Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “visualizing data variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

489 records · Page 28

EXCHANGE Campaign 1: A Community-Driven Baseline Characterization of Soils, Sediments, and Water Across Coastal Gradients

The EXploration of Coastal Hydrobiogeochemistry Across a Network of Gradients and Experiments (EXCHANGE) program is a consortium of scientists working together to improve our understanding of how the two-way exchange of water between estuaries or large lake lacustuaries and the terrestrial landscape influence the state and function of ecosystems across the coastal interface. EXCHANGE Campaign 1 (EC1) focuses on the spatial variation in biogeochemical structure and function at the coastal terrestrial-aquatic interface (TAI). In the Fall of 2021, the EXCHANGE Consortium gathered samples from 52 TAIs. Samples collected from EC1 were analyzed for bulk geochemical parameters, bulk physicochemical parameters, organic matter characteristics, and redox-sensitive elements.Please download ec1_README.pdf for a complete list of available data in each .zip folder, package version history, and detailed information about the project. This README will serve as the central place for EC1 Data Package updates. Experimental setup and v1 methods are documented in Myers-Pigg and Pennington et al., 2023 (https://doi.org/10.1038/s41597-023-02548-7).EC1 Data Package Structure:ec1_README.pdfec1_methods.pdfec1_metadata_v3.zip...ec1_dd.csv...ec1_flmd.csv...ec1_sample_catalog.csv...ec1_metadata_kitlevel.csv...ec1_metadata_collectionlevel.csv...ec1_data_collectionlevel.csv...ec1_igsn_metadata.csvec1_soil_v3.zipec1_sediment_v3.zipec1_water_v3.zipec1_processingscripts_v3.zipThis data package is on v3 and was originally published May 2023 (v1). Subsequent updates will be published here with new version numbers. Please see the Change History section in ec1_README.pdf for detailed changes.---Acknowledging EXCHANGE: General Support and Data Product UseWe ask that users of EXCHANGE data add the following acknowledgement when publishing data in scholarly articles and data repositories:"This research is based on work supported by COMPASS-FME, a multi-institutional project supported by the U.S. Department of Energy, Office of Science, Biological and Environmental Research as part of the Environmental System Science Program."

54 ENVIRONMENTAL SCIENCES↗

Particle-image Velocimetry Sensitivity through Automatic Differentiation

A commonly encountered difficulty in modern experimental fluid dynamics experiments is the need for full-flow visualization and measurement; traditional techniques such as hot-wire probes and laser Doppler velocimetry cannot provide such information without difficult scanning procedures. Particle-image velocimetry (PIV) is a measurement technique which can overcome this spatial limitation to provide real-time three-dimensional fluid velocity vectors for an entire plane within the flow, as opposed to a single point that is provided by other measurement techniques. To accomplish this, a PIV system seeds the fluid flow with tracer particles; these must have nearly the same density as that of the fluid and a high drag coefficient to ensure that they follow the fluid flow without deviation. A laser is sent through optics to expand its beam into a sheet which illuminates the plane of interest in the fluid. The particles reflect more light than the fluid, and their image is recorded using a high speed camera. Due to limitations in bandwidth, video cannot be taken fast enough to be useful, and instead pairs of images are captured with a known separation in time. The illuminated particles will move between the two images taken by the camera, and their relative motion can be used to compute the fluid velocity at that point. When a single camera is used, only two-dimensional velocity vectors can be computed, but with the addition of another camera this can be improved to full three-dimensional vectors. The flow's time evolution can be measured by taking series of image pairs and processing each pair to get the velocity field at the time between each image pair. Only the two-dimensional version will be considered in this work. To compute the velocity vectors of the flow, the images are broken up into interrogation regions, usually in a uniform grid. In the most basic PIV algorithm, corresponding regions in the image pairs are cross-correlated to compute the most likely displacement from one image to the next. This is used since the cross correlation will achieve a maximum value when the two interrogation regions line up the best. The location of the peak in the correlation map and scaling information for the optical setup is used to compute the particle displacement from one image to the next. This process is similar to holding two semi-transparent images and moving one until they match as well as possible. Sub-pixel displacements between images can be obtained by fitting a Gaussian function to the correlation peak. Knowing the displacement vector for each set of interrogation regions in the image pair, it is a simple matter to divide by the time gap between the two images to compute the fluid velocity at the point in time and space. Since there are many interrogation regions in each image pair, the velocity field for a sheet is sampled according to the arrangement of the interrogation regions. The sensitivity of the final computed vector to the input images is difficult to compute, and has led most considerations of uncertainty in the PIV field to apply Monte Carlo methods and correlations to quantify the systematic and random errors which result from application of various PIV algorithms. In this work, automatic differentiation (AD) has been used to trace the dependence of velocity vectors computed using the correlation-peak PIV algorithm back to the input values given to an artificial image generator. These initial results form the foundation for continued work in the application of AD to algorithms in PIV. They demonstrate that AD methods can be successfully applied to PIV algorithms without undue complexity. The derivatives of each individual vector with regard to the coefficients of the velocity field used to create the artificial images can be computed and the statistics of them considered collectively, or correlated between each other to quantify the effectiveness of a PIV algorithm. With the initial implementation complete, adding extra algorithms is relatively simple and considerable data can be generated for analysis. It is hoped that application of these methods can lead to improved PIV algorithms which demonstrate better sensitivity to small variations in particle displacement. While these methods can be used as an analysis tool for refinement of new algorithms, computation of actual resultant vector sensitivities to input images' individual pixels is the next logical step of this work. Such information will be analyzed with experimental data to produce a better understanding of how output vectors' uncertainty relates to the actual image pairs, and lead to automatic bad vector removal. (authors)

