Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “volume determination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Determination of hydrogen cluster velocities and comparison with numerical calculations

The use of powerful hydrogen cluster jet targets in storage ring experiments led to the need of precise data on the mean cluster velocity as function of the stagnation temperature and pressure for the determination of the volume density of the target beams. For this purpose a large data set of hydrogen cluster velocity distributions and mean velocities was measured at a high density hydrogen cluster jet target using a trumpet shaped nozzle. The measurements have been performed at pressures above and below the critical pressure and for a broad range of temperatures relevant for target operation, e.g., at storage ring experiments. The used experimental method is described which allows for the velocity measurement of single clusters using a time-of-flight technique. Since this method is rather time-consuming and these measurements are typically interfering negatively with storage ring experiments, a method for a precise calculation of these mean velocities was needed. For this, the determined mean cluster velocities are compared with model calculations based on an isentropic one-dimensional van der Waals gas. Based on the obtained data and the presented numerical calculations, a new method has been developed which allows to predict the mean cluster velocities with an accuracy of about 5%. For this two cut-off parameters defining positions inside the nozzle are introduced, which can be determined for a given nozzle by only two velocity measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative microinjection using fluorescence calibration of streaming microdroplets on a superhydrophobic surface

Highlights: • Superhydrophobic surfaces prevent droplet surface adhesion and deformation. • Wide tipped micropipettes create a stream of microdroplets. • Streaming creates a large number of varying sized droplets quickly and easily. • Fluorescence-volume calibration curves can be created with tracer microdroplets. • Calibrated fluorescent tracers allow for quantifiable, cellular microinjection. A simple and reproducible procedure was developed to measure the volume of liquid microinjected into cells. A calibration curve of droplet fluorescence intensity versus volume was constructed by injecting a fluorescent dextran solution through a 125–150 µm diameter micropipette into an oil-filled culture dish to create a spray of varied-sized droplets. The droplets retained a spherical shape because they were in an oil medium and they settled onto a glass surface coated with a superhydrophobic surface. Fluorescent micrographs of the droplets were obtained and analyzed with Image-J software to quantify the fluorescence intensity and radius of each spherical droplet to produce the calibration curve. Subsequently, Dut-145 human prostate carcinoma cells were microinjected with the same fluorescent dextran solution and fluorescent micrographs of the cells were obtained using the identical exposure conditions used to photograph the droplets. The measured fluorescence intensity of the microinjected cells was entered into the formula for the regression line that was fit to the calibration curve allowing determination of the volume of solution injected into each cell. Thus, a mixture consisting of known concentrations of a test material of test material (macromolecules, drugs, etc.) and a fluorescent dextran, volumetric, tracer can be used to quantify the relationship between the amount of a microinjected material and subsequent effects on cells.

60 APPLIED LIFE SCIENCES↗

A Novel Method to Incorporate the Spatial Location of the Lung Dose Distribution into Predictive Radiation Pneumonitis Modeling

Purpose: Studies have proposed that patients who receive radiation therapy to the base of the lung are more susceptible to radiation pneumonitis than patients who receive therapy to the apex of the lung. The primary purpose of the present study was to develop a novel method to incorporate the lung dose spatial information into a predictive radiation pneumonitis model. A secondary goal was to apply the method to a 547 lung cancer patient database to determine whether including the spatial information could improve the fit of our model. Methods and Materials: The three-dimensional dose distribution of each patient was mapped onto one common coordinate system. The boundaries of the coordinate system were defined by the extreme points of each individual patient lung. Once all dose distributions were mapped onto the common coordinate system, the spatial information was incorporated into a Lyman-Kutcher-Burman predictive radiation pneumonitis model. Specifically, the lung dose voxels were weighted using a user-defined spatial weighting matrix. We investigated spatial weighting matrices that linearly scaled each dose voxel according to the following orientations: superior-inferior, anterior-posterior, medial-lateral, left-right, and radial. The model parameters were fit to our patient cohort with the endpoint of severe radiation pneumonitis. The spatial dose model was compared against a conventional dose-volume model to determine whether adding a spatial component improved the fit of the model. Results: Of the 547 patients analyzed, 111 (20.3%) experienced severe radiation pneumonitis. Adding in a spatial parameter did not significantly increase the accuracy of the model for any of the weighting schemes. Conclusions: A novel method was developed to investigate the relationship between the location of the deposited lung dose and pneumonitis rate. The method was applied to a patient database, and we found that for our patient cohort, the spatial location does not influence the risk of pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Apron heights around stepped massifs in the Cydonia Mensae region: Do they record the local paleobathymetry of Oceanus Borealis?

