Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Blind”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Multiview marker-free registration of forest terrestrial laser scanner data with embedded confidence metrics

Terrestrial laser scanning has demonstrated increasing potential for rapid comprehensive measurement of forest structure, especially when multiple scans are spatially registered in order to reduce the limitations of occlusion. Although marker-based registration techniques (based on retro-reflective spherical targets) are commonly used in practice, a blind marker-free approach is preferable, insofar as it supports rapid operational data acquisition. To support these efforts, we extend the pairwise registration approach of our earlier work, and develop a graph-theoretical framework to perform blind marker-free global registration of multiple point cloud data sets. Pairwise pose estimates are weighted based on their estimated error, in order to overcome pose conflict while exploiting redundant information and improving precision. The proposed approach was tested for eight diverse New England forest sites, with 25 scans collected at each site. Quantitative assessment was provided via a novel embedded confidence metric, with a mean estimated root-mean-square error of 7.2 cm and 89% of scans connected to the reference node. Lastly, this paper assesses the validity of the embedded multiview registration confidence metric and evaluates the performance of the proposed registration algorithm.

47 OTHER INSTRUMENTATION↗

Actinide in Air (Rn-Progeny Rejected) Alpha Spectroscopy With Tensioned Metastable Fluid Detectors

Here, this article discusses outcome of research for deriving a methodology and apparatus for ascertaining for the presence of ultratrace-level actinides in air from their alpha emission signatures, while remaining blind to the relatively large (1000× higher activity) alpha emissions from Rn-progeny. Apparatus and techniques were developed to collect and characterize alpha-emitting nuclides of Rn-progeny and actinides in air on a polycarbonate 3 μm pore size continuous air monitor (CAM) filter. A wet-chemistry approach was developed and validated for successfully separating the Rn-progeny alpha emitting isotopes of Po-214 and Po-218, while extracting the actinides (U, Pu, Am) in a fluid mixture that is suitable for conduct of alpha spectroscopy with a centrifugally tensioned metastable fluid detector (CTMFD). The resulting α-TMFD technology was compared against the state-of-art “Alpha-Sentry™” Continuous Air Monitor (CAM) system commonly utilized world-wide. Results indicate that the α-TMFD technology can potentially offer complementary and superior performance in multiple performance categories, and ∼18× improvement in the time to detect (e.g., at 0.02 derived air concentration (DAC) within ∼3 h, versus ∼70 h for Alpha-Sentry) for actinides of interest while also remaining ∼100% blind to ∼10 3 × higher Rn-progeny background—with the added potential for offering few keV scale energy resolution without resorting to peak shape fitting, versus ∼300–400 keV for existing CAM systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TRANSIENT THERMAL MODELING OF THE HIGH BURNUP DEMONSTRATION RESEARCH PROJECT CASK USING STAR-CCM+ AND COBRA-SFS

The Department of Energy in collaboration with the Electric Power Research Institute is in the process of conducting the High Burnup Demonstration Project. Where the objective is to characterize the performance of high-burnup fuel in long term storage. As part of this demonstration, a TN-32B dry storage cask was instrumented and loaded with spent nuclear fuel at North Anna Nuclear Generating Station in November 2017. The project cask provides a unique opportunity to gain information on spent fuel and cask performance from an in-service operational system. The cask was instrumented with thermocouples inside of the fuel assemblies, then loaded and dried using normal procedures. After the drying process a thermal soak period where the cask was left indoors was used to obtain steady temperatures for model comparison along with surface temperatures. This paper details thermal modeling validation work that was done to model both the steady state and transient cases. Two modeling tools were used to predict temperatures in the cask. The general purpose CFD and heat transfer code STAR-CCM+ was used with both a detailed pin-by-pin model was used along with a more efficient k-effective simplification. The other code is COBRA-SFS, a purpose-built detailed thermal modeling tool developed and maintained at PNNL. Results from all the modeling tools were compared blind to the test data. Each model utilized general design information and compared reasonably well to the blind steady state data using convection and surface temperature boundary conditions. Post-test adjustments were later made to better reflect the “as built” conditions of the cask. Based on lessons learned from the steady state analysis the vacuum drying process was modeled in both codes. Utilizing the measured loading conditions the transient models were able to compare very well with the measured data. Overall the project showed an ability to model spent fuel storage conditions very well and future work is planned to generalize the methodology used for vacuum drying.

