Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage mitigation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Space Weather, Geomagnetic Disturbances and Impact on the High-Voltage Transmission Systems

Geomagnetically induced currents (GIC) affecting the performance of high-voltage power transmission systems are one of the most significant hazards space weather poses on the operability of critical US infrastructure. The severity of the threat was emphasized, for example, in two recent reports: the National Research Council (NRC) report "Severe Space Weather Events--Understanding Societal and Economic Impacts: A Workshop Report" and the North American Electric Reliability Corporation (NERC) report "HighImpact, Low-Frequency Event Risk to the North American Bulk Power System." The NRC and NERC reports demonstrated the important national security dimension of space weather and GIC and called for comprehensive actions to forecast and mitigate the hazard. In this paper we will give a brief overview of space weather storms and accompanying geomagnetic storm events that lead to GIC. We will also review the fundamental principles of how GIC can impact the power transmission systems. Space weather has been a subject of great scientific advances that have changed the wonder of the past to a quantitative field of physics with true predictive power of today. NASA's Solar Shield system aimed at forecasting of GIC in the North American high-voltage power transmission system can be considered as one of the ultimate fruits of those advances. We will review the fundamental principles of the Solar Shield system and provide our view of the way forward in the science of GIC.

Pullkkinen, A.↗

Electric Drive Technologies Consortium (EDTC)/ Cost competitive, high-Performance, highly Reliable (CPR) Power Devices on 4H-SiC (Final Report)

4H-Silicon carbide (4H-SiC) is a wide bandgap semiconductor that offers superior material properties over silicon, including higher critical electric field, thermal conductivity, and electron saturation velocity. These advantages make 4H-SiC highly attractive for high-voltage, high-efficiency power electronics. However, realizing the full potential of SiC requires device technologies that are not only high-performing but also manufacturable and reliable under real-world operating conditions. This report summarizes the outcomes of a five-year R&D effort funded by the U.S. Department of Energy (DOE) under the Electric Drive Technologies Consortium (EDTC), focused on developing cost-competitive, high-performance, and highly reliable (CPR) power devices on 4H-SiC substrates. The program targeted scalable and manufacturable 1.2 kV-class SiC MOSFETs optimized for next-generation electric vehicles, renewable energy systems, and industrial power conversion. The project delivered transformative advancements in SiC power device performance and ruggedness. Particularly, Specific on-resistance (R on,sp ) was reduced by up to 37%, from ~4.0 m$\Omega \cdot$cm 2 in earlier designs to an industry-leading 2.40 m$\Omega \cdot$cm 2 , driven by optimized doping, refined JFET widths, and layout engineering. Breakdown voltages (BV) exceeded 1600 V, marking improvement over legacy baselines, and demonstrating the robustness of newly implemented junction profiles and edge terminations. Short-circuit withstand time (SCWT) saw a remarkable 4$\times$ increase, from ~2 $\mu$s to over 8 $\mu$s, achieved through the successful deployment of deep P-well structures (~1.8–2.0 $\mu$m) via channeling implantation. This innovative process breakthrough enabled precise junction formation without MeV-class implantation tools, reduced leakage under high field stress, and allowed even the shortest-channel devices (down to 0.3 $\mu$m) to achieve both high BV and excellent ruggedness—breaking the traditional trade-off between conduction efficiency and blocking capability. Several novel architectures pushed the performance envelope further. JBSFETs—featuring embedded Schottky portions—eliminated bipolar degradation and drastically reduced third-quadrant leakage, while Ladder MOSFETs introduced a clever orthogonal conduction path that achieved a 15.4% reduction in R on,sp over standard linear designs. Switching performance reached new benchmarks: short-channel devices showed a 31% reduction in total switching energy compared to 0.5 $\mu$m counterparts, while maintaining manageable gate drive requirements. Layout-optimized structures not only improved transconductance but also accelerated switching transitions, pointing to real-world benefits in converter-level efficiency. The devices also passed rigorous reliability validation. Stress-tested across TDDB, HTGB, HTRB, HVP, and burn-in, the devices screened under 30 V/10 hr and 43 V/1 s protocols consistently exhibited tighter lifetime distributions and long-term oxide robustness. These screening techniques proved effective in identifying latent defects and ensuring deployment-grade reliability. Meanwhile, advanced 3D TCAD simulations revealed and resolved electric field hotspots—particularly in HEXFET corners—where fields exceeding 4.8 MV/cm were mitigated through geometry-aware layout corrections. Overall, the results of this project demonstrate a manufacturable and scalable SiC power device platform that addresses key DOE performance targets for efficient, robust, and reliable 1.2kV 4H-SiC Power Devices. The developed technologies represent a meaningful step forward in the commercial readiness of high-voltage SiC solutions and provide a strong foundation for continued advancement in wide bandgap power electronics.