The use of photoclinometry and shadow measurements to determine the basin volume without linking the measurements to a global datum is described. Since the boundary, or shoreline, of the basin cannot be tied to the datum and typically has no useful local relative height to measure, what is needed is a number of measurements of the height of the paleoshorelines distributed across the basin. Photoclinometric profiles are being compiled from Viking Orbiter images of the Cydonia Mensae region, which includes images with high sun elevations, necessary to avoid shadows, and images with low sun elevations, to enable the use of shadow measurements as an independent check, at high resolution (40 to 100 m/pixel). Both asymmetric and symmetric photoclinometric profile models are being used, and the results cross checked with one another to minimize errors. An apron-height map, potentially a paleobathymetric map of part of the margin of Oceanus Borealis, can be compiled from this data to determine whether variations in apron height are consistent with a lacustrine interpretation.

Parker, T. J.↗

Irradiation of the prostate and pelvic lymph nodes with an adaptive algorithm

Purpose: The simultaneous treatment of pelvic lymph nodes and the prostate in radiotherapy for prostate cancer is complicated by the independent motion of these two target volumes. In this work, the authors study a method to adapt intensity modulated radiation therapy (IMRT) treatment plans so as to compensate for this motion by adaptively morphing the multileaf collimator apertures and adjusting the segment weights. Methods: The study used CT images, tumor volumes, and normal tissue contours from patients treated in our institution. An IMRT treatment plan was then created using direct aperture optimization to deliver 45 Gy to the pelvic lymph nodes and 50 Gy to the prostate and seminal vesicles. The prostate target volume was then shifted in either the anterior-posterior direction or in the superior-inferior direction. The treatment plan was adapted by adjusting the aperture shapes with or without re-optimizing the segment weighting. The dose to the target volumes was then determined for the adapted plan. Results: Without compensation for prostate motion, 1 cm shifts of the prostate resulted in an average decrease of 14% in D-95%. If the isocenter is simply shifted to match the prostate motion, the prostate receives the correct dose but the pelvic lymph nodes are underdosed by 14% {+-} 6%. The use of adaptive morphing (with or without segment weight optimization) reduces the average change in D-95% to less than 5% for both the pelvic lymph nodes and the prostate. Conclusions: Adaptive morphing with and without segment weight optimization can be used to compensate for the independent motion of the prostate and lymph nodes when combined with daily imaging or other methods to track the prostate motion. This method allows the delivery of the correct dose to both the prostate and lymph nodes with only small changes to the dose delivered to the target volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultra-faint ultraviolet galaxies at z ∼ 2 behind the lensing cluster A1689: The luminosity function, dust extinction, and star formation rate density

