Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage prediction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Robust and symmetric magnetic field dependency of superconducting diode effect in asymmetric Dirac semimetal SQUIDs

The recent demonstration of the superconducting diode effect (SDE) has generated renewed interest in superconducting electronics, in which devices such as compact superconducting diodes that can perform signal rectification with low-energy operations are needed. In this article, we present our results of robust and symmetric-in-magnetic-field SDE in asymmetric superconducting quantum interference devices (SQUIDs) realized in high-quality Dirac semimetal Cd 3 As 2 thin film grown by the molecular beam epitaxy technique. Consistent with previous work, a zero magnetic field SDE is observed. Furthermore, the difference in switching current is independent of the strength and polarity of an out-plane magnetic field in the range of −10 and 10 mT. We speculate that this robust symmetric-in-field SDE in our Dirac semimetal SQUIDs is due to the formation of helical spin texture, theoretically predicted in Dirac semimetals.

Current-voltage characteristic↗

TRANSENSOR: Transformer Real-time Assessment INtelligent System with Embedded Network of Sensors and Optical Readout. Final Report

Utilities across the world are wrestling with evolving market dynamics, population growth and climate change. Distributed Energy Resources (DERs) such as solar photovoltaics, distributed generators and energy storage systems are becoming important parts of the U.S. energy mix. These factors are driving an increasing need for low-cost grid asset monitoring. Aside from being costly, traditional utility monitoring systems are not sufficiently robust and do not provide real-time visibility into the condition of grid assets such as transformers. Lack of accurate real-time measurements on performance has resulted in the use of lagging indicators, such as oil sample analysis. To address this need, an innovative embedded optical sensing technology, Transformer Real-time Assessment Intelligent System (TRANSENSOR) was developed, validated and demonstrated in this project. To date, TRANSENSOR has focused on transformers but is extendable to other grid assets. In addition to the technology being embedded into new transformers during manufacturing, a retrofit configuration that can be installed on existing transformers in the field was also developed. It is anticipated that the ability to retrofit existing transformers will help accelerate adoption of the underlying TRANSENSOR technology. Phase 1 of the project focused on laboratory development and qualification of the technology. Following iterations and exploration of relevant optical sensing modalities and multiplexed configurations of interest for the transformer environment, an effective candidate configuration was agreed upon, down-selected and custom-designed for embedding into General Electric (GE) network transformers. Two new GE 500 kilovolt ampere (kVA), 27 kilovolt (kV) distribution network transformers were built with embedded fiber-optic (FO) sensors and successfully qualified per industry standards at GE’s Shreveport, Louisiana facility during Phase 1 of the project. Following the successful completion of Phase 1, the team proceeded to Phase 2, which focused on a field demonstration of the technology. Over Phase 2, the first new GE transformer built with embedded fiber-optic sensors was installed in an above-ground cage and connected to the grid at Con Edison’s Astoria facility. A second transformer equipped with TRANSENSOR was installed in an underground vault. Additionally, an older (1982 year model) GE transformer in an above-ground cage was retrofitted with fiber- optic sensors and reconnected to the grid at ConEd’s facility. Analysis of data acquired from the sensors showed interesting correlations with transformer loading. Additionally, key events such as transformer low-voltage network connection, primary-side energizing, and a pressure loss event from an oil sampling were detected by the TRANSENSOR system. Online data processing/feature extraction algorithms for the second transformer in the underground vault detected key features and event alerts that were transmitted through a wireless 4G connection. The remote deployment concept showed promising results with data collection running for a total of 8 months across the three (3) GE transformers instrumented for the Phase 2 field demonstration. This sets the stage well for further development and commercialization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ensemble Federated Machine Learning‐Based Cybersecurity Situational Awareness in Microgrid Network

