Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “voltage limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 505 records · Page 28

Lightning testing at the subsystem level

Testing at the subsystem or black box level for lightning hardness is required if system hardness is to be assured at the system level. The often applied philosophy of lighting testing only at the system level leads to extensive end of the line design changes which result in excessive costs and time delays. In order to perform testing at the subsystem level two important factors must be defined to make the testing simulation meaningful. The first factor is the definition of the test stimulus appropriate to the subsystem level. Application of system level stimulations to the subsystem level usually leads to significant overdesign of the subsystem which is not necessary and may impair normal subsystem performance. The second factor is the availability of test equipment needed to provide the subsystem level lightning stimulation. Equipment for testing at this level should be portable or at least movable to enable efficient testing in a design laboratory environment. Large fixed test installations for system level tests are not readily available for use by the design engineers at the subsystem level and usually require special operating skills. The two factors, stimulation level and test equipment availability, must be evaluated together in order to produce a practical, workable test standard. The neglect or subordination of either factor will guarantee failure in generating the standard. It is not unusual to hear that test standards or specifications are waived because a specified stimulation level cannot be accomplished by in-house or independent test facilities. Determination of subsystem lightning simulation level requires a knowledge and evaluation of field coupling modes, peak and median levels of voltages and currents, bandwidths, and repetition rates. Practical limitations on test systems may require tradeoffs in lightning stimulation parameters in order to build practical test equipment. Peak power levels that can be generated at specified bandwidths with standard electrical components must be considered in the design and costing of the test system. Stimulation tests equipment and test methods are closely related and must be considered a test system for lightning simulation. A non-perfect specification that can be reliably and repeatedly applied at the subsystem test level is more desirable than a perfect specification that cannot be applied at all.

Luteran, Frank↗

Selected OAST/OSSA space experiment activities in support of Space Station Freedom

The Space Experiments Division at NASA Lewis Research Center is developing technology and science space experiments for the Office of Aeronautics and Space Technology (OAST) and the Office of Space Sciences and Applications (OSSA). Selected precursor experiments and technology development activities supporting the Space Station Freedom (SSF) are presented. The Tank Pressure Control Experiment (TPCE) is an OAST-funded cryogenic fluid dynamics experiment, the objective of which is to determine the effectiveness of jet mixing as a means of equilibrating fluid temperatures and controlling tank pressures, thereby permitting the design of lighter cryogenic tanks. The information from experiments such as this will be utilized in the design and operation of on board cryogenic storage for programs such as SSF. The Thermal Energy Storage Flight Project (TES) is an OAST-funded thermal management experiment involving phase change materials for thermal energy storage. The objective of this project is to develop and fly in-space experiments to characterize void shape and location in phase change materials used in a thermal energy storage configuration representative of an advanced solar dynamic system design. The information from experiments such as this will be utilized in the design of future solar dynamic power systems. The Solar Array Module Plasma Interaction Experiment (SAMPIE) is an OAST-funded experiment to determine the environmental effects of the low earth orbit (LEO) space plasma environment on state-of-the-art solar cell modules biased to high potentials relative to the plasma. Future spacecraft designs and structures will push the operating limits of solar cell arrays and other high voltage systems. SAMPIE will provide key information necessary for optimum module design and construction. The Vibration Isolation Technology (VIT) Advanced Technology Development effort is funded by OSSA to provide technology necessary to maintain a stable microgravity environment for sensitive payloads on board spacecraft. The proof of concept will be demonstrated by laboratory tests and in low-gravity aircraft flights. VIT is expected to be utilized by many SSF microgravity science payloads. The Space Acceleration Measurement System (SAMS) is an OSSA-funded instrument to measure the microgravity acceleration environment for OSSA payloads on the shuttle and SSF.