Thermal Analysis, Spent Fuel, Dry Storage↗

Phantom experiments to improve parathyroid lesion detection

This investigation tested the hypothesis that visual analysis of iteratively reconstructed tomograms by ordered subset expectation maximization (OSEM) provides the highest accuracy for localizing parathyroid lesions using {sup 99m}Tc-sestamibi SPECT data. From an Institutional Review Board approved retrospective review of 531 patients evaluated for parathyroid localization, image characteristics were determined for 85 {sup 99m}Tc-sestamibi SPECT studies originally read as equivocal (EQ). Seventy-two plexiglas phantoms using cylindrical simulated lesions were acquired for a clinically realistic range of counts (mean simulated lesion counts of 75{+-}50 counts/pixel) and target-to-background (T:B) ratios (range=2.0 to 8.0) to determine an optimal filter for OSEM. Two experienced nuclear physicians graded simulated lesions, blinded to whether chambers contained radioactivity or plain water, and two observers used the same scale to read all phantom and clinical SPECT studies, blinded to pathology findings and clinical information. For phantom data and all clinical data, T:B analyses were not statistically different for OSEM versus FB, but visual readings were significantly more accurate than T:B (88{+-}6% versus 68{+-}6%, p=0.001) for OSEM processing, and OSEM was significantly more accurate than FB for visual readings (88{+-}6% versus 58{+-}6%, p<0.0001). These data suggest that visual analysis of iteratively reconstructed MIBI tomograms should be incorporated into imaging protocols performed to localize parathyroid lesions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-G-17A-05: PET Image Deblurring Using Adaptive Dictionary Learning

Purpose: The aim of this work is to deblur PET images while suppressing Poisson noise effects using adaptive dictionary learning (DL) techniques. Methods: The model that relates a blurred and noisy PET image to the desired image is described as a linear transform y=Hm+n where m is the desired image, H is a blur kernel, n is Poisson noise and y is the blurred image. The approach we follow to recover m involves the sparse representation of y over a learned dictionary, since the image has lots of repeated patterns, edges, textures and smooth regions. The recovery is based on an optimization of a cost function having four major terms: adaptive dictionary learning term, sparsity term, regularization term, and MLEM Poisson noise estimation term. The optimization is solved by a variable splitting method that introduces additional variables. We simulated a 128×128 Hoffman brain PET image (baseline) with varying kernel types and sizes (Gaussian 9×9, σ=5.4mm; Uniform 5×5, σ=2.9mm) with additive Poisson noise (Blurred). Image recovery was performed once when the kernel type was included in the model optimization and once with the model blinded to kernel type. The recovered image was compared to the baseline as well as another recovery algorithm PIDSPLIT+ (Setzer et. al.) by calculating PSNR (Peak SNR) and normalized average differences in pixel intensities (NADPI) of line profiles across the images. Results: For known kernel types, the PSNR of the Gaussian (Uniform) was 28.73 (25.1) and 25.18 (23.4) for DL and PIDSPLIT+ respectively. For blinded deblurring the PSNRs were 25.32 and 22.86 for DL and PIDSPLIT+ respectively. NADPI between baseline and DL, and baseline and blurred for the Gaussian kernel was 2.5 and 10.8 respectively. Conclusion: PET image deblurring using dictionary learning seems to be a good approach to restore image resolution in presence of Poisson noise. GE Health Care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-B-16A-01: To Which Journal Should I Submit My Paper

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given the large number (about 100) competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. The senior editors for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase chances of acceptance To help decipher which journal is appropriate for a given work.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-I-33: Establishment of CT Diagnostic Reference Levels in Province Nova Scotia

