Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

DOE ART Graphite R&D Program

Graphite overview: Material science, supply chain facts, nuclear material science, licensing thoughts

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The state of the art in hadron beam cooling

Cooling of hadron beams (including heavy-ions) is a powerful technique by which accelerator facilities around the world achieve the necessary beam brightness for their physics research. In this paper, we will give an overview of the latest developments in hadron beam cooling, for which high energy electron cooling at Fermilab's Recycler ring and bunched beam stochastic cooling at Brookhaven National Laboratory's RHIC facility represent two recent major accomplishments. Novel ideas in the field will also be introduced.

43 PARTICLE ACCELERATORS↗

Stencil Computation Optimization and Auto-tuning on State-of-the-Art Multicore Architectures

Understanding the most efficient design and utilization of emerging multicore systems is one of the most challenging questions faced by the mainstream and scientific computing industries in several decades. Our work explores multicore stencil (nearest-neighbor) computations -- a class of algorithms at the heart of many structured grid codes, including PDE solvers. We develop a number of effective optimization strategies, and build an auto-tuning environment that searches over our optimizations and their parameters to minimize runtime, while maximizing performance portability. To evaluate the effectiveness of these strategies we explore the broadest set of multicore architectures in the current HPC literature, including the Intel Clovertown, AMD Barcelona, Sun Victoria Falls, IBM QS22 PowerXCell 8i, and NVIDIA GTX280. Overall, our auto-tuning optimization methodology results in the fastest multicore stencil performance to date. Finally, we present several key insights into the architectural trade-offs of emerging multicore designs and their implications on scientific algorithm development.

97 MATHEMATICS AND COMPUTING↗

Staged Catalytic Partial Oxidation (SCPO) System — The State of Art Integrated Short Contact Time Hydrogen Generator

Research and development on hydrogen and syngas production have great potential in addressing the following challenges in energy arena: (1) produce more clean fuels to meet the increasing demands for clean liquid and gaseous fuels for transportation and electricity generation, (2) increase the efficiency of energy utilization for fuels and electricity production, and (3) eliminate the pollutants and decouple the link between energy utilization and greenhouse gas emissions in end-use systems [Song, 2006, Liu, Song & Subramani 2009]. In this project, GE Global Research (GEGR) collaborated with Argonne National Laboratory (ANL) and the University of Minnesota (UoMn), developed and demonstrated a low cost, compact staged catalytic partial oxidation (SCPO) technology for distributed hydrogen generation. GEGR analyzed different reforming system designs, and developed the SCPO reforming system which is a unique technology staging and integrating 3 different short contact time catalysts in a single, compact reactor: catalytic partial oxidation (CPO), steam methane reforming (SMR) and water-gas shift (WGS). This integration is demonstrated via the fabrication of a prototype scale unit of each key technology. Approaches for key technical challenges of the program includes: • Analyzed different system designs • Designed the SCPO hydrogen production system • Developed highly active and sulfur tolerant CPO catalysts • Designed and built different pilot-scale reactors to demonstrate each key technology • Evaluated different operating conditions · Quantified the efficiency and cost of the system • Developed process design package (PDP) for 1500 kg H 2 /day distributed H 2 production unit. SCPO met the Department of Energy (DOE) and GE’s cost and efficiency targets for distributed hydrogen production.

03 NATURAL GAS↗

Immune targeting of PD-1{sup hi} expressing cells during and after antiretroviral therapy in SIV-infected rhesus macaques

