Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BNL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Large scale accelerator production of 225Ac: Effective cross sections for 78–192 MeV protons incident on 232Th targets

Actinium-225 and 213 Bi have been used successfully in targeted alpha therapy (TAT) in preclinical and clinical research. This paper is a continuation of research activities aiming to expand the availability of 225 Ac. The high energy proton spallation reaction on natural thorium metal target has been utilized to produce millicurie quantities of 225 Ac. The results of sixteen irradiation experiments of Th metal at beam energies between 78 and 200 MeV are summarized in this work. Irradiations have been conducted at Brookhaven National Laboratory (BNL) and Los Alamos National Laboratory (LANL), while target dissolution and processing was carried out at Oak Ridge National Laboratory (ORNL). Excitation functions for actinium and thorium isotopes as well as for some of the fission products are presented. The cross sections for production of 225 Ac range from 3.6 to 16.7 mb in the incident proton energy range of 78 to 192 MeV. Based on these data, production of Curie quantities of 225Ac is possible by irradiating a 5.0 g cm -2232 Th target for 10 days in either BNL or LANL proton irradiation facilities.

139Ce↗

Nuclear Data Sheets for A=217

The evaluated spectroscopic data are presented in this paper for 12 known nuclides with A=217 (Tl, Pb, Bi, Po, At, Rn, Fr, Ra, Ac, Th, Pa, U). For 217Tl, 217Pb, 217Pa, and 217U nuclei, only information on the ground state is available. Levels in 217 Bi are known only from isomer decay following fragmentation reaction and those in 217 At and 217 Rn only from the α decay of 221 Fr and 221 Ra, respectively. High spin levels in 217 Ra are mainly from 1987SuZY and 2011MuZZ which are a lab report and thesis, respectively. Due to differences between these studies, further experimental study is needed to firmly establish the level scheme. This evaluation was carried out as part of a joint IAEA-ICTP workshop for Nuclear Structure and Decay Data, organized and hosted by the IAEA, Vienna and ICTP, Trieste, Aug 22 to Sept 2 2016. The evaluation work was coordinated by E.A. McCutchan (BNL). Finally, this work supersedes the previous previous A=217 evaluation (2003Ak06) by Y.A. Akovali.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Muon g-2 experiment at Fermilab

The upcoming Fermilab E989 experiment will measure the muon anomalous magnetic moment aμ. This measurement is motivated by the previous measurement performed in 2001 by the BNL E821 experiment that reported a 3-4 standard deviation discrepancy between the measured value and the Standard Model prediction. The new measurement at Fermilab aims to improve the precision by a factor of four reducing the total uncertainty from 540 parts per billion (BNL E821) to 140 parts per billion (Fermilab E989). This paper gives the status of the experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Muon G − 2 Experiment

The Muon g−2 Experiment at Fermi National Accelerator Laboratory was designed to measure the anomalous magnetic moment of the muon, aµ, with a precision of 140 parts-per-billion; a four-fold improvement over the former BNL measurement. The Fermilab experiment was motivated by the about 3.5 standard deviation between the experiment and the Standard Model calculation of aµ which could be a hint of new physics. The experiment at Fermilab relies on the well-established storage ring technique using magic momentum muons but employs new detector systems and a higher rate of muons per injection cycle to achieve the significant improvement in precision. A first result from the Run-1 data taking period has achieved an uncertainty of 0.46 parts-per-million and confirmed the BNL discrepancy, further increasing the tension with the Standard Model to 4.2 σ. The experimental technique, key aspects of the measurement, and the data analysis of Run-1 will be summarized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Present Status And Future Prospects Of Polarized Ion Sources

Recent progress in polarized ion sources development is reviewed. New techniques for production of polarized H{sup -} ion (proton), D{sup -} (D{sup +}) and {sup 3}He{sup ++} ion beams are discussed. Feasibility studies of these techniques are in progress at BNL and other laboratories. Polarized deuteron beams will be required for the polarization program at the Dubna Nuclotron and at the deuteron Electric Dipole Moment experiment at BNL. Experiments with polarized {sup 3}He{sup ++} ion beams are a part of the experimental program at the future Electron Ion Collider.

43 PARTICLE ACCELERATORS↗

The New Maia Detector System: Methods For High Definition Trace Element Imaging Of Natural Material

Motivated by the need for megapixel high definition trace element imaging to capture intricate detail in natural material, together with faster acquisition and improved counting statistics in elemental imaging, a large energy-dispersive detector array called Maia has been developed by CSIRO and BNL for SXRF imaging on the XFM beamline at the Australian Synchrotron. A 96 detector prototype demonstrated the capacity of the system for real-time deconvolution of complex spectral data using an embedded implementation of the Dynamic Analysis method and acquiring highly detailed images up to 77 M pixels spanning large areas of complex mineral sample sections.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation study of CO 2 laser-plasma interactions and self-modulated wakefield acceleration

