Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam Simulations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Summer Student Internship: Experimental and modeling experiences

My internship at the Los Alamos National Laboratory has been an information-filled summer. Loren Espada-Castillo brought me into her project and helped mentor and guide me through the summer. The project that I was brought into was the process of shooting materials with electrons. The electron beam we used conducts a series of shots in which electrons are generated and then fired towards a target, the sample holder. The sample holder holds either a single sample or three samples. The sample holder also consists of multiple calorimeters surrounding the sample/s. The goal is to shoot certain materials and then analyze how they react to the exposure of the electrons. We shot titanium, which was meant to serve as a containment vessel window.

36 MATERIALS SCIENCE↗

Modeling Codes Used for LAMP

LAMP team is planning on using multiple computer codes as tools for modeling beam dynamics, electromagnetics, and plasma environment in ion sources. Below is a description of the computer tools we have been using or planning to use in the future. Most of the codes chosen for the LAMP project are capable to model most of the beam dynamics in LAMP. A judicious choice of the appropriate code to use will be based on speed and fidelity of the modeling with faster calculations produced by simplifying some features.

43 PARTICLE ACCELERATORS↗

Commissioning of Phase 1 of the LANL RFQ Test Stand - Beam Characterization

A series of numerical start-to-end simulations of Phase 1 of the 750 keV RFQ Test Stand which includes the ion source (H+ duoplasmatron), a 1-Solenoid LEBT, an emittance scan station and a Faraday cup were performed to find a mechanism for the characterization of the proton beam extracted from the duoplasmatron.

43 PARTICLE ACCELERATORS↗

Probing Dynamic Phase Changes in Electrochemical Systems with Cryogenic and in Situ Analytical Electron Microscopy (Final Technical Report)

In this project, we focus on the advancement of our newly developed, unique in situ and cryogenic analytical electron microscopy (AEM) techniques and the development of additional high-end capabilities to quantitatively elucidate the mechanisms of resistive state changes in solid-state electrochemical materials for non-volatile, neuromorphic memory. The objectives of the proposed research are (1) to characterize and elucidate the mechanisms by which electronic state changes occur in various solid-state devices to build guiding principles for electrochemically activated smart materials; (2) to advance our understanding of such mechanisms by coupling cryogenic and in situ techniques to control kinetics of the observed mechanisms while mitigating probe-induced damage; and (3) to utilize additional advanced techniques including electron-beam induced current and quantum mechanical simulations in order to identify the underlying fundamental science of such processes, including roles of defect formation and its effect on phase nucleation, as well as dynamics of these processes in the electrochemical systems at the nanometer scale.

25 ENERGY STORAGE↗

Toward the Frontiers of Particle Physics With the Muon $g\textrm{-}2$ Experiment

The Muon $g\textrm{-}2$ Experiment (E989) at Fermilab has a goal of measuring the muon anomaly ($a_\mu$) with unprecedented precision using positive muons. This measurement is motivated by the difference between the previous Brookhaven $a_\mu$ measurement and Standard Model prediction exceeding three standard deviations, which hints at the possibility of physics beyond the Standard Model. Muons are circulated in a storage ring, and the measurement requires a precise determination of the muon anomalous precession frequency (spin precession relative to momentum) from the resulting decay positron time and energy measurements collected with calorimeters. The average magnetic field seen by the muons needs to be known with high precision, and so the storage ring magnetic field is shimmed to be very uniform and is continually monitored with nuclear magnetic resonance (NMR) probes. Detailed Muon Campus beamline and muon storage ring simulations are also required for quantifying beam dynamics and spin-related systematic effects in the determination of the muon anomalous precession frequency, e.g. muon losses during the measurement window. At the time of the conference, the experiment has recently commenced Run-3, and the release of Run-1 physics results is planned for 2020.