High-level T cell expression of PD-1 during SIV infection is correlated with impaired proliferation and function. We evaluated the phenotype and distribution of T cells and Tregs during antiretroviral therapy plus PD-1 modulation (using a B7-DC-Ig fusion protein) and post-ART. Chronically SIV-infected rhesus macaques received: 11 weeks of ART (Group A); 11 weeks of ART plus B7-DC-Ig (Group B); 11 weeks of ART plus B7-DC-Ig, then 12 weeks of B7-DC-Ig alone (Group C). Continuous B7-DC-Ig treatment (Group C) decreased rebound viremia post-ART compared to pre-ART levels, associated with decreased PD-1{sup hi} expressing T cells and Tregs in PBMCs, and PD-1{sup hi} Tregs in lymph nodes. It transiently decreased expression of Ki67 and α{sub 4}β{sub 7} in PBMC CD4{sup +} and CD8{sup +} Tregs for up to 8 weeks post-ART and maintained Ag-specific T-cell responses at low levels. Continued immune modulation targeting PD-1{sup hi} cells during and post-ART helps maintain lower viremia, keeps a favorable T cell/Treg repertoire and modulates antigen-specific responses. - Highlights: • B7-DC-Ig modulates PD-1{sup hi} cells in SIV-infected rhesus macaques during and post-ART. • Continued PD-1 modulation post-ART maintains PD-1{sup hi} cells at low levels. • Continued PD-1 modulation post-ART maintains a favorable T cell and Treg repertoire.

60 APPLIED LIFE SCIENCES↗

Patterns and Predictors of Early Biochemical Recurrence After Radical Prostatectomy and Adjuvant Radiation Therapy in Men With pT{sub 3}N{sub 0} Prostate Cancer: Implications for Multimodal Therapies

Purpose: The aim of our study was to evaluate patterns and predictors of early biochemical recurrence (eBCR) after radical prostatectomy (RP) and adjuvant radiation therapy (aRT) in order to identify which individuals might benefit from additional treatments. Methods and Materials: We evaluated 390 patients with pT{sub 3}N{sub 0} prostate cancer (PCa) receiving RP and aRT at 6 European centers between 1993 and 2006. Patients who were free from BCR at <2 years' follow-up were excluded. This resulted in 374 assessable patients. Early BCR was defined as 2 consecutive prostate-specific antigen (PSA) test values >0.2 ng/mL within 2 or 3 years after aRT. Uni- and multivariable Cox regression analyses predicting overall and eBCR after aRT were fitted. Covariates consisted of preoperative PSA results, surgical margins, pathological stage, Gleason score, and aRT dose. Results: Overall, 5- and 8-year BCR-free survival rates were 77.1% and 70.8%, respectively. At a median follow-up of 86 months after aRT, 33 (8.8%) and 55 (14.6%) men experienced BCR within 2 or 3 years after aRT, respectively. In multivariable analyses, Gleason scores of 8 to 10 represented the only independent predictor of eBCR after aRT (all, P≤.01). The risk of BCR was significantly higher in patients with a Gleason score of 8 to 10 disease than in those with Gleason 2 to 6 within 24 months after treatment, after adjusting for all covariates (all, P≤.04). However, given a 24-month BCR free period, the risk of subsequent BCR for men with poorly differentiated disease was equal to that of men with less aggressive disease (all, P≥.3). Conclusions: High Gleason score represents the only predictor of eBCR after RP and aRT in patients affected by pT{sub 3}N{sub 0} PCa. Given the association between early PSA recurrence, clinical progression, and mortality, these patients might be considered candidates for adjuvant medical therapy and/or prophylactic whole-pelvis radiation therapy in addition to aRT, delivered to the prostatic bed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-C-204-06: Surface Imaging for the Set-Up of Proton Post-Mastectomy Chestwall Irradiation: Gated Images Vs Non Gated Images

Purpose: Historically, the set-up for proton post-mastectomy chestwall irradiation at our institution started with positioning the patient using tattoos and lasers. One or more rounds of orthogonal X-rays at gantry 0° and beamline X-ray at treatment gantry angle were then taken to finalize the set-up position. As chestwall targets are shallow and superficial, surface imaging is a promising tool for set-up and needs to be investigated Methods: The orthogonal imaging was entirely replaced by AlignRT™ (ART) images. The beamline X-Ray image is kept as a confirmation, based primarily on three opaque markers placed on skin surface instead of bony anatomy. In the first phase of the process, ART gated images were used to set-up the patient and the same specific point of the breathing curve was used every day. The moves (translations and rotations) computed for each point of the breathing curve during the first five fractions were analyzed for ten patients. During a second phase of the study, ART gated images were replaced by ART non-gated images combined with real-time monitoring. In both cases, ART images were acquired just before treatment to access the patient position compare to the non-gated CT. Results: The average difference between the maximum move and the minimum move depending on the chosen breathing curve point was less than 1.7 mm for all translations and less than 0.7° for all rotations. The average position discrepancy over the course of treatment obtained by ART non gated images combined to real-time monitoring taken before treatment to the planning CT were smaller than the average position discrepancy obtained using ART gated images. The X-Ray validation images show similar results with both ART imaging process. Conclusion: The use of ART non gated images combined with real time imaging allows positioning post-mastectomy chestwall patients in less than 3 mm / 1°.

