Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ambient Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

High-Pressure Synthesis: A New Frontier in the Search for Next-Generation Intermetallic Compounds

The application of high pressure adds an additional dimension to chemical phase space, opening up an unexplored expanse bearing tremendous potential for discovery. Our continuing mission is to explore this new frontier, to seek out new intermetallic compounds and new solid-state bonding. Simple binary elemental systems, specifically those composed of pairs of elements that do not form compounds under ambient pressures, can yield novel crystalline phases under compression. Thus, high-pressure synthesis can provide access to solid-state compounds that cannot be formed with traditional thermodynamic methods. An emerging approach for the rapid exploration of composition–pressure–temperature phase space is the use of hand-held high-pressure devices known as diamond anvil cells (DACs). These devices were originally developed by geologists as a way to study minerals under conditions relevant to the earth’s interior, but they possess a host of capabilities that make them ideal for high-pressure solid-state synthesis. Of particular importance, they offer the capability for in situ spectroscopic and diffraction measurements, thereby enabling continuous reaction monitoring—a powerful capability for solid-state synthesis. Here, we offer an overview of this approach in the context of research we have performed in the pursuit of new intermetallic compounds. We start with a discussion of pressure as a fundamental experimental variable that enables the formation of intermetallic compounds that cannot be isolated under ambient conditions. We then introduce the DAC apparatus and explain how it can be repurposed for use as a synthetic vessel with which to explore this phase space, going to extremes of pressure where no chemist has gone before. The remainder of the Account is devoted to discussions of recent experiments we have performed with this approach that have led to the discovery of novel intermetallic compounds in the Fe–Bi, Cu–Bi, and Ni–Bi systems, with a focus on the cutting-edge methods that made these experiments possible. We review the use of in situ laser heating at high pressure, which led to the discovery of FeBi2, the first binary intermetallic compound in the Fe–Bi system. Our work in the Cu–Bi system is described in the context of in situ experiments carried out in the DAC to map its high-pressure phase space, which revealed two intermetallic phases (Cu11Bi7 and CuBi). Finally, we review the discovery of β-NiBi, a novel high-pressure phase in the Ni–Bi system. We hope that this Account will inspire the next generation of solid-state chemists to boldly explore high-pressure phase space.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Frequency Domain Methodology for Quantitative Evaluation of Diffuse Wavefield With Applications to Seismic Imaging

Abstract Ambient Noise Imaging (ANI) of subsurface structures relies on seismic interferometry of diffuse seismic wavefields. However, the lack of effective methods to quantify and identify highly diffuse waves hampers applications of ANI, particularly in evaluating seismic attenuation and monitoring structural changes with high temporal resolution. Conventional ANI approaches require data normalization, which effectively suppresses the non‐diffuse component with large amplitude but also results in significant loss of amplitude and phase information in the continuous seismic records. In this study, we propose a frequency domain method to quantitatively evaluate the degree of diffuseness of seismic wavefields by analyzing their statistical characteristics of modal amplitudes for stationarity and randomness. Tests on synthetic waveform and field nodal records show that the proposed method can effectively distinguish between diffuse and non‐diffuse waveforms for either single‐ or three‐component data. As an application, we identify a 60‐s‐long diffuse coda of a local M 2.2 earthquake recorded by a dense nodal array on the San Jacinto Fault Zone, and successfully extract high‐quality dispersion curve andQ‐value without performing data normalization. These results are consistent with those obtained by conventional methods that assess the correlation between coherency and the Green's function, and by modeling ballistic waves generated by road traffic. Our proposed method can advance the imaging of subsurface velocity and attenuation structures as well as monitoring temporal changes for scientific studies and engineering applications.