42 ENGINEERING↗

A Study of Nucleate Boiling with Forced Convection in Microgravity

The ultimate objective of basic studies of flow boiling in microgravity is to improve the understanding of the processes involved, as manifested by the ability to predict its behavior. This is not yet the case for boiling heat transfer even in earth gravity, despite the considerable research activity over the past 30 years. The elements that constitute the nucleate boiling process - nucleation, growth, motion, and collapse of the vapor bubbles (if the bulk liquid is subcooled) - are common to both pool and flow boiling. It is well known that the imposition of bulk liquid motion affects the vapor bubble behavior relative to pool boiling, but does not appear to significantly influence the heat transfer. Indeed, it has been recommended in the past that empirical correlations or experimental data of pool boiling be used for design purposes with forced convection nucleate boiling. It is anticipated that such will most certainly not be possible for boiling in microgravity, based on observations made with pool boiling in microgravity. In earth gravity buoyancy will act to remove the vapor bubbles from the vicinity of the heater surface regardless of how much the imposed bulk velocity is reduced, depending, of course, on the geometry of the system. Vapor bubbles have been observed to dramatically increase in size in pool boiling in microgravity, and the heat flux at which dryout took place was reduced considerably below what is generally termed the critical heat flux (CHF) in earth gravity, depending on the bulk liquid subcooling. However, at heat flux levels below dryout, the nucleate pool boiling process was enhanced considerably over that in earth gravity, in spite of the large vapor bubbles formed in microgravity and perhaps as a consequence. These large vapor bubbles tended to remain in the vicinity of the heater surface, and the enhanced heat transfer appeared to be associated with the presence of what variously has been referred to as a liquid microlayer between the bubble and the heater surface. The enhancement of the boiling process with low velocities in earth gravity for those orientations producing the formation of a liquid macrolayer described above, accompanied by "sliding" vapor bubbles, has been demonstrated. The enhancement was presented as a function of orientation, subcooling, and heated length, while a criterion for the heat transfer for mixed natural/forced convection nucleate boiling was given previously. A major unknown in the prediction and application of flow boiling heat transfer in microgravity is the upper limit of the heat flux for the onset of dryout (or critical heat flux - CHF), for given conditions of fluid-heater surfaces, including geometry, system pressure and bulk liquid subcooling. It is clearly understood that the behavior in microgravity will be no different than on earth with sufficiently high flow velocities, and would require no space experimentation. However, the boundary at which this takes place is still an unknown. Previous results of CHF measurements were presented for low velocity flow boiling at various orientations in earth gravity as a function of flow velocity and bulk liquid subcooling, along with preliminary measurements of bubble residence times on a flat heater surface. This showed promise as a parameter to be used in modeling the CHF, both in earth gravity and in microgravity. The objective of the work here is to draw attention to and show results of current modeling efforts for the CHF, with low velocities in earth gravity at different orientations and subcoolings. Many geometrical possibilities for a heater surface exist in flowing boiling, with boiling on the inner and outer surfaces of tubes perhaps being the most common. If the vapor bubble residence time on and departure size from the heater surface bear a relationship to the CHF, as results to be given indicate, it is important that visualization of and access to vapor bubble growth be conveniently available for research purposes. In addition, it is desirable to reduce the number of variables as much as possible in a fundamental study. These considerations dictated the use of a flat heater surface, which is rectangular in shape, 1.91 cm by 3.81 cm (0.75 x 1.5 inches), consisting either of a 400 Angstrom thick semi-transparent gold film sputtered on a quartz substrate which serves simultaneously as a heater and a resistance thermometer, or a copper substrate of the same size. The heater substrate is a disc which can be rotated so that the heated length in the flow direction can be changed from 1.91 to 3.81 cm (0.75 to 1.5 inches). The fluid is R-113, and the velocities can be varied between 0.5 cm/s and 60 cm/s. For a sufficiently low velocity the CHF can be modeled reasonably well at various orientations by the correlation for pool boiling corrected for the influence of bulk liquid subcooling, multiplied by the square root of q, the angle relative to horizontal. This arises from equating buoyancy and drag forces in the inverted positions where the vapor bubbles are held against the heater surface as they slide. A distortion of the measurements relative to pool boiling occurs as the flow velocity increases. In modeling this effect at different levels of subcooling it appeared appropriate to estimate the volumetric rate of vapor generation, using measurements of bubble frequency (or residence time), void fraction and average bubble boundary layer thickness. These were determined with the use of a platinum hot wire probe 0.025 mm in diameter by 1.3 mm long, applying a constant current to distinguish between contact with liquid or vapor. Two-dimensional spatial variations are obtained with a special mechanism to resolve displacements in increments of 0.025 mm. From such measurements it was determined that the fraction of the surface heat transfer resulting in evaporation varies inversely with the subcooling correction factor for the CHF. The measured inverse bubble residence time is normalized relative to that predicted for an infinite horizontal flat plate at the CHF, and is correlated well with the CHF normalized relative to that for pool boiling, for various orientation angles and subcooling levels. This correspondence is then combined with a normalizing factor for the energy flux leaving the heater surface at the CHF and the computed bubble radius at departure, determined from the balance between the outward velocity of the interface due to evaporation and the buoyance induced velocity of the center of mass of the bubble. The product of the CHF and the corresponding residence time was determined to be a constant for all orientations at a given bulk flow velocity and liquid subcooling, and must be determined empirically for each velocity and subcooling at present. It then becomes possible to predict the CHF for the different orientations, velocities, and subcoolings. These are compared with normalized measurements of the CHF for velocities ranging from 4 cm/s to 55 cm/s, subcoolings from 2.8 to 22.2 K, over orientations angles of 360 degrees.

Merte, Herman, Jr.↗