Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AUTOCLAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Improving Interlaminar Shear Strength

To achieve NASA's mission of space exploration, innovative manufacturing processes are being applied to the fabrication of complex propulsion elements.1 Use of fiber-reinforced, polymeric composite tanks are known to reduce weight while increasing performance of propulsion vehicles. Maximizing the performance of these materials is needed to reduce the hardware weight to result in increased performance in support of NASA's missions. NASA has partnered with the Mississippi State University (MSU) to utilize a unique scalable approach of locally improving the critical properties needed for composite structures. MSU is responsible for the primary development of the concept with material and engineering support provided by NASA. The all-composite tank shown in figure 1 is fabricated using a prepreg system of IM7 carbon fiber/CYCOM 5320-1 epoxy resin. This is a resin system developed for out-of-autoclave applications. This new technology is needed to support the fabrication of large, all composite structures and is currently being evaluated on a joint project with Boeing for the Space Launch System (SLS) program. In initial efforts to form an all composite pressure vessel using this prepreg system, a 60% decrease in properties was observed in scarf joint regions. Inspection of these areas identified interlaminar failure in the adjacent laminated structure as the main failure mechanism. This project seeks to improve the interlaminar shear strength (ILSS) within the prepreg layup by locally modifying the interply region shown in figure 2.2

Jackson, Justin↗

Establishing and Monitoring an Aseptic Workspace for Building the MOMA Mass Spectrometer

Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the ESA ExoMars 2018 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). As MOMA-MS is a life-detection instrument and it thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 sporem2 is allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three cleanrooms with varying levels of bioburden control. The Aseptic Assembly Cleanroom has the highest level of control, applying three different bioburden reducing methods: 70 IPA, 7.5 Hydrogen Peroxide, and Ultra-Violet C light. The three methods are used in rotation and each kills microbes by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Cleanrooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of cleanrooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and DHMR verification. The cleanrooms are monitored both for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic the other cleanroom.

Contamination Control Engineering↗

Establishing and Monitoring an Aseptic Workspace for Building the MOMA Mass Spectrometer

Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the European Space Agency (ESA) ExoMars 2020 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). MOMA-MS is a life-detection instrument and thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 spore/m2 are allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three clean rooms with varying levels of bioburden control. The Aseptic Assembly Clean room has the highest level of control, applying three different bioburden reducing methods: 70% Isopropyl Alcohol (IPA), 7.5% Hydrogen Peroxide, and Ultra-Violet C (UVC) light. The three methods are used in rotation and each kills microorganisms by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Clean rooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of clean rooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and Dry Heat microbial Reduction (DHMR) verification. The clean rooms are monitored for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic and other clean room.

Contamination Control Engineering↗

Composite Cure Process Modeling and Simulations using COMPRO(Registered Trademark) and Validation of Residual Strains using Fiber Optics Sensors

Composite cure process induced residual strains and warping deformations in composite components present significant challenges in the manufacturing of advanced composite structure. As a part of the Manufacturing Process and Simulation initiative of the NASA Advanced Composite Project (ACP), research is being conducted on the composite cure process by developing an understanding of the fundamental mechanisms by which the process induced factors influence the residual responses. In this regard, analytical studies have been conducted on the cure process modeling of composite structural parts with varied physical, thermal, and resin flow process characteristics. The cure process simulation results were analyzed to interpret the cure response predictions based on the underlying physics incorporated into the modeling tool. In the cure-kinetic analysis, the model predictions on the degree of cure, resin viscosity and modulus were interpreted with reference to the temperature distribution in the composite panel part and tool setup during autoclave or hot-press curing cycles. In the fiber-bed compaction simulation, the pore pressure and resin flow velocity in the porous media models, and the compaction strain responses under applied pressure were studied to interpret the fiber volume fraction distribution predictions. In the structural simulation, the effect of temperature on the resin and ply modulus, and thermal coefficient changes during curing on predicted mechanical strains and chemical cure shrinkage strains were studied to understand the residual strains and stress response predictions. In addition to computational analysis, experimental studies were conducted to measure strains during the curing of laminated panels by means of optical fiber Bragg grating sensors (FBGs) embedded in the resin impregnated panels. The residual strain measurements from laboratory tests were then compared with the analytical model predictions. The paper describes the cure process procedures and residual strain predications, and discusses pertinent experimental results from the validation studies.