Geochemistry & Geophysics↗

CRYOGENIC CONTROLS FOR FERMILAB'S SRF CAVITIES AND TEST FACILITY

A new superconducting radio frequency (SRF) cavities test facility is now operational at Fermilab's Meson Detector Building (MDB). The Cryogenic Test Facility (CTF), located in a separate building 500 m away, supplies the facility with cryogens. The design incorporates ambient temperature pumping for superfluid helium production, as well as three 0.6 kW at 4.5 K refrigerators, five screw compressors, a helium purifier, helium and nitrogen inventory, cryogenic distribution system, and a variety of test cryostats.To control and monitor the vastly distributed cryogenic system, a flexible scheme has been developed. Both commercial and experimental physics tools are used. APACS+, a process automation control system from Siemens-Moore, is at the heart of the design. APACS+ allows engineers to configure an ever evolving test facility while maintaining control over the plant and distribution system. APACS+ nodes at CTF and MDB are coupled by a fiber optic network. DirectLogic205 PLCs by KOYO are used as the field level interface to most I/O.The top layer of this system uses EPICS (Experimental Physics and Industrial Control System) as a SCADA/HMI. Utilities for graphical display, control loop setting, real time/historical plotting and alarming have been implemented by using the world-wide library of applications for EPICS.OPC client/server technology is used to bridge across each different platform.This paper presents this design and its successful implementation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Helium-cold induced hypothermia in the white rat.

Hypothermia was induced in white rats by exposing them to low ambient temperatures (about 0 C) and a gaseous atmosphere of 80% helium and 20% oxygen (helox). Biological survival, in which revival from hypothermia to normothermia is achieved, and clinical survival, in which one or more functional attributes are monitored in the hypothermic animal until it dies, are examined. The helium-cold method appears to produce a hypothermic state in the rat quite similar to that resulting from such techniques as ice water immersion or hypercapnia + hypoxia. There is a direct relationship between body weight and percent survival. Despite the fact that they require a longer period to become hypothermic, the heavier animals are better able to survive.

Musacchia, X. J.↗

Simultaneous measurement of three atmospheric pollutants

Method enables simultaneous concentration monitoring of atmospheric SO2, NO, and NO2. Fluorescing pollutant gases in sample are excited by visible output of dye laser and its second-harmonic ultraviolet frequencies. Three photomultipliers, each with suitable optical filters, view fluorescence. Method tests ambient air, stack emissions, and highway automotive exhausts.

Sinha, M. P.↗

Multisensor robotic system for autonomous space maintenance and repair

The feasibility of realistic autonomous space manipulation tasks using multisensory information is demonstrated. The system is capable of acquiring, integrating, and interpreting multisensory data to locate, mate, and demate a Fluid Interchange System (FIS) and a Module Interchange System (MIS). In both cases, autonomous location of a guiding light target, mating, and demating of the system are performed. Implemented visio-driven techniques are used to determine the arbitrary two-dimensional position and orientation of the mating elements as well as the arbitrary three-dimensional position and orientation of the light targets. A force/torque sensor continuously monitors the six components of force and torque exerted on the end-effector. Both FIS and MIS experiments were successfully accomplished on mock-ups built for this purpose. The method is immune to variations in the ambient light, in particular because of the 90-minute day-night shift in space.

Abidi, M. A.↗

Capacity decline of ambient temperature secondary Li-TiS2 cells

The main objective of the study described was to identify the causes responsible for the capacity losses observed during cycling of secondary Li-TiS2 cells. Experimental Li-TiS2 cells were fabricated and tested for their cycle life performance. The open circuit voltage of the cells was monitored during the rest period between the charging and discharging. The polarization at the Li and TiS2 electrodes was also monitored during cycling. Cycled cells were disassembled and the cathodes were analyzed by various analytical techniques. The results of the study indicate that the observed capacity loss is almost entirely due to the increased polarization of the TiS2 electrode with cycling. The electrolyte was found to degrade during cycling and the degradation products were found to deposit at the TiS2 electrode, which probably lead to the higher polarization.

Subbarao, S.↗

Variations in dose distribution and optical properties of Gafchromic{sup TM} EBT2 film according to scanning mode

