Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Comparison of Patient Dose in Two-Dimensional Carotid Arteriography and Three-Dimensional Rotational Angiography

Background and Purpose. It is known that interventional neuroradiology (IN) involves high radiation dose to both patients and staff even if performed by trained operators using modern fluoroscopic X-ray equipment and dose-reducing technology. Therefore, every new technology or imaging tool introduced, such as three-dimensional rotational angiography (3D RA), should be evaluated in terms of radiation dose. 3D RA requires a series with a large number of images in comparison with 2D angiography and it is sometimes considered a high-dose IN procedure. The literature is scarce on the 3D RA radiation dose and in particular there are no data on carotid arteriography (CA). The aim of this study was to investigate patient dose differences between 2D and 3D CA. Methods. The study included 35 patients undergoing 2D CA in hospital 1 and 25 patients undergoing 3D CA in hospital 2. Patient technical data collection included information on the kerma area product (KAP), fluoroscopy time (T), total number of series (S), and total number of acquired images (F). Results. Median KAP was 112 Gy cm{sup 2} and 41 Gy cm{sup 2} for hospitals 1 and 2, respectively, median T was 8.2 min and 5.1 min, median S was 13 and 4, and median F was 247 and 242. Entrance surface air-kerma rate, as measured in 'medium' fluoroscopy mode measured in 2D acquisition using a 20 cm phantom of polymethylmethacrylate, was 17.3 mGy/min for hospital 1 and 9.2 mGy/min for hospital 2. Conclusion. 3D CA allows a substantial reduction in patient radiation dose compared with 2D CA, while providing the necessary diagnostic information.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Thrombin Injection of a Femoral Artery Pseudoaneurysm with Simultaneous Venous Balloon Occlusion of a Communicating Arteriovenous Fistula

An 82-year-old woman developed acute occlusion of her right coronary artery. She underwent percutaneous coronary stent placement and aortic balloon pump installation. In the postprocedural period, she developed a common femoral artery pseudoaneurysm (PSA) that communicated with the common femoral vein via an arteriovenous fistula (AVF). After unsuccessful ultrasound-guided compression, ultrasound-guided thrombin injection of the PSA was performed, with simultaneous balloon occlusion of the common femoral vein at the level of the AVF. There was complete thrombosis of the PSA and AVF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of AVF after Hair Transplantation

Arteriovenous fistula (AVF) of the scalp is a very rare complication of hair transplantation. Only 9 cases have been reported in nearly half a century. The diagnosis is clinical but angiography is necessary for defining the angioarchitecture of the lesion. Due to technical developments, endovascular embolization has become the primary treatment for AVF of the scalp.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reperfusion Hemorrhage Following Superior Mesenteric Artery Stenting

Percutaneous transluminal angioplasty and stent placement is now an established treatment option for chronic mesenteric ischemia and is associated with low mortality and morbidity rates. We present a case of reperfusion hemorrhage complicating endovascular repair of superior mesenteric artery stenosis. Although a recognized complication following repair of carotid stenosis, hemorrhage has not previously been reported following mesenteric endovascular reperfusion. We describe both spontaneous cessation of bleeding and treatment with coil embolization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Treatment of a Ruptured Para-Anastomotic Aneurysm of the Abdominal Aorta

We report a case of a ruptured para-anastomotic aortic aneurysm treated with implantation of a bifurcated stent-graft. A 72-year-old patient, who had undergone aortobifemoral bypass for aortoiliac occlusive disease 16 years ago, presented with a ruptured para-anastomotic aortic aneurysm. A bifurcated stent-graft was successfully deployed into the old bifurcated graft. This is the first report of a bifurcated stent-graft being placed through an 'end-to-side' anastomosed old aortobifemoral graft. Endovascular treatment of ruptured para-anastomotic aortic aneurysms can be accomplished successfully, avoiding open surgery which is associated with increased mortality and morbidity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Management of Chronic Type B Dissecting Aortic Aneurysm Utilizing Aortic and Renal Stents

