Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PRODUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Accumulator and Compressor for the CERN SPL Proton Beam

Design study of an accumulator and a compressor for the CERN SPL based proton driver is detailed. Proton beam generated and formed with the complex will be high power and short bunches to drive intense pion beam which finally decays into muon beam.

43 PARTICLE ACCELERATORS↗

Orbit and Optics Distortion in a Nonscaling Muon FFAG

Finite chromaticity in a nonscaling FFAG makes transverse tunes move during acceleration. Particles have to cross many integer and half-integer resonances although all those tunes are imperfection ones. Plausible argument is that the acceleration is so fast that effects of those resonance crossings are marginal. We did a tracking study in a lattice with alignment and gradient errors to see how the orbit and optics distortion is excited. We found that in a time scale of the muon acceleration, namely total tune changes about one unit per turn, the resonance is not a proper way to describe the beam dynamics. Instead, a random walk model, in which we assume that alignment and gradient errors kick a particle randomly in phase space, well explains the tracking results.

43 PARTICLE ACCELERATORS↗

SPIRAL2 at GANIL: Status and Perspectives

To pursue the investigation of a new territory of nuclei with extreme N/Z called 'terra incognita' several projects, all aiming at the increase by several orders of magnitude of the RIB intensities are now under discussions worldwide. In Europe, two major new projects have been approved recently FAIR-GSI using the so-called 'in-flight' method and SPIRAL2-GANIL, based on the ISOL method. Both projects were selected in the European Strategic Roadmap For research Infrastructures (ESFRI). The main goal of SPIRAL2 is clearly to extend our knowledge of the limit of existence and the structure of nuclei deeply in the medium and heavy mass region (A = 60 to 140) which is to day an almost unexplored continent. SPIRAL 2 is based on a high power, CW, superconducting driver LINAC, delivering 5 mA of deuteron beams at 40 MeV (200 KW) directed on a C converter+ Uranium target and producing therefore more 10{sup 13} fissions/s. The expected radioactive beams intensities for exotic species in the mass range from A = 60 to A = 140, of the order of 10{sup 6} to 10{sup 10} pps will surpass by two order of magnitude any existing facilities in the world. These unstable atoms will be available at energies between few KeV/n to 15 MeV/n. The same driver will accelerate high intensity (100 {mu}A to 1 mA), heavier ions up to Ar at 14 MeV/n producing also proton rich exotic nuclei. In applied areas SPIRAL2 is considered as a powerful variable energy neutron source, a must to study the impact of nuclear fission and fusion on materials. The intensities of these unstable species are excellent opportunities for new tracers and diagnostics either for solid state, material or for radiobiological science and medicine. The 'Go' decision has been taken in May 2005. The investments and personnel costs amount to 190 Meuro, for the construction period 2006-2012. Construction of the SPIRAL2 facility is shared by ten French laboratories and a network of international partners. Under the 7FP program of European Union called 'Preparatory phase for the construction of new facilities', the SPIRAL2 project has been granted a budget of about 4Meuro to build up an international consortium around this new venture. The status of the construction of SPIRAL2 accelerator and technical R and D programs for physics instrumentation (detectors, spectrometers) in collaboration with EU and International partners will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photon Science Research at APRC of JAEA

Overviewed is research on photon science and technology at the Advanced Photon Research Center (APRC) of the Japan Atomic Energy Agency (JAEA), where development of ultra-fast, high intensity lasers and their applications are being promoted. The importance of combined applications of laser, accelerators, and synchrotron radiation is emphasized.

43 PARTICLE ACCELERATORS↗

Stable High-Quality Electron Bunch Generation via Counter-Crossing Injection

We demonstrate a highly reproducible acceleration of a high-quality electron bunch injected into the laser wake field accelerator with the help of a counter-crossing laser pulse. In our experiments, the wake field is generated by a sub-relativistic laser pulse; the second laser pulse collides with the first pulse at 135 deg. realizing optical injection of electron bunch into the wake field. Since the second pulse is counter-crossing, it can not damage the laser system. The observed electron bunch has the energy of 14 MeV with a 11% (1.5 MeV) spread, the total charge of 22 pC, a normalized emittance not greater than 0.8{pi} mm mrad, and a reproducibility at least 50%.