Purpose: The authors aim was to investigate the effects of using transmission and reflection scanning modes, the film orientation during scanning, and ambient room light on a dosimetry system based on the Gafchromic{sup TM} EBT2 film model. Methods: For calibration, the films were cut to 3 x 3 cm{sup 2} and irradiated from 20 to 700 cGy at the depth of maximum dose using 6 and 10 MV photon beams in a 10 x 10 cm{sup 2} field size. Absolute dose calibration of the linear accelerator was done according to the TRS398 protocol. An FG65-G ionization chamber was used to monitor the dose while irradiating the films in solid water. The film pieces were scanned with an EPSON Expression 1680 Pro flatbed scanner in transmission and reflection modes. Authors investigated the effect of orientation on films and examined the optical properties of EBT2 film using an ellipsometer and an ultraviolet (UV)/visible spectrometer to explain the dosimetric dependence of the film on orientation during the scanning process. To investigate the effect of ambient room light, films were preirradiated in 6 and 10 MV photon beams with intensity-modulated radiotherapy (IMRT) quality assurance (QA) plans, and then exposed to room light, either directly for 2 days in a workroom or for 2 months in a film box. Gamma index pass criteria of (3%, 3 mm) were used. Results: The dose response curves based on net optical density (NOD) indicated that the reflection scanning mode can provide a better dose sensitivity than the transmission scanning mode, whereas the standard deviation of the dose is greater in reflection mode than in transmission mode. When the film was rotated 90 deg. from the portrait orientation, the average dose of the EBT2 film decreased by 11.5-19.6% in transmission mode and by 1.5-2.3% in reflection mode. Using an ellipsometer, variation of the refractive index of EBT2 film--the birefringence property--was found to be the largest between 45 deg. (1.72 and 1.71) and 135 deg. (1.8 and 1.77) for 300 and 800 cGy. Absorption spectra of EBT2 films measured with spectrometer were the function of film orientation. The readings in reflection scanning mode were more stable against room light than those in transmission scanning mode, although dose readings increased in both modes after the films were exposed to room light. Conclusions: The transmission scanning mode exhibited a strong dependence on film orientation during scanning and a change in optical density resulting from room light exposure, so a constant scanning orientation and minimal exposure to light can reduce uncertainty in the measured dose (23 {+-} 3%). The angular dependence was analyzed using Jones matrices and optical properties of EBT2 film were obtained using an ellipsometer and an UV/visible spectrometer. The reflection scanning mode has relatively good stability with respect to room light and film orientation on a scanner, although the large standard deviation of dose is a disadvantage in measurements of absolute dose. Reflection scanning mode can offer a potential advantage for film dosimetry in radiotherapy, although transmission scanning mode is still recommended for dosimetry as it provides better uncertainty results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hydrogen Wide Area Monitoring of LH2 Releases at HSE for the PRESHLY Project

The characterization of liquid hydrogen (LH2) releases has been identified as an international research priority to expand the safe use of hydrogen as an energy carrier. Empirical field measurements such as those afforded by Hydrogen Wide Area Monitoring (HyWAM) can elucidate the behavior of LH2 releases, which can then be used to support and validate dispersion models. HyWAM can be defined as the quantitative three-dimensional spatial and temporal profiling of planned or unintentional hydrogen releases. The NREL Sensor Laboratory developed a HyWAM based upon a distributed array of hydrogen Sensors. The NREL Sensor Laboratory and Health and Safety Executive (HSE) formally committed to collaborate on profiling GH2 and LH2 releases, which allowed for the integration of the NREL HyWAM into the HSE LH2 release behavior investigation supported by the FCH JU Prenormative Research for the Safe Use of Liquid Hydrogen (PRESLHY) program. A HyWAM system consisting of 32 hydrogen measurement points and co-located temperature sensors were distributed downstream of the LH2 release apparatus developed by HSE. In addition, there were proximal wind and weather monitors. In a separate presentation at this conference "HSE SD Experimental Summary for the Characterisation, Dispersion and Electrostatic Hazards of LH2 for the PRESLHY Project" HSE researchers summarize the experimental apparatus and experimental protocols utilized in the HSE LH2 releases that were performed under the auspices of PRESLHY. To supplement the HSE presentation, this presentation will focus on the spatial and temporal behavior LH2 releases as measured by the NREL HyWAM. Correlations to ambient conditions, such as wind speed and direction, plume temperature and hydrogen concentrations will be discussed in addition to the design and performance of the NREL HyWAM, and its potential for improving hydrogen facility safety.

