Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AMPLIFIER DESIGN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 523 records · Page 29

Integrated circuit electrometer and sweep circuitry for an atmospheric probe

The design of electrometer circuitry using an integrated circuit operational amplifier with a MOSFET input is described. Input protection against static voltages is provided by a dual ultra low leakage diode or a neon lamp. Factors affecting frequency response leakage resistance, and current stability are discussed, and methods are suggested for increasing response speed and for eliminating leakage resistance and current instabilities. Based on the above, two practical circuits, one having a linear response and the other a logarithmic response, were designed and evaluated experimentally. The design of a sweep circuit to implement mobility measurements using atmospheric probes is presented. A triangular voltage waveform is generated and shaped to contain a step in voltage from zero volts in both positive and negative directions.

Zimmerman, L. E.↗

Amplified detection of single base mismatches with the competing-strand assay reveals complex kinetic and thermodynamic behavior of strand displacement at the electrode surface

Detection of single-base mismatches with respect to a probe strand has been a predominant pursuit in electrochemical biosensor efforts, due to links found between single nucleotide polymorphisms (SNPs) and the predisposition to various diseases. We report an osmium tetroxide bipyridine-based, thermally-controlled, competitive-strand electrochemical assay to allow amplified detection of single-base mismatches. Optimally designed competitive-strand displacement and hybridization temperature allows us to distinguish the single-mismatched-target from the fully complementary sequence with unambiguous, highly reproducible, robust signal differences of over 90%. Furthermore, we find a complex interplay between the position of the redox label, variations in strand displacement kinetics due to mismatches incorporated into the competitive strand, and alterations in the melting temperature of DNA duplexes tethered on the gold surface, when probed by square-wave voltammetry. Furthermore, these insights will apply to any surface-tethered DNA-based electrochemical biosensor, and can help with understanding complex phenomena involved in these types of assays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Initial operation of a pulse-burst laser system for high-repetition-rate Thomson scattering

A pulse-burst laser has been installed for Thomson scattering measurements on the Madison Symmetric Torus reversed-field pinch. The laser design is a master-oscillator power-amplifier. The master oscillator is a commercial Nd:YVO{sub 4} laser (1064 nm) which is capable of Q-switching at frequencies between 5 and 250 kHz. Four Nd:YAG (yttrium aluminum garnet) amplifier stages are in place to amplify the Nd:YVO{sub 4} emission. Single pulses through the Nd:YAG amplifier stages gives energies up to 1.5 J and the gain for each stage has been measured. Repetitive pulsing at 10 kHz has also been performed for 2 ms bursts, giving average pulse energies of 0.53 J with {Delta}E/E of 4.6%, where {Delta}E is the standard deviation between pulses. The next step will be to add one of two Nd:glass (silicate) amplifier stages to produce final pulse energies of 1-2 J for bursts up to 250 kHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On optimization of sub-THz gyrotron parameters

The theory is developed describing how the optimization of gyrotron parameters should be done taking into account two effects deteriorating the gyrotron efficiency: the spread in electron velocities and the spread in the guiding center radii. The paper starts from qualitative analysis of the problem. This simplified theory is used for making some estimates for a specific gyrotron design. The same design is then studied by using more accurate numerical methods. Results of the latter treatment agree with former qualitative predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance studies of Hamamatsu R9800 photomultiplier tube with a new active base designed for use in the Hall D Broadband tagger Hodoscope

This paper presents the results of a study of a high rate photomultiplier and active base assembly designed for use in scintillator counters of the Hall D Jefferson Lab Broadband fixed-array Tagging Hodoscope. In its standard configuration the fixed-array hodoscope consists of 218 plastic scintillator counters made with Hamamatsu R9800 one inch in diameter photomultiplier tube. All tubes are equipped with designed at JLab new active base. The base comprised of a high voltage divider integrated with amplifiers powered by current flowing through the divider (U.S. Patent No. 6,791,269). This original design allows limiting the PMT anode current to 15-20 uA at a 4 MHz count rate, and allows tube operation at lower high voltage bias voltage while retaining a desired overall gain and dynamic range of output signals. The performance of the PMT assemblies were studied at Jeffeson Lab using a picosecond laser (PLP-10). Subsequently, two hundred fifty PMT and base assemblies were manufactured and tested. The results of testing the R9800 photomultiplier in a new active base are presented and discussed.