43 PARTICLE ACCELERATORS↗

Development of a Source of Quasi-Monochromatic MeV Energy Photons

We report current progress on a project to develop an all-optically-driven x-ray photon source. A laser pulse with 40-50 TW of peak power is focused on a supersonic helium nozzle to drive a relativistic plasma wave. Electron beams with energies of 320 MeV (+/-28 MeV) are accelerated by means of laser wakefield acceleration. Remarkably, the acceleration region is only 3 mm in length. This accelerator is currently being employed to demonstrate the generation of MeV-energy x-ray by means of all-optical Thomson scattering. By this mechanism, a lower power, laser pulse (from the same laser system) is focused onto the above laser-driven electron beam, 1-eV energy photons are Doppler-shifted in energy to >1 MeV.

43 PARTICLE ACCELERATORS↗

Development of a Portable 950 keV X-band Linac for NDT

We are developing a portable 950 keV X-band (9.4 GHz) linac X-ray source for on-site nondestructive testing of erosion of metal pipes at a petrochemical complex. To develop it, we adopted a compact X-band 9.4 GHz magnetron of 250 kW for RF generation device. The whole device, including power supply and cooling devices, were also downsized. The dose rate of X-ray converted in a tungsten target is designed to be 0.2 Gy/min at 1-m distance. We designed an accelerating tube that uses the {pi} mode for the lower energy part and the {pi}/2 mode cavity for the higher energy. We manufactured the accelerating tube and carried out beam acceleration tests, confirming that the electron beam was accelerated up to 950 keV.

43 PARTICLE ACCELERATORS↗

Tuning the operational parameters of the first microtron stage

The Laboratorio do Acelerador Linear is building a racetrack microtron electron accelerator. It has two acceleration stages: the booster and the main microtron. The aim of this work is to optimize the operation parameters of the booster stage by means of simulation tools. The accelerator admittances were determined successfuly and the results are presented. The injection beam has been characterized previously, and the available data were used to match the transverse beam emittances of the injector to the transverse beam admittances of the booster. Preliminary results showed that the simulations have a good agreement with the working parameters.

43 PARTICLE ACCELERATORS↗

The Jefferson lab FEL driver ERLs

Jefferson Lab has - for over a decade - been operating high power IR and UV FELs using CW energy recovering linacs based on DC photocathode electron sources and CEBAF SRF technology. These machines have unique combinations of beam quality, power, and operational flexibility, and thus offer significant opportunity for experiments that use low and medium energy (several tens - few hundreds of MeV) electron beams. We will describe the systems and detail their present and near-term (potential) performance. Recent internal-target analysis and validation testing will be discussed, and schemes for single- and two-pass fixed target operation described. An introduction to subsequent discussions of beam quality and upgrade paths to polarized operation/higher energy will be given.

43 PARTICLE ACCELERATORS↗

Polarimetry at MAMI

Möller and Mott polarimeters have been compared concerning their measurement accuracy in a dedicated 'spin dance' experiment. The results obtained with the different polarimeters at vastly different energy ranges were in agreement with each other within the given systematic uncertainties of a few percent. We discuss investigations of background conditions which may allow to reduce this important contribution to the uncertainties in the Mott polarimeter to a value below 1.0%.