HYDROGEN↗

Multi-static Serial LiDAR for Surveillance and Identification of Marine Life at MHK Installations

Final Report for project DE-EE0006787: Multi-static Serial LiDAR for Surveillance and Identification of Marine Life at MHK Installations. This project developed and tested an optical monitoring system prototype that will be suitable for marine and hydrokinetic (MHK) full project lifecycle observation (baseline, commissioning, and decommissioning), with automated real-time classification of marine animals. This system can be deployed to collect pre-installation baseline species observations at a proposed deployment site with minimal post-processing overhead. To satisfy deployed MHK project species of concern (e.g. Endangered Species Act-listed) monitoring requirements, the system provides automated tracking and notification of the presence of managed animals within established perimeters of MHK equipment and provides high resolution imagery of their behavior through a wide range of conditions. During a project’s decommissioning stage, the system can remain installed to provide resource managers with post-installation data. Our technology, known as an Unobtrusive Multi-static Serial LiDAR Imager (UMSLI), is a technology transfer of underwater distributed LiDAR imaging technology that preserves the advantages of traditional optical and acoustic solutions while overcoming associated disadvantages for MHK environmental monitoring applications. This new approach is a purposefully-designed, reconfigurable adaptation of an existing technology that can be easily mounted on or around different classes of MHK equipment. The system uses low average power red (638nm) laser illumination to be invisible and eye-safe to marine animals and is compact and cost effective. The equipment is designed for long term, maintenance-free operations, to inherently generate a sparse primary dataset that only includes detected anomalies (animal presence information), and to allow robust real-time automated animal classification/identification with a low data bandwidth requirement. Advantages of the technology over others currently being used or being considered for MHK monitoring include: Unlike a conventional camera, the depth of field is near-infinite and limited by attenuation (approximately 5-8 m) rather than focal properties of a lens; Operation in an adaptive mode which can project a sparse grid of pulses with higher peak power for longer range detection (>10 meters) and track animals within a zone of interest with high resolution imagery for identification of marine life at closer range (<5m); System detection limit and Signal-to-Noise-Ratio is superior to a camera, due to rejection of both backscattering component and ambient solar background; Multiple wide-angle pulsed laser illuminators and bucket detectors can be flexibly configured to cover a 4pi steradian (i.e. omnidirectional) scene volume, while also retrieving 3D features of animal targets from timing information; Process and classification framework centered around a novel active learning and incremental classification classifier that enables accurate identification of a variety of marine animals automatically; A two-tiered monitoring architecture and invisible watermarking-based data archiving and retrieving approach ensures significant data reduction while preserving high fidelity monitoring. A methodology to train and optimize the classifier for target species of concern to optimize site monitoring effectiveness. This technological innovation addresses a high priority regulatory requirement to observe marine life interaction near MHK projects. Our solution improves resource manager confidence that any interactions between marine animals and equipment are observed in a cost-effective and automated manner. Without EERE funding, this novel application of multi-static LiDAR would not have been available to the MHK community for environmental monitoring.

16 TIDAL AND WAVE POWER↗

Bayesian Geostatistical Modelling of PM10 and PM2.5 Surface Level Concentrations in Europe Using High-Resolution Satellite-Derived Products

Air quality monitoring across Europe is mainly based on in situ ground stations which are too sparse to accurately assess the exposure effects of air pollution for the entire continent. The demand for precise predictive modelsthat estimate gridded geophysical parameters of ambient air at high spatial resolution has rapidly grown. Here, we investigate the potential of satellite derived products to improve particulate matter (PM) estimates. Bayesiangeostatistical models addressing confounding between the spatial distribution of pollutants and remotely sensed predictors were developed to estimate yearly averages of both, fine (PM2.5) and coarse (PM10) surface PM concentrations at 1 sq.km spatial resolution over 46 European countries and were compared to geostatistical, geographically weighted and land-use regression formulations. Rigorous model selection identified the Earth observation data which contribute most to pollutants' estimation. Geostatistical models outperformed the predictive ability of the frequently employed land-use regression. The resulting estimates of PM10 and PM2.5, which represent the main air quality indicators for the urban Sustainable Development Goal, indicate that in 2016, 66.2% of the European population was breathing air above the WHO Air Quality Guidelines thresholds. Our estimates are readily available to policy makers and scientists assessing the effects of long-term exposure to pollution on human and ecosystem health.