Popov, Vladimir↗

Towards new functional nanostructures for medical imaging

Nanostructures represent a promising new type of contrast agent for clinical medical imaging modalities, including magnetic resonance imaging, x-ray computed tomography, ultrasound, and nuclear imaging. Currently, most nanostructures are simple, single-purpose imaging agents based on spherical constructs (e.g., liposomes, micelles, nanoemulsions, macromolecules, dendrimers, and solid nanoparticle structures). In the next decade, new clinical imaging nanostructures will be designed as multi-functional constructs, to both amplify imaging signals at disease sites and deliver localized therapy. Proposals for nanostructures to fulfill these new functions will be outlined. New functional nanostructures are expected to develop in five main directions: Modular nanostructures with additive functionality; cooperative nanostructures with synergistic functionality; nanostructures activated by their in vivo environment; nanostructures activated by sources outside the patient; and novel, nonspherical nanostructures and components. The development and clinical translation of next-generation nanostructures will be facilitated by a combination of improved clarity of the in vivo imaging and biological challenges and the requirements to successfully overcome them; development of standardized characterization and validation systems tailored for the preclinical assessment of nanostructure agents; and development of streamlined commercialization strategies and pipelines tailored for nanostructure-based agents for their efficient translation to the clinic.

60 APPLIED LIFE SCIENCES↗

Modeling of a Compact Terahertz Source based on the Two-Stream Instability

THz radiation straddles the microwave and infrared bands of the electromagnetic spectrum, thus combining the penetrating power of lower-frequency waves and imaging capabilities of higher-energy infrared radiation. THz radiation is employed in various elds such as cancer research, biology, agriculture, homeland security, and environmental monitoring. Conventional vacuum electronic sources of THz radiation (e.g., fast- and slow-wave devices) either require very small structures or are bulky and expensive to operate. Optical sources necessitate cryogenic cooling and are presently capable of producing milliwatt levels of power at THz frequencies. We propose a millimeter and sub-millimeter wave source based on a well-known phenomenon called the two-stream instability. The two-beam source relies on lowenergy and low-current electron beams for operation. Also, it is compact, simple in design, and does not contain expensive parts that require complex machining and precise alignment. In this dissertation, we perform 2-D particle-in-cell (PIC) simulations of the interaction region of the two-beam source. The interaction region consists of a beam pipe of radius ra and two electron beams of radius rb co-propagating and interacting inside the pipe. The simulations involve the interaction of unmodulated (no initial energy modulation) and modulated (energy-modulated, seeded at a given frequency) electron beams. In addition, both cold (monoenergetic) and warm (Gaussian) beams are treated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Novel Laser and Diagnostic Technologies for the OMEGA EP High-Energy Petawatt Laser

OMEGA EP (extended performance) is a petawatt-class laser facility that includes two NIF-like beamlines designed to operate in a chirped-pulse-amplifi cation mode to produce up to 2.6 kJ in a pulsewidth range of <1 to 100 ps at 1,053 nm. The OMEGA EP performance and the laser engineering of enabling technologies required to meet these goals are discussed.

chirped pulse amplification↗

LSST Commissioning Camera

The LSST Commissioning Camera (LSSTComCam) was mounted on the Simonyi Survey Telescope in August 2022 and observed for seven weeks in late 2024 until it was removed from the telescope in December 2024. It is a smaller, fully functional version of LSSTCam, with only the central raft of 9 4k x 4k CCDs (all ITL sensors) and comprising 144 megapixels. Every CCD has 16 amplifiers, each reading 1 million pixels. LSSTComCam was designed to enable end-to-end testing of the observatory’s systems, including data acquisition, image processing, and observatory operations.

79 ASTRONOMY AND ASTROPHYSICS↗

Quad aperture RF definition

A single STS package 118 m diameter hoop/column antenna is capable of providing service for appr. 250,000 mobile users. The selected quad aperture configuration is able to provide at least 25 db C/I without cable blockage, column scatter, coupling between quad apertures, and tolerance effects. A feed can be designed which uses single polarized radiating elements while the overall system employs dual polarization. The quad aperture concept can eliminate the use of diplexers and their associated losses. The critical technology issues in the RF area include the design of the radiating elements, BFN, monolithic power amplifiers and receiver front end, tolerance control and packaging of the feed.

Foldes, P.↗

Maser radiometer for cosmic background radiation anisotropy measurements

A maser amplifier was incorporated into a low noise radiometer designed to measure large-scale anisotropy in the 3 deg K microwave background radiation. To minimize emission by atmospheric water vapor and oxygen, the radiometer is flown in a small balloon to an altitude to 25 km. Three successful flights were made - two from Palestine, Texas and one from Sao Jose dos Campos, Brazil. Good sky coverage is important to the experiment. Data from the northern hemisphere flights has been edited and calibrated.

Fixsen, D. J.↗

The PDS-VAX intelligent plate scanning system of Trieste Astronomical Observatory

An intelligent subsystem for interfacing a PDS1010A digital microdensitometer to a DEC DR11W DMA 16 bit UNIBUS port in DEC VAX VMS environment was tested. The subsystem employs two MOTOROLA M68000 microprocessors with 128 KB data memory. The PDS primitives and the user defined high level scanning functions and preprocessing modules are loaded from the host computer into two 8 KB RAM memories in the microprocessors using a dedicated PDS control language. The subsystem is planned to employ a nonstandard photomultiplier electronics. Two design schemes were tested: (1) based on three amplifiers of gain 10 cascaded and multiplexed to a 12 bit AD converter, and (2) based on a single amplifier of gain 100 and two 14 bit AD converters.