3D numerical simulations of the interaction of a powerful CO 2 laser with hydrogen jets demonstrating the role of ionization on the characteristics of induced wakes are presented. Simulations using SPACE, a parallel relativistic Particle-in-Cell code, are performed in support of the plasma wakefield accelerator experiments being conducted at the Brookhaven National Laboratory (BNL) Accelerator Test Facility (ATF). A novelty of the SPACE code is its set of efficient atomic physics algorithms that compute ionization and recombination rates on the grid and transfer them to particles. The influence of ionization on the spectrum of pump laser has been studied for a range of gas densities.Simulations reproduce both Stokes and anti-Stokes shifts in the spectrum of pump laser, similar to those observed in experiments in the spectrum of probe. A good agreement has been achieved with the experiments on the effect of variation in gas density on Stokes/anti-Stokes intensity. In addition, self-injection and trapping of electrons into the self-modulated wakes has been observed and analyzed. Here, the experimentally validated code SPACE will be used for predictive simulations to guide future experiments at BNL ATF.

97 MATHEMATICS AND COMPUTING↗

Development of highly efficient NEG pumping system for EBIS

Ultrahigh vacuum inside the ion trap volume is crucial for stable and reliable operation of an Electron Beam Ion Source (EBIS). We have developed and tested a compact linear pumping system based on the ZAO Non-Evaporable Getter (NEG) module with high pumping speed and enhanced sorption capacity for all active gases. Due to its minimal transverse dimensions, the system can be mounted adjacent to the ion trap inside a superconducting solenoid bore and will provide a pumping speed of the order of 1000 l/s for all active gases in that area. An externally supplied current (100 A DC) is used to heat the ZAO NEG up to 650 °C for more than 1 h, which is required for pump activation and/or reactivation cycles. The pumping system is being developed for use in the Extended EBIS Upgrade which is presently in progress at BNL. In conclusion, the design of the system and results of multiple tests are presented and discussed.

43 PARTICLE ACCELERATORS↗

Development of the high energy engineering X-ray (HEX) superconducting wiggler, magnetic measurement, installation, and commissioning

The High energy Engineering X-ray (HEX) diffraction beamline at the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Lab (BNL) is the first high-energy beamline capable of reaching 200 keV for a monochromatic beam. With the 3 GeV electron beam energy for the NSLS-II ring, only the superconducting wiggler (SCW) producing greater than 4 T peak field can cover these ranges with a sufficient number of photons. The 1.2 m-long HEX-SCW has a period length of 70 mm and a field strength on-axis of 4.3 T. It utilizes no liquid helium, and the vertical aperture size of the electron beam vacuum chamber is 8 mm. Unlike regular undulators/wigglers, there is no standard configuration for the magnetic measurement system for superconducting insertion devices. The NSLS-II Insertion Devices group has developed, in collaboration with the vacuum group, a novel in-vacuum Hall mapper with a 1.75 m in-vacuum linear motor and an in-vacuum flip coil system utilizing many commercial-off-the-shelf products. The measurements were conducted at the BNL, and the device was installed in the ring and commissioned. Here, this paper provides a description of the SCW and its magnetic measurement systems, as well as a brief account of the installation and commissioning efforts.

36 MATERIALS SCIENCE↗

Laser ion source activities at Brookhaven National Laboratory

In Brookhaven National Laboratory (BNL), we have been developing laser ion sources for diverse accelerators. Tabletop Nd:YAG lasers with up to several Joules of energy are mainly used to create ablation plasmas for stable operations. The obtained charge states depend on laser power density and target species. Two types of ion extraction schemes, Direct Plasma Injection Scheme (DPIS) and conventional static extraction, are used depending on application. We optimized and select a suitable laser irradiation condition and a beam extraction scheme to meet the requirement of the following accelerator system. We have demonstrated to accelerate more than 5 x 10 10 of C 6+ ions using the DPIS. We successfully commissioned low charge ion beam provider to the user facilities in BNL. As a result, to achieve higher current, higher charge state and lower emittance, further studies will continue.

43 PARTICLE ACCELERATORS↗

High precision magnetic field measurement and mapping of the LEReC 180 degree bending magnet using very low field NMR with hall combined probe (140 - 350 gauss)

The Relativistic Heavy Ion Collider (RHIC) at BNL are using the Low Energy RHIC Electron Cooling (LEReC) to conduct experiments that search for the quantum chromodynamic (QCD) critical point. The first ever electron cooling based on the RF acceleration of electron beams was experimentally demonstrated on April 5, 2019 at LEReC at BNL. The first critical step in obtaining successful 3D non-magnetized cooling of the Au ion bunches in the RHIC cooling section was matching the electron beam energy with a relative error less than 5*10 -4 to the ion beam energy. Part of the LEReC beamline is a dipole magnet that bends the electron beam 180 degree. One of the most outstanding measurement challenges is that the dipole field is so low (≈200 G). Most of the existing NMR probes can only measure fields >400 G. Lower signal-to-noise ratio at low fields is requires the use of larger sample volumes. Working with CAYLAR, a NMR probe has been redesigned and optimized for these low field measurements with high resolution. We report the methods, challenges, and results for extensive magnetic field mappings of the 180 dipole magnet. A combination of NMR and Hall sensors has been successfully implemented to measure uniform field regimes inside the magnet center area and non-uniform field regimes at the magnet ends. Detailed measurement and mapping have been performed at five radii and five heights along the beam trajectory. Meanwhile a finite element magnetic modeling simulation of the magnet using Opera software has been performed. The calculated and measured data are compared, and the calculated data is good reference for measured data over long length mapping from magnet edge to center. The measured magnetic measurement data is directly useful for beam instrumentation, diagnostics and operation.