Over the last 10 years endovascular stent-graft placement has been increasingly used to treat complicated acute Type B thoracic aortic dissections. While studies have demonstrated the use of additional aortic stent-grafts to treat continued false lumen perfusion and case reports have detailed the use of renal artery stents to treat renal ischemia related to aortic dissection, to our knowledge the adjuvant use of renal artery stents to reduce false lumen perfusion has not been reported. We present the case of a 72-year-old male who had previously undergone endovascular repair of a complicated Type B thoracic aortic dissection and presented with an expanding false lumen in the peridiaphragmatic aorta despite coverage of the entire thoracic aorta. This was treated by closure of a right renal fenestration using a renal stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of a Balloon and N-Butyl-2-Cyanoacrylate for Treatment of Arteriovenous Fistula

We report a patient who developed a large arteriovenous fistula in right lower extremity after gunshot injury. Because other endovascular methods failed, the patient was successfully treated with concomitant use of detachable latex balloon and N-butyl-2-cyanoacrylate (NBCA). The combination of detachable balloon and NBCA can be effectively used for endovascular treatment of peripheral arteriovenous fistulas in selected cases when effective embolization could not be achieved with other embolizing agents or their various combinations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Catheter-Directed Thrombolysis of Inferior Vena Cava Thrombosis in a 13-Day-Old Neonate and Review of Literature

Complete inferior vena cava thrombosis (IVC) in neonates is uncommon, but may cause significant morbidity. A 13-day-old neonate suffered IVC thrombosis secondary to antithrombin III deficiency, possibly contributed to by a mutation in the methyl tetrahydrofolate reductase gene. Catheter-directed thrombolysis (CDT) with recombinant tissue plasminogen activator (rt-PA, Alteplase) was used successfully to treat extensive venous thrombosis in this neonate without complications. We also review the literature on CDT for treatment of IVC thrombosis in critically ill neonates and infants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Renal Artery Stump to Inferior Vena Cava Fistula: Unusual Clinical Presentation and Transcatheter Embolization with the Amplatzer Vascular Plug

Fistulous communication between the renal artery stump and inferior vena cava following nephrectomy is rare. We describe the case of a 52-year-old man with a fistula detected on investigation for hemolytic anemia in the postoperative period. The patient had had a nephrectomy performed 2 weeks prior to presentation for blunt abdominal trauma. The fistula was successfully occluded percutaneously using an Amplatzer vascular plug. The patient recovered completely and was discharged 2 weeks later.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Injection of Lidocaine Within the Carotid Body Area in Carotid Artery Stenting: An 'Old-New' Technique

Severe bradycardia is a common untoward effect during balloon angioplasty when performing carotid artery stenting. Therefore atropine injection even before dilatation and the presence of an anesthesiologist are advocated in all patients. In the surgical literature, injection of a local anesthetic agent into the carotid sinus before carotid endarterectomy was performed in an attempt to ameliorate perioperative hemodynamic instability. This study was undertaken to test the hypothesis that percutaneous infiltration of the carotid sinus with local anesthetic immediately before balloon dilatation reduces bradycardia and ameliorates the need for atropine injection or the presence of an anesthesiologist. Infiltration of the carotid sinus with 5 ml of 1% lidocaine, 3 min before dilatation, was performed in 30 consecutive patients. No one exhibited any significant rhythm change that required atropine injection. The anesthesiologist did not face any hemodynamic instability during the carotid artery stenting procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systemic Artery to Pulmonary Artery Fistula Associated with Mitral Regurgitation: Successful Treatment with Endovascular Embolization

We present the case of a 60-year-old woman with symptomatic mitral regurgitation caused by a left-to-right shunt via anastomoses consisting of microfistulae, most likely of inflammatory origin, between the right subclavian artery and the right pulmonary artery. The three arteries responsible for fistulous formation, including the internal mammary, thyrocervical, and lateral thoracic arteries, were successfully occluded by transcatheter embolization using superabsorbent polymer microsphere (SAP-MS) particles combined with metallic coils. No complications have been identified following treatment with SAP-MS particles. This approach significantly reduced the patient's mitral regurgitation and she has remained asymptomatic for more than 4 years.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Restenosis of the CYPHER-Select, TAXUS-Express, and Polyzene-F Nanocoated Cobalt-Chromium Stents in the Minipig Coronary Artery Model