Delombard, Richard↗

2025 Intern Poster

The Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) houses the largest U.S. inert atmosphere hot cell for nuclear material research. Key features include the precision gamma scanning (PGS), Fuel Accident Condition Simulator (FACS), Neutron Radiography Reactor (NRAD), and the focus of this project, the Metallograph Loading Cell (MET Cell). The MET Cell performs tests on spent nuclear fuel, such as microhardness testing, microscopy, and neutron radiography. However, the MET Cell’s existing pressure and lighting control systems are outdated and inefficient, with inadequate documentation for system changes over time. This project aims to design a new automated control system for the MET Cell, ensuring longevity (minimum ten years), ease of troubleshooting/repair, and integration into the building monitoring system. The design process addressed challenges such as space restrictions, varied voltages within enclosures, sourcing new components, and security limitations. Compliance with NFPA 70, UL508A, MFC Physical Security, and INL Engineering standards was essential. The project involves repurposing an existing PLC to manage lighting and pressure control using digital and analog signals, simplifying wiring, and ensuring thorough documentation for future reference.

42 - ENGINEERING↗

Delineating the Impact of Diluent on High-Concentration Electrolytes for Developing High-Voltage LiNi 0.5 Mn 1.5 O 4 Spinel Cathode

LiNi 0.5 Mn 1.5 O 4 (LNMO) is a high-voltage spinel cathode with low nickel content, making it an attractive candidate for next-generation lithium-ion batteries (LIBs). However, its application is limited by interfacial instability with conventional carbonate-based electrolytes at high voltages. In this work, a localized saturated electrolyte (LSE) capable of stably operating up to 4.85 V is investigated. Molecular dynamics simulations and Fourier transform infrared spectroscopy reveal that adding “non-solvating” 1,1,2,2-tetrafluoroethyl-2,2,3,3-tetrafluoropropyl ether diluent in the saturated electrolyte, more PF 6 − anions are present in the first solvation shell of Li + , at the expense of solvent molecules. This tailored solvation environment promotes the formation of a robust, LiF-rich cathode-electrolyte interphase that mitigates transition metal dissolution and parasitic side reactions. The optimized LSE enables excellent cycling performance, with 95% capacity retention in Li|LNMO half-cells after 100 cycles and 94% retention in Li 4 Ti 5 O 12 |LNMO full cells after 250 cycles, even at a practically relevant LNMO cathode loading of ≈15 mg cm −2 . In conclusion, these results highlight the benefits of electrolyte engineering and solvation structure control in advancing high-voltage LIB technologies.

LNMO cathode↗

Control of wind turbine generators connected to power systems

A unique simulation model based on a Mode-O wind turbine is developed for simulating both speed and power control. An analytical representation for a wind turbine that employs blade pitch angle feedback control is presented, and a mathematical model is formulated. For Mode-O serving as a practical case study, results of a computer simulation of the model as applied to the problems of synchronization and dynamic stability are provided. It is shown that the speed and output of a wind turbine can be satisfactorily controlled within reasonable limits by employing the existing blade pitch control system under specified conditions. For power control, an additional excitation control is required so that the terminal voltage, output power factor, and armature current can be held within narrow limits. As a result, the variation of torque angle is limited even if speed control is not implemented simultaneously with power control. Design features of the ERDA/NASA 100-kW Mode-O wind turbine are included.

Hwang, H. H.↗

Multi-Fidelity Gaussian Process for Distribution System Voltage Probabilistic Estimation with PVs

The increasing penetration of behind-the-meter PVs causes challenges to maintain voltage security due to the lack of distribution system visibility. This paper proposes a nonlinear autoregressive Gaussian process (NARGP) approach to fuse limited number of SCADA/AMI data together with historical pseudo measurements for distribution node voltage probabilistic estimation. The high-fidelity SCADA data are fused with the low-fidelity AMI and pseudo measurements by the autoregressive algorithm embedded in the Gaussian process. This allows us to use multi-fidelity data to achieve entire distribution system voltage visibility. Numerical results carried out on the IEEE 123node system demonstrate that the NARGP method is able to obtain high accuracy in estimating bus voltage and quantifying estimation uncertainties as compared to other approaches.

distribution system estimation↗

Universal Relationship between Limiting Current and Electrochemical Transport Properties in Malonate-Based Polymer Electrolytes