42 ENGINEERING↗

Grid Impact Studies from Dynamic Wireless Charging in Smart Automated Highways

Autonomous and electrified mobility are two key developments expected in the next decade to improve the efficiency and reduce carbon footprint of transportation. As electric vehicles (EVs) increase on the roads, one of the issues that needs to be addressed is range anxiety. To mitigate this problem and for seamless integration of EVs, dynamic wireless charging is an attractive solution. In this paper, a few case studies are considered in a smart autonomous highway to understand the impact of dynamic wireless charging on grid dynamics. The studies show that the grid voltages vary significantly due to the dynamic wireless power transfers (DWPTs), if connected to the existing grid. The variations in the grid voltage can reduce power transfers, increase grid instability, and cause inadvertent protection triggers. The inadvertent protection triggers can reduce the reliability of the connected grid. These problems highlight the need for modern grid infrastructure to support DWPT systems.

Debnath, Suman↗

Optimal Battery Charging for Damage Mitigation

Our control philosophy is to charge the NiH2 cell in such a way that the damage incurred during the charging period is minimized, thus extending its cycle life. This requires nonlinear dynamic model of NiH2 cell and a damage rate model. We must do this first. This control philosophy is generally considered damage mitigating control or life-extending control. This presentation covers how NiH2 cells function, electrode behavior, an essentialized model, damage mechanisms for NiH2 batteries, battery continuum damage modeling, and battery life models. The presentation includes graphs and a chart illustrating how charging a NiH2 battery with different voltages and currents affects damages the battery and affects its life. The presentation concludes with diagrams of control system architectures for tracking battery recharging.

Hartley, Tom T.↗

Signal-Anticipation in Local Voltage Control in Distribution Systems

We consider the signal-anticipating behavior in local Volt/Var control for distribution systems. Such a behavior makes interaction among the nodes a game. We characterize Nash equilibrium of the game as the optimum of a global optimization problem and establish its asymptotic global stability. We also show that the signal-anticipating voltage control has less restrictive convergence condition than the signal-taking control. We then introduce the notion of price of signal-anticipation (PoSA) to characterize the impact of signal-anticipating control, and use the gap in cost between network equilibrium in the signal-taking control and Nash equilibrium in the signal-anticipating control as the metric for PoSA. We characterize how the PoSA scales with the size, topology, and heterogeneity of the distribution network for a few network settings. Our results show that the PoSA is upper bounded by a constant and the average PoSA per node will go to zero as the size of the network increases. This is desirable as it means that the PoSA will not be arbitrarily large, no matter what the size of the network is, and no mechanism is needed to mitigate the signal-anticipating behavior. We further carry out numerical experiments with a real-world distribution circuit to complement the theoretical analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity for Distance Relay Protection

