular community; each time step the state of the system around them will be assessed and then community will come up with a general plan of action that they will attempt to follow for the day. Additionally, they will track values for their general emotional state and memory about negative impacts in the near past.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Near-Term Reliability and Resilience (NTRR) (Final Report)

The Near-Term Reliability and Resiliency (NTRR) was awarded in December 2020 as an inter-lab project to examine the reliability and resilience of the electricity grid and natural gas transportation availability. The project builds on studies conducted by The North American Electric Reliability Corporation (NERC), the U.S. Department of Energy (DOE), and other non-governmental research and operational focused on reliability and resilience analyses challenges. The research was conceived to address near-term scenarios (within 10 years), when many local and regional policy transitions could begin to impact grid reliability, resilience, and supporting infrastructure availability. To integrate the natural gas interdependency, the team began with the generating capacity and demand projections from the 2020 NERC Long-Term Reliability Assessment and the Bulk Electric System (BES) transmission topologies defined in the Western Electricity Coordinating Council (WECC) Anchor Data Set, Eastern Interconnection Reliability Assessment Group Multi-Regional Modeling Working Group (ERAG/MMWG) Data Set, the team calculated baseline regional power sector gas demands from present electricity delivery year through the end of delivery year 2030/31 by applying security constrained economic dispatch. This demand was compiled along with demand projections for regional residential, commercial, and industrial natural gas demands from the most recent Energy Information Administration (EIA) Annual Energy Outlook Reference Case into Deloitte’s MarketBuilder® North American Gas Model. Through the application of these demands, MarketBuilder® was projected the topology of natural gas flows in the natural gas pipeline network across the interconnected North American system along with regional natural gas prices that may be seen by market participants in future years Additionally, contingencies and sensitivities focused on the built models of the Eastern Interconnection (EI) and Western Interconnection (WI). They address challenges from the following with the outcomes being an identification of performance under the extreme conditions and an identification of potential grid weaknesses that should be addressed to mitigate the reduced performance and improve the resilience and reliability of the specific regions as well as the National Grid: • Weather events including extreme heat, extreme cold, high wind, no wind, wind and solar forecasting errors, and wildfires. • Gas availability, factoring in supply disruption (contractual and physical), seasonal availability constraints, and infrastructure limitations; and • Transmission availability and congestion.

03 NATURAL GAS↗

Effects of the State of Network on PTP accuracy – An ESnet Case Study

This report presents some of the effects and observations of the "state of network" on Precision Time Protocol (PTP) accuracy. "State of network" here refers to things like traffic on the network, network congestion, network routes, differences in paths taken in communication between two entities, etc. The network under consideration is ESnet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proxy Applications for Converged Workloads: DMC LDRD Initiative

Modern scientific applications are complicated and require coordination of several components. Proxy application driven software-hardware co-design plays a vital role in driving innovation among the developments of applications, software infrastructure and hardware architecture. Proxy applications are self-contained and simplified codes that are intended to model the performance-critical computations within applications. Applications executing on modern High Performance Computing (HPC) systems are susceptible to network congestion, insufficient memory bandwidth within and across compute nodes, and inadvertent loss of performance due to bugs and unoptimized programming models. Modern numerical simulations and machine learning models play a critical role in studying physical phenomenon under myriad uncertainties. Such applications often exhibit irregular computation and memory accesses at specific regions of the application code, which can contribute to various performance bottlenecks at scale. To mitigate such issues and prepare the next generation hardware for a variety of computation and data movement contingencies, a well-known practice is to consider "proxy" applications as representative motifs for various classes of scientific applications. While there is disagreement in the HPC community on the mechanisms of construction of the proxy applications, there is a strong consensus on their positive impact in co-design. Proxy Applications for Converged Workloads (PACER) is about facilitating software-hardware co-design through proxy applications with the goal of improving the performance of converged science workflows on heterogeneous systems.