There is considerable interest in developing high-performance electrolytes for rechargeable lithium batteries. For practical applications, the electrolyte must support large dc currents. However, the parameters most often reported in the literature, conductivity, κ, and current fraction, ρ + , reflect ion transport in the limit of infinitesimal currents. In this limit, the efficacy of an electrolyte is given by the product κρ + . The limiting current density, i lim , is the maximum current density that can be applied across an electrolyte; the cell voltage diverges if the applied current density exceeds ilim. This parameter reflects ion transport in the limit of large dc currents and is therefore of practical interest. It would therefore be convenient if i lim could be predicted from measurements of κρ + . In order to explore this possibility, we studied six malonate-based polymers and PEO at a fixed salt concentration (r = 0.08) and temperature (90°C) using symmetric cells with planar electrodes. Unfortunately, there is no correlation between ilim and κρ + . When the applied current density, i, is less than ilim, the cell voltage approaches a stable plateau, ϕ plateau . Here, we found a linear dependence between i and thickness-normalized plateau potential, ϕ plateau L –1 , irrespective of the magnitude of the applied current. In all seven polymer electrolytes, we found a linear correlation between ilim and the slopes of these lines, σ. In other words, measurements of σ can be used to predict the limiting current.

Jana, Rounak [Lawrence Berkeley National Laborator↗

A new approach to high-speed flow measurements using constant voltage anemometry

The paper addresses the basic features of conventional instrumentation, such as the constant temperature (CTA) and the constant current (CCA) anemometers, their limitations, and describes a totally new approach to high-speed dynamic measurements using a constant voltage anemometer (CVA). The paper describes the design features of a newly developed CVA and compares preliminary results obtained with CVA and conventional anemometry in low- and high-speed flows.

Mangalam, S. M.↗

SERT 2 thruster space restart, 1974

The results of testing the flight thrusters on the SERT spacecraft during the 1974 test period are presented. The most notable result was the clearing of the high voltage short from thruster 2 and the successful stable operation of its ion beam. Test periods were limited to 70 minutes or less by earth eclipse of the spacecraft solar array and by ground station coverage limitations. Thruster 2 was restarted 26 times with an ion beam produced 21 times. The high voltage short remains in thruster 1, but the cathodes were restarted 12 times to demonstrate continued restart capability. The propellant feed systems, power processors, and spacecraft ancillary equipment were demonstrated to be functional after 4 1/2 years in space. In addition to the thruster tests, a neutralizer cathode was operated separately to demonstrate that the potential level of a spacecraft could be controlled by the neutralizer alone.

Kerslake, W. R.↗

SERT II thruster space restart - 1974

The results of testing the flight thrusters on the SERT II spacecraft during the 1974 test period are presented. The most notable result was the clearing of the high voltage short from thruster 2 and the successful stable operation of its ion beam. Test periods were limited to 70 minutes or less by earth eclipse of the spacecraft solar array and by ground station coverage limitations. Thruster 2 was restarted 26 times with an ion beam produced 21 times. The high voltage short remains in thruster 1, but the cathodes were restarted 12 times to demonstrate continued restart capability. The propellant feed systems, power processors, and spacecraft ancillary equipment were demonstrated to be functional after 4-1/2 years in space. In addition to the thruster tests, a neutralizer cathode was operated separately to demonstrate that the potential level of a spacecraft could be controlled by the neutralizer alone.

Kerslake, W. R.↗

AC motor and generator requirements for isolated WECS

After surveying electrically driven loads used on productive farms, the investigators chose three pumps for testing at voltages and frequencies far outside the normal operating range. These loads extract and circulate water and move heat via air, and all are critical to farm productivity. The object was to determine the envelope of supply voltage and frequency over which these loads would operate stably for time intervals under 1 hour. This information is among that needed to determine the feasibility of supplying critical loads, in case of a utility outage, from a wind driven alternator whose output voltage and frequency will vary dramatically in most continental wind regimes. Other related work is surveyed. The salient features and limitations of the test configurations used and the data reduction are described. The development of simulation models suitable for a small computer are outlined. The results are primarily displayed on the voltage frequency plane with the general conclusion that the particular pump models considered will operate over the range of 50 to 90 Hz and a voltage band which starts below rated, decreases as frequency decreases, and is limited on the high side by excessive motor heating. For example, centrifugal pump operating voltage ranges as extensive .4 to 1.4 appear possible. Particular problems with starting, stalling due to lack of motor torque, high speed cavitation, and likely overheating are addressed in a listing of required properties for wind driven alternators and their controllers needed for use in the isolated or stand alone configuration considered.