60 APPLIED LIFE SCIENCES↗

Dosimetric Advantages of Four-Dimensional Adaptive Image-Guided Radiotherapy for Lung Tumors Using Online Cone-Beam Computed Tomography

Purpose: This study compares multiple planning techniques designed to improve accuracy while allowing reduced planning target volume (PTV) margins though image-guided radiotherapy (IGRT) with four-dimensional (4D) cone-beam computed tomography (CBCT). Methods and Materials: Free-breathing planning and 4D-CBCT scans were obtained in 8 patients with lung tumors. Four plans were generated for each patient: 3D-conformal, 4D-union, 4D-offline adaptive with a single correction (offline ART), and 4D-online adaptive with daily correction (online ART). For the 4D-union plan, the union of gross tumor volumes from all phases of the 4D-CBCT was created with a 5-mm expansion applied for setup uncertainty. For offline and online ART, the gross tumor volume was delineated at the mean position of tumor motion from the 4D-CBCT. The PTV margins were calculated from the random components of tumor motion and setup uncertainty. Results: Adaptive IGRT techniques provided better PTV coverage with less irradiated normal tissues. Compared with 3D plans, mean relative decreases in PTV volumes were 15%, 39%, and 44% using 4D-union, offline ART, and online ART planning techniques, respectively. This resulted in mean lung volume receiving {>=} 20Gy (V20) relative decreases of 21%, 23%, and 31% and mean lung dose relative decreases of 16%, 26%, and 31% for the 4D-union, 4D-offline ART, and 4D-online ART, respectively. Conclusions: Adaptive IGRT using CBCT is feasible for the treatment of patients with lung tumors and significantly decreases PTV volume and dose to normal tissues, allowing for the possibility of dose escalation. All analyzed 4D planning strategies resulted in improvements over 3D plans, with 4D-online ART appearing optimal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Process-based quality management for clinical implementation of adaptive radiotherapy

Purpose: Intensity-modulated adaptive radiotherapy (ART) has been the focus of considerable research and developmental work due to its potential therapeutic benefits. However, in light of its unique quality assurance (QA) challenges, no one has described a robust framework for its clinical implementation. In fact, recent position papers by ASTRO and AAPM have firmly endorsed pretreatment patient-specific IMRT QA, which limits the feasibility of online ART. The authors aim to address these obstacles by applying failure mode and effects analysis (FMEA) to identify high-priority errors and appropriate risk-mitigation strategies for clinical implementation of intensity-modulated ART. Methods: An experienced team of two clinical medical physicists, one clinical engineer, and one radiation oncologist was assembled to perform a standard FMEA for intensity-modulated ART. A set of 216 potential radiotherapy failures composed by the forthcoming AAPM task group 100 (TG-100) was used as the basis. Of the 216 failures, 127 were identified as most relevant to an ART scheme. Using the associated TG-100 FMEA values as a baseline, the team considered how the likeliness of occurrence (O), outcome severity (S), and likeliness of failure being undetected (D) would change for ART. New risk priority numbers (RPN) were calculated. Failures characterized by RPN ≥ 200 were identified as potentially critical. Results: FMEA revealed that ART RPN increased for 38% (n = 48/127) of potential failures, with 75% (n = 36/48) attributed to failures in the segmentation and treatment planning processes. Forty-three of 127 failures were identified as potentially critical. Risk-mitigation strategies include implementing a suite of quality control and decision support software, specialty QA software/hardware tools, and an increase in specially trained personnel. Conclusions: Results of the FMEA-based risk assessment demonstrate that intensity-modulated ART introduces different (but not necessarily more) risks than standard IMRT and may be safely implemented with the proper mitigations.

