Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Bone Development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

510 records · Page 29

Space radiation absorbed dose distribution in a human phantom

The radiation risk to astronauts has always been based on measurements using passive thermoluminescent dosimeters (TLDs). The skin dose is converted to dose equivalent using an average radiation quality factor based on model calculations. The radiological risk estimates, however, are based on organ and tissue doses. This paper describes results from the first space flight (STS-91, 51.65 degrees inclination and approximately 380 km altitude) of a fully instrumented Alderson Rando phantom torso (with head) to relate the skin dose to organ doses. Spatial distributions of absorbed dose in 34 1-inch-thick sections measured using TLDs are described. There is about a 30% change in dose as one moves from the front to the back of the phantom body. Small active dosimeters were developed specifically to provide time-resolved measurements of absorbed dose rates and quality factors at five organ locations (brain, thyroid, heart/lung, stomach and colon) inside the phantom. Using these dosimeters, it was possible to separate the trapped-proton and the galactic cosmic radiation components of the doses. A tissue-equivalent proportional counter (TEPC) and a charged-particle directional spectrometer (CPDS) were flown next to the phantom torso to provide data on the incident internal radiation environment. Accurate models of the shielding distributions at the site of the TEPC, the CPDS and a scalable Computerized Anatomical Male (CAM) model of the phantom torso were developed. These measurements provided a comprehensive data set to map the dose distribution inside a human phantom, and to assess the accuracy and validity of radiation transport models throughout the human body. The results show that for the conditions in the International Space Station (ISS) orbit during periods near the solar minimum, the ratio of the blood-forming organ dose rate to the skin absorbed dose rate is about 80%, and the ratio of the dose equivalents is almost one. The results show that the GCR model dose-rate predictions are 20% lower than the observations. Assuming that the trapped-belt models lead to a correct orbit-averaged energy spectrum, the measurements of dose rates inside the phantom cannot be fully understood. Passive measurements using 6Li- and 7Li-based detectors on the astronauts and inside the brain and thyroid of the phantom show the presence of a significant contribution due to thermal neutrons, an area requiring additional study.

STS-91 Shuttle Project↗

Advances in Rodent Research Missions on the International Space Station

A Research platform for rodent experiment on the ISS is an essential tool for advancing biomedical research in space. The Rodent Research allows for experiments of much longer duration that experiments on the Shuttle. NASA’s Rodent Research (RR)-1 mission was successfully completed, including post-flight analysis and achieved a number of objectives including validation of flight hardware, on-orbit operations, and science capabilities that were developed at the NASA Ames Research Center. Briefly, twenty C57BL/6J adult female mice were launched on the SpX4 Dragon vehicle, which thrived for up to 37 days in microgravity. Daily health checks of the mice were performed during the mission via downlinked video; all animals were healthy and displayed normal behavior without any significant signs of stress. Behavioral analysis demonstrated that Flight and Ground Control mice exhibited the same range of behaviors, including eating, drinking, exploratory behavior, self- and allo-grooming, and social interactions indicative of healthy animals. The animals were euthanized and select tissues were collected from some of the mice on orbit to assess the long-term sample storage capabilities of the ISS. The data obtained from the flight mice were comparable to those from the 3 groups of control mice (baseline, vivarium and ground controls), suggesting that the ISS has adequate capability to support long-duration rodent experimentations. We recovered over 35 tissues from 40 RR1 frozen carcasses, yielded over 3200 aliquots of tissues, and distributed to the scientific community, including NASA’s GeneLab and scientists in the U.S. through Biospecimen Sharing Program via Ames Life Science Data Archive. Tissues were also distributed to Russian research colleagues at the Institute for Biomedical Problems. The expression levels of select genes including albumin, catalase, GAPDH, HMGCoA Reductase, and IGF1 were determined using RNA isolated from the livers by qPCR and no significant differences by one factor ANOVA were found between flight and ground control groups. In addition, some of the liver samples were subject to transcriptomics, epigenomics and proteomics. The data are now available to the scientific community through GeneLab’s open science data website. Since the RR1 mission, another long duration mission (Rodent Research-2) was completed on the ISS in 2015 in which 20 female C57 BL/6J mice were successfully maintained on the ISS for varying time points, with the last group of 5 animals being on-orbit for 54 days. This second Rodent Research flight expanded the program’s capabilities with the introduction of new technologies including blood collection and separation and bone densitometry scanning. Furthermore, we have continued to expand the ISS’s capabilities by running a series of ground-based verification testing using male mice. Our next step is to fly male mice for Rodent Research-4 on SpaceX-10 to study the effects of microgravity on bone healing and regeneration. It will be the first long-duration mission using male mice using Rodent Hardware. In addition, the number of mice will increase from 20 mice (on RR-1 and RR-2) to 40 for RR-4. When samples return to Earth, a number of tissues will be dissected from the frozen carcasses and select tissue samples will become available to the scientific community via BSP. Altogether, we have continued to expand our capabilities for performing long-duration missions on the ISS as emphasized in the National Research Council’s Decadal Survey released in 2011 and to maximize science return from each mission.