Pucillo, M.↗

Three-Axis Superconducting Gravity Gradiometer

Gravity gradients measured even on accelerating platforms. Three-axis superconducting gravity gradiometer based on flux quantization and Meissner effect in superconductors and employs superconducting quantum interference device as amplifier. Incorporates several magnetically levitated proof masses. Gradiometer design integrates accelerometers for operation in differential mode. Principal use in commercial instruments for measurement of Earth-gravity gradients in geo-physical surveying and exploration for oil.

Paik, Ho Jung↗

Steady-state evoked potentials possibilities for mental-state estimation

The use of the human steady-state evoked potential (SSEP) as a possible measure of mental-state estimation is explored. A method for evoking a visual response to a sum-of-ten sine waves is presented. This approach provides simultaneous multiple frequency measurements of the human EEG to the evoking stimulus in terms of describing functions (gain and phase) and remnant spectra. Ways in which these quantities vary with the addition of performance tasks (manual tracking, grammatical reasoning, and decision making) are presented. Models of the describing function measures can be formulated using systems engineering technology. Relationships between model parameters and performance scores during manual tracking are discussed. Problems of unresponsiveness and lack of repeatability of subject responses are addressed in terms of a need for loop closure of the SSEP. A technique to achieve loop closure using a lock-in amplifier approach is presented. Results of a study designed to test the effectiveness of using feedback to consciously connect humans to their evoked response are presented. Findings indicate that conscious control of EEG is possible. Implications of these results in terms of secondary tasks for mental-state estimation and brain actuated control are addressed.

Junker, Andrew M.↗

Electro-optic network analyzer

The bandwidth of frequency domain measurement methods of electrical signals has usually been far greater than the bandwidth of time domain methods. The primary limits of the time domain approach have been the 20 to 30 GHz bandwidth limit for electronic waveform acquisition instrumentation, and the lack of usable electrical pulse generators for excitation of a test device. The bandwidth of frequency domain network analysis appears to have reached a plateau of between 100 to 200 GHz, while time domain measurement have improved markedly in both bandwidth and sensitivity with the introduction of the pulsed laser based electro-optic sampling approach. Network analysis or the measurement of device scattering parameters provides information necessary to the design of electronic network such as high frequency amplifiers, mixers, and phase shifter. The bandwidth of frequency domain network analysis is currently being exceeded by the next generations of high frequency transistors and devices. Thus the electro-optic approach is a natural means of extending network analysis into the range above 100 GHz by employing time domain methods. In this approach, a suitable electrical excitation pulse is generated and propagated along a transmission line toward a test device. In the picosecond domain, laser driven photoconductive switches provide a unique method of generating electrical transients. Several materials were studied for generating short electrical pulses using photoconductive switches. The various semiconductive materials tested for photoconductive switching, and the electro-optic measurement technique used to characterize the material performance are described.

Jackson, Todd A.↗

Laser transmitter for Lidar In-Space Technology Experiment

The Lidar In-Space Technology Experiment (LITE) Laser Transmitter Module (LTM) flight laser optical architecture has been space qualified by extensive testing at the system, subsystem and component level. The projected system output performance has been verified using an optically and electrically similar breadboard version of the laser. Parasitic lasing was closely examined and completely suppressed after design changes were implemented and tested. Oscillator and amplifier type heads were separately tested to 150 million shots. Critical subassemblies have undergone environmental testing to Shuttle qualification levels. A superior three color anti-reflection coating was developed and tested for use on 14 surfaces after the final amplifier.

Chang, John↗

Fabry-Perot Interferometer-Based Electrooptic Modulator using LiNbO3 and Organic Thin Films

We report the study of a Fabry-Perot electro-optical modulator using thin crystalline film NPP, and Crystalline LiNbO3. We are able to observe 14, and 60 percent degree of modulation. Measurements were carried using a standard lock-in amplifier with a silicon detector. The proposal to design a Fabry-Perot electro-optic modulator with an intracavity electro-optically active organic material was based on the initial results using poled polymer thin films. The main feature of the proposed device is the observation that in traditional electrooptic modulators like a Packets cell, it requires few kilovolts of driving voltage to cause a 3 dB modulation even in high figure-of-merit electrooptic materials like LiNbO3. The driving voltage for the modulator can be reduced to as low as 10 volts by introducing the electrooptic material inside die resonant cavity of a Fabry-Perot modulator. This is because the transmission of the Fabry-Perot cavity varies nonlinearly with the change of refractive index or phase of light due to applied electric field.

Banks, C.↗