Sreekantamurthy, Thammaiah↗

Development of a Fully Automated Guided Wave System for In-Process Cure Monitoring of CFRP Composite Laminates

A guided wave-based in-process cure monitoring technique for carbon fiber reinforced polymer (CFRP) composites was investigated at NASA Langley Research Center. A key cure transition point (vitrification) was identified and the degree of cure was monitored using metrics such as amplitude and time of arrival (TOA) of guided waves. Using an automated system preliminarily developed in this work, high-temperature piezoelectric transducers were utilized to interrogate a twenty-four ply unidirectional composite panel fabricated from Hexcel (Registered Trademark) IM7/8552 prepreg during cure. It was shown that the amplitude of the guided wave increased sharply around vitrification and the TOA curve possessed an inverse relationship with degree of cure. The work is a first step in demonstrating the feasibility of transitioning the technique to perform in-process cure monitoring in an autoclave, defect detection during cure, and ultimately a closed-loop process control to maximize composite part quality and consistency.

Hudson, Tyler B.↗

Lightweight, Durable, and Multifunctional Electrical Insulation Material Systems for High Voltage Applications

Newly developed multilayer structures of well-known polymer insulation materials significantly improved dielectric breakdown voltage, VB, or dielectric strength, K, if well-bonded, when compared to those of single material insulations or the commercial SOA systems, such as Teflon-Kapton-Teflon (TKT), at the same overall thickness. To date, the greatest improvement of the new structures from a few candidate materials, including various types of Kapton PIs and PFA or PET as bond layer (BL), was about 61% higher than that of the Kapton PI alone films, 40.1 vs. 24.9 kV, which was translated to 86.3% decrease in insulation thickness, thus significant volume and weight reduction of the final system. However, it was of interest to note that most improvements of the multilayer structures occurred at thicker overall thicknesses, above ~ 0.15 mm. Extensive analyses also showed that K of the multilayer structures increased with (i) decreasing individual layer thickness regardless of material type, (ii) increasing total accumulated thickness of PI or overall PI/BL ratio, and (iii) increasing number of interface or total number of layers, but only above the aforementioned overall thickness limit. Increases in VB of the multilayer structures were directly correlated with damage evolution and failure mode. With further material-design-process optimizations of the multilayer structures, it was expected to achieve other multifunctionalities, such as high partial discharge (PD) resistance, improved durability, EMI shielding, and high thermal dissipation in addition to high dielectric strength. These new structures can be used in various high voltage and high temperature applications, such as future hybrid or all electric aircraft wiring and power transmission as well as many other non-aerospace high power cables, electronic parts and components, printed circuit board, and so forth. The multilayer insulation system can be easily processed and manufactured with various conductor types via calendaring, compression-molding, stamping, laminating, vacuum-bagging and autoclaving, or 3D printing, even for complex 3-D components. Based on their unique structural configurations and potential capabilities, the new insulation system was identified as micro-multilayer multifunctional electrical insulation (MMEI). Patent application of the MMEI concept and current design configurations was filed for a 1-year provisional application (OAI-58834, Serial No.: 62/659,234), pending conversion to a U.S. utility application. This paper presents details of the MMEI structures, their dielectric performance analyses, potential mechanisms, and commercial scaleup feasibility assessment.