We have obtained deep ultraviolet imaging of the lensing cluster A1689 with the WFC3/UVIS camera onboard the Hubble Space Telescope in the F275W (30 orbits) and F336W (4 orbits) filters. These images are used to identify z ∼ 2 star-forming galaxies via their Lyman break, in the same manner that galaxies are typically selected at z ≥ 3. Because of the unprecedented depth of the images and the large magnification provided by the lensing cluster, we detect galaxies 100× fainter than previous surveys at this redshift. After removing all multiple images, we have 58 galaxies in our sample in the range –19.5 < M {sub 1500} < –13 AB mag. Because the mass distribution of A1689 is well constrained, we are able to calculate the intrinsic sensitivity of the observations as a function of source plane position, allowing for accurate determinations of effective volume as a function of luminosity. We fit the faint-end slope of the luminosity function to be α = –1.74 ± 0.08, which is consistent with the values obtained for 2.5 < z < 6. Notably, there is no turnover in the luminosity function down to M {sub 1500} = –13 AB mag. We fit the UV spectral slopes with photometry from existing Hubble optical imaging. The observed trend of increasingly redder slopes with luminosity at higher redshifts is observed in our sample, but with redder slopes at all luminosities and average reddening of (E(B – V)) = 0.15 mag. We assume the stars in these galaxies are metal poor (0.2 Z {sub ☉}) compared to their brighter counterparts (Z {sub ☉}), resulting in bluer assumed intrinsic UV slopes and larger derived values for dust extinction. The total UV luminosity density at z ∼ 2 is 4.31{sub −0.60}{sup +0.68}×10{sup 26} erg s{sup –1} Hz{sup –1} Mpc{sup –3}, more than 70% of which is emitted by galaxies in the luminosity range of our sample. Finally, we determine the global star formation rate density from UV-selected galaxies at z ∼ 2 (assuming a constant dust extinction correction of 4.2 over all luminosities and a Kroupa initial mass function) of 0.148{sub −0.020}{sup +0.023} M {sub ☉} yr{sup –1} Mpc{sup –3}, significantly higher than previous determinations because of the additional population of fainter galaxies and the larger dust correction factors.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimating the upper limit of gas production from Class 2 hydrate accumulations in the permafrost: 2. Alternative well designs and sensitivity analysis

In the second paper of this series, we evaluate two additional well designs for production from permafrost-associated (PA) hydrate deposits. Both designs are within the capabilities of conventional technology. We determine that large volumes of gas can be produced at high rates (several MMSCFD) for long times using either well design. The production approach involves initial fluid withdrawal from the water zone underneath the hydrate-bearing layer (HBL). The production process follows a cyclical pattern, with each cycle composed of two stages: a long stage (months to years) of increasing gas production and decreasing water production, and a short stage (days to weeks) that involves destruction of the secondary hydrate (mainly through warm water injection) that evolves during the first stage, and is followed by a reduction in the fluid withdrawal rate. A well configuration with completion throughout the HBL leads to high production rates, but also the creation of a secondary hydrate barrier around the well that needs to be destroyed regularly by water injection. However, a configuration that initially involves heating of the outer surface of the wellbore and later continuous injection of warm water at low rates (Case C) appears to deliver optimum performance over the period it takes for the exhaustion of the hydrate deposit. Using Case C as the standard, we determine that gas production from PA hydrate deposits increases with the fluid withdrawal rate, the initial hydrate saturation and temperature, and with the formation permeability.

54 ENVIRONMENTAL SCIENCES↗

Use of microphysical relationships to discern growth/decay mechanisms of cloud droplets with focus on Z-LWC relationships.

Cloud droplet size distributions hence the key microphysical quantities (e.g., radar reflectivity, droplet concentration, liquid water content, relative dispersion, and mean-volume radius) are determined by different physical mechanisms, including pre-cloud aerosols as CCNs, cloud updraft, and various turbulent entrainment-mixing processes. Therefore, different relationships among these microphysical properties are expected in response to these various mechanisms. The effect of turbulent entrainment-mixing processes is particularly vexing, with different entrainment-mixing processes likely leading to different microphysical relationships. Cloud radar has been widely used to infer the cloud liquid water content (L) from the measurement of radar reflectivity (Z) using a Z-L relationship. Existing Z-L expressions have been often obtained empirically, and differ substantially (Khain et al. 2008). The discrepancy among Z-L relations, which has been hindering the application of cloud radar in measuring cloud properties, likely stems from the different relationships between the relevant microphysical properties caused by different physical processes. This study first analyzes the Z-L relationship theoretically, and identify the key microphysical properties that affect this relationship, and then address the effects of various processes on the Z-L relationship by discerning the characteristics of the relationships between the relative dispersion, droplet concentration, liquid water content, and mean-volume radius calculated from in-situ measurements of cloud droplet size distributions. Effort is also made to further relate the microphysical relationships to physical processes such as turbulent entrainment-mixing.