Magnetic Field Measurement↗

Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations

High brightness, negative hydrogen ion sources are used extensively in scientific facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Several well-known facilities now have considerable experience with operating a variety of sources such as RF-, filament-, magnetron- and Penning-type H- ion sources. These facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly on cyclotrons and, most recently, the CERN-LINAC-1 injector. This report first summarizes the current performance of these ion sources in routine, daily operations with attention toward source service-periods and availability metrics. Sustainability issues encountered at each facility are also reported and categorized to identify areas of common concern and key issues. Recent ion source improvements to address these issues are also discussed as well as plans for meeting future facility upgrade requirements.

Welton, Robert F.↗

Performance of laser ion source LION operated at Brookhaven National Laboratory

LION is a laser ion source that has been in operation at Brookhaven National Laboratory (BNL) to provide heavy ions for NASA Space Radiation Laboratory (NSRL) and Relativistic Heavy Ion Collider (RHIC). It is the first laser ion source to supply stable ion beams for a long-term operation for users at a large accelerator facility in the world. LION is located at the upstream end of the heavy ion accelerator complex at BNL and supplies singly charged ion beams of various ion species. LION has been in operation since 2014 and is planned to be upgraded in 2024. This paper summarizes the operational performance achieved by LION.

43 PARTICLE ACCELERATORS↗

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The Muon g - 2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment, a μ , of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, ω α , of muons stored in a magnetic field of 1.45 T, and a precise measurement of that magnetic field in terms of the shielded proton Larmor frequency, ω' ρ . The measurement of ω' ρ with a total systematic uncertainty of 70 parts-perbillion involves a combination of various nuclear magnetic resonance (NMR) probes. There are 378 probes mounted in fixed locations that constantly monitor field drifts. A water-based, cylindrical calibration probe provides the calibration in terms of the shielded proton Larmor frequency. A crucial element for the multi-step measurement of ω' ρ is the regular mapping of the magnetic field over the muon storage region. The former experiment at Brookhaven National Laboratory (BNL) employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include the addition of 16-bit, 1 MSPS digitization of the NMR signals, which replaced the hardware-implemented zero-crossing counting of the system at Brookhaven. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. To sustain the higher data rates, a new communication scheme with time-division multiplexing was implemented to separate the important NMR reference clock from the data communication in order to reach the specifications for the accuracy and stability of the reference clock. A new barcode reader provides more precise azimuthal position determination during the measurement and calibration. While the mechanical systems that move the field mapper inside the storage ring have been mostly refurbished from BNL, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first three data taking periods of the experiment at Fermilab. Finally, this article will provide the details of the upgrades of the field mapper and its performance.

47 OTHER INSTRUMENTATION↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Nucleon-gold collisions at 200A GeV using tagged d + Au interactions in the PHOBOS detector

Forward calorimetry in the PHOBOS detector has been used to study charged hadron production in d+Au, p+Au, and n+Au collisions at √s NN =200GeV. The forward proton calorimeter detectors are described and a procedure for determining collision centrality with these detectors is detailed. The deposition of energy by deuteron spectator nucleons in the forward calorimeters is used to identify p+Au and n+Au collisions in the data. A weighted combination of the yield of p+Au and n+Au is constructed to build a reference for Au+Au collisions that better matches the isospin composition of the gold nucleus. The p T and centrality dependence of the yield of this improved reference system is found to match that of d+Au. The shape of the charged-particle transverse momentum distribution is observed to extrapolate smoothly from p+p¯ to central d+Au as a function of the charged-particle pseudorapidity density. The asymmetry of positively and negatively charged hadron production in p+Au is compared to that of n+Au. No significant asymmetry is observed at midrapidity. In conclusion, these studies augment recent results from experiments at the CERN Large Hadron Collider and BNL Relativistic Heavy Ion Collider facilities to give a more complete description of particle production in p+A and d+A collisions, essential for the understanding the medium produced in high-energy nucleus-nucleus collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Next-to-leading order QCD corrections to heavy quark correlations in longitudinally polarized hadron-hadron collisions

We present a comprehensive phenomenological study of heavy flavor distributions and correlations in longitudinally polarized proton-proton collisions at BNL-RHIC. All results are obtained with a flexible parton-level Monte Carlo program at next-to-leading order accuracy and include the fragmentation into heavy mesons, their subsequent semileptonic decays, and experimental cuts. Next-to-leading order QCD corrections are found to be significant for both cross sections and double-spin asymmetries. The sensitivity of heavy flavor measurements at BNL-RHIC to the gluon polarization of the nucleon is assessed. Electron-muon and muon-muon correlations turn out to be the most promising observables. Theoretical uncertainties are estimated by varying renormalization and factorization scales, heavy quark masses, and fragmentation parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