This project is a DOE follow-up effort on the CREDC workshop held on September 13, 2018 in Cambridge, MA to discuss cybersecurity of distance relays, which considered the benefits, vulnerabilities and risk mitigations for the use of communication systems in power system protection. The objectives of this project are to define the taxonomy of relay protection and associated communications; define use cases describing approaches to reduce the cyber-attack surface on those protective relays; and evaluate the loss of operational functional capability from changes to communication coverage. Mitigating controls will also be evaluated to understand if there are other approaches to reduce attack surfaces while maintaining communications or partial communications. Distance relays are used to protect transmission lines of approximately 10 to 300 miles in length, by detecting short circuits (i.e., faults) on the lines and then tripping circuit breakers in the substation. Such protection systems are a subset of the power system and they incorporate sensing, logic and communication functions. Protection system exposure to cyberattack could be drastically limited by disconnecting relays from all vulnerable communication systems, but this may adversely impact overall power system performance in the absence of cyberattack. This project began with a use case analysis of protection systems with communications, as summarized in this report. It continued with modeling, testing and evaluation in a miniature power system (MPS), located in the Western Area Power Administration (WAPA) Electric Power Training Center (EPTC). The project also incorporated feedback from two industry meetings held in February and September 2019. The suggested next steps account for and complement the work already underway with DOE/CESER funding: 1. Study the performance of LCD and PC vs. PUTT, which is less reliant on communication system performance and GPS timing references. The PUTT scheme could prove to be more resilient to cyberattack or communications-related disruption. It could also be more tolerant of message re-routing with SDN/SDR communication systems. On the other hand, it will be more vulnerable to false tripping during dynamic events or to loss of the voltage signal. The optimum choice of scheme may depend on the specific power system and risk assessment. This study could provide a new template for evaluation based on business functions. 2. Research and develop new methods to detect and monitor distributed physical attacks, possibly using drones, video sensors, thermal sensors, machine learning and other advanced techniques. This will help mitigate the impact of cyberattack on the protection system, and will also help mitigate the impact of wild fires. 3. Implement a scalable PKI for use in electric utility protection systems. This will encourage widespread adoption of secure authentication methods that are already available, but not widely used at present. This will help secure engineering access to the relays. 4. Investigate the use of SDN in combination with SDR to achieve better cybersecurity and electromagnetic security of the network, incorporating path variability. This would help secure both engineering access and peer-to-peer GOOSE messaging. 5. Perform additional testing, with operator evaluation of “red button” scenarios, PUTT vs. LCD, relay mis-operations, and other cyberattacks in the EPTC. This is an important advantage of testing in the EPTC rather than by computer simulation or even hardware-in-the-loop simulation; the EPTC is already dedicated to managing the situational awareness, operator response times and other human impacts. One of the project objectives was to settle on a common nomenclature for this problem space. We have concluded that the OSI layer model, supplemented by ANSI device numbers and other IEEE standards, is already well-accepted by the industry. The IEEE PSRC knowledge base provides a great deal of public information

24 POWER TRANSMISSION AND DISTRIBUTION↗

Complementary Electrolyte Design for Li Metal Batteries in Electric Vehicle Applications

In this report a complementary electrolyte system with 0.8 M lithium bis(fluorosulfonylimide) (LiFSI) salt and 2 wt % lithium perchlorate (LiCLO4) additive in fluoroethylene carbonate (FEC)/ethyl methyl carbonate (EMC) solution enables not only stable cycling of lithium metal batteries (LMBs) with practical loading (<30 μm lithium anode, cathode loading > 4 mAh/cm 2 ) but also outstanding degradation stability toward the end of cycle life when compared to the conventional electrolyte. Although the use of LiFSI salt can increase the electrolyte conductivity and lengthen the cycle life of LMBs, the aged lithium anode morphology formed by the sacrificial decomposition of LiFSI is highly porous, leading to an abrupt cell capacity drop toward the end of cycling. Moreover, the inability to stop aluminum corrosion by the LiFSI-based electrolyte also causes cracking of the cathode tab during prolonged cycling. It is observed that a highly porous aged lithium consumed electrolyte at a higher rate, leading to the dry-out of electrolyte solvents. On the contrary, dense aged lithium anode morphology increased the localized current applied on the lithium, causing the formation of lithium dendrite. Thus, porosity control is the key to enhance battery performance. In this complementary system, LiClO 4 was introduced as an advanced additive to not only improve the capacity retention rate but also mitigate the abrupt capacity drop toward the end of cycle life because LiClO 4 acted as a pore astringent reducing the porosity of the aged lithium metal anode to the desired level. Moreover, the addition of LiClO 4 can also suppress the AI corrosion, allowing stable high-voltage cycling of LMBs. The synergistic effect of combining LiFSI salt and a LiClO 4 additive leads to an electrolyte system that can facilitate the application of high-energy LMBs with practical electrode loading.

25 ENERGY STORAGE↗

Ultrastable cathodes enabled by compositional and structural dual-gradient design

Cathodes for next-generation batteries are pressed for higher voltage operation (≥4.5 V) to achieve high capacity with long cyclability and thermal tolerance. Current cathodes fail to meet these requirements owing to structural and electrochemical strains at high voltages, leading to fast capacity fading. Here, in this work, we present a cathode with a coherent architecture ranging from ordered to disordered frameworks with concentration gradient and controllable Ni oxidation activities, which can overcome voltage ceilings imposed by existing cathodes. This design enables simultaneous high-capacity and high-voltage operation at 4.5 V without capacity fading, and up to 4.7 V with negligible capacity decay. Multiscale diffraction and imaging techniques reveal the disordered surface is electrochemically and structurally indestructible, preventing surface parasitic reactions and phase transitions. Structural coherence from ordering to disordering limits lattice parameter changes, mitigating lattice strain and enhancing morphological integrity. The dual-gradient design also notably improves thermal stability, driving the advancement of high-performance cathode materials.