Choi, S.↗

ISS Squat and Deadlift Kinematics on the Advanced Resistive Exercise Device

Visual assessment of exercise form on the Advanced Resistive Exercise Device (ARED) on orbit is difficult due to the motion of the entire device on its Vibration Isolation System (VIS). The VIS allows for two degrees of device translational motion, and one degree of rotational motion. In order to minimize the forces that the VIS must damp in these planes of motion, the floor of the ARED moves as well during exercise to reduce changes in the center of mass of the system. To help trainers and other exercise personnel better assess squat and deadlift form a tool was developed that removes the VIS motion and creates a stick figure video of the exerciser. Another goal of the study was to determine whether any useful kinematic information could be obtained from just a single camera. Finally, the use of these data may aid in the interpretation of QCT hip structure data in response to ARED exercises performed in-flight. After obtaining informed consent, four International Space Station (ISS) crewmembers participated in this investigation. Exercise was videotaped using a single camera positioned to view the side of the crewmember during exercise on the ARED. One crewmember wore reflective tape on the toe, heel, ankle, knee, hip, and shoulder joints. This technique was not available for the other three crewmembers, so joint locations were assessed and digitized frame-by-frame by lab personnel. A custom Matlab program was used to assign two-dimensional coordinates to the joint locations throughout exercise. A second custom Matlab program was used to scale the data, calculate joint angles, estimate the foot center of pressure (COP), approximate normal and shear loads, and to create the VIS motion-corrected stick figure videos. Kinematics for the squat and deadlift vary considerably for the four crewmembers in this investigation. Some have very shallow knee and hip angles, and others have quite large ranges of motion at these joints. Joint angle analysis showed that crewmembers do not return to a normal upright stance during squat, but remain somewhat bent at the hips. COP excursions were quite large during these exercises covering the entire length of the base of support in most cases. Anterior-posterior shear was very pronounced at the bottom of the squat and deadlift correlating with a COP shift to the toes at this part of the exercise. The stick figure videos showing a feet fixed reference frame have made it visually much easier for exercise personnel and trainers to assess exercise kinematics. Not returning to fully upright, hips extended position during squat exercises could have implications for the amount of load that is transmitted axially along the skeleton. The estimated shear loads observed in these crewmembers, along with a concomitant reduction in normal force, may also affect bone loading. The increased shear is likely due to the surprisingly large deviations in COP. Since the footplate on ARED moves along an arced path, much of the squat and deadlift movement is occurring on a tilted foot surface. This leads to COP movements away from the heel. The combination of observed kinematics and estimated kinetics make squat and deadlift exercises on the ARED distinctly different from their ground-based counterparts. CONCLUSION This investigation showed that some useful exercise information can be obtained at low cost, using a single video camera that is readily available on ISS. Squat and deadlift kinematics on the ISS ARED differ from ground-based ARED exercise. The amount of COP shift during these exercises sometimes approaches the limit of stability leading to modifications in the kinematics. The COP movement and altered kinematics likely reduce the bone loading experienced during these exercises. Further, the stick figure videos may prove to be a useful tool in assisting trainers to identify exercise form and make suggestions for improvements

Newby, N.↗

GCR Transport in the Brain: Assessment of Self-Shielding, Columnar Damage, and Nuclear Reactions on Cell Inactivation Rates