54 ENVIRONMENTAL SCIENCES↗

Heat transfer rate distribution on North American Rockwell delta wing orbiter determined by phase change paint technique at a Mach number of 8, volume 1

The results of a wind tunnel test program to determine aerodynamic heat transfer distributions on an orbiter configuration are presented. Heat-transfer rates were determined by the phase change paint technique on 0.013-scale Stycast models using Tempilaq as the surface temperature indicator. The nominal test conditions were; Mach 8, length Reynolds numbers of 6.0 x 1 million and 8.9 x 1 million, and angles of attack from 10 to 50 deg in 10-deg increments. At the higher Reynolds number, data were obtained with and without boundary layer trips. Model details, test conditions, and reduced heat-transfer data are presented. Data reduction of the phase-change paint photographs was performed by utilizing a new technique which is described in the data presentation section.

Matthews, R. K.↗

Phase assemblage of composite cements

The phase assemblage of binary Portland cements with 45 wt% replacement by calcareous fly ash and slag has been investigated by experiment, mass balance and thermodynamic simulations. The input for these calculations was based on clinker reaction measured by XRD-Rietveld refinement, on SCM reaction measured by SEM-EDS full element mapping and on C-S-H composition by SEM-EDS point analyses. A sensitivity analysis estimates the uncertainty of determination of phase volume as at best ± 2 cm{sup 3}/100 cm{sup 3}, and thus of rather semi-quantitative character. The differences between experiment and calculations regarding AFt/AFm, C-S-H and portlandite were assessed. Gel/space ratios computed using the volumes of all hydrates showed a clear correlation to compressive strength, which was unaffected by the mix composition. This suggests that the type of hydrates formed has little or no influence on the compressive strength and that the key factor is the space filling.

36 MATERIALS SCIENCE↗

Thyroid V30 Predicts Radiation-Induced Hypothyroidism in Patients Treated With Sequential Chemo-Radiotherapy for Hodgkin's Lymphoma

Purpose: Hypothyroidism (HT) is a frequent late side effect of Hodgkin's lymphoma (HL) therapy. The purpose of this study is to determine dose-volume constraints that correlate with functional impairment of the thyroid gland in HL patients treated with three-dimensional radiotherapy. Methods and Materials: A total of 61 consecutive patients undergoing antiblastic chemotherapy and involved field radiation treatment (median dose, 32 Gy; range, 30-36 Gy) for HL were retrospectively considered. Their median age was 28 years (range, 14-70 years). Blood levels of thyroid-stimulating hormone (TSH), free triiodo-thyronine (FT3), free thyroxine (FT4), and thyroglobulin antibody (ATG) were recorded basally and at different times after the end of therapy. For the thyroid gland, normal tissue complication probability (NTCP), dosimetric parameters, and the percentage of thyroid volume exceeding 10, 20, and 30 Gy (V10, V20, and V30) were calculated in all patients. To evaluate clinical and dosimetric factors possibly associated with HT, univariate and multivariate logistic regression analyses were performed. Results: Eight of 61 (13.1%) patients had HT before treatment and were excluded from further evaluation. At a median follow-up of 32 months (range, 6-99 months), 41.5% (22/53) of patients developed HT after treatment. Univariate analyses showed that all dosimetric factors were associated with HT (p < 0.05). On multivariate analysis, the thyroid V30 value was the single independent predictor associated with HT (p = 0.001). This parameter divided the patients into low- vs. high-risk groups: if V30 was {<=} 62.5%, the risk of developing HT was 11.5%, and if V30 was >62.5%, the risk was 70.8% (p < 0.0001). A Cox regression curve stratified by two levels of V30 value was created (odds ratio, 12.6). Conclusions: The thyroid V30 predicts the risk of developing HT after sequential chemo-radiotherapy and defines a useful constraint to consider for more accurate HL treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing Collimator Margins for Isotoxically Dose-Escalated Conformal Radiation Therapy of Non-Small Cell Lung Cancer