Cyber-physical microgrids are vulnerable to stealthy cybersecurity threats that disguise their actions through the exploitation of system knowledge. Such actions can severely impacts microgrids deployed in defense bases, slowing the response time of military forces during national emergencies. Several machine-learning algorithms have been proposed to detect intrusions in the grid networks; however, these traditional machine-learning algorithms lack data privacy and are subject to several adversarial machine-learning threats. This paper proposes a novel federated machine learning (FML)-based three-model framework to detect and identify stealthy data-integrity attacks while ensuring data privacy in microgrid networks. The proposed architecture uses a variational mode decomposition technique to extract derived features from incoming measurement and control datasets. The extraction of these derived features allows FML models to learn minute variations in data patterns that allow them to perform significantly better than the models trained with generic datasets consisting of raw features. Our experimental results show the efficient performance of the proposed methodology against different types of data integrity attacks while considering primary and secondary controllers in microgrids. Further, the applied FML-integrated random forest ensemble algorithm outperforms the existing generic FML algorithms during noisy and noise-free datasets with prediction latencies of only 91–134 µs per sample within the 0.1 s sampling interval and requires communication bandwidth of around ∼8.25 KB/s at the control center and ∼2.7 KB/s per edge client for communication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluating Variable-Impedance Magnetically-Insulated Transmission Lines as a Risk-Mitigation Measure for Next-Generation Pulsed Power

This project has produced the first detailed characterizations of power flow resulting from applying the “variable-impedance MITL” concept to real-life systems in Sandia’s pulsed power program (Z and next-generation pulsed power (NGPP)). We present simulation results and analyses for constant-impedance versions of both Z and NGPP and survey the operational viability of several variable-impedance re-designs in the parameter space of linear tapers. Circuit modeling (SCREAMER/Bertha) was used to pinpoint promising candidate designs, and EM-PIC (Empire) simulations were used to evaluate these candidates more rigorously. This approach was particularly successful in the Z regime which resulted in the identification of several viable variable-impedance MITL designs for each level. The approach was more challenged in the operating space NGPP occupies, producing data points that speak to a more restrictive design space due to anode plasma turn-on. In the end, we were able to converge on one viable variable-impedance design for the highest inductance line (level “F”) and one for the highest current line (level “A”). Altogether, the body of simulation evidence presented in this report suggest there does exist flexibility in operating space for magnetically-insulated transmission lines (MITLs) having variable geometric impedance to be a potential enabling technology for safely increasing current delivery (and potentially lowering stack voltage) in pulsed-power drivers by manipulating electron losses; however, operating points for a particular design must be carefully screened. Circuit and EM-PIC modeling provided consistent verdicts in safe operating regimes for operational viability, but additional physics such as anode plasma turn-on which is included in Empire but not in SCREAMER/Bertha was found to be a critical factor affecting power flow that lead to different assessments between the codes. It is not always the case that the occurrence of anode plasma caused a design to fail (some designs turned on anode plasma yet still delivered load currents meeting design targets); the details matter such as how early in the pulse anode surfaces break down (and how large a region). However, in every case that it did fail it was found that the feedback from anode plasma was the cause (i.e., turning off the anode plasma model in Empire restored agreement with the circuit model prediction). As circuit simulations represent an efficient and practical means of surveying design space compared to more computationally-expensive approaches such as EM-PIC, it could be prudent to invest in the research and development of models to include the effects of anode plasma such as ion emission in circuit codes. The variable-impedance MITL design is a new concept that enables controlled manipulation of the initial electron losses in the outer MITL and can be tested on Z today. We encourage follow-on work to explore further optimization (including alternative variable-impedance profiles, e.g., having constant dZ/dR), and to confirm the major findings presented in this report by fielding test hardware on actual Z shots.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Insights into Na + Diffusion in Silicon Modules under Operating Conditions: Measuring Low Concentrations by D-SIMS

Sodium induced shunting under an electric field is a challenging reliability issue in crystalline Si solar modules. The source of this Potential-Induced Degradation of the Shunting type (PID-s) is well understood and its influence on power loss has been intensively studied based on phenomenological models on cell or module level relating the experimental power-loss to stressing parameters (time, temperature, voltage). However, little is known about the Na ion migration kinetics, responsible for PID on a microscopic level, and its quantitative relation to the efficiency degradation. In this paper we present our investigations of sodium ion migration in Ethylene-Vinyl Acetate (EVA) and silicon through Dynamic Secondary Ion Mass Spectroscopy (D-SIMS). Each sample was annealed at field relevant temperatures from 60-90 °C to address typical migration mechanisms of common PV installations. Analysis of the SIMS migration profiles revealed a diffusivity constant D 0,EVA = 0.09 ± 0.14 cm 2 /s and an activation energy E A,EVA = 0.85 ± .04 eV for Na in EVA and diffusivities higher than extrapolated literature values in silicon (D 0,Si = (3.03 ± 2.42)x10 -5 cm 2 /s, and E A,Si = 0.98 ± 0.02 eV). The new insight will be included in a drift-diffusion based degradation model accounting for the partition coefficient across all relevant interfaces. This model can assist in predicting PID-failure in the field based on the given model stack and the diffusion of Na + through each material. Furthermore, this tool can be used for process optimization as well as material selection significantly reducing the cost and time to validate a technology.