Radiation shield design is driven by the need to limit radiation risks while optimizing risk reduction with launch mass/expense penalties. Both limitation and optimization objectives require the development of accurate and complete means for evaluating the effectiveness of various shield materials and body-self shielding. For galactic cosmic rays (GCR), biophysical response models indicate that track structure effects lead to substantially different assessments of shielding effectiveness relative to assessments based on LET-dependent quality factors. Methods for assessing risk to the central nervous system (CNS) from heavy ions are poorly understood at this time. High-energy and charge (HZE) ion can produce tissue events resulting in damage to clusters of cells in a columnar fashion, especially for stopping heavy ions. Grahn (1973) and Todd (1986) have discussed a microlesion concept or model of stochastic tissue events in analyzing damage from HZE's. Some tissues, including the CNS, maybe sensitive to microlesion's or stochastic tissue events in a manner not illuminated by either conventional dosimetry or fluence-based risk factors. HZE ions may also produce important lateral damage to adjacent cells. Fluences of high-energy proton and alpha particles in the GCR are many times higher than HZE ions. Behind spacecraft and body self-shielding the ratio of protons, alpha particles, and neutrons to HZE ions increases several-fold from free-space values. Models of GCR damage behind shielding have placed large concern on the role of target fragments produced from tissue atoms. The self-shielding of the brain reduces the number of heavy ions reaching the interior regions by a large amount and the remaining light particle environment (protons, neutrons, deuterons. and alpha particles) may be the greatest concern. Tracks of high-energy proton produce nuclear reactions in tissue, which can deposit doses of more than 1 Gv within 5 - 10 cell layers. Information on rates of cell killing from GCR, including patterns of cell killing from single particle tracks. can provide useful information on expected differences between proton and HZE tracks and clinical experiences with photon irradiation. To model effects on cells in the brain, it is important that transport models accurately describe changes in the GCR due to interactions in the cranium and proximate tissues. We describe calculations of the attenuated GCR particle fluxes at three dose-points in the brain and associated patterns of cell killing using biophysical models. The effects of the brain self-shielding and bone-tissue interface of the skull in modulating the GCR environment are considered. For each brain dose-point, the mass distribution in the surrounding 4(pi) solid angle is characterized using the CAM model to trace 512 rays. The CAM model describes the self-shielding by converting the tissue distribution to mass-equivalent aluminum, and nominal values of spacecraft shielding is considered. Particle transport is performed with the proton, neutron, and heavy-ion transport code HZETRN with the nuclear fragmentation model QMSFRG. The distribution of cells killed along the path of individual GCR ions is modeled using in vitro cell inactivation data for cells with varying sensitivity. Monte Carlo simulations of arrays of inactivated cells are considered for protons and heavy ions and used to describe the absolute number of cell killing events of various magnitude in the brain from the GCR. Included are simulations of positions of inactivated cells from stopping heavy ions and nuclear stars produced by high-energy ions most importantly, protons and neutrons.