36 MATERIALS SCIENCE↗

Performance and Durability of Heavy-Duty Fuel Cell Systems with an Advanced Ordered Intermetallic ORR Alloy Catalyst and Novel Support

Ordered PtCo intermetallic (OIM) catalyst (L1 0 -PtCo/C) is a promising candidate as the oxygen reduction reaction (ORR) catalyst in hybrid fuel cell systems (FCS) for class-8 heavy duty (HD) trucks. Compared to a baseline annealed Pt on high surface area carbon (a-Pt/HSC) catalyst, its mass activity (MA) is 71% higher initially and 144% higher after 90,000 potential cycles in an accelerated stress test (AST). Analysis of the AST data indicates that the ORR kinetic constants do not change with aging and the degradation in the OIM catalyst activity is linearly proportional to the loss in the electrochemically active surface area (ECSA). Several operational strategies are investigated to mitigate catalyst degradation and achieve 25,000-h electrode lifetime and 2.5 kW g −1 Pt utilization on a HD truck duty cycle including load sharing with the hybrid battery, regulating the radiator fan power to maintain the coolant temperature close to 60 °C, clipping the maximum cell voltage below 850 mV, limiting the ECSA loss to 55%, and oversizing the active area of the membrane electrode assemblies by 20%. Drive cycle simulations indicate that the lifetime average voltage degradation rate is about 1.8 μV h −1 and the integrated stack and FCS drive cycle efficiencies decrease by 3.5 to 3.9%.

25 ENERGY STORAGE↗

Electromagnetic Thermocouple (TC) Anomaly Mechanisms During Atmospheric Entry

Thermocouples (TCs) are a critical diagnostic sensor for high enthalpy environments including Thermal Protection Systems (TPS) for atmospheric entry, hypersonic wind tunnels, and arc jet test facilities. They are used for both evaluating facility environmental conditions (enthalpy, and heat flux) as well as for measuring in-situ material thermal response under test conditions (thermal conductivity, heat capacity, etc.). Consequently, accurate TC measurements are fundamental for both material and facility Verification and Validation (V&V). However, a number of electromagnetic TC anomalies have been observed in both ground tests and flight instrumentations. These anomalies are caused via various coupling mechanisms: surface voltage coupling, Hall effect currents, and RF rectification. All of these mechanisms can, if unaddressed, result in obviously compromised results or worse, non-physical measurements which appear reasonable. This talk will provide an overview of each of these anomaly mechanisms and discuss ongoing efforts to quantify and mitigate them.

Magnus Haw↗

A Materials-Based Mitigation Strategy for SU/SD in PEM Fuel Cells: Properties and Performance-Specific Testing of IrRu OER Catalysts.

Catalysts that enable proton exchange membrane fuel cells to weather the damaging conditions experienced during transient periods of fuel starvation have been developed. The addition of minute amounts of iridium and ruthenium to the cathode enhances the oxygen evolution reaction (OER) during start-up/shutdown events, thus lowering the peak cell voltage closer to the onset of water oxidation. The catalyst loadings ranged from 1 to 10 g/cm2, but showed surprisingly high activity and durability. At such low loadings, it is possible to fully integrate the OER catalysts with negligible interference on fuel cell performance and a marginal increase in catalyst cost.

Atanasoski, Radoslav↗

Distribution System State Estimation in the Presence of High Solar Penetration

In recent years, the low-to-medium voltage distribution networks are experiencing rising levels of distributed energy resources, including renewable generation, along with improved sensing, communication and automation infrastructure. As such, state estimation methods for distribution systems are becoming increasingly relevant as a means to enable better control strategies that can both leverage the benefits and mitigate the risks associated with high penetration of variable and uncertain distributed generation resources. Primary challenges of this problem include modeling complexities (nonlinear non-convex power-flow equations), limited availability of sensor measurements, and high penetration of uncertain renewable generation. This paper formulates the distribution system state estimation as a nonlinear weighted least squares problem, based on sensor measurements as well as forecasts data (both load and generation). We investigate the sensitivity of state estimator accuracy to (load/generation) forecast uncertainties, sensor accuracy, and sensor coverage levels.