Purpose: To evaluate patient radiation dose from the most frequently performed CT examinations and to establish provincial diagnostic reference levels (DRLs) as a tool for protocol optimization. Methods: The study investigated the following CT examinations: head, chest, abdomen/pelvis, and chest/abdomen/pelvis (CAP). Dose data, volume CT dose index (CTDIvol) and dose-length product (DLP), were collected from 15 CT scanners installed during 2004–2014 in 11 hospital sites of Nova Scotia. All scanners had dose modulation options and multislice capability (16–128 detector rows). The sample for each protocol included 15 average size patients (70±20 kg). Provincial DRLs were calculated as the 75th percentile of patient dose distributions. The differences in dose between hospitals were evaluated with a single factor ANOVA statistical test. Generalized linear modeling was used to determine the factors associated with higher radiation dose. A sample of 36 abdominal studies performed on three different scanners was blinded and randomized for an assessment by an experienced radiologist who graded the imaging quality of anatomic structures. Results: Data for 900 patients were collected. The DRLs were proposed using CTDIvol (mGy) and DLP (mGy*cm) values for CT head (67 and 1049, respectively), chest (12 and 393), abdomen/pelvis (16 and 717), and CAP (14 and 1034). These DRLs were lower than the published national data except for the head CTDIvol. The differences between the means of the dose distributions from each scanner were statistically significant (p<0.05) for all examinations. A very weak correlation was found between the dose and the scanner age or the number of slices with Pearson’s correlation coefficients of 0.011–0.315. The blinded analysis of image quality demonstrated no clinically significant difference except for the noise category. Conclusion: Provincial DRLs were established for typical CT examinations. The variations in dose between the hospitals suggested a large potential for optimization of examinations. Radiology Research Foundation grant.

60 APPLIED LIFE SCIENCES↗

SU-F-I-57: Evaluate and Optimize PET Acquisition Overlap in 18F-FDG Oncology Wholebody PET/CT: Can We Scan PET Faster?

Purpose: The longer patient has to remain on the table during PET imaging, the higher the likelihood of motion artifacts due to patient discomfort. This study was to investigate and optimize PET acquisition overlap in 18F-FDG oncology wholebody PET/CT to speed up PET acquisition and improve patient comfort. Methods: Wholebody 18F-FDG PET/CT of phantoms, 8 pre-clinical patients (beagles) and 5 clinical oncology patients were performed in 90s/bed on a time-of-flight Gemini TF 64 system. Imaging of phantoms and beagles was acquired with reduced PET overlaps (40%, 33%, 27%, 20%, 13% and no overlap) in addition to the system default (53%). In human studies, 1 or 2 reduced overlaps from the listed options were used to acquire PET/CT sweeps right after the default standard of care imaging. Image quality was blindly reviewed using visual scoring criteria and quantitative SUV assessment. NEMA PET sensitivity was performed under different overlaps. Results: All PET exams demonstrated no significant impact on the visual grades for overlaps >20%. Blinded reviews assigned the best visual scores to PET using overlaps 53%–27%. Reducing overlap to 27% for oncology patients (12-bed) saved an average of ∼40% acquisition time (11min) compared to using the default overlap (18min). No significant SUV variances were found when reducing overlap to half of default for cerebellum, lung, heart, aorta, liver, fat, muscle, bone marrow, thighs and target lesions (p>0.05), except expected variability in urinary system. Conclusion: This study demonstrated by combined phantom, pre-clinical and clinical PET/CT scans that PET acquisition overlap in axial of today’s systems can be reduced and optimized. It showed that a reduction of PET acquisition overlap to 27% (half of system default) can be implemented to reduce table time by ∼40% to improve patient comfort and minimize potential motion artifacts, without prominently degrading image quality or compromising PET quantification.