43 PARTICLE ACCELERATORS↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Monte Carlo Simulations for Electron Energy Loss Mitigation in Real-Space Nanoimaging of Thick Biological Samples and Microchips

High-resolution imaging using Transmission Electron Microscopy (TEM) is essential for applications such as grain boundary analysis, microchip defect characterization, and biological imaging. However, TEM images are often compromised by electron energy spread and other factors. In TEM mode, where the objective and projector lenses are positioned downstream of the sample, electron–sample interactions cause energy loss, which adversely impacts image quality and resolution. This study introduces a simulation tool to estimate the electron energy loss spectrum (EELS) as a function of sample thickness, covering electron beam energies from 300 keV to 3 MeV. Leveraging recent advances in MeV-TEM/STEM technology, which includes a state-of-the-art electron source with 2-picometer emittance, an energy spread of 3 × 10 -5 , and optimized beam characteristics, we aim to minimize energy spread. By integrating EELS capabilities into the BNL Monte Carlo (MC) simulation code for thicker samples, we evaluate electron beam parameters to mitigate energy spread resulting from electron–sample interactions. Based on our simulations, we propose an experimental procedure for quantitively distinguishing between elastic and inelastic scattering. The findings will guide the selection of optimal beam settings, thereby enhancing resolution for nanoimaging of thick biological samples and microchips.

36 MATERIALS SCIENCE↗

Atomistic simulations for investigation of substrate effects on lipid in-source fragmentation in secondary ion mass spectrometry

In beam-based ionization methods, the substrate plays an important role on the desorption mechanism of molecules from surfaces. Both the specific orientation that a molecule adopts at a surface and the strength of the molecule-surface interaction can greatly influence desorption processes, which in turn will affect the ion yield and the degree of in-source fragmentation of a molecule. In the beam-based method of secondary ion mass spectrometry (SIMS), in-source fragmentation can be significant and molecule specific due to the hard ionization method of using a primary ion beam for molecule desorption. To investigate the role of the substrate on orientation and in-source fragmentation, we have used atomistic simulations—molecular dynamics in combination with density functional theory calculations—to explore the desorption of a sphingolipid (palmitoylsphingomyelin) from a model surface (gold). We then compare SIMS data from this model system to our modeling findings. Using this approach, we found that the combined adsorption and binding energy of certain bonds associated with the headgroup fragments (C3H8N+, C5H12N+, C5H14NO+, and C5H15PNO4+) was a good predictor for fragment intensities (as indicated by relative ion yields). This is the first example where atomistic simulations have been applied in beam-based ionization of lipids, and it presents a new approach to study biointerfacial lipid ordering effects on SIMS imaging.

59 BASIC BIOLOGICAL SCIENCES↗

Symplectic Particle Tracking in a Thick Nonlinear McMillan Lens for the Fermilab Integrable Optics Test Accelerator (IOTA)

The McMillan system is a novel method to increase the tune spread of a beam without decreasing its dynamic aperture due to the systems integrability. While the ideal system is based on an infinitely thin kick, the physical design requires a thick electron lens, including a solenoid. Particle transport through the lens is difficult to simulate due to the nature of the force on the circulating beam. This paper demonstrates accurate simulation of a thick McMillan lens in a solenoid using symplectic integrators derived from Yoshidas method.

43 PARTICLE ACCELERATORS↗

Modeling of emittance growth due to Coulomb collisions in plasma-based accelerators

Coulomb collisions with background plasma are one source of emittance degradation in plasma accelerators. This work shows that the emittance growth due to Coulomb collisions can be correctly captured in particle-in-cell simulations, with a proper Monte Carlo binary collision module. The theory of the emittance growth due to Coulomb collisions is extended from a monoenergetic matched beam to a mismatched beam with energy spread and is compared with simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Facile Tensile Testing Platform for In Situ Transmission Electron Microscopy of Nanomaterials