Electric aircrafts↗

Lightweight, Durable, and Multifunctional Electrical Insulation Material Systems for High Voltage Applications

Newly developed multilayer structures of well-known polymer insulation materials significantly improved dielectric breakdown voltage, VB, or dielectric strength, K, if well-bonded, when compared to those of single material insulations or the commercial SOA systems, such as Teflon-Kapton-Teflon (TKT), at the same overall thickness. To date, the greatest improvement of the new structures from a few candidate materials, including various types of Kapton PIs and PFA or PET as bond layer (BL), was about 61% higher than that of the Kapton PI alone films, 40.1 vs. 24.9 kV, which was translated to 86.3% decrease in insulation thickness, thus significant volume and weight reduction of the final system. However, it was of interest to note that most improvements of the multilayer structures occurred at thicker overall thicknesses, above ~ 0.15 mm. Extensive analyses also showed that K of the multilayer structures increased with (i) decreasing individual layer thickness regardless of material type, (ii) increasing total accumulated thickness of PI or overall PI/BL ratio, and (iii) increasing number of interface or total number of layers, but only above the aforementioned overall thickness limit. Increases in VB of the multilayer structures were directly correlated with damage evolution and failure mode. With further material-design-process optimizations of the multilayer structures, it was expected to achieve other multifunctionalities, such as high partial discharge (PD) resistance, improved durability, EMI shielding, and high thermal dissipation in addition to high dielectric strength. These new structures can be used in various high voltage and high temperature applications, such as future hybrid or all electric aircraft wiring and power transmission as well as many other non-aerospace high power cables, electronic parts and components, printed circuit board, and so forth. The multilayer insulation system can be easily processed and manufactured with various conductor types via calendaring, compression-molding, stamping, laminating, vacuum-bagging and autoclaving, or 3D printing, even for complex 3-D components. Based on their unique structural configurations and potential capabilities, the new insulation system was identified as micro-multilayer multifunctional electrical insulation (MMEI). Patent application of the MMEI concept and current design configurations was filed for a 1-year provisional application (OAI-58834, Serial No.: 62/659,234), pending conversion to a U.S. utility application. This paper presents details of the MMEI structures, their dielectric performance analyses, potential mechanisms, and commercial scaleup feasibility assessment.

Multifunctional↗

Establishing and Monitoring an Aseptic Workspace

When are aseptic operations necessary? In order to meet certain bioburden requirements, some components must undergo dry heat microbial reduction (DHMR) or other sterilizing procedures. If sensitive surfaces must be re-exposed after DHMR, this could compromise the bioburden levels. Recontaminating sterilized surfaces could be costly both in time by requiring repeated DHMR and risk to the hardware, which may not be compatible with repeated high temperature bakes. In order to prevent recontamination of the sensitive surfaces, an aseptic environment and sterile technique must be employed. Aseptic environments mean working in a space with almost no detectable bioburden in the air or on surfaces. Ideally, DHMR happens as late as possible to avoid requiring aseptic operations, as it can be considered a high-risk operations. Preparing the cleanroom for aseptic operations Establishing an ISO (International Organization for Standardization) class 5 space to minimize airborne particles. Maintain low bioburden in the cleanroom by using biocidal cleaners. Using multiple biocidal techniques decreases the likelihood of selecting for resistant microorganisms. 70% Isopropyl Alcohol (IPA) denatures the proteins in a microorganism (note: 70% IPA is better at killing microorganisms than 100% IPA) 7% hydrogen peroxide: damages DNA and proteins through oxygen radical damage. Ultraviolet-C (UV-C) lamps: causes crosslinking in DNA which prevents replication. Monitor cleanroom regularly for bioburden trending: Standard bioassay: Swab or wipe samples of cleanroom surfaces processed for colony forming unity (viable or spore selected); Rapid bioassay: Adenosine triphosphate (ATP) or Limulus amebocyte lysate (LAL) for a bioburden snapshot. High levels can signal an immediate re-cleaning before standard bioassay samples are taken. Airborne monitoring: Active (pulling air through a filter) or passive (particle fallout) for bioburden. Verify bioburden levels just before aseptic operation. Test hardware and cleanroom surfaces and air 3 days before the planned aseptic operation. Rapid bioburden just before aseptic operation to ensure room was not re-contaminated. Preparing personnel and tools: Personnel training. Everyone in the cleanroom: Standard cleanroom certification Everyone on the team: 1 day Planetary Protection overview. Aseptic operators only: Half-day aseptic operations training. Covers sterile garmenting/gloves, Sterile handling with a focus on contact transfer risk, tool/GSE preparation, and two-operator system for opening sterilized tools/components. Tool sterilization: All tools to be used during an aseptic operation need to be identified. Compatible tools are sterilized by DHMR or Autoclave. Double wrapped so that the exterior bag can be handled by a non-sterile operator, and the sterile. Tools that are not compatible with high heat do not come in contact with sensitive surfaces: either substitutes are found, or tools are isolated by wrapping in sterile foil. During an aseptic operation. Pre-task to make sure everyone understands the operations, who is handling what, and when the most critical surfaces will be exposed. Monitoring during the operation. Bioburden: active and passive airborne bioburden sampling, glove-tip dabs onto a plate after completion of operation (3 days for results). Particles: real time particle counter constantly running, with alarm for exceeding ISO 5 conditions.