60 APPLIED LIFE SCIENCES↗

SU-F-T-592: A Delivery QA-Free Approach for Adaptive Therapy of Prostate Cancer with Static Intensity Modulated Radiotherapy

Purpose: Clinical implementations of adaptive radiotherapy (ART) are limited mainly by the requirement of delivery QA (DQA) prior to the treatment. Small segment size and small segment MU are two dominant factors causing failures of DQA. The aim of this project is to explore the feasibility of ART treatment without DQA by using a partial optimization approach. Methods: A retrospective simulation study was performed on two prostate cancer patients treated with SMLC-IMRT. The prescription was 180cGx25 fractions with daily CT-on-rail imaging for target alignment. For each patient, seven daily CTs were selected randomly across treatment course. The contours were deformablely transferred from the simulation CT onto the daily CTs and modified appropriately. For each selected treatment, dose distributions from original beams were calculated on the daily treatment CTs (DCT plan). An ART plan was also created by optimizing the segmental MU only, while the segment shapes were preserved and the minimum MU constraint was respected. The overlaps, between PTV and the rectum, between PTV and the bladder, were normalized by the PTV volume. This ratio was used to characterize the difficulty of organs-at-risk (OAR) sparing. Results: Comparing to the original plan, PTV coverage was compromised significantly in DCT plans (82% ± 7%) while all ART plans preserved PTV coverage. ART plans showed similar OAR sparing as the original plan, such as V40Gy=11.2cc (ART) vs 11.4cc (original) for the rectum and D10cc=4580cGy vs 4605cGy for the bladder. The sparing of the rectum/bladder depends on overlap ratios. The sparing in ART was either similar or improved when overlap ratios in treatment CTs were smaller than those in original plan. Conclusion: A partial optimization method is developed that may make the real-time ART feasible on selected patients. Future research is warranted to quantify the applicability of the proposed method.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-11: Sparse-View CT Reconstruction Via a Novel Non-Local Means Method

Purpose: Sparse-view computed tomography (CT) reconstruction is an effective strategy to reduce the radiation dose delivered to patients. Due to its insufficiency of measurements, traditional non-local means (NLM) based reconstruction methods often lead to over-smoothness in image edges. To address this problem, an adaptive NLM reconstruction method based on rotational invariance (RIANLM) is proposed. Methods: The method consists of four steps: 1) Initializing parameters; 2) Algebraic reconstruction technique (ART) reconstruction using raw projection data; 3) Positivity constraint of the image reconstructed by ART; 4) Update reconstructed image by using RIANLM filtering. In RIANLM, a novel similarity metric that is rotational invariance is proposed and used to calculate the distance between two patches. In this way, any patch with similar structure but different orientation to the reference patch would win a relatively large weight to avoid over-smoothed image. Moreover, the parameter h in RIANLM which controls the decay of the weights is adaptive to avoid over-smoothness, while it in NLM is not adaptive during the whole reconstruction process. The proposed method is named as ART-RIANLM and validated on Shepp-Logan phantom and clinical projection data. Results: In our experiments, the searching neighborhood size is set to 15 by 15 and the similarity window is set to 3 by 3. For the simulated case with a resolution of 256 by 256 Shepp-Logan phantom, the ART-RIANLM produces higher SNR (35.38dB<24.00dB) and lower MAE (0.0006<0.0023) reconstructed image than ART-NLM. The visual inspection demonstrated that the proposed method could suppress artifacts or noises more effectively and preserve image edges better. Similar results were found for clinical data case. Conclusion: A novel ART-RIANLM method for sparse-view CT reconstruction is presented with superior image. Compared to the conventional ART-NLM method, the SNR and MAE from ART-RIANLM increases 47% and decreases 74%, respectively.