Beloconi, Anton↗

Modeling and Analysis of Coupled Flow Through Packed Beds as a Diagnostic Tool for Packed Bed Reactor Health - 17172

The US Department of Energy, Office of River Protection, is building the Waste Treatment and Immobilization Plant (WTP) in Richland, Washington, to immobilize the hundreds of millions of liters of radioactive waste stored at the Hanford Site in Washington state. The offgas generated during vitrification of these wastes requires treatment to remove and/or destroy chemical and radioactive hazardous components before release to the atmosphere. In particular, volatile and semi-volatile hydrocarbon components are to be catalytically oxidized to carbon dioxide and water, whereas nitrogen oxides (NOx) are to be catalytically reduced to nitrogen and water. These tasks are accomplished in a series of packed bed reactors. Achieving the requisite Destruction/Removal Efficiency (DRE) for each of the tracked components is highly dependent on the flow characteristics of the offgas through the packed beds. The flow kinetics may be monitored and characterized during the initial warm-up of the system. The gases, initially at 76 deg. C (169 deg. F), (a) flow through one side of a countercurrent heat exchanger to recover heat from the exiting gases (which have already passed through the catalytic beds), (b) are then further heated electrically to approximately 400 deg. C (750 deg. F; the preferred operating temperature of the Thermo Catalytic Oxidizer (TCO)), (c) pass through the TCO where the reduced components of the offgas are oxidized over a supported Pt catalyst bed, (d) are partially cooled to approximately 315 deg. C (600 deg. F) by addition of approximately 25% (by weight) diluted ammonia/air mixture, (e) pass through the Selective Catalytic Reducer (SCR) where the NOx components are converted to N{sub 2} and H{sub 2}O over a supported V2O{sub 5}/TiO{sub 2} catalyst bed, and (f) exit through the hot side of the countercurrent heat exchanger. The electrical heater is not powerful enough to raise the temperature of the offgas to the desired 400 deg. C without the contribution of the heat recovered in the heat exchanger. Moreover, the thermal mass of the beds and housings of the TCO and SCR require a significant input of thermal energy to reach the desired operating temperatures; the better part of a day is required to bring the unit from ambient temperatures to operating temperatures. Therefore, the temperature of the stream during the initial warm-up of the system at each point in the system is dependent upon the thermal mass, flow dispersion, and permeability of the components, quantified as characteristic/representative volumes and residence times. By monitoring the temperature of the offgas as it enters and exits each portion of the system during this warm-up period one may model the system as a series of small Continuously Stirred Tank Reactors (CSTR)s (referred to as 'CSTRlets') to explain the flow kinetics through the catalyst beds. These component CSTRlets are adjustable in size and number, that one may model the flow profile of the gases through the catalyst beds. For example, a single large CSTR will present an effluent temperature profile with a simple exponential decay shape. Concatenating more CSTRlets generate more complex sigmoidal responses. Concatenating one CSTRlet significantly larger than the others in the train also alters the shape of the effluent temperature profile, in a fashion not replicable by a train of equal-sized CSTRlets. The ultimate goal is to accurately emulate the entire system as a representative CSTRlet train. Once accomplished, this characterization may be used in subsequent warm-ups (following shutdown for catalyst maintenance, for example) or by an intentional step change in inlet offgas temperature to detect/diagnose anomalies in flow through the beds (e.g., channeling or partial blockage.) This work presents development of this model through analytical, calculational, and empirical means. - The analytic model is accomplished by Laplace transform analysis of each component to recover component process transfer functions. - The calculational portion is performed via brute force finite element calculation. - Fitting empirical data from the warm-up of the TCO skid allows one to select the hypothetical CSTRlet trains which best fit the TCO and SCR beds for the analytical and finite element calculations. The first portion of this paper presents the development of the analytical (Laplace space) model of the coupled system. Estimated values for the initial temperature, mass, specific heat, electrical heat, and relative quantities of the offgas, catalyst beds, stainless steel housings, and ammonia dilution stream are used to generate expected temperature profiles at several selected junctures of the system. The number and size of the component hypothetical CSTRlets are calculated from the analytical model and are used to predict temperature profiles at the exit of the system and at intermediate junctions between system components (where thermocouples are present in the actual unit.) The finite element calculations employ a series of CSTRlet volumes to produce a similar suite of temperature profiles, for comparison with the analytical model results. Finally, empirical data from the Factory Acceptance Test system warm-up are used to select and compare the results from each modeling strategy to select the CSTRlet train(s) which best model the behavior of the actual system. This work presents a novel method of system component characterization, of value to the WTP plant and similar vitrification facilities as well as chemical process industries unrelated to waste management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Environmental Air Monitoring at LANL: 2023 External Program Assessment [Slides]