43 PARTICLE ACCELERATORS↗

The phase-lock dynamics of the laser wakefield acceleration with an intensity-decaying laser pulse

An electron beam with the maximum energy extending up to 1.8 GeV, much higher than the dephasing limit, is experimentally obtained in the laser wakefield acceleration with the plasma density of 3.5 × 10{sup 18} cm{sup −3}. With particle in cell simulations and theoretical analysis, we find that the laser intensity evolution plays a major role in the enhancement of the electron energy gain. While the bubble length decreases due to the intensity-decay of the laser pulse, the phase of the electron beam in the wakefield can be locked, which contributes to the overcoming of the dephasing. Moreover, the laser intensity evolution is described for the phase-lock acceleration of electrons in the uniform plasma, confirmed with our own simulation. Since the decaying of the intensity is unavoidable in the long distance propagation due to the pump depletion, the energy gain of the high energy laser wakefield accelerator can be greatly enhanced if the current process is exploited.

43 PARTICLE ACCELERATORS↗

Radial Compression of an Antiproton Cloud for Production of Intense Antiproton Beams

We report here the radial compression of a large number of antiprotons ({approx}5x10{sup 5}) in a strong magnetic field under ultrahigh vacuum conditions by applying a rotating electric field. Compression without any resonant structures was demonstrated for a range of frequencies from the sideband frequency of 200 kHz to more than 1000 kHz. The radial compression achieved is a key technique for synthesizing and manipulating antihydrogen atoms and antiprotonic atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy

Purpose: To develop an efficient and robust tool for output measurement and absolute dose verification of electron beam therapy by using a high spatial-resolution and high frame-rate amorphous silicon flat panel electronic portal imaging device (EPID). Methods: The dosimetric characteristics of the EPID, including saturation, linearity, and ghosting effect, were first investigated on a Varian Clinac 21EX accelerator. The response kernels of the individual pixels of the EPID to all available electron energies (6, 9, 12, 16, and 20 MeV) were calculated by using Monte Carlo (MC) simulations, which formed the basis to deconvolve an EPID raw images to the incident electron fluence map. The two-dimensional (2D) dose distribution at reference depths in water was obtained by using the constructed fluence map with a MC simulated pencil beam kernel with consideration of the geometric and structural information of the EPID. Output factor measurements were carried out with the EPID at a nominal source–surface distance of 100 cm for 2 × 2, 3 × 3, 6 × 6, 10 × 10, and 15 × 15 cm{sup 2} fields for all available electron energies, and the results were compared with that measured in a solid water phantom using film and a Farmer-type ion chamber. The dose distributions at a reference depth specific to each energy and the flatness and symmetry of the 10 × 10 cm{sup 2} electron beam were also measured using EPID, and the results were compared with ion chamber array and water scan measurements. Finally, three patient cases with various field sizes and irregular cutout shapes were also investigated. Results: EPID-measured dose changed linearly with the monitor units and showed little ghosting effect for dose rate up to 600 MU/min. The flatness and symmetry measured with the EPID were found to be consistent with ion chamber array and water scan measurements. The EPID-measured output factors for standard square fields of 2 × 2, 3 × 3, 6 × 6, 10 × 10, 15 × 15 cm{sup 2} agreed with film and ion chamber measurements. The average discrepancy between EPID and ion chamber/film measurements was 0.81% ± 0.60% (SD) and 1.34% ± 0.75%, respectively. For the three clinical cases, the difference in output between the EPID- and ion chamber array measured values was found to be 1.13% ± 0.11%, 0.54% ± 0.10%, and 0.74% ± 0.11%, respectively. Furthermore, the γ-index analysis showed an excellent agreement between the EPID- and ion chamber array measured dose distributions: 100% of the pixels passed the criteria of 3%/3 mm. When the γ-index was set to be 2%/2 mm, the pass rate was found to be 99.0% ± 0.07%, 98.2% ± 0.14%, and 100% for the three cases. Conclusions: The EPID dosimetry system developed in this work provides an accurate and reliable tool for routine output measurement and dosimetric verification of electron beam therapy. Coupled with its portability and ease of use, the proposed system promises to replace the current film-based approach for fast and reliable assessment of small and irregular electron field dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-E-T-251: Developing a Daily Proton Beam Monitoring System