Purpose: Isotoxic dose escalation schedules such as IDEAL-CRT [isotoxic dose escalation and acceleration in lung cancer chemoradiation therapy] (ISRCTN12155469) individualize doses prescribed to lung tumors, generating a fixed modeled risk of radiation pneumonitis. Because the beam penumbra is broadened in lung, the choice of collimator margin is an important element of the optimization of isotoxic conformal radiation therapy for lung cancer. Methods and Materials: Twelve patients with stage I-III non-small cell lung cancer (NSCLC) were replanned retrospectively using a range of collimator margins. For each plan, the prescribed dose was calculated according to the IDEAL-CRT isotoxic prescription method, and the absolute dose (D{sub 99}) delivered to 99% of the planning target volume (PTV) was determined. Results: Reducing the multileaf collimator margin from the widely used 7 mm to a value of 2 mm produced gains of 2.1 to 15.6 Gy in absolute PTV D{sub 99}, with a mean gain ± 1 standard error of the mean of 6.2 ± 1.1 Gy (2-sided P<.001). Conclusions: For NSCLC patients treated with conformal radiation therapy and an isotoxic dose prescription, absolute doses in the PTV may be increased by using smaller collimator margins, reductions in relative coverage being offset by increases in prescribed dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reverse-Contrast Imaging and Targeted Radiation Therapy of Advanced Pancreatic Cancer Models

Purpose: To evaluate the feasibility of delivering experimental radiation therapy to tumors in the mouse pancreas. Imaging and treatment were performed using combined CT (computed tomography)/orthovoltage treatment with a rotating gantry. Methods and Materials: After intraperitoneal administration of radiopaque iodinated contrast, abdominal organ delineation was performed by x-ray CT. With this technique we delineated the pancreas and both orthotopic xenografts and genetically engineered disease. Computed tomographic imaging was validated by comparison with magnetic resonance imaging. Therapeutic radiation was delivered via a 1-cm diameter field. Selective x-ray radiation therapy of the noninvasively defined orthotopic mass was confirmed using γH2AX staining. Mice could tolerate a dose of 15 Gy when the field was centered on the pancreas tail, and treatment was delivered as a continuous 360° arc. This strategy was then used for radiation therapy planning for selective delivery of therapeutic x-ray radiation therapy to orthotopic tumors. Results: Tumor growth delay after 15 Gy was monitored, using CT and ultrasound to determine the tumor volume at various times after treatment. Our strategy enables the use of clinical radiation oncology approaches to treat experimental tumors in the pancreas of small animals for the first time. We demonstrate that delivery of 15 Gy from a rotating gantry minimizes background healthy tissue damage and significantly retards tumor growth. Conclusions: This advance permits evaluation of radiation planning and dosing parameters. Accurate noninvasive longitudinal imaging and monitoring of tumor progression and therapeutic response in preclinical models is now possible and can be expected to more effectively evaluate pancreatic cancer disease and therapeutic response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Equation of state and strain-induced stabilization of δ-phase stabilized plutonium alloys

An in-situ high-pressure neutron diffraction experiment was conducted on a δ-phase stabilized plutonium alloy with isotope 242 Pu. Upon room-temperature compression, neither of the previously reported pressure-induced transformation paths, δ → α' or δ → γ’ → α', was observed up to 1.2 GPa. Instead, a drastic reduction in the diffraction intensity of the δ phase was observed when the pressure was above 0.8 GPa. At the highest pressure of the experiment (1.2 GPa), the diffraction data appear to be characteristic of an amorphous state, manifested by the diminishing intensities of all diffraction lines. Additionally, no evidence was found to support the transformation to a body-centered tetragonal structure (δ’), which was previously inferred from the diffraction line broadening during initial compression to 0.1 GPa. The discrepancies between the present and previous experiments suggest a substantial strain-induced stabilization of the δ-phase and is presumably attributed to the different stress states in the high-pressure environments. From the pressure - volume measurements, the determined isothermal bulk modulus for the δ-phase is in the range of 31.9 ± 1.3–34.8 ± 1.8 GPa using different pressure scales, comparable to those obtained from the resonant ultrasound spectroscopy measurements of the alloys of similar composition. Finally, the pressure-induced elastic softening is neither convinced in the present work, nor can it be resolved from the diffraction experiments if it is intrinsically weak.