14 SOLAR ENERGY↗

Prediction of Breakdown in Air and Solid Dielectrics: A Complete Plasma Model from Discharge Initiation to Flashover (Final Technical Report)

A major challenge for most of the technologies of today, and the technologies of the future, is the compact and reliable design of electrical insulation systems for their electrical components. Although controlled low-temperature plasmas (LTPs) or non-thermal plasmas in air at atmospheric pressure are of interest for a wide range of technologies, the appearance of such discharges is considered highly undesirable in insulation systems because they are precursors of a breakdown or flashover, where complete insulation failure takes place. For non-thermal plasmas, often only one mechanism, or the transition from one discharge mechanism to another, has typically been studied to date. On the other hand, in the case of thermal plasma applications, the conditions following the occurrence of an electric arc or flashover have always been considered. Here, there is a big technical gap: there is no paper describing a complete plasma model simulating all discharge mechanisms and their transitions from discharge initiation to electrical arc and flashover. To address this gap, a complete plasma model for both thermal and non-thermal plasmas should be developed using a hydrodynamic approach. The project aimed to build the model. The work has the potential to address industrial applications and is of great importance to higher voltage systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarking Density Functional Theory Methods for Efficient Calculations of a Strongly Correlated Li 1– x Ni 1– y O 2−δ System

Transition metal oxides (TMOs), such as LiNiO 2 , are promising candidates for energy storage and electronic devices due to their unique electronic properties, exceptional physical and chemical characteristics, and ability to adopt multiple oxidation states. However, accurately predicting their properties using mean-field density functional theory (DFT) is challenging due to the presence of strongly correlated d-electrons and the complex interplay between their structural, electronic, and magnetic responses. These challenges are further exacerbated by the need to model defects, surfaces, and interfaces, which require computationally efficient, large-scale simulations. To address these issues, we carry out a benchmark study on the Li 1–x NiO 2 system, evaluating the performance of several popular functionals. Our findings demonstrate that combining SCAN functional relaxation with single-step HSE calculations provides a practical and scalable computational strategy. This approach balances accuracy and efficiency, enabling high-throughput simulations of strongly correlated TMOs and improved predictive modeling capability of TMOs for practical applications.

25 ENERGY STORAGE↗

Scaling of energy delivered through an electrostatic discharge to a small series load

We study the energy delivered through a small-resistance series “victim” load during electrostatic discharge events in air. For gap lengths over 1 mm, the fraction of the stored energy delivered is mostly gap-length independent, with a slight decrease at larger gaps due to electrode geometry. The energy to the victim scales linearly with circuit capacitance and victim load resistance but is not strongly dependent on circuit inductance. This scaling leads to a simple approach to predicting the maximum energy that will be delivered to a series resistance for the case where the victim load resistance is lower than the spark resistance.

42 ENGINEERING↗

The Heuristic Dynamic Programming Approach in Boost Converters

In this study, a heuristic dynamic programming controller is proposed to control a boost converter. Conventional controllers such as proportional-integral-derivative (PID) or proportional-integral (PI) are designed based on the linearized small-signal model near the operating point. Therefore, the performance of the controller during the start-up, the load change, or the input voltage variation is not optimal since the system model changes by varying the operating point. The heuristic dynamic programming controller optimally controls the boost converter by following the approximate dynamic programming. The advantage of the HDP is that the neural network-based characteristic of the proposed controller enables boost converters to easily cope with large disturbances. An HDP with a well-trained critic and action networks can perform as an optimal controller for the boost converter. To compare the effectiveness of the traditional PI-based and the HDP boost converter, the simulation results are provided.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Gas-Phase Composition as a Predictive Metric for Calendar Life Behavior of Next-Generation Silicon Anodes