Purpose: To develop a daily monitoring system for proton beam output check and beam uniformity check. Methods: Designed for continuously irradiated photon and electron beams with a field size of 20 cm x 20 cm, the daily output checker (Sun Nuclear, Inc.) is not suitable for monitoring proton beams with inter-pulse beam-off and a field size smaller than 14–16 cm in diameter. To allow such proton beam monitoring, the following tests were performed. 1. Absolute dose and array calibrations which accept continuous irradiation only, were performed using photon beams. 2. Five ion chambers within the central area of 8 cm x 8 cm were utilized to check constancy of output at the center of beam modulation and at distal edge and to check beam symmetry and flatness. 3. To simplify our evaluation, the array calibration was manually modified, such that all five chambers report equal values in spite of their differences in build-up thicknesses. 4. The chamber at the lower-right corner is placed under a buildup thickness that can offer dose measurement at the distal edge. This buildup thickness was determined by proton beam range measurements, which established buildup thickness for beam output measurement at the central chamber and range measurement at the corner chamber. 5. The beam-off delay which allows receipt of pulsed irradiation was activated and optimal delay times were determined for each proton beam at 149.6, 185.6, and 249.5 MeV. Results: The above system was tested by miss-steering proton beams and altering phantom thickness by 1 mm at a time. The system reliably monitored the beam with: 3% tolerance for beam flatness, symmetry and output. The range difference of 0.5 mm could be detected at all energies by setting a tolerance of 20%. Conclusion: A quick daily proton beam monitoring system was feasible.

07 ISOTOPE AND RADIATION SOURCES↗

Design of the Next Generation Target at the Lujan Neutron Scattering Center, LANSCE

Los Alamos National Laboratory (LANL) supports scientific research in many diverse fields such as biology, chemistry, and nuclear science. The Laboratory was established in 1943 during the Second World War to develop nuclear weapons. Today, LANL is one of the largest laboratories dedicated to nuclear defense and operates an 800 MeV proton linear accelerator for basic and applied research including: production of high- and low-energy neutrons beams, isotope production for medical applications and proton radiography. This accelerator is located at the Los Alamos Neutron Science Center (LANSCE). The work performed involved the redesign of the target for the low-energy neutron source at the Lujan Neutron Scattering Center, which is one of the facilities built around the accelerator. The redesign of the target involves modeling various arrangements of the moderator-reflector-shield for the next generation neutron production target. This is done using Monte Carlo N-Particle eXtended (MCNPX), and ROOT analysis framework, a C++ based-software, to analyze the results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion resonances and ELF wave production by an electron beam injected into the ionosphere - ECHO 6

Two effects observed with electron antennas ejected from a sounding rocket launched into the ionosphere in March 1983 carrying electron beam guns are discussed. The sensor packages were ejected and travelled parallel to the vehicle trajectory. Electric potentials were measured between the single probes and a plasma diagnostic package while the gun injected electrons into the ionosphere in perpendicular and parallel 1 kHz directions. Signal pulses over the dc-1250 kHz range were detected. A kHz gun frequency caused a signal that decreased by two orders of magnitude between 45-90 m from the beam field line. However, the signal was detectable at 1 mV/m at 120 m, supporting earlier data that indicated that pulsed electron beams can cause ELF waves in space. Beam injection parallel to the magnetic field produced an 840 Hz resonance that could be quenched by activation of a transverse beam.

Winckler, J. R.↗

ELF wave production by an electron beam emitting rocket system and its suppression on auroral field lines - Evidence for Alfven and drift waves

Orthogonal probes on a free-flying plasma diagnostics payload are used to study ELF electric disturbances in the auroral ionosphere that are due to the injection of powerful electron beams. Frequency spectrograms are presented for various pitch angles, pulsing characteristics, and other properties of the injected beams; the large scale DC ionospheric convection electric field is measured, together with auroral particle precipitation, visual auroral forms, and ionospheric parameters. In view of the experimental results obtained, it is postulated that the observed ELF waves are in the Alfven and drift modes, and are generated by the positive vehicle potential during beam injection.

Winckler, J. R.↗