36 MATERIALS SCIENCE↗

Revealing the synergistic effects of sequential and simultaneous dual beam irradiations in tungsten via in-situ TEM

Elucidating the synergistic effects of different energetic beams on the radiation response of nuclear materials is critical for developing an improved methodology for their evaluation when exposed to extreme environments. This article describes in-situ sequential (He implantation followed by Kr irradiation and vice-versa) and simultaneous (heavy ion Kr irradiation and He implantation) dual beam irradiations performed on tungsten at 1223 K. Dislocation loop density, average area, and total loop damage as a function of irradiation history and dose/fluence are quantified. The loop Burgers vectors and cavity damage (cavity density, size and total change in volume) are also determined at the final maximum dose for each condition. The loop damage evolution was different in all cases, with the smallest loop damage observed in the simultaneous experiment. Annihilation of Kr generated dislocation loops during He implantation in the Kr + He experiment was an unanticipated observation that may be explained by the dynamic evolution of dislocation loop sink strengths and time-dependent defect fluxes. Dislocation loop raft formation, denuded zones near extended defects, and cavity damage are compared across the different conditions. The phenomena observed and discussed in this work will stimulate further experimental and computational modeling activities leading to improved fundamental understanding of the irradiation response of nuclear materials under reactor-similar environments.

36 MATERIALS SCIENCE↗

The importance of prostate bed tilt during postprostatectomy intensity-modulated radiotherapy

Variations in rectal and bladder filling can create a tilt of the prostate bed, which generates the potential for a geographic miss during postprostatectomy radiotherapy. The aim of this study is to assess the effect that bladder and rectum filling has on planning target volume angle, to determine a method to assess prostate bed tilt leading to potential geographic miss, and to discuss possible implementation issues. The cone-beam computed tomography images (n = 377) of 40 patients who received postprostatectomy radiotherapy with intensity-modulated radiotherapy were reviewed. The amount of tilt in the prostate bed was defined as the angle change between 2 surgical clips, one in the upper prostate bed and another in the lower. A potential geographic miss was defined as movement of any clip of more than 1 cm in any direction or 0.5 cm posteriorly when aligned to bone anatomy. Variations in bladder and rectum size were correlated with the degree of prostate bed tilt, and the rate of potential geographic miss was determined. A possible clinical use of prostate bed tilt was then assessed for different imaging techniques. A tilt of more than 10° was seen in 20.2% of images, which resulted in a 57.9% geographic miss rate of the superior clip. When tilt remained within 10°, there was only a 9% rate of geographic miss. Potential geographic miss of the inferior surgical clip was rare, occurring in only 1.9% of all images reviewed. The most common occurrence when the prostate bed tilt increased by more than 10° was a smaller bladder and larger rectum (6.4% of all images). The most common occurrence when the prostate bed tilt decreased by more than 10° was a larger bladder and smaller rectum (1.3% of all images). Significant prostate bed tilt (>± 10°) occurred in more than 20% of images, creating a 58% rate of geographic miss. Greatest prostate bed tilt occurred when the bladder size increased or reduced by more than 2 cm or the superior rectum size increased by more than 1.5 cm or reduced by more than 1 cm from the planned size. Using prostate bed tilt could be an effective measurement for assessing potential geographic miss on orthogonal images if volumetric imaging is unavailable.

61 RADIATION PROTECTION AND DOSIMETRY↗