97 MATHEMATICS AND COMPUTING↗

New Two-Cylinder Prototype Demonstration and Concept Design of a Next Generation Class 3-6 Opposed Piston Engine (Final Report)

The objective of the project is to research, develop, and test an Opposed Piston (OP) engine prototype capable of ≥10% fuel economy improvement over a 2015 baseline diesel engine while meeting prevailing emissions standards and include a cost analysis of the proposed technologies that validates an operating cost payback of less than 2 years. Results: In direct comparison with the baseline Isuzu model, the OP engine exhibited a noteworthy average fuel economy improvement exceeding 12% across five distinct driving cycles, including the Interstate cycle, Congested interstate cycle, GM-city cycle, HWFET cycle, and FTP cycle, with Interstate cycle benefited the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Options for Meeting Data Center Demand in Virginia: Focus on GETs and Reconductoring [Slides]

Data center demand growth in Virginia will need to met with many options - GETs and/or reconductoring have the potential to be part of the solution suite in the short-term and medium-term. Almost all GETs and reconductoring technologies have more favorable economics than transmission wires investments considering relatively low levels of existing wide-scale deployment. Deployment of GETs and/or reconductoring is not a one size fits all - requires detailed analysis. The complementary nature of GETs and/or reconductoring impacts have the potential to be synergistic (more congestion relief, more transfer capability, more cost savings - when implemented together).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating the Mobility Energy Productivity Metric into the CDOT Statewide Model

The Mobility Energy Productivity (MEP) metric measures the quality of mobility at a specific location and can be used to evaluate how changes to transportation systems impact the mobility of that location over time, such as through infrastructure investments. The objective of this study is to demonstrate integration of the MEP metric into CDOT's transportation planning process by leveraging data from their statewide travel demand model. We evaluate the MEP metric in 2015 as well as 2030 baselines and projected impacts in 2030 for two different regions in Colorado under multiple scenarios across multiple modes (driving, walking, biking, and transit). It was found that increasing development (increasing population density, jobs, and opportunities) had a significant impact on MEP, independent of any specific alternatives. For drive mode, there was a trade- off of increasing congestion on the road network and increasing job and opportunity access. Impacts to bike, walk, and transit MEP were also demonstrated in both regions. This report shows how MEP can be used as a tool to support evaluating the impacts of various transportation projects across the state. With projections of significant growth across the state of Colorado, access to the increasing opportunities and jobs will be important to understand through the context of energy efficiency. MEP could support future project evaluation and decision-making by enabling the unique and important dimension of energy- efficient accessibility of a transportation system.

33 ADVANCED PROPULSION SYSTEMS↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

Unraveling the Noise: An Investigation Plan for Signal Interference in Hearing Aids

Bluetooth Low Energy (BLE) has revolutionized the performance of hearing aids with functionalities like seamless audio streaming and enhanced auditory functions. However, BLE operates within the highly congested 2.4 GHz frequency band, making it susceptible to signal interference that can degrade performance, reduce audio quality, and impact user experience. This paper documents interference patterns in BLE communication and introduces practical mitigation techniques aimed at improving the reliability of hearing aids. Attack vectors associated with Bluetooth enabled hearing aids include communication jamming, the interception of data between target devices, and GATT handle exploitation. Attackers could also use the vulnerabilities to block communications or intercept sensitive audio streams, posing significant security and privacy risks. These threats compromise two critical components of the CIA triad: (1) availability, by causing persistent connectivity issues, and (2) integrity, by enabling unauthorized data modifications. It is necessary to deal with these problems to ensure hearing aids work well and safely. This study investigates the impact of BLE signal interference on hearing aids, using tools such as HackRF [1], a Python tool to simulate interference scenarios, and Ubertooth [2] to sniff Bluetooth traffic between hearing aids and the device with the application. This paper investigates testing of BLE traffic in search of specific interference patterns that would impact the functionality of hearing aids, including jamming and flooding. This research focuses on developing robust mitigation techniques with the aim of securing BLE-enabled hearing aids against those vulnerabilities.

Baldwin, David [Savannah River National Laboratory↗

Investigation into the Performance Benefits of Exposing Network Backpressure in UPC++ and GASNet-EX

This document is a brief summary of the research, and supporting development efforts, conducted by the project "Investigation into Improving Dynamic Adaptivity to System-Level Asynchrony in UPC++". We tested the hypothesis "The UPC++ and GASNet-EX runtimes can expose information from the network stack that enables applications to dynamically adapt to congestion, improving total throughput". We present experimental results from both a microbenchmark and an application benchmark that support this hypothesis.