aseptic processing↗

Polymer Matrix Composites Fabrication and Testing

This project involves two separate processes for fabricating carbon fiber composite parts using Hexcel’s RTM6 resin system and Kaneka’s IR-6070 toughened resin system to impregnate carbon fiber tow and weave. These two resins were chosen to model microcracking in parts using RTM6 compared to parts using IR-6070. Plies of the composites were made by painting resin onto 8 harness satin weave or impregnating IM7 12k tow in a prepregging machine. Plies were consolidated using an out-of-autoclave oven or a heat press. Fabrication of the composite parts were conducted with the end goal of sending the composites to be tested and modeled for microcracking. The data will be used for computer modeling in the future.

Miller, Sandi↗

Design of an Automated Ultrasonic Scanning System for In-Situ Composite Cure Monitoring and Defect Detection

The preliminary design and development of an automated ultrasonic scanning system for in-situ composite cure monitoring and defect detection in the high temperature environment of an oven was completed. This preliminary design is a stepping stone to deployment in the high temperature and high pressure environment of an autoclave, the primary cure method of aerospace grade thermoset composites. Cure monitoring with real-time defect detection during the process could determine when defects form and how they move. In addition, real-time defect detection during cure could assist validating physics-based process models for predicting defects at all stages of the cure cycle. A physics-based process model for predicting porosity and fiber waviness originating during cure is currently under development by the NASA Advanced Composites Project (ACP). For the design, an ultrasonic contact scanner is enclosed in an insulating box that is placed inside an oven during cure. Throughout the cure cycle, the box is nitrogen-cooled to approximately room temperature to maintain a standard operating environment for the scanner. The composite part is mounted on the outside of the box in a vacuum bag on the build/tool plate. The build plate is attached to the bottom surface of the box. The scanner inspects the composite panel through the build plate, tracking the movement of defects introduced during layup and searching for new defects that may form during cure. The focus of this paper is the evaluation and selection of the build plate material and thickness. The selection was based on the required operating temperature of the scanner, the cure temperature of the composite material, thermal conductivity models of the candidate build plates, and a series of ultrasonic attenuation tests. This analysis led to the determination that a 63.5 mm thick build plate of borosilicate glass would be utilized for the system. The borosilicate glass plate was selected as the build plate material due to the low ultrasonic attenuation it demonstrated, its ability to efficiently insulate the scanner while supporting an elevated temperature on the part side of the plate, and the availability of a 63.5 mm thick plate without the need for lamination.