The expansion of renewable technologies and electrification of the transportation sector is driving increased demand for next-generation battery materials that provide higher power and energy density with superior cycling and calendar life stability. Silicon (Si) has a theoretical capacity nearly 10x that of graphite, and is therefore a promising anode material candidate to meet these rigorous performance demands. While leading Si anode battery demonstrations are approaching target metrics for cycle life, a series of complex and interrelated modes of reactivity lead to reduced calendar life and therefore challenge practical adoption of these materials. Deconvoluting the degradation processes that impact Si calendar life is critical to informing the rational and accelerated design of improved Si materials. In the present work, we employ novel sampling techniques and GC-MS-FID characterization to measure gas-phase composition during initial Si cycling, which we tie to selective mechanisms of Si passivation. We utilize a tiered analysis approach to identify and quantify the gas-phase reaction products associated with three advanced Si material candidates under practical operating conditions. Ex situ analysis of Si powders (pure chemical reactivity) is coupled with nondestructive in situ sampling of Si electrodes in a practical pouch-cell format (coupled chemical and electrochemical reactivity). We link the observed gas-phase species evolution to electrochemical behavior and measured calendar life of the three Si materials. Further, we evaluate the voltage-resolved evolution of gas-phase species for one such Si nanomaterial, where nonmonotonic gas generation implies competition between passivating reaction pathways. The measured gas-phase compositional data serves as a critical input for our advanced electrochemical SEI models to identify favorable vs unfavorable reaction pathways to stabilize Si. In addition to bolstering a fundamental understanding of Si reactivity, the present approach informs specific and quantifiable gas-phase metrics tied to calendar life improvements in Si, which can streamline and accelerate the process of next-generation material development.

DIRECT ENERGY CONVERSION,ENERGY STORAGE↗

Raw tensiometer soil matric potential data, from Oct 2017-Jun 2020 in Manaus, Brazil

This data package contains raw output from two Campbell Scientific CR1000 data loggers each connected to three UMS T4e tensiometer sensors in Manaus, Brazil. Tensiometers at each data logger location were installed to depths of 10 cm, 20 cm and 50 cm below the ground surface for the purpose of measuring soil matric potential at each depth. “Station 3” tensiometers were installed at approximately 2°36'31.68"S, 60°12'34.70"W. “Station 4” tensiometers were installed at approximately 2°36'32.46"S, 60°12'34.92"W. The files “tensio3.edit.202109.csv” and “tensio4.edit.202109.csv” contain raw data (with invalid data removed). A text editor will be required to view the raw files in .csv (comma-separated values) format. Data processing was limited to: 1) Editing column headers for clarity; 2) Applying a correction that converts voltage read by the data loggers to pressure units (kPa); 3) removing all data greater than 50 kPa and less than -115 kPa; 4) Adding columns entitled “Caution.10cm”, “Caution.20cm” and “Caution.50cm” that contains values of either “NA” or “Caution”, the latter of which is applied when data exceeds the manufacturer reported data validity range of less than -85 kPa to suggest use of these data with caution; 5) Adding columns entitled “Invalid.10cm”, “Invalid.20cm”, and “Invalid.50cm” that contains values of either “NA” or “Invalid”, the latter of which is applied when data accuracy is deemed compromised due to the introduction of air bubbles into the instrument. Data marked “Invalid” may still indicate general trends of wet/high matric potential and dry/low matric potential, but values are inaccurate and dry/low matric potential values are likely not low enough. Wet/high matric potential values are likely to be more accurate than dry/low matric potential values; 6) Data format changed from .dat to .csv. This research was performed as a part of the NGEE Tropics project, which aims to advance model predictions of tropical forest carbon cycle responses to a changing climate over the 21st Century.

54 ENVIRONMENTAL SCIENCES↗

Maximum power point tracking for a multi-layered piezoelectric heel charger with a levered mechanism toward impact-based energy harvesting

The piezoelectric footstep energy harvester does not always work at its maximum power point when the external load is fixed, as the optimal load changes when the walking excitation alters. Thus, the harvesting efficiency is downgraded largely in real-life scenarios compared to in-lab experiments and theoretical or numerical predictions due to the mismatch between the actual load and the optimal load. To address this issue, the concept of Maximum Power Point Tracking (MPPT) is investigated in this paper and the circuit design is implemented for a multi-layered levered piezoelectric footstep energy harvester (heel charger). The proposed event-driven MPPT circuit interface with a customized buck converter aims to maximize the power gained from daily walking using the heel charger to power a fixed load, such as smart insole or shoes. The MPPT circuit design is conceptually simulated and then tested with the heel charger to further validate if it works at its maximum power point when the frequency of the input excitation alters. Results show that the extracted power from the heel charger connected to a fixed resistance load with MPPT implementation is improved up to 300% compared to the one without MPPT implementation in simulation and up to 180% in the experiment when connected to a fixed load. The difference between simulation and experimental results is due to the optimization of using voltage sources as the heel charger and the control signals (pulse width modulation) from the microcontroller in the simulation.