PurposeTo date no direct experimental comparison between the CYPHER-Select and TAXUS-Express stents is available. Therefore, we investigated late in-stent stenosis, thrombogenicity, and inflammation, comparing the CYPHER-Select, TAXUS-Express, and custom-made cobalt chromium Polyzene-F nanocoated stents (CCPS) in the minipig coronary artery model.MethodsThe three stent types were implanted in the right coronary artery of 30 minipigs. The primary endpoint was in-stent stenosis assessed by quantitative angiography and microscopy. Secondary endpoints were inflammation and thrombogenicity evaluated by scores for inflammation and immunoreactivity (C-reactive protein and transforming growth factor beta). Follow-up was at 4 and 12 weeks.ResultsStent placement was successful in all animals; no thrombus deposition occurred. Quantitative angiography did not depict statistically significant differences between the three stent types after 4 and 12 weeks. Quantitative microscopy at 4 weeks showed a statistically significant thicker neointima (p = 0.0431) for the CYPHER (105.034 {+-} 62.52 {mu}m) versus the TAXUS (74.864 {+-} 66.03 {mu}m) and versus the CCPS (63.542 {+-} 39.57 {mu}m). At 12 weeks there were no statistically significant differences. Inflammation scores at 4 weeks were significantly lower for the CCPS and CYPHER compared with the TAXUS stent (p = 0.0431). After 12 weeks statistical significance was only found for the CYPHER versus the TAXUS stent (p = 0.0431). The semiquantitative immunoreactivity scores for C-reactive protein and transforming growth factor beta showed no statistically significant differences between the three stent types after 4 and 12 weeks.ConclusionsThe CCPS provided effective control of late in-stent stenosis and thrombogenicity in this porcine model compared with the two drug-eluting stents. Its low inflammation score underscores its noninflammatory potential and might explain its equivalence to the two DES.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Therapy of Ruptured Abdominal Aortic Aneurysm: Mid- and Long-Term Results

As an alternative to open aneurysm repair, emergency endovascular aortic repair (EVAR) has emerged as a promising technique for ruptured abdominal aortic aneurysm (rAAA) within the last decade. The aim of this retrospective study is to present early and late outcomes of patients treated with EVAR for rAAA. Twenty-two patients (5 women, 17 men; mean age, 74 years) underwent EVAR for rAAA between November 2000 and April 2006. Diagnostic multislice computed tomography angiography was performed prior to stent-graft repair to evaluate anatomical characteristics and for follow-up examinations. Periprocedural patient characteristics and technical settings were evaluated. Mortality rates, hospital stay, and early and late complications, within a mean follow-up time of 744 {+-} 480 days, were also assessed. Eight of 22 patients were hemodynamically unstable at admission. Stent-graft insertion was successful in all patients. The total early complication rate was 54%, resulting in a 30-day mortality rate of 23%. The median intensive care unit stay was 2 days (range, 2-48 days), and the median hospital stay was 16 days (range, 9-210 days). During the follow-up period, three patients suffered from stent-graft-related complications. The overall mortality rate in our study group was 36%. EVAR is an acceptable, minimally invasive treatment option in patients with acute rAAA, independent of the patient's general condition. Short- and long-term outcomes are definitely comparable to those with open surgical repair procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rupture and Migration of an Endovascular Stent in the Brachiocephalic Trunk Causing a Vertebral Steal Syndrome

Delayed stent fracture has been observed in many different arteries and may represent a risk factor for restenosis. We describe the case of a delayed rupture of an endovascular brachiocephalic trunk stent. The complete fracture allowed a fragment to migrate distally and tilt, resulting in a hemodynamic pattern similar to that of a prevertebral stenosis with complete inversion of the homolateral vertebral blood flow. The induced vertebral steal syndrome as well as the risk of cerebral embolism was corrected by an aortobrachiocephalic bypass and resection of the ruptured stent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