Radioactive Air Emissions Management evaluates radiological impacts of LANL operations on members of the public, identifies and quantifies releases, and assesses impacts. It is not directly affiliated with cleanup operations or programmatic work and has independent oversight. The focus areas in Environmental Compliance Programs are stack emissions measurements, ambient air measurements, minor source operations evaluations, data management and quality assurance, collaboration with Meteorology program, and collaboration with Dose Assessment program (EPC-ES).

54 ENVIRONMENTAL SCIENCES↗

Characterization of Fine Particulate Matter (PM) and Secondary PM Precursor Gases in Mexico City

This project was one of three collaborating grants designed to understand the atmospheric chemistry and aerosol particle microphysics impacting air quality in the Mexico City Metropolitan Area (MCMA) and its urban plume. The overall effort, titled MCMA- 2006, focused on: 1) the primary emissions of fine particles and precursor gases leading to photochemical production of atmospheric oxidants and secondary aerosol particles and 2) the measurement and analysis of secondary oxidants and secondary fine particular matter (PM) production, with particular emphasis on secondary organic aerosol (SOA). MCAM-2006 pursued it goals through three main activities: 1) performance and publication of detailed analyses of extensive MCMA trace gas and fine PM measurements made by the collaborating groups and others during earlier MCMA field campaigns in 2002 and 2003; 2) deployment and utilization of extensive real-time trace gas and fine PM instrumentation at urban and downwind MCMA sites in support of the MAX-Mex/MILAGRO field measurements in March, 2006; and, 3) analyses of the 2006 MCMA data sets leading to further publications that are based on new data as well as insights from analysis and publication of the 2002/2003 field data. Thirteen archival publications were coauthored with other MCMA-2003 participants. Documented findings included a significantly improved speciated emissions inventory from on-road vehicles, a greatly enhanced understanding of the sources and atmospheric loadings of volatile organic compounds, a unique analysis of the high fraction of ambient formaldehyde from primary emission sources, a much more extensive knowledge of the composition, size distributions and atmospheric mass loadings of both primary and secondary fine PM, including the fact that the rate of MCMA SOA production greatly exceeded that predicted by current atmospheric models, and evaluations of significant errors that can arise from standard air quality monitors for ozone and nitrogen dioxide. Deployment of the Aerodyne mobile laboratory, equipped with instruments from five collaborating laboratories, at the T0 urban supersite, four downwind sites and the Tula industrial area yielded unique trace gas and fine PM data sets during the March 2006 MAXMex/MILAGRO campaign. In addition, on-road measurements as the mobile laboratory moved between sites provided extensive data on 2006 MCMA fleet averaged vehicle emissions. Analyses of 2006 data sets have yielded the identification of a close correlation between the rate of production of SOA and “Odd Oxygen” (O3 + NO2) and primary organic PM with CO in the MCMA urban plume, a more sophisticated understanding of the interplay between nitrogen oxide speciation and ozone production, the identification of significant vehicular emission sources of HCN and CH3CN (usually associated with biomass burning), characterization of the aging of primary carbonaceous PM, and updated 2006 MCMA fleet on-road trace gas and fine PM emissions. Results from analyses of 2002/2003 and 2006 emissions and ambient measurements have conveyed to Mexican air quality managers who are using these data to devise and assess air quality management strategies. All data sets and published analyses are available to DOE/ASP researchers evaluating the impact of urban emissions on regional climate.