60 APPLIED LIFE SCIENCES↗

CD8 + lymphocyte control of SIV infection during antiretroviral therapy

CD8 + lymphocytes play an important role in suppressing in vivo viral replication in HIV infection. However, both the extent to which and the mechanisms by which CD8 + lymphocytes contribute to viral control are not completely understood. A recent experiment depleted CD8 + lymphocytes in simian immunodeficiency virus (SIV)-infected rhesus macaques (RMs) on antiretroviral treatment (ART) to study the role of CD8 + lymphocytes. CD8 + lymphocytes depletion resulted in temporary plasma viremia in all studied RMs. Viral control was restored when CD8 + lymphocytes repopulated. We developed a viral dynamic model to fit the viral load (VL) data from the CD8 depletion experiment. We explicitly modeled the dynamics of the latent reservoir and the SIV-specific effector cell population including their exhaustion and their potential cytolytic and noncytolytic functions. We found that the latent reservoir significantly contributes to the size of the peak VL after CD8 depletion, while drug efficacy plays a lesser role. Our model suggests that the overall CD8 + lymphocyte cytolytic killing rate is dynamically changing depending on the levels of antigen-induced effector cell activation and exhaustion. Based on estimated parameters, our model suggests that before ART or without ART the overall CD8 cytolytic killing rate is small due to exhaustion. However, after the start of ART, the overall CD8 cytolytic killing rate increases due to an expansion of SIV-specific CD8 effector cells. Further, we estimate that the cytolytic killing rate can be significantly larger than the cytopathic death rate in some animals during the second phase of ART-induced viral decay. Lastly, our model provides a new explanation for the puzzling findings by Klatt et al. and Wong et al. that CD8 depletion done immediately before ART has no noticeable effect on the first phase viral decay slope seen after ART initiation Overall, by incorporating effector cells and their exhaustion, our model can explain the effects of CD8 depletion on VL during ART, reveals a detailed dynamic role of CD8 + lymphocytes in controlling viral infection, and provides a unified explanation for CD8 depletion experimental data.

59 BASIC BIOLOGICAL SCIENCES↗

Museum security and the Thomas Crown Affair.

Over the years, I've daydreamed about stealing a Vermeer, a Picasso, or Rembrandt. It tickles me, as much as watching the reboot of The Thomas Crown Affair. Why is it, do you suppose, so much fun to think about stealing a world renowned piece off the wall of a major metropolitan museum? Is it the romantic thoughts of getting away with it, walking past infrared detectors, and pressure sensors ala Indiana Jones with the sack of sand to remove the idol without triggering the security system? Is it the idea of snatching items with such fantastic prices, where the romance of possessing an item of such value is less intoxicating than selling it to a private collector for it to never be seen again? I suspect others share my daydreams as they watch theater or hear of a brazen daylight heist at museums around the world, or from private collections. Though when reality sets in, the mind of the security professional kicks in. How could one do it, why would one do it, what should you do once it's done? The main issue a thief confronts when acquiring unique goods is how to process or fence them. They become very difficult to sell because they are one-of-a-kind, easy to identify, and could lead to the people involved with the theft. The whole issue of museum security takes up an ironic twist when one considers the secretive British street artist 'Banksy'. Banksy has made a name for himself by brazenly putting up interesting pieces of art in broad daylight (though many critics don't consider his work to be art) on building walls, rooftops, or even museums. I bring him up for a interesting take on what may become a trend in museum security. In March of 2005, Banksy snuck a piece of his called 'Vandalized Oil Painting' into the Brooklyn Museum's Great Historical Painting Wing, plus 3 other pieces into major museums in New York. Within several days, 2 paintings had been torn down, but 2 stayed up much longer. In his home country of the UK, a unauthorized piece he created and placed in the British Museum known as 'Early Man Goes to Market' received different treatment when placed inside the walls. It was adopted into the permanent collection! I like his story because it's so counter-intuitive. Who would have thought that modern museum security might involve preventing people not just from stealing art, but from sneaking 'unauthorized' art into museums? What is next, tampering with the archive records in order to make it look like the piece in question has always been there? To learn more about museum security, I interviewed multiple experts in the field. It turns out that the glamorous lifestyle of Thomas Crown is not particularly relevant. In fact, usually nobody can point to a Mr. Big of the underworld coordinating thefts, though some organized crime families have been known to use stolen art as black market chips to trade. The common consensus among experts in the field of art theft is that, instead of most high-value pieces being stolen by outsiders with a blue print in hand and rappelling from a ceiling skylight, in reality, 80 percent of art thefts involve insiders or accomplices that execute the crime over a period of time while working or volunteering in the museum. Indeed, according to FBI statistics, between 70 and 80 percent of all solved art theft cases involve insider participation of some kind, yet according to Tom Cremers of the Musuem Security Network, 'Having been involved in risk assessments in over hundreds of museums over the past ten years, it is quite astonishing how rarely the risk of insider participation is discussed.' In regards to the insider threat, a museum is not much different from any corporation or other organization. There are directors, employees, interns, and cleaning staff (very often outsourced), security guards (again outsourced, typically with very high turnover rates). Unlike corporations, most museums also have volunteer staff, docents, and authorized visiting scholars. All these people can potentially take advantage of their position, or to be exploited by a clever attacker on the outside or inside using social engineering. After discussing where museum security is headed with several people involved in the field, the consensus seems to be that it is going to be completely digital at the behest of companies designing new security products. By this I mean that nearly every security sensor and alarm is being designed so that it is compatible or adaptable to Cat 5/6 Ethernet cable. Museum security sensors are usually connected to the network infrastructure, which then gets tied back to a server monitoring the security sensors. This approach should make us feel uneasy. This is security that rides on top of technology that time and time again has proven to be highly vulnerable, and very often implemented by closed source vendors who do not release details of their code or hardware because of it being proprietary. Being proprietary is not consistent with having good security.