Park, G. L.↗

Shock Generation and Control Using DBD Plasma Actuators

This report is the final report of a NASA Phase I SBIR contract, with some revisions to remove company proprietary data. The Shock Boundary Layer Interaction (SBLI) phenomena in a supersonic inlet involve mutual interaction of oblique shocks with boundary layers, forcing the boundary layer to separate from the inlet wall. To improve the inlet efficiency, it is desired to prevent or delay shock-induced boundary layer separation. In this effort, Innovative Technology Applications Company (ITAC), LLC and the University of Notre Dame (UND) jointly investigated the use of dielectric-barrier-discharge (DBD) plasma actuators for control of SBLI in a supersonic inlet. The research investigated the potential for DBD plasma actuators to suppress flow separation caused by a shock in a turbulent boundary layer. The research involved both numerical and experimental investigations of plasma flow control for a few different SBLI configurations: (a) a 12 wedge flow test case at Mach 1.5 (numerical and experimental), (b) an impinging shock test case at Mach 1.5 using an airfoil as a shock generator (numerical and experimental), and (c) a Mach 2.0 nozzle flow case in a simulated 15 X 15 cm wind tunnel with a shock generator (numerical). Numerical studies were performed for all three test cases to examine the feasibility of plasma flow control concepts. These results were used to guide the wind tunnel experiments conducted on the Mach 1.5 12 degree wedge flow (case a) and the Mach 1.5 impinging shock test case (case b) which were at similar flow conditions as the corresponding numerical studies to obtain experimental evidence of plasma control effects for SBLI control. The experiments also generated data that were used in validating the numerical studies for the baseline cases (without plasma actuators). The experiments were conducted in a Mach 1.5 test section in the University of Notre Dame Hessert Laboratory. The simulation results from cases a and b indicated that multiple spanwise actuators in series and at a voltage of 75 kVp-p could fully suppress the flow separation downstream of the shock. The simulation results from case c showed that the streamwise plasma actuators are highly effective in creating pairs of counter-rotating vortices, much like the mechanical vortex generators, and could also potentially have beneficial effects for SBLI control. However, to achieve these effects, the positioning and the quantity of the DBD actuators used must be optimized. The wind tunnel experiments mapped the baseline flow with good agreement to the numerical simulations. The experimental results were conducted with spanwise actuators for cases a and b, but were limited by the inability to generate a sufficiently high voltage due to arcing in the wind-tunnel test-section. The static pressure in the tunnel was lower than the static pressure in an inlet at flight conditions, promoting arching and degrading the actuator performance.

Patel, Mehul P.↗

Performance documentation of the Engineering Model 30 cm diameter Thruster

Presented are the results of extensive testing of two 30-cm ion thrusters which are virtually identical to the 900 series Engineering Model Thruster in an ongoing 15,000-hour life test. Included are performance data for the nominal full-power (2650 W) operating point; performance sensitivities to discharge voltage, discharge losses, accelerator voltage, and magnetic baffle current; and several power throttling techniques (maximum Isp, maximum thrust/power ratio, and two cases in between). Criteria for throttling are specified in terms of the screen power supply envelope, thruster operating limits, and control stability. In addition, reduced requirements for successful high voltage recycles are presented.

Bechtel, R. T.↗

An Information Theoretic Approach to Identify Dominant Voltage Influencers for Unbalanced Distribution Systems

Smart distribution grid with multiple renewable energy sources can experience random voltage fluctuations due to variable generation, which may result in voltage violations. Traditional voltage control algorithms are inadequate to handle fast voltage variations. Therefore, new dynamic control methods are being developed that can significantly benefit from the knowledge of dominant voltage influencer (DVI) nodes. DVI nodes for a particular node of interest refer to nodes that have a relatively high impact on the voltage fluctuations at that node. Conventional power flow-based algorithms to identify DVI nodes are computationally complex, which limits their use in real-time applications. This paper proposes a novel information theoretic voltage influencing score (VIS) that quantifies the voltage influencing capacity of nodes with DERs/active loads in a three phase unbalanced distribution system. VIS is then employed to rank the nodes and identify the DVI set. VIS is derived analytically in a computationally efficient manner and its efficacy to identify DVI nodes is validated using the IEEE 37-node test system. It is shown through experiments that KL divergence and Bhattacharyya distance are effective indicators of DVI nodes with an identifying accuracy of more than 90%. Additionally, the computation burden is also reduced by an order of 5, thus providing the foundation for efficient voltage control.