Distribution system state estimation, nonlinear op↗

NASA Tech Briefs, October 2013

Topics include: A Short-Range Distance Sensor with Exceptional Linearity; Miniature Trace Gas Detector Based on Microfabricated Optical Resonators; Commercial Non-Dispersive Infrared Spectroscopy Sensors for Sub-Ambient Carbon Dioxide Detection; Fast, Large-Area, Wide-Bandgap UV Photodetector for Cherenkov Light Detection; Mission Data System Java Edition Version 7; Adaptive Distributed Environment for Procedure Training (ADEPT); LEGEND, a LEO-to-GEO Environment Debris Model; Electronics/Computers; Millimeter-Wave Localizers for Aircraft-to-Aircraft Approach Navigation; Impedance Discontinuity Reduction Between High-Speed Differential Connectors and PCB Interfaces; SpaceCube Version 1.5; High-Pressure Lightweight Thrusters; Non-Magnetic, Tough, Corrosion- and Wear-Resistant Knives From Bulk Metallic Glasses and Composites; Ambient Dried Aerogels; Applications for Gradient Metal Alloys Fabricated Using Additive Manufacturing; Passivation of Flexible YBCO Superconducting Current Lead With Amorphous SiO2 Layer; Propellant-Flow-Actuated Rocket Engine Igniter; Lightweight Liquid Helium Dewar for High-Altitude Balloon Payloads; Method to Increase Performance of Foil Bearings Through Passive Thermal Management; Unibody Composite Pressurized Structure; JWST Integrated Science Instrument Module Alignment Optimization Tool; Radar Range Sidelobe Reduction Using Adaptive Pulse Compression Technique; Digitally Calibrated TR Modules Enabling Real-Time Beamforming SweepSAR Architectures; Electro-Optic Time-to-Space Converter for Optical Detector Jitter Mitigation; Partially Transparent Petaled Mask/Occulter for Visible-Range Spectrum; Educational NASA Computational and Scientific Studies (enCOMPASS); Coarse-Grain Bandwidth Estimation Scheme for Large-Scale Network; Detection of Moving Targets Using Soliton Resonance Effect; High-Efficiency Nested Hall Thrusters for Robotic Solar System Exploration; High-Voltage Clock Driver for Photon-Counting CCD Characterization; Development of the Code RITRACKS; and Enabling Microliquid Chromatography by Microbead Packing of Microchannels.

Source record↗

Improving CdMnTe Detector Performance by Adding 2% of Selenium

About 2% of selenium was added to CdMnTe (CMT) to reveal the role of selenium in CMT material used as a gamma-ray detector. The average etch-pit density (EPD) in a typical 2-in CdMnTeSe (CMTS) wafer was measured to be about 8.3×10 3 cm –2 except for the edge regions, and the radial nonuniformity of the bandgap along the wafer was about 2-meV. The typical mobility-lifetime product of electrons and holes was evaluated to be 3.06×10 –3 cm 2 /V and 3.1×10 –4 cm 2 /V, respectively. The energy resolution of the 122-keV photo-peak for a Co-57 radioactive source with a planar CMTS detector was 5.2%, demonstrating a positive effect associated with adding dilute amounts of Se to CMT. Finally, the enhanced detector performance in a planar CMTS detector is attributed to an improved value of hole mobility-lifetime product in CMTS, which mitigates the adverse hole tailing effect found in CdZnTe (CZT) and CMT detectors.

47 OTHER INSTRUMENTATION↗

In situ inorganic conductive network formation in high-voltage single-crystal Ni-rich cathodes

High nickel content in LiNi x Co y Mn z O 2 (NCM, x ≥ 0.8, x + y + z = 1) layered cathode material allows high specific energy density in lithium-ion batteries (LIBs). However, Ni-rich NCM cathodes suffer from performance degradation, mechanical and structural instability upon prolonged cell cycling. Although the use of single-crystal Ni-rich NCM can mitigate these drawbacks, the ion-diffusion in large single-crystal particles hamper its rate capability. Herein, we report a strategy to construct an in situ Li 1.4 Y 0.4 Ti 1.6 (PO 4 ) 3 (LYTP) ion/electron conductive network which interconnects single-crystal LiNi 0.88 Co 0.09 Mn 0.03 O 2 (SC-NCM88) particles. The LYTP network facilitates the lithium-ion transport between SC-NCM88 particles, mitigates mechanical instability and prevents detrimental crystalline phase transformation. When used in combination with a Li metal anode, the LYTP-containing SC-NCM88-based cathode enables a coin cell capacity of 130 mAh g -1 after 500 cycles at 5 C rate in the 2.75-4.4 V range at 25 °C. Tests in Li-ion pouch cell configuration (i.e., graphite used as negative electrode active material) demonstrate capacity retention of 85% after 1000 cycles at 0.5 C in the 2.75-4.4 V range at 25 °C for the LYTP-containing SC-NCM88-based positive electrode.