99 GENERAL AND MISCELLANEOUS↗

Adaptive Radiotherapy for Locally Advanced Non-Small-Cell Lung Cancer Does Not Underdose the Microscopic Disease and has the Potential to Increase Tumor Control

Purpose: To evaluate doses to the microscopic disease (MD) in adaptive radiotherapy (ART) for locally advanced non-small-cell lung cancer (NSCLC) and to model tumor control probability (TCP). Methods and Materials: In a retrospective planning study, three-dimensional conformal treatment plans for 13 patients with locally advanced NSCLC were adapted to shape and volume changes of the gross tumor volume (GTV) once or twice during conventionally fractionated radiotherapy with total doses of 66 Gy; doses in the ART plans were escalated using an iso-mean lung dose (MLD) approach compared to non-adapted treatment. Dose distributions to the volumes of suspect MD were simulated for a scenario with synchronous shrinkage of the MD and GTV and for a scenario of a stationary MD despite GTV shrinkage; simulations were performed using deformable image registration. TCP calculations considering doses to the GTV and MD were performed using three different models. Results: Coverage of the MD at 50 Gy was not compromised by ART. Coverage at 60 Gy in the scenario of a stationary MD was significantly reduced from 92% {+-} 10% to 73% {+-} 19% using ART; however, the coverage was restored by iso-MLD dose escalation. Dose distributions in the MD were sufficient to achieve a TCP >80% on average in all simulation experiments, with the clonogenic cell density the major factor influencing TCP. The combined TCP for the GTV and MD was 19.9% averaged over all patients and TCP models in non-adaptive treatment with 66 Gy. Iso-MLD dose escalation achieved by ART increased the overall TCP by absolute 6% (adapting plan once) and by 8.7% (adapting plan twice) on average. Absolute TCP values were significantly different between the TCP models; however, all TCP models suggested very similar TCP increase by using ART. Conclusions: Adaptation of radiotherapy to the shrinking GTV did not compromise dose coverage of volumes of suspect microscopic disease and has the potential to increase TCP by >40% compared with radiotherapy planning without ART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adjuvant Radiation Therapy for Margin-Positive Vulvar Squamous Cell Carcinoma: Defining the Ideal Dose-Response Using the National Cancer Data Base