42 ENGINEERING↗

Vanadium and Niobium MXenes—Bilayered V 2 O 5 Asymmetric Supercapacitors

MXenes offer high metallic conductivity and redox capacitance that are attractive for high-power, high-energy storage devices. However, they operate limitedly under high anodic potentials due to irreversible oxidation. Pairing them with oxides to design asymmetric supercapacitors may expand the voltage window and increase the energy storage capabilities. Hydrated lithium preintercalated bilayered V 2 O 5 ( δ-Li x V 2 O 5 ·nH 2 O) is attractive for aqueous energy storage due to its high Li capacity at high potentials; however, its poor cyclability remains a challenge. To overcome its limitations and achieve a wide voltage window and excellent cyclability, it is combined with V 2 C and Nb 4 C 3 MXenes. Asymmetric supercapacitors employing lithium intercalated V 2 C (Li-V 2 C) or tetramethylammonium intercalated Nb 4 C 3 (TMA-Nb 4 C 3 ) MXenes as the negative electrode, and a δ-Li x V 2 O 5 ·nH 2 O composite with carbon nanotubes as the positive electrode in 5 m LiCl electrolyte operate over wide voltage windows of 2 and 1.6 V, respectively. The latter shows remarkably high cyclability—capacitance retention of ≈95% after 10 000 cycles. Here, this work highlights the importance of selecting appropriate MXenes to achieve a wide voltage window and a long cycle life in combination with oxide anodes to demonstrate the potential of MXenes beyond Ti 3 C 2 in energy storage.

36 MATERIALS SCIENCE↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere hour nickel cadmium spacecraft cells for the tracking data relay satellite system

Average end of charge voltages and pressures, and capacity output in ampere hours are presented. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are based on past cell performance data. The requirement does not constitute a limit for discontinuance from testing. The nickel cadmium batteries were screened for internal shorts, low capacity, electrolyte leakage, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test.

Hall, S. W.↗

A distributed voltage inference framework for cyber-physical attacks detection and localization in active distribution grids

The transition to active distribution grids with real-time monitoring and control depends on the proliferation of advanced communication networks and devices. This paradigm shift towards a cyber-physical architecture also introduces new vulnerabilities for adversaries to exploit and launch sophisticated cyber-physical attacks targeting grid observability. Current research highlights the challenges in distinguishing attacks on voltage phasor or nodal injection measurements and isolating multi-source attack locations in a multiphase distribution grid. The attack detection and localization methods in literature face accuracy issues, applications across diverse attack scenarios, or scalability limits. Here, to bridge these gaps, this paper proposes a distributed Voltage Inference framework for real-time detection and localization of cyber-physical attacks, addressing scalability, adaptability, and accuracy challenges in state-of-the-art methods. The proposed methodology leverages the distributed nature of the Voltage Inference framework through a two-step process of prediction and correction, together with a tractable graph partitioning approach, providing a reliable solution to identify compromised measurement sources and facilitate isolation. Extensive testing on IEEE 13 and 123-node distribution feeders underscores the algorithm’s efficacy, enhancing the security and resilience of active distribution grids against evolving cyber threats. Additionally, Hardware-in-the-Loop (HIL) implementation validates the proposed strategy’s practical applicability in real-world scenarios.

active distribution grids↗

Random pulse generator

An exemplary embodiment of the present invention provides a source of random width and random spaced rectangular voltage pulses whose mean or average frequency of operation is controllable within prescribed limits of about 10 hertz to 1 megahertz. A pair of thin-film metal resistors are used to provide a differential white noise voltage pulse source. Pulse shaping and amplification circuitry provide relatively short duration pulses of constant amplitude which are applied to anti-bounce logic circuitry to prevent ringing effects. The pulse outputs from the anti-bounce circuits are then used to control two one-shot multivibrators whose output comprises the random length and random spaced rectangular pulses. Means are provided for monitoring, calibrating and evaluating the relative randomness of the generator.

Lindsey, R. S., Jr.↗