In situ tensile testing using transmission electron microscopy (TEM) is a powerful technique to probe structure-property relationships of materials at the atomic scale. In this work, a facile tensile testing platform for in situ characterization of materials inside a transmission electron microscope is demonstrated. The platform consists of: 1) a commercially available, flexible, electron-transparent substrate (e.g., TEM grid) integrated with a conventional tensile testing holder, and 2) a finite element simulation providing quantification of specimen-applied strain. The flexible substrate (carbon support film of the TEM grid) mitigates strain concentrations usually found in free-standing films and enables in situ straining experiments to be performed on materials that cannot undergo localized thinning or focused ion beam lift-out. The finite element simulation enables direct correlation of holder displacement with sample strain, providing upper and lower bounds of expected strain across the substrate. The tensile testing platform is validated for three disparate material systems: sputtered gold-palladium, few-layer transferred tungsten disulfide, and electrodeposited lithium, by measuring lattice strain from experimentally recorded electron diffraction data. The results show good agreement between experiment and simulation, providing confidence in the ability to transfer strain from holder to sample and relate TEM crystal structural observations with material mechanical properties.

2D materials↗

Performance of the Fermilab Linac Injector

The Fermilab Linac injection line consists of a 35 keV magnetron-type H- ion source, two-solenoid Low Energy Beam Transport (LEBT), 201 MHz 4-rod 750 keV Radio Frequency Quadrupole (RFQ), and a Medium Energy Transport (MEBT) containing 4 quadrupoles and a bunching cavity. The injector delivers 25 mA, 48 s pulses to drift-tube Linac at a repetition rate of 15Hz. The transmission efficiency has been lower than expected since commissioning. Recent beam current measurements suggest that the beam is primarily lost upstream of the RFQ exit. Numerical simulations indicate that ions passing through the non-linear field region of the solenoids could produce a beam with an increased emittance resulting in up to 50 % of the LEBT beam current failing to meet the RFQ acceptance. An aperture restriction was installed upstream of the first solenoid to remove these ions. This report describes the results of measurements and simulations as well as the LEBT tuning.

Jones, Daniel C.↗

Performance of the Fermilab Linac Injector

The Fermilab Linac injection line consists of a 35 keV magnetron-type H- ion source, two-solenoid Low Energy Beam Transport (LEBT), 201 MHz 4-rod 750 keV Radio Frequency Quadrupole (RFQ), and a Medium Energy Transport (MEBT) containing 4 quadrupoles and a bunching cavity. The injector delivers 25 mA, 48 s pulses to drift-tube Linac at a repetition rate of 15Hz. The transmission efficiency has been lower than expected since commissioning. Recent beam current measurements suggest that the beam is primarily lost upstream of the RFQ exit. Numerical simulations indicate that ions passing through the non-linear field region of the solenoids could produce a beam with an increased emittance resulting in up to 50 % of the LEBT beam current failing to meet the RFQ acceptance. An aperture restriction was installed upstream of the first solenoid to remove these ions. This report describes the results of measurements and simulations as well as the LEBT tuning.

Jones, Daniel C.↗

Performance of the Fermilab Linac Injector

The Fermilab Linac injection line consists of a 35 keV magnetron-type H\textsuperscript{-} ion source, two-solenoid Low Energy Beam Transport (LEBT), 201 MHz 4-rod 750 keV Radio Frequency Quadrupole (RFQ), and a Medium Energy Transport (MEBT) containing 4 quadrupoles and a bunching cavity. The injector delivers 25 mA, 48 µs pulses to the drift-tube Linac at a repetition rate of 15Hz. The transmission efficiency of the injector has been lower than expected since commissioning. Recent beam current measurements suggest that the beam is primarily lost upstream of the RFQ exit. Numerical simulations indicate that ions passing through the non-linear field region of the solenoids could produce a beam with an increased emittance resulting in up to 50\% of the LEBT beam current failing to meet the RFQ acceptance. An aperture restriction was installed upstream of the first solenoid to remove these ions. This report describes the results of measurements and simulations as well as the LEBT tuning.