Purpose: Positive surgical margins after radical vulvectomy for vulvar cancer portend a high risk for local relapse, which may be challenging to salvage. We assessed the impact of adjuvant radiation therapy (aRT) on overall survival (OS) and the dose-response relationship using the National Cancer Data Base. Methods and Materials: Patients with vulvar squamous cell carcinoma who underwent initial extirpative surgery with positive margins from 1998 to 2012 were included. Factors associated with aRT and specific dose levels were analyzed using logistic regression. Log-rank and multivariable Cox proportional hazards modeling were used for OS analysis. Results: We identified 3075 patients with a median age of 66 years (range, 22-90 years); the median follow-up time was 36.4 months (interquartile range [IQR] 15.4-71.0 months). Stage IA/B disease represented 41.2% of the cohort. Sixty-three percent underwent lymph node assessment, with a 45% positivity rate. In total, 1035 patients (35.3%) received aRT, with a median dose of 54.0 Gy (IQR 48.6-60.0 Gy). The 3-year OS improved from 58.5% to 67.4% with aRT (P<.001). On multivariable analysis, age, Charlson-Deyo score ≥1, stage ≥II, tumors ≥4 cm, no aRT, and adverse nodal characteristics led to inferior survival. Dose of aRT was positively associated with OS as a continuous variable on univariate analysis (P<.001). The unadjusted 3-year OS for dose subsets 30.0 to 45.0 Gy, 45.1 to 53.9 Gy, 54.0 to 59.9 Gy, and ≥60 Gy was 54.3%, 55.7%, 70.1%, and 65.3%, respectively (P<.001). Multivariable analysis using a 4-month conditional landmark revealed that the greatest mortality reduction occurred in cumulative doses ≥54 Gy: 45.1 to 53.9 Gy (hazard ratio [HR] 0.94, P=.373), 54.0 to 59.9 Gy (HR 0.75, P=.024), ≥60 Gy (HR 0.71, P=.015). No survival benefit was seen with ≥60 Gy compared with 54.0 to 59.9 Gy (HR 0.95, P=.779). Conclusions: Patients with vulvar squamous cell carcinoma and positive surgical margins derive an OS benefit from aRT with a seemingly optimal dose in the range of 54.0 to 59.9 Gy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric evaluation of a three-phase adaptive radiotherapy for nasopharyngeal carcinoma using helical tomotherapy

Adaptive radiotherapy (ART) has been introduced to correct the radiation-induced anatomic changes in head and neck cases during a treatment course. This study evaluated the potential dosimetric benefits of applying a 3-phase adaptive radiotherapy protocol in nasopharyngeal carcinoma (NPC) patients compared with the nonadaptive single-phase treatment protocol. Ten NPC patients previously treated with this 3-phase radiation protocol using Hi-Art Tomotherapy were recruited. Two new plans, PII-ART and PIII-ART, were generated based on the up-to-date computed tomography (CT) images and contours and were used for treatment in phase two (PII; after 25th fraction) and phase three (PIII; after 35th fraction), respectively. To simulate the situation of no replanning, 2 hybrid plans denoted as PII-NART and PIII-NART were generated using the original contours pasted on the PII- and PIII-CT sets by CT-CT fusion. Dosimetric comparisons were made between the NART plans and the corresponding ART plans. In both PII- and PIII-NART plans, the doses to 95% of all the target volumes (D{sub 95}) were increased with better dose uniformity, whereas the organs at risk (OARs) received higher doses compared with the corresponding ART plans. Without replanning, the total dose to 1% of brainstem and spinal cord (D{sub 1}) significantly increased 7.87 {+-} 7.26% and 10.69 {+-} 6.72%, respectively (P = 0.011 and 0.001, respectively), in which 3 patients would have these structures overdosed when compared with those with two replannings. The total maximum doses to the optic chiasm and pituitary gland and the mean doses to the left and right parotid glands were increased by 10.50 {+-} 10.51%, 8.59 {+-} 6.10%, 3.03 {+-} 4.48%, and 2.24 {+-} 3.11%, respectively (P = 0.014, 0.003, 0.053, and 0.046, respectively). The 3-phase radiotherapy protocol showed improved dosimetric results to the critical structures while keeping satisfactory target dose coverage, which demonstrated the advantages of ART in helical tomotherapy of NPC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Biphasic decay of intact SHIV genomes following initiation of antiretroviral therapy complicates analysis of interventions targeting the reservoir