47 OTHER INSTRUMENTATION↗

Calculating Interval Uncertainties for Calibration Standards That Drift with Time

Calibrated values of many devices exhibit predictable drift over time. To provide an uncertainty statement valid over the entire calibration interval, one must account for drift. In this article, a method of accounting for drift is proposed based on guidance in the Guide to Expression of Uncertainty in Measurement. An additional uncertainty term is computed using a linear regression of historical measurement data, which is included along with the time-of-test uncertainty. This method is evaluated by analyzing its average out-of-tolerance (OOT) rate using a Monte Carlo simulation, which results in the desired 5% average OOT rate when the total uncertainty is expanded to a 95% confidence interval.

47 OTHER INSTRUMENTATION↗

Probing the electronic properties of the electrified silicon/water interface by combining simulations and experiments.

Silicon (Si) is broadly used in electrochemical and photoelectrochemical devices, where the capacitive and Faradaic reactions at the Si/water interfaces are critical for signal transduction or noise generation. However, probing the electrified Si/water interface at the microscopic level remains a challenging task. Here we focus on hydrogenated Si surfaces in contact with water, relevant to transient electronics and photoelectrochemical modulation of biological cells and tissues. We show that by carrying out first principles molecular dynamics simulations of the Si(100)/water interface in the presence of an electric field we can realistically correlate the computed flat-band potential and tunneling current images at the interface with experimentally measured capacitive and Faradaic currents. Specifically, we validate our simulations in the presence of bias by performing pulsed chronoamperometry measurements on Si wafers in solution. Consistent with prior experiments, our measurements and simulations indicate the presence of voltage-dependent capacitive currents at the interface. We also find that Faradaic currents are weakly dependent on the applied bias, which we relate to surface defects present in newly prepared samples.

Ye, Zifan↗

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS↗

Spread Spectrum Time Domain Reflectometry (SSTDR) and Frequency Domain Reflectometry (FDR) for Detection of Cable Anomalies Using Machine Learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages. A related technology that has found some acceptance in the aircraft and rail industry is spread spectrum time domain reflectometry (SSTDR). This technology has been implemented with a custom commercial instrument by LiveWire Innovation Inc. that is designed to operate on live cables up to 1000 volts. One of the main conclusions of a previous effort was that cable reflectometry plots can be difficult for humans to analyze due to baseline noise, low or noisy anomaly response peaks, or large responses from cable ends. Detection of cable anomalies for many of these frequencies and test conditions was challenging for manual analysis. This presented an ideal opportunity for ML analysis to distinguish undamaged cable indications from anomalous cable indications. This research discusses application of machine learning (ML) to reflectometry cable test methods. The goal was to assess feasibility to distinguish undamaged cable reflectometry responses from damaged or anomalous cable reflectometry responses. The assessment considered the 3 instruments, multiple frequency bandwidths from each instrument, multiple cable anomalies and test conditions, and both supervised and unsupervised ML approaches. Although approaches and analysis methods were not identical or directly comparable, both outputs were encouraging. The unsupervised prediction weighted accuracy was assessed by instrument and by frequency. It performed better at high frequencies with the highest prediction accuracy of 0.84 for the higher frequency FDR, 0.79 for the 48-MHz LiveWire SSTDR, and 0.77 for 300-MHz PNNL SSTDR. The initial weighted accuracy average across all frequencies for using supervised ML was 0.56 to 0.68. The supervised analysis was repeated with noisier training data removed resulting in weighted accuracies of 0.69 to 0.87. These weighted accuracies are not directly comparable due to differences in the supervised and unsupervised analysis details but do indicate an encouraging trend. Even with limited and unbalanced data, strong prediction accuracies seem encouraging for further work including more data under a wider range of conditions.

42 ENGINEERING↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