Shavers, M. R.↗

Advances in Rodent Research Missions on the International Space Station

A research platform for rodent experiment on the ISS is a valuable tool for advancing biomedical research in space. Capabilities offered by the Rodent Research project developed at NASA Ames Research Center can support experiments of much longer duration on the ISS than previous experiments performed on the Space Shuttle. NASAs Rodent Research (RR)-1 mission was completed successfully and achieved a number of objectives, including validation of flight hardware, on-orbit operations, and science capabilities as well as support of a CASIS-sponsored experiment (Novartis) on muscle atrophy. Twenty C57BL6J adult female mice were launched on the Space-X (SpX) 4 Dragon vehicle, and thrived for up to 37 days in microgravity. Daily health checks of the mice were performed during the mission via downlinked video; all flight animals were healthy and displayed normal behavior, and higher levels of physical activity compared to ground controls. Behavioral analysis demonstrated that Flight and Ground Control mice exhibited the same range of behaviors, including eating, drinking, exploratory behavior, self- and allo-grooming, and social interactions indicative of healthy animals. The animals were euthanized on-orbit and select tissues were collected from some of the mice on orbit to assess the long-term sample storage capabilities of the ISS. In general, the data obtained from the flight mice were comparable to those from the three groups of control mice (baseline, vivarium and ground controls, which were housed in flight hardware), showing that the ISS has adequate capability to support long-duration rodent experiments. The team recovered 35 tissues from 40 RR-1 frozen carcasses, yielding 3300 aliquots of tissues to distribute to the scientific community in the U.S., including NASAs GeneLab project and scientists via Space Biology's Biospecimen Sharing Program Ames Life Science Data Archive. Tissues also were distributed to Russian research colleagues at the Institute for Biomedical Problems. The expression levels of select genes including albumin, catalase, GAPDH, HMGCoA Reductase, and IGF1 were determined using RNA isolated from the livers by qPCR and no significant differences by one factor ANOVA were found between flight and ground control groups. In addition, some of the liver samples were analyzed for transcriptomic, epigenomic and proteomic profiles; some of the data sets are now available to the scientific community through GeneLabs open science data website. A second long duration mission, Rodent Research-2 (RR-2) was completed on the ISS in 2015; 20 female C57BL6J mice were successfully maintained on the ISS for various durations, with the last group of 5 animals living on-orbit for 54 days. Furthermore, we continue to expand the ISSs capabilities by introducing new on-orbit technologies including blood collection and separation, bone densitometry scanning, muscle grip strength and anesthesia with recovery. In addition, series of ground-based verification testing to fly male mice and increase the total number of mice on-orbit from 20 to 40. Subsequent missions will provide the capability to return live mice from the ISS animals to evaluate recovery on Earth, further expanding operational and science capabilities of the RR project on the ISS.

Choi, S. Y.↗

Modeling and Simulation for Exercise Vibration Isolation and Stabilization System Design

The microgravity environment that crew members experience on orbit presents a well-known health challenge, particularly when it comes to loss of muscle and bone mass. To counteract these negative effects, exercise countermeasures play a critical role in the daily routine of the crew on the International Space Station (ISS). To help inform requirements for upcoming exploration missions such as the Gateway Program, a new device, called the European Enhanced Exploration Exercise Device (E4D), is being built by the European Space Agency through their contractor, the Danish Aerospace Company. The E4D is being demonstrated on the ISS and is unique from other current exercise devices in that it provides four separate modalities in a single device: resistive, cycle ergometry, seated aerobic rowing, and rope pulling. To support the integration of E4D on ISS, a passive Vibration Isolation and Stabilization (VIS) system was required by NASA, and this responsibility was given to the Johnson Space Center. This paper describes the end-to-end process of modeling, simulation, and analysis used to inform the mechanical design of the VIS system. The process begins with the collection of representative exerciser motion capture (MoCap) through ground-based testing with the developmental E4D in both the Prototype Immersive Technology (PIT) Laboratory and the Active Response Gravity Offload System (ARGOS) facility at the Johnson Space Center. These collected MoCap data are processed through human biomechanics modeling to create forcing functions as input to a multibody dynamics simulation of the combined E4D/VIS system, with numerous resulting outputs. These outputs include microgravity accelerations, overall system displacements, internal and transmitted loads, as well as collisions. Microgravity accelerations are compared for compliance against ISS requirements while displacements are used for sway space determinations on the design and volumetric constraints within the targeted module. Internal loads are supplied to the supporting stress analysis teams and external loads for structural loads and dynamics teams, both at NASA and ESA. Finally, contact and clearance analysis is performed using the simulation to eliminate potential design issues. To ensure that the elements of the multibody simulation were verified and validated, correlation against multiple VIS related ground hardware testbeds was performed and characterized. In addition to the isolation part of the VIS problem, stabilization is also key to the integrated performance and evaluation. Due to the difficulty in defining ISS requirements in this area, the stability of the exerciser was inspected via analysis. Loss of balance was defined analytically as occurring when the resultant force vector acting on the exerciser lies outside the base of support of the feet. Both the VIS and E4D teams have recently gone through their Critical Design Reviews (CDRs) and the iterative model-based approach has been integral to inform mechanical design, particularly in the case of the VIS. This same end-to-end approach is now being applied for the Gateway Program, where an Exploration Exercise Device (EED) derived from the E4D and notional VIS for the device are under concept development.

Countermeasures↗