54 ENVIRONMENTAL SCIENCES↗

Impact of Oxygen Non-Stoichiometry on Near-Ambient Temperature Ionic Mobility in Polaronic Mixed-Ionic-Electronic Conducting Thin Films

Enhanced ionic mobility in mixed ionic and electronic conducting solids contributes to improved performance of memristive memory, energy storage and conversion, and catalytic devices. Ionic mobility can be significantly depressed at reduced temperatures, for example, due to defect association and therefore needs to be monitored. Measurements of ionic transport in mixed conductors, however, proves to be difficult due to dominant electronic conductivity. This study examines the impact of different levels of quenched-in oxygen deficiency on the oxygen vacancy mobility near room temperature as measured by a novel dynamic current-voltage analysis. A Pr 0.1 Ce 0.9 O 2-δ film was grown by pulsed laser deposition and subsequently annealed, from 400-600° C, in various oxygen partial pressures to modify its oxygen vacancy concentration while minimizing microstructural growth and cation segregation. To monitor changes in film non-stoichiometry, we leverage the existence of an optical absorption center, related to the oxidation state of Pr ions in Pr0.1Ce0.9O2-δ. The oxygen vacancy migration enthalpy was found to exhibit a small increase from 0.73± 0.04 to 0.79 ± 0.02 eV with increasing oxygen deficiency, while the pre-factor was found to increase by a factor of 135. Here, a nearly 13-fold increase in ionic mobility at 60 °C for increases in oxygen non-stoichiometry from 0.032 ± 0.001 to 0.042± 0.001 was thereby detected. Raman spectroscopy was employed to rule out changes in strain as the primary cause for the significant change in mobility. Several factors potentially contributing to the large pre-factor changes are examined and discussed. Insights into how ionic defect concentration can markedly impact ionic mobility should help in elucidating the origins of variations seen in nanoionic devices.

36 MATERIALS SCIENCE↗

Volatile Organic Compounds in Bankhead National Forest (AMF3). August to September, 2025

The formation of atmospheric aerosols through the transformation of volatile organic compounds (VOCs) is a fundamental process in aerosol-climate interactions, as these particles serve as cloud condensation nuclei and ultimately influence Earth’s radiative balance. However, there remains a critical need to quantify the effects of multiple coexisting VOC precursors on aerosol formation beyond the limitations of laboratory-scale studies. This research aims to advance the mechanistic understanding of secondary organic aerosol formation in the southeastern United States by investigating interactions among coexisting VOC precursors observed at the third ARM Mobile Facility located in the Bankhead National Forest. The dataset was generated from the deployment of Oak Ridge National Laboratory’s PTR-TOF 6000 X2 Proton Transfer Reaction Time-of-Flight Mass Spectrometer (PTR-ToF-MS) for the real-time, continuous monitoring of VOCs from August 21 to September 15, 2025. To minimize sampling artifacts and compound losses, the PTR-ToF-MS inlet was connected to the cabin flow line by replacing the existing Tygon tubing with 1/2-inch outer diameter perfluoroalkoxy (PFA) tubing. The instrument operated on an hourly measurement cycle consisting of 8 minutes of zero-air measurements followed by 52 minutes of ambient air sampling, with a temporal resolution of 10 seconds. The dataset includes concentrations, reported in ppb, of methanol, acetone, acetonitrile, isoprene, methyl vinyl ketone and methacrolein (MVK + MACR), monoterpenes, benzene, toluene, and catechol.

Atmospheric concentration of volatile organic comp↗

Wavefront control of the Large Optics Test and Integration Site (LOTIS) 6.5m Collimator

The LOTIS Collimator provides scene projection within a 6.5m diameter collimated beam used for optical testing research in air and vacuum. Diffraction-limited performance (0.4 to 5{mu}m wavelength) requires active wavefront control of the alignment and primary mirror shape. A hexapod corrects secondary mirror alignment using measurements from collimated sources directed into the system with nine scanning pentaprisms. The primary mirror shape is controlled with 104 adjustable force actuators based on figure measurements from a center-of-curvature test. A variation of the Hartmann test measures slopes by monitoring the reflections from 36 small mirrors bonded to the optical surface of the primary mirror. The Hartmann source and detector are located at the f/15 Cassegrain focus. Initial operation has demonstrated a closed-loop 110nmrms wavefront error in ambient air over the 6.5mcollimated beam.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