43 PARTICLE ACCELERATORS↗

Optimize Electron Beam Energy toward In Situ Imaging of Thick Frozen Bio-Samples with Nanometer Resolution Using MeV-STEM

To optimize electron energy for in situ imaging of large biological samples up to 10 μm in thickness with nanoscale resolutions, we implemented an analytical model based on elastic and inelastic characteristic angles. This model has been benchmarked by Monte Carlo simulations and can be used to predict the transverse beam size broadening as a function of electron energy while the probe beam traverses through the sample. As a result, the optimal choice of the electron beam energy can be realized. In addition, the impact of the dose-limited resolution was analysed. While the sample thickness is less than 10 μm, there exists an optimal electron beam energy below 10 MeV regarding a specific sample thickness. However, for samples thicker than 10 μm, the optimal beam energy is 10 MeV or higher depending on the sample thickness, and the ultimate resolution could become worse with the increase in the sample thickness. Moreover, a MeV-STEM column based on a two-stage lens system can be applied to reduce the beam size from one micron at aperture to one nanometre at the sample with the energy tuning range from 3 to 10 MeV. In conjunction with the state-of-the-art ultralow emittance electron source that we recently implemented, the maximum size of an electron beam when it traverses through an up to 10 μm thick bio-sample can be kept less than 10 nm . This is a critical step toward the in situ imaging of large, thick biological samples with nanometer resolution.

36 MATERIALS SCIENCE↗

Investigation of the Role of the Role of Nuclear Physics in Heavy Element Nucleosynthesis, through the Study of Key Reactions, and the Improvement of Theoretical Reaction Rates (Final Report)

Neutrino-driven winds in core-collapse supernovae have been identified as a possible site for the production of elements heavier than iron. Traditionally, these neutrino-driven winds have been proposed as the site of the main r-process. Recent simulations fail to reproduce the conditions required for the main r-process. while they remain a promising site for producing the lightest elements beyond iron, e.g., Sr, Y, and Zr through the νp process. The efficiency of the νp process depends on the hydrodynamical conditions, the electron fraction (which is related to the neutrino properties), and the nuclear reactions on many short-lived nuclei with limited (if at all) experimental information. The reaction rates on these nuclei are based on theoretical predictions using the Hauser-Feshbach model. Recent sensitivity studies have highlighted the importance of neutron-induced reactions on these nuclei along the νp process path. This work aimed to experimentally constrain reaction rates that are known to play a key role in the neutrino-p process nucleosynthesis. A secondary subsequently-added objective was to start the implementation of techniques that improve the description of nuclear properties in the Hauser-Feshbach model by extending the microscopic nuclear level density description offered via the shell model to high excitation energies without using experiment-based renormalizations. The main objective of this work was the experimental constraint of the 56 Ni(n,p) 56 Co reaction rate via a measurement of the inverse reaction 56 Co(p,n) 56 Ni at the National Superconducting Cyclotron Laboratory (NSCL) and later the Facility for Rare Isotope Beams (FRIB). This reaction is considered the key one for determining the yields possible by the neutrino-p process. A technique for this type of measurement in inverse kinematics at low energies did not exist before this work. The work also had two secondary objectives. First, to contribute to efforts to measure the same reaction in direct kinematics using a radioactive target at Los Alamos National Laboratory (LANL), and second, to advance work to implement shell-model-deduced microscopic level densities in Hauser-Feshbach calculations. The project has resulted in the development of the first technique to perform (p,n) cross-section measurements in relevant-for-astrophysics low energies in inverse kinematics using a magnetic spectrometer or separator, and neutron detectors for neutron tagging. It has also resulted in the precise measurement of the cross-section of the 40 Ar(p,n) 40 K reaction in a proof-of-principle experiment realized by using a beam-line quadrupole of the ReA3 accelerator of NSCL/FRIB. As part of this project the technique was successfully adapted to make use of the superior acceptance of the Separator for Capture Reactions (SECAR) at FRIB. In this project, the required experimental setup simulations and beam optics were developed and tested with the measurement of the 58 Fe(p,n) 58 Cu reaction cross-section. Additionally, this project contributed with simulation work to the development of a technique to measure (n,p) reactions with radioactive targets at LANL, and which resulted in the measurement of the key 56 Ni(n,p) 56 Co reaction cross-section at neutron energies above ≈1 MeV. Last, the project initiated work in the development of shell model based level densities using the moments method.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