97 MATHEMATICS AND COMPUTING↗

Empirical Indicators of Transmission Value in the Southeast United States

Concurrent differences in energy price between different parts of the electric grid are a key indicator of the value of additional transmission. In areas without a wholesale electricity market, such as the Southeast, an alternative indicator to price is the Federal Energy Regulatory Commission’s (FERC) system lambda data. This economic metric represents the minimized marginal production costs of thermal generators, including fuel and other variable operation and maintenance expenses. Balancing Authorities report a single system lambda for their entire balancing area. Most Southeastern lambdas exhibit sufficient price variation to support a transmission valuation analysis, although incomplete accounting of congestion costs or scarcity rents during peak load hours may underestimate the true value of transmission capacity. With transmission value defined as the annual average hourly absolute price difference between two regions and FERC’s system lambda data used as a price proxy, we find the following results in the Southeast region during 2012-2023 (reported in $\$2024$/MWh): Intra‐regional findings: Annual averages historically span $\$2$–$\$28$/MWh and average $\$12$/MWh in SERTP and span $\$4$–$\$19$/MWh and average $\$9$/MWh in FRCC, disregarding transmission value driven by anomalous data. The ranges of transmission value reported here are large, spanning an order of magnitude in some cases. Much of this variation is driven by year-to-year changes, with 2022 having a particularly high intra-regional transmission value due to elevated natural gas prices. Inter‐regional corridors: Annual average transmission values across three broader regions range from $\$6$ to $\$28$/MWh with a long-term average of $\$11$/MWh. Much of the transmission value is concentrated in a small portion of hours. Across all regions, severe weather—particularly polar vortex events in January 2018, February 2021, and December 2022—drives the largest price spreads. Seasonal patterns also emerge, with summer afternoons and fall mornings contributing consistently to transmission value, as for example between MISO and SOCO in 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing Trip Chaining Behavior in New York State Using 2009 and 2017 National Household Travel Survey

Trip chaining, defined as the sequential linking of trips by individuals throughout a given day, provides critical insights into daily mobility patterns and activity sequencing. Understanding these patterns has significant implications for transportation demand forecasting, congestion management, and local economic activity. This analysis examines trip chaining behaviors in New York State (NYS) for the years 2009 and 2017 and compares the Middle Atlantic Census Division with other U.S. regions in 2022, utilizing data from the National Household Travel Survey (NHTS). Through demographic, geographic, and temporal analysis, this study characterizes how populations organize travel for work, personal errands, and social activities, providing empirical evidence of evolving trip chaining behaviors to inform transportation planning strategies.

99 GENERAL AND MISCELLANEOUS↗

Surveillance & Detection (CRADA 567 Final Report)

This Cooperative Research and Development Agreement (CRADA) Final Report covers the work achieved by PNNL and it's commercial partner (Consolidated Resource Imaging, LLC) on video analytics for the DHS S&T Surveillance & Detection project. This project has been focused on development of the next-generation camera system (Guardian iiS) with extremely high resolution and video analytics specifically designed for crowded urban environments and congested transportation hubs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

New Mobility Technology Assessment - Benefits, Risks, and Safety

The age of vehicle automation is upon us. The fundamental perception and control technology is maturing as we speak (and write) with robo-taxis proliferating in select US cities. The news cycle is no longer filled with technological skepticism, but rather societal commentary on our collective response and use of the technology. This maturing of the technology is also accompanied by a renaissance in new types of urban movement technology to more effectively link people with goods, services, and employment, particularly in dense development areas where vehicle congestion (even automated vehicles) prevents high quality mobility. The National Renewable Energy Laboratory, through the DOE Clean Energy to Communities (C2C) program has worked with two jurisdictions to assess the benefits, risks, and safety concerns for a new product offering based on suspended cable technology which is fully automated and proposes an aerial network of self-propelled gondolas. The recognized need, independent of the technology, is to fairly assess the benefits of the proposed transportation system, assess its technical maturity, as well as risks and safety concerns. Using this new technology as an example, a technology represented by Swyft Cities, NREL developed a succession of mini-studies that characterized the technical maturity level, assessed the proposed benefits for Greenville, SC, examined the risks involved in moving forward with an emerging mobility technology, and determined the governing safety protocols and standards that are applicable to the space. These mini-case studies, though centered on Swyft Cities aerial automated gondola technology, are highly transferable to any type of new mobility technology and lays out a repeatable process for assessing new technology within an city or community context.

33 ADVANCED PROPULSION SYSTEMS↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