The latent reservoir for HIV-1 in resting CD4 + T cells persists despite antiretroviral therapy (ART) and precludes cure. Reservoir-targeting interventions are evaluated in ART-treated macaques infected with simian immunodeficiency virus (SIV) or simian-human immunodeficiency virus (SHIV). Efficacy is determined by reservoir measurements before and after the intervention. However, most proviruses persisting in the setting of ART are defective. In addition, intact HIV-1 and SIV genomes undergo complex, multiphasic decay observable when new infection events are blocked by ART. Intervention-induced elimination of latently infected cells must be distinguished from natural decay. Here, we address these issues for SHIV. We describe an intact proviral DNA assay that allows digital counting of SHIV genomes lacking common fatal defects. We show that intact SHIV genomes in circulating CD4 + T cells undergo biphasic decay during the first year of ART, with a rapid first phase (t 1/2 = 30.1 d) and a slower second phase (t 1/2 = 8.1 mo) that is still more rapid that the slow decay observed in people with HIV-1 on long-term ART (t 1/2 = 3.7 y). In SHIV models, most interventions are tested during 2nd phase decay. Natural 2nd phase decay must be considered in evaluating interventions as most infected cells present at this time do not become part of the stable reservoir. In addition, for interventions tested during 2nd phase decay, a caveat is that the intervention may not be equally effective in people with HIV on long-term ART whose reservoirs are dominated by latently infected cells with a slower decay rate.

59 BASIC BIOLOGICAL SCIENCES↗

Multi-dose Romidepsin Reactivates Replication Competent SIV in Post-antiretroviral Rhesus Macaque Controllers

Viruses that persist despite seemingly effective antiretroviral treatment (ART) and can reinitiate infection if treatment is stopped preclude definitive treatment of HIV-1 infected individuals, requiring lifelong ART. Among strategies proposed for targeting these viral reservoirs, the premise of the “shock and kill” strategy is to induce expression of latent proviruses [for example with histone deacetylase inhibitors (HDACis)] resulting in elimination of the affected cells through viral cytolysis or immune clearance mechanisms. Yet, ex vivo studies reported that HDACis have variable efficacy for reactivating latent proviruses, and hinder immune functions. We developed a nonhuman primate model of post-treatment control of SIV through early and prolonged administration of ART and performed in vivo reactivation experiments in controller RMs, evaluating the ability of the HDACi romidepsin (RMD) to reactivate SIV and the impact of RMD treatment on SIV-specific T cell responses. Ten RMs were IV-infected with a SIVsmmFTq transmitted-founder infectious molecular clone. Four RMs received conventional ART for >9 months, starting from 65 days post-infection. SIVsmmFTq plasma viremia was robustly controlled to <10 SIV RNA copies/mL with ART, without viral blips. At ART cessation, initial rebound viremia to ~10 6 copies/mL was followed by a decline to < 10 copies/mL, suggesting effective immune control. Three post-treatment controller RMs received three doses of RMD every 35–50 days, followed by in vivo experimental depletion of CD8 + cells using monoclonal antibody M-T807R1. RMD was well-tolerated and resulted in a rapid and massive surge in T cell activation, as well as significant virus rebounds (~10 4 copies/ml) peaking at 5–12 days post-treatment. CD8 + cell depletion resulted in a more robust viral rebound (10 7 copies/ml) that was controlled upon CD8 + T cell recovery. Our results show that RMD can reactivate SIV in vivo in the setting of post-ART viral control. Comparison of the patterns of virus rebound after RMD administration and CD8 + cell depletion suggested that RMD impact on T cells is only transient and does not irreversibly alter the ability of SIV-specific T cells to control the reactivated virus.

Microbiology↗