25 ENERGY STORAGE↗

Abstract for CRADA between NETL and Electric Power Research Institute (EPRI) (AGMT-1113)

The National Energy Technology Laboratory (NETL) and EPRI (Participant) will collaborate in the investigation of flashovers in electric power distribution maintenance operations. Live line and barehand maintenance techniques are used on overhead transmission lines around the world. While flashovers during this type of work are rare, several unexplained flashovers have occurred in North America. In each case, available evidence suggests these occurred at steady state (60 Hz) system voltage and at voltage stress levels well below that which is known to cause flashover. Understanding the cause of these flashovers is essential so they can be avoided in the future and enhance line worker safety. Some utilities are considering adding sheds to their live line tools (e.g. hot sticks) as a possible mitigation measure. The effect of adding sheds to the hot sticks was modelled and published by Chalmers University. A strong case can be made for sheds if the model can be validated through laboratory testing. This research is envisioned to be a multiple-year project. The work proposed under this agreement represents the initial research steps which will involve reproducing, verifying, and extending the modeling research previously published by Chalmers University.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cathode Side-emission Mitigation for Linear Induction Accelerators

Linear induction accelerators (LIAs) are one of the main technologies used in creating flash x-rays used for diagnosing hydrodynamic experiments. The quality of the data produced in these experiments is dependent on the dose of x-rays generated via bremsstrahlung radiation. There are several electron beam quantities that effect the amount of dose extracted from the bremsstrahlung radiation, such as beam instabilities, corkscrew motion, and beam emittance. Injector design is key in delivering well-behaved electron beams to the accelerator, and design choices include components such as anode-cathode (AK) gap dimensions based on required voltage and current, shroud shaping, and cathode type and composition. Thermionic cathodes have shown reliable performance in electron emission, however, if enough of the cathode side is subject to high-enough electric field values, electrons can be emitted. This issue is more likely to happen when the cathode is treated with materials that have lower work functions, which is common for cathodes used in LIAs. These extra electrons can work their way through the rest of the beam, inducing high non-linearities in phase space which can increase the emittance of this beam. In this paper we outline conducted trade-space studies where we examined different shaping parameters of the cathode shroud design to decrease the effect side electrons may have on the beam emittance. Particle trajectories are determined by electric potential contours across the face of the cathode shroud component, and so we hypothesize that the proper shaping of the cathode-shroud interface can tune the electric field to mitigate the effect of side electrons. Electron beam transport is simulated down the length of the injector and the beam quality is diagnosed by studying the emittance as a function of position. Acceptable emittance increase is recorded and noted to meet radiographic requirements.

42 ENGINEERING↗

Regulating in situ gaseous deposition to construct highly durable Fe–N–C oxygen-reduction fuel cell catalysts

The activity–stability trade-off challenges the design of high-performance atomically dispersed iron–nitrogen–carbon (Fe–N–C) catalysts for the acidic oxygen reduction reaction in polymer electrolyte fuel cells. Here we develop an in situ chemical vapour deposition approach during catalyst synthesis to break the trade-off, producing highly stable Fe–N–C catalysts while maintaining adequate oxygen reduction reaction activity. The optimal catalyst exhibits a half-wave potential of 0.867 V, remaining unchanged after an accelerated stress test (AST) of 100,000 potential cycles in rotating disk electrode tests. In membrane electrode assemblies under H 2 –air conditions, it delivers 93 mA cm −2 at 0.8 V after a standard AST of 30,000 voltage cycles, and shows minimal current density losses (2.9% at 0.6 V; 14.2% at 0.7 V) after an extended AST up to 120,000 cycles. Furthermore, the catalyst’s durability improvement is primarily due to the in situ chemical vapour deposition, which strengthens Fe–N bonds, increases active-site density, mitigates iron aggregates and reduces surface porosity.

Chemical engineering↗