Hudson, Tyler B.↗

Reliable Bonding of Composite Laminates Using Reflowable Epoxy Resins

Epoxy matrix composites assembled with adhesives maximize the performance of aerospace structures, but the possibility of forming weak bonds requires the installation of redundant fasteners, which add weight and manufacturing cost. Co-cured joints (e.g. unitized composite structures) are immune to weak bonds because the uncured resin undergoes diffusion and mixing through the joint. A means of co-curing complex structures may reduce the need for redundant fasteners in bondlines. To this end, NASA started the AERoBOND project to develop novel joining materials to enable a “secondary-co-cure” assembly process. Aerospace epoxy resin systems reformulated with offset stoichiometry prevented the resin from advancing beyond the gel point during a conventional autoclave cure cycle up to 180 °C. The offset resins were applied to the joining surfaces of laminate preforms as prepreg. Two surfaces with complimentary offset resins were joined using conventional secondary bonding techniques. Preliminary efforts have indicated that the resulting joint has no discernable interface and appears as a conventional co-cured laminate under optical magnification. This report will discuss the initial work performed regarding formulation of the epoxy resin system using calorimetry, rheology, and mechanical testing.

Palmieri, Frank L.↗

Assured Performance of Additively Manufactured and Composite Parts through Embedded Sensing and Life Cycle Monitoring: An Enabler for in-Space Use

Lightweight composites have a range of applications in aerospace where operational costs and mission (payload) capabilities depend significantly on component weight. Additive manufacturing of the composite components expands the design and production space allowing for complex part geometries. A limiting factor to the utilization of the composites in high value applications, such as aerospace generally, and particularly for in-space applications, is the ability to determine the part quality both at the time of production as well as through the lifetime of the component. Work on monitoring the performance of additively manufactured and autoclaved composites that encompasses the design and manufacturing as well as use in operational environments will be discussed. Optimization of the component design for manufacturability, the use of process monitoring sensors during the component build as well as embedding of carbon nanotube yarn based structural sensors will be described.

Additive Manufacturing↗

Water Shelf Life for Long-Duration Rodent Research Missions

The National Aeronautics and Space Administration Rodent Research Project habitat is a highly-specialized rodent husbandry caging system that enables mice to be flown to the International Space Station for a variety of bioscience studies in the unique microgravity and radiation environment. The habitat accommodates an internal water supply box containing four water access points and two one liter flexible plastic sterile blood bags for storage. Two access points are provided on each side of the habitat, which accommodates five animals per side. Due to the nature of operations on the Space Station – including limited fluid handling – water cannot be changed out weekly as in ground-based vivariums. Water is added to the system a maximum of eighteen months prior to being provided to rodents. The dependable provision of high-quality drinking water is essential for both the welfare of rodents and the scientific integrity of the studies in which they are involved. The robust, multi-stage water preparation process involves the autoclave sterilization of deionized water, the addition of iodine to minimize biofilms, and filtration through a sterile filter to ensure removal of bacteria and other contaminants. The water is then loaded into the sterile blood bags as part of the automated delivery system. A water storage test determined that the shelf life of this water in the habitat could be increased up to four years from a previous eighteen months. This facilitates the ability to pre-position habitats on Station as well as demonstrates that the habitat’s water system can be utilized on future long-duration and deep space missions involving rodents.

Tyler Marsh↗

Consolidation of Braided Carbon Fiber/ Thermoplastic Tubes by Induction Heating

Thermoplastic composites have experienced renewed enthusiasm within the U.S. aerospace industry, due in part to opportunities for rapidly manufacturing large structures. Unlike the lengthy cure cycles required by thermosets, the thermoplastic matrix prepreg requires only heat and pressure to consolidate consecutive layers of material; with sufficient inter-ply contact time to develop a strong interface. The manufacturing requirements for thermoplastics provide manufacturing flexibility and of particular interest are in-situ consolidation processes; i.e consolidation during layup on a tool. In-situ consolidation removes the time-consuming and costly secondary processing step of autoclave or press consolidation. Process variables which contribute to laminate quality include temperature, heat transfer, inter-ply contact time, and consolidation pressure. Most of the work to date related to in-situ consolidation has been in conjunction with automated fiber placement (AFP), where prepreg tows are consolidated when placed on the tool. Considering this process for a braided structure adds complexity relative to AFP due to the rapid lay-down rate of the braider and simultaneous placement of a multiple prepreg tows. Processes considered for consolidation during AFP could not be applied to a braided part. Alternatively, a fully braided preform could be consolidated on the tool using well established thermoplastic welding techniques. The goal of this effort was to evaluate the effectiveness of induction welding to consolidate braided carbon fiber/thermoplastic composite tubes up to eight plies in thickness. The manufacturing process, thermal characterization, and initial mechanical property data of the consolidated tubes are reported.