60 APPLIED LIFE SCIENCES↗

MO-G-201-04: Knowledge-Based Planning for Single-Isocenter Stereotactic Radiosurgery to Multiple Brain Metastases

Purpose: Single-isocenter, linac-based SRS for multiple brain metastases (multi-mets) can deliver highly conformal radiation doses and reduce overall patient treatment time compared to other therapy techniques. This study aims to quantify the dosimetric benefits of knowledge-based planning (KBP) for multi-met treatments. Methods: Using a previously-published KBP methodology (an artificial neural network (ANN) trained on single-target linac-based SRS plans), 3D dose distribution predictions for multi-met patients were obtained by treating each brain lesion as a solitary target and subsequently combining individual predictions into a single distribution using a dose-weighted geometric averaging to obtain the best results in the inter-target space. 17 previously-treated multi-met plans, with target numbers ranging from N=2–5, were used to validate the ANN predictions and subsequent KBP auto-planning routine. The fully-deliverable KBP plans were developed by converting dose distribution predictions into patient-specific optimization objectives while maintaining identical target normalizations (typically PTV V100%=D98%). Plan quality improvements were quantified by the difference between SRS quality metrics (QMs): δdQM=QM(clinical)-QM(KBP). QMs of interest were: gradient measure (GM), conformity index (CI), brain V10 and V5, brainstem D0.1cc and heterogeneity index (HI). Finally, overall plan quality was judged via blinded plan comparison by SRS-specializing physicians. Results: Two clinical plans were found to be significant outliers wherein plan quality was dramatically worse than KBP. Despite indicating KBP superiority, these were removed from the QM analysis to prevent skewing the results. In the remaining cases, clinical and KBP QMs were nearly identical with modest improvements in the KBP sample: δGM=0.12±0.56mm, δCI=−0.01±0.04, Brain δV10=0.8±2.6cc, brain δV5=6.3 ±10.7cc, brainstem δD0.1cc=0.06±1.19Gy and δHI= −0.04±0.05. Ultimately, 13/17 KBP plans were deemed superior to the manual plans in blinded physician review. Conclusion: The results demonstrate that KBP-driven automated planning in linac-based single-isocenter treatments for multiple brain metastases is indistinguishable from, or even better than, traditional manual planning. J. Hattangadi: Research Grant; Varian Medical Systems; K.L. Moore: Research Grant: Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

WE-E-204-00: Where to Send My Manuscript

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given dozens of competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Radiology, Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. Senior members of the editorial board for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; open access policies, the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. Other journals will be discussed as well. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the quality and impact of the paper and the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase quality, impact and chances of acceptance To help decipher which journal is appropriate for a given work A. Karellas, Research collaboration with Koning, Corporation.

60 APPLIED LIFE SCIENCES↗

WE-E-204-01: ASTRO Based Journals

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given dozens of competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Radiology, Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. Senior members of the editorial board for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; open access policies, the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. Other journals will be discussed as well. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the quality and impact of the paper and the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase quality, impact and chances of acceptance To help decipher which journal is appropriate for a given work A. Karellas, Research collaboration with Koning, Corporation.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-E-204-02: Journal of Medical Physics and JACMP

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given dozens of competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Radiology, Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. Senior members of the editorial board for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; open access policies, the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. Other journals will be discussed as well. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the quality and impact of the paper and the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase quality, impact and chances of acceptance To help decipher which journal is appropriate for a given work A. Karellas, Research collaboration with Koning, Corporation.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-E-204-03: Radiology and Other Imaging Journals

Research papers authored by Medical Physicists address a large spectrum of oncologic, imaging, or basic research problems; exploit a wide range of physical and engineering methodologies; and often describe the efforts of a multidisciplinary research team. Given dozens of competing journals accepting medical physics articles, it may not be clear to an individual author which journal is the best venue for disseminating their work to the scientific community. Relevant factors usually include the Journal’s audience and scientific impact, but also such factors as perceived acceptance rate, interest in their topic, and quality of service. The purpose of this symposium is to provide the medical physics community with an overview of scope, review processes, and article guidelines for the following journals: Radiology, Medical Physics, International Journal of Radiation Biology and Physics, Journal of Applied Clinical Medical Physics, and Practical Radiation Oncology. Senior members of the editorial board for each journal will provide details as to the journals review process, for example: single blind versus double blind reviews; open access policies, the hierarchy of the review process in terms of editorial board structure; the reality of acceptance, in terms of acceptance rate; and the types of research the journal prefers to publish. Other journals will be discussed as well. The goal is to provide for authors guidance before they begin to write their papers, not only for proper formatting, but also that the readership is appropriate for the particular paper, hopefully increasing the quality and impact of the paper and the likelihood of publication. Learning Objectives: To review each Journal’s submission and review process Guidance as to how to increase quality, impact and chances of acceptance To help decipher which journal is appropriate for a given work A. Karellas, Research collaboration with Koning, Corporation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fibre Diffraction Analysis of Skin Offers a Very Early and Extremely Accurate Diagnostic Test for Prostate Cancer

Double blind analysis of a batch of thirty skin tissue samples from potential prostate cancer sufferers correctly identified all “control” patients, patients with high and low grade prostate cancers, the presence of benign prostate hyperplasia (BPH), perineural invasions, and the one lymphatic invasion. Identification was by analysis of fibre diffraction patterns interpreted using a schema developed from observations in nine previous studies. The method, schema, and specific experiment results are reported in this paper, with some implications then drawn.

James, Veronica J.↗

Trivalent mosaic or consensus HIV immunogens prime humoral and broader cellular immune responses in adults

Mosaic and consensus HIV-1 immunogens provide two distinct approaches to elicit greater breadth of coverage against globally circulating HIV-1 and have shown improved immunologic breadth in nonhuman primate models. This double-blind randomized trial enrolled 105 healthy HIV-uninfected adults who received 3 doses of either a trivalent global mosaic, a group M consensus (CON-S), or a natural clade B (Nat-B) gp160 env DNA vaccine followed by 2 doses of a heterologous modified vaccinia Ankara–vectored HIV-1 vaccine or placebo. We performed prespecified blinded immunogenicity analyses at day 70 and day 238 after the first immunization. T cell responses to vaccine antigens and 5 heterologous Env variants were fully mapped. Env-specific CD4 + T cell responses were induced in 71% of the mosaic vaccine recipients versus 48% of the CON-S recipients and 48% of the natural Env recipients. The mean number of T cell epitopes recognized was 2.5 (95% CI, 1.2–4.2) for mosaic recipients, 1.6 (95% CI, 0.82–2.6) for CON-S recipients, and 1.1 (95% CI, 0.62–1.71) for Nat-B recipients. Mean breadth was significantly greater in the mosaic group than in the Nat-B group using overall (P = 0.014), prime-matched (P = 0.002), heterologous (P = 0.046), and boost-matched (P = 0.009) measures. Overall T cell breadth was largely due to Env-specific CD4 + T cell responses. Priming with a mosaic antigen significantly increased the number of epitopes recognized by Env-specific T cells and enabled more, albeit still limited, cross-recognition of heterologous variants. Mosaic and consensus immunogens are promising approaches to address global diversity of HIV-1.

60 APPLIED LIFE SCIENCES↗

Pivotal trial characteristics and types of endpoints used to support Food and Drug Administration rare disease drug approvals between 2013 and 2022

Background/aims Rare disease drug development faces unique challenges, such as genotypic and phenotypic heterogeneity within small patient populations and a lack of established outcome measures for conditions without previously successful drug development programs. These challenges complicate the process of selecting the appropriate trial endpoints and conducting clinical trials in rare diseases. In this descriptive study, we examined novel drug approvals for non-oncologic rare diseases by the U.S. Food and Drug Administration’s Center for Drug Evaluation and Research over the past decade and characterized key regulatory and trial design elements with a focus on the primary efficacy endpoint utilized as the basis of approval. Methods Using the Food and Drug Administration’s Data Analysis Search Host database, we identified novel new drug applications and biologics license applications with orphan drug designation that were approved between 2013 and 2022 for non-oncologic indications. From Food and Drug Administration review documents and other external databases, we examined characteristics of pivotal trials for the included drugs, such as therapeutic area, trial design, and type of primary efficacy endpoints. Differences in trial design elements associated with primary efficacy endpoint type were assessed such as randomization and blinding. Then, we summarized the primary efficacy endpoint types utilized in pivotal trials by therapeutic area, approval pathway, and whether the disease etiology is well defined. Results One hundred and seven drugs that met our inclusion criteria were approved between 2013 and 2022. Assessment of the 107 drug development programs identified 150 pivotal trials that were subsequently analyzed. The pivotal trials were mostly randomized (80%) and blinded (69.3%). Biomarkers (41.1%) and clinical outcomes (42.1%) were commonly utilized as primary efficacy endpoints. Analysis of the use of clinical trial design elements across trials that utilized biomarkers, clinical outcomes, or composite endpoints did not reveal statistically significant differences. The choice of primary efficacy endpoint varied by the drug’s therapeutic area, approval pathway, and whether the indicated disease etiology was well defined. For example, biomarkers were commonly selected as primary efficacy endpoints in hematology drug approvals (70.6%), whereas clinical outcomes were commonly selected in neurology drug approvals (69.6%). Further, if the disease etiology was well defined, biomarkers were more commonly used as primary efficacy endpoints in pivotal trials (44.7%) than if the disease etiology was not well defined (27.3%). Discussion In the past 10 years, numerous novel drugs have been approved to treat non-oncologic rare diseases in various therapeutic areas. To demonstrate their efficacy for regulatory approval, biomarkers and clinical outcomes were commonly utilized as primary efficacy endpoints. Biomarkers were not only frequently used as surrogate efficacy endpoints in accelerated approvals, but also in traditionally approved rare disease drugs. The choice of primary efficacy endpoints varied by therapeutic area, approval pathway, and understanding of disease etiology.

Hong, Kyungwan [Rare Diseases Team, Office of New ↗

Raw neutron scattering data for strain measurement of hydraulically loaded granite and marble samples in triaxial stress state

This entry contains raw data files from experiments performed on the Vulcan beamline at the Spallation Neutron Source at Oak Ridge National Laboratory using a pressure cell. Cylindrical granite and marble samples were subjected to confining pressures of either 0 psi or approximately 2500 psi and internal pressures of either 0 psi, 1500 psi or 2500 psi through a blind axial hole at the center of one end of the sample. The sample diameters were 1.5" and the sample lengths were 6". The blind hole was 0.25" in diameter and 3" deep. One set of experiments measured strains at points located circumferentially around the center of the sample with identical radii to determine if there was strain variability (this would not be expected for a homogeneous material based on the symmetry of loading). Another set of experiments measured load variation across the radius of the sample at a fixed axial and circumferential location. Raw neutron diffraction intensity files and experimental parameter descriptions are included.

15 GEOTHERMAL ENERGY↗

Ductile failure X-prize.

Fracture or tearing of ductile metals is a pervasive engineering concern, yet accurate prediction of the critical conditions of fracture remains elusive. Sandia National Laboratories has been developing and implementing several new modeling methodologies to address problems in fracture, including both new physical models and new numerical schemes. The present study provides a double-blind quantitative assessment of several computational capabilities including tearing parameters embedded in a conventional finite element code, localization elements, extended finite elements (XFEM), and peridynamics. For this assessment, each of four teams reported blind predictions for three challenge problems spanning crack initiation and crack propagation. After predictions had been reported, the predictions were compared to experimentally observed behavior. The metal alloys for these three problems were aluminum alloy 2024-T3 and precipitation hardened stainless steel PH13-8Mo H950. The predictive accuracies of the various methods are demonstrated, and the potential sources of error are discussed.

36 MATERIALS SCIENCE↗