In-situ consolidation, induction heating/welding, ↗

Laser Angle of Incidence Effects on in-Situ Consolidation of Automated Fiber Placement of Polyaryletherketone Composites

NASA and Electroimpact, Inc. ®†† in conjunction with other U.S. industry partners are performing research as a part of the NASA High-rate Composites for Aircraft Manufacturing (HiCAM) Project to fabricate thermoplastic panels using automated fiber placement (AFP) to increase manufacturing rates of aircraft structural composites. This work focuses on evaluating the in-situ consolidation AFP of thermoplastics (ICAT) process. Previous studies of the ICAT process using semi-crystalline, polyaryletherketone (PAEK) slit-tape have resulted in an adequate degree of intimate contact between plies; however, the resulting interlaminar strength have been less than laminates fabricated in an autoclave. To improve these properties, the effect of reducing the laser angle of incidence (AoI) during placement to increase the degree of auto-hesion was evaluated. The AoI of the laser assisted AFP head was varied between 12° and 16° to fabricate multiple quasi- isotropic and unidirectional test panels. Physics-based thermal models developed at the NASA Langley Research Center were utilized to predict the temperature profile. Laminate processing temperature was measured experimentally, and panel quality was evaluated by both non- destructive evaluation (NDE) as well as destructively by photo-microscopy. The effect on interlaminar strength was determined by short beam strength testing. Test results of carbon fiber laminates fabricated by ICAT using polyetheretherketone (PEEK), polyetherketoneketone (PEKK), and low-melt polyaryletherketone (LM-PAEK) at various laser angles of incidence, placement temperatures and placement speeds are presented.

Laser↗

Thermal Modelling of the in-Situ Consolidation of Automated Fiber Placement of Thermoplastic Composites

NASA is developing carbon fiber reinforced thermoplastic composites processing methods under the Hi-rate Composites Aircraft Manufacturing (HiCAM) project. The in-situ consolidation automated fiber placement (AFP) of thermoplastics (ICAT) process has high potential to increase manufacturing throughput and lower costs as it combines the repeatability and fast lay down rates of AFP with the thermoformability of thermoplastic materials to achieve part consolidation out of the autoclave. Physics-based process models are employed in the ICAT process development to understand, fundamentally, the thermal response of the carbon fiber (CF)/polyaryletherketone (PAEK) material during the rapid heating and cooling associated with laser-assisted AFP. A one-dimensional (1-D) closed-form model was developed capable of predicting the temperature profile through-the-thickness of the tape material. In addition, a two-dimensional (2-D) model was developed to predict the heat transfer through-the-thickness and in the laydown x-direction of the AFP head motion. The solution of the Fourier heat-transfer equations in the 2-D model is approximated using the explicit finite difference numerical method. The temperature profile during placement of PAEK slit-tape materials at various laser target temperatures and placement speeds were measured during ICAT process development trials at Electroimpact®, Inc. †† and the resulting experimental data is compared with the predictions of the 1-D and 2-D models.

Thermoplastics↗

ISS External Microorganisms: A Planetary Protection Experiment to Inform Requirements for Crewed Missions to Mars

We have developed, tested, and flown a caddy capable of collecting aseptic samples from external surfaces of the ISS (International Space Station). The sampling caddy is certified for use during US EVA (extra vehicular activity) and was launched to ISS in the summer of 2023. We are scheduled to collect samples from 6 locations outside ISS during an EVA in May of 2024. We will freeze these samples at -80°C on orbit and return them to Earth. We will then extract and sequence any DNA collected during the EVA using next generation sequencing technologies to characterize the community composition and function of each sample. Measuring the type and quantity of microbes present on the exterior of ISS will allow us to address knowledge gap 2B, “Acceptable levels of microbial/organic releases from humans and support systems” described in a 2019 COSPAR report. Collecting data about microbial release from current crewed vehicles will inform requirements for acceptable leak rates for future crewed missions to Mars. The sampling kit consists of eight commercially available, sterile, DNA free, macrofoam swabs ( 23 mm. diameter ) installed in custom aluminum end effectors. Each end effector is housed in and individual aluminum canister. Each canister contains a 0.2 μm Teflon filter to allow the interior volume to accommodate pressure changes without permitting microbial contaminants to enter the sterile interior volume. A handle repurposed from the space shuttle tile repair kit is used to remove the end effector from the sample canister, collect a sample by swabbing a surface and then replace the end effector in its canister. The canisters and end effectors were cleaned and assembled on Earth. Prior to installing the sterile swab the canisters and end effectors were sterilized in an autoclave at 134°C, 215 kPA, for 7 min.. The final assembly occurred in a sterilized class II biosafety cabinet. We will collect six samples from the 1) airlock vestibule, 2) airlock thermal cover, 3) a gap in the micrometeorite shielding near the airlock, 4) a handrail near the airlock, 5) the CDRA (Carbon Dioxide Removal Assembly) vent, and 6) the VES (Vacuum Exhaust System) vent. The remaining two swabs will be reserved as controls. One swab will be exposed during the EVA without touching any surfaces to act as a blank. The final swab will remain sealed until the entire sampling kit is returned to earth. Based on previously published results from the Russian segment, we hypothesize that there will be detectable microbes at some or all of these locations. Ground-based testing of this sampling caddy confirms that the swabs remain sterile as the canisters transition in and out of vacuum. We were able to retrieve, viable bacterial and fungal cells as well as DNA from samples collected from US space suits during vacuum chamber tests lasting as long as seven hours. Based on these results and feedback from the test subjects the sampling caddy was modified to improve ergonomics and meet US EVA safety requirements. Bayonet probes were added to the sides of the sample kit as alternate mounting points. Additional locking features were added to the end effector and the filter stack to prevent inadvertent release during use. The opening mechanism was changed from one where the end effector was rocked laterally to defeat a ball detent to a twist-to-open threaded closure for similar reasons. Demonstrating, this sampling caddy’s effectiveness during a US EVA will allow us to address knowledge gaps identified in COSPAR reports and begin to define planetary protection requirements for life support systems on crewed missions to mars. This kit could also be used to collect contamination control samples during Artemis missions to verify requirements and could be easily modified for robotic sample collection.

Planetary Protection↗

Thermal Modelling of the In-Situ Consolidation of Automated Fiber Placement Of Thermoplastic Composites

NASA is developing carbon fiber reinforced thermoplastic composites processing methods under the Hi-rate Composites Aircraft Manufacturing (HiCAM) project. The in-situ consolidation automated fiber placement (AFP) of thermoplastics (ICAT) process has high potential to increase manufacturing throughput and lower costs as it combines the repeatability and fast lay down rates of AFP with the thermoformability of thermoplastic materials to achieve part consolidation out of the autoclave. Physics-based process models are employed in the ICAT process development to understand, fundamentally, the thermal response of the carbon fiber (CF)/polyaryletherketone (PAEK) material during the rapid heating and cooling associated with laser-assisted AFP. A one-dimensional (1-D) closed-form model was developed capable of predicting the temperature profile through-the-thickness of the tape material. In addition, a two-dimensional (2-D) model was developed to predict the heat transfer through-the-thickness and in the laydown x-direction of the AFP head motion. The solution of the Fourier heat-transfer equations in the 2-D model is approximated using the explicit finite difference numerical method. The temperature profile during placement of PAEK slit-tape materials at various laser target temperatures and placement speeds were measured during ICAT process development trials at Electroimpact®, Inc. †† and the resulting experimental data is compared with the predictions of the 1-D and 2-D models.

Christopher